HomeMy WebLinkAbout05120002-Site PlanNote:
Contractor should verify site
sDeciflC nfotmatioo de~ctec
hereon with the approved
construction plans for this
Note:
Minimum Free[ yard - 20'
Minimum Side Yard - 3'
Minimum Aggregate. 6'
{Between Houses)
Minimum Rear Yard - N/A
LOT # 320
+13,434 SF
PaD 782.9 PER PLAN
IGar. FFE = 783.1 1 - HUNTCLIFFE ~ ELEV 6C
1st Fir FFE = 784.9 ! LEFT HAND - Full Brick ,
Bsmt FFE = 775.1 J FULL WALKOUT BSMT- 9 Walls
Drive Slope = 2 7% 3 CAR - Front Entry ....
- ' ~ Bay Windows, Wd Deck 5
I '1.0 f~et above curb
"°' ~ Z G~ge Finish Floor
[at center of drive.
· ~ = Proposed Grade
~ ~ = Drainage Flow
XX.X = Existing Grade
SAN MH
TC=782,88
ZEND SECTION
INV=767.85
%
::TM SEWER
r NDS lO;
qNV=768.30
133,66'
Flood Hazard Note:
Lot Number 320 lies within Zone "X" 3er the scaled location
on the Flood Insurance Rate Maps for Hamilton County,
Indiana (Community Panel #18057C0227F, dated February
19, 2003).
Note:
This drawing Is based upon construction plans and/or record
drawings prepared by omers ans is not based upon a field survey.
COOR Consultin~ & Land Services, Cora, does not warrant the
cormcthess or integrity pi this information. The con[rector/owner
should ved~y existing conditions pnor m construction. Any varying
field conditions or any discrepancy with the information contelne~
i~ereon should be immediately reported to COOR Consulting & Land
Services. Corp.; ia[lure th do so would result in the contractor/owners
assumption of liability,
303 WEST MAIN STREET KNIGHTSTOWN INDIANA
(888) 593-2667 (765) 345.5943 FAX~: (765) 345-5692
DATE: 11/23/05 J B #2003-100,320 REVISIONS:
SSDLAT
10 D.U.&S.E.
Conc Flatwork Sq. Ft = +778
Public Walk Sq Ft = +1119
Sod Sq Yds = +623
Seeding Sq Ft = +4624
,TM INLET
TC=780.34
SAN MH
The proposed const~ucaon grades depicted hereon are based upon
information, proposed grades and/or contours, taken from me
approved construction plans Drepared for this subdivision, Unless
stated hereon, no information pertaining to but not limited to.
fluctuating water table elevations, soil types or conditions within the
bulldiog area of said lot. has Dean provided or referenced on said
plans. With the cons[rucpon of a basement, it is recommended that
the lowest floor elevation be cons[ructed at least two (2) feet above
any adjoining bodies of water unless a s[udy of facts reveals
otherwise. Should any ground water be witnessed during
excavation of said structure, the lowest floor elevation should be
raised at least two (2] feet above the ground water level and
additional construction tech~ ques should be incorporated to
alleviate future problems
r~[~ Prepared For:
INSTR. #200500009934
PC 3. SLIDE 581
LOT # 320
14270 KLINGENSMITH BLVD.
CARMEL, IN 46033
Pulte Homes of Indiana