Loading...
HomeMy WebLinkAbout061013 Health and Wellness Suites comment ltrC l a y T o w n s h i p R e g i o n a l W a s t e D i s t r i c t w w w . c t r w d . o r g P h o n e ( 3 1 7 ) 8 4 4 - 9 2 0 0 F a x ( 3 1 7 ) 8 4 4 - 9 2 0 3 June 10, 2013 Mr. Ross Nixon American Structurepoint, Inc. 7260 Shadeland Station Indianapolis, IN 46256 Phone 317-547-5580 Subject: Health and Wellness Suites of Carmel Dear Mr. Nixon, The District has reviewed your submittal and we offer the following comments: 1) We ask that the prefix for the manhole be labeled as MH#HWS1 2) Existing MH#S2 should be labeled MH#MC-25 on sheet C.303. 3) Please show profile view of 8” lateral with all utility crossings. 4) Sheet C.303 plan and profile view please specify length of Jack and Bore and include casing material, thickness and diameter. 5) If Jack and Bore is utilized, granular backfill callout on profile view is not necessary. 6) Min. FFE of the structure must be set 1’ above TC of up or downstream manhole (Min: 856.61) 7) Please add a note to grease interceptor to refer to detail drawing sheet C.601 8) Please add hardscape/pavement bump out at interceptor location for serviceability. 9) Please send to CTRWD a full copy of the IDEM Application and Allocation packet. Please contact me at 844-9200 if you have any questions. Sincerely, Ryan Hartman District Engineer