HomeMy WebLinkAbout12005_2013-08-09_A402.pdfProject No.
Sheet No.
Revisions:
Date
Drawn By
Checked By
W
CHURCH SOLUTIONS
T&
BYRUM
A
R
C
H
ITEC
TS
required for the proper execution and
performance and completion of the require-
architectural elements and, in some cases,
service for use solely with respect to this
These drawings indicate the general scope of
the project in terms of architectural design
concept, the dimensions of building, the major
the structural, mechanical, and/or electrical
systems. The Drawings do not necessarily
indicate or describe all work required for full
ments of the Contract. On the basis of
the general scope indicated or described, the
trade contractors shall furnish all items
Use of Documents
projects or additions to this Project without
Project and shall not be used on other
Project are instruments of the Architect's
documents prepared by the Architect for this
The Drawings, Specifications, and other
written permission and due compensation to
Certified By
completion of the work.
the Architect.
Scope DrawingsT&W Corporation
46241
3841 W
. Morris St.
Indianapolis, Indiana
621 South Range Line Road, Carmel, Indiana 46032
Carmel United Methodist Church
Specially commissioned by T&W Church Solutions, and used under license.
12005 JW
B
CAD
8-9-13
SECTIONS AND DETAILSA402 URTIH
910060
NE STATE OF
IS
IRET
E RG
A NAIDD
AR
C
SEG
E
ONJ
W
R
YEL
B
RET
ISNo.
Y
ED
TCE M
Additions and Renovations to
Copyright 2013
C
160 W. Carmel Drive, Suite 240
Carmel, Indiana 46032
317-574-8808
www.byrumarchitects.net
TOP OF PARAPET BEYOND
R.T.U. (SEE MECHANICAL)
ROOF DRAIN
SLOPE DOW
N
1/4" PER FOOT
A402
01
SCALE: 3/4" = 1'-0"
RESTROO
M
ADDITIO
N SECTION
(HIGHER) F.F.
100'-0"
FIRST FLOOR
SOUTH END OF GYM
NASIUM
PREFINISHED M
ETAL STEPPED
4" C.M.U. SUBSTRATE
TO M
ATCH EXISTING
BRICK ROW
LOCK SPECIAL SHAPE
6" LOAD BERING STUDS PER
STRUCTURAL DRAW
INGS
R-19 BATT INSULATION
5/8" GYPSUM
BOARD OVER
VAPOR RETARDER
M
INIM
UM
R-7.5 CONTINUOUS
RIGID INSULATION SHEATHING
FACE BRICK TO M
ATCH EXISTING
BRICK TIES AT 16" O.C. EACH W
AY
EXISTING COURSING
±97'-11"
FOOTING W
ITH
CONFIRM
TOP OF
COURSING
±114'-7"
W
ALL W
ITH EXISTING
CONFIRM
TOP OF
W
ALL FOR OVERFLOW
DRAINAGE
±110'-7"
W
ITH EXISTING CONNECTOR
CONFIRM
TOP PLATE
FASCIA - M
ATCH FASCIA AT
BLOCKING W
ITH STAGGERED JOINTS
MULTIPLE LAYERS M
EM
BRANE
2-LAYERS 3/4" CDX PARAPET
(UNDER EACH ROOF JOIST)
SLOPE DOW
N
1/4" PER FOOT
STRUCTURALLY INDEPENDENT
2-HOUR 8" C.M
.U. FIRE W
ALL UP
TO BOTTOM
OF NON-COMBUSTABLE
ROOF SHEATHING (PER I.B.C. 705.6,
EXCEPTION 3.) (SEE STRUCTURAL)
6" LOAD BERING STUDS PER
STRUCTURAL DRAW
INGS
5/8" GYPSUM BOARD
REFER REFLECTED CEILING PLAN
W
HITE ADHERED M
EM
BRANE
ROOF ON M
INIM
UM
R-20 POLYISO
RIGID INSULATION FASTENED
TO METAL DECKCONCRETE FOOTING (SEE
STRUCTURAL)
8" C.M
.U. - GROUT CORES
CONCRETE SLAB, DRAINAGE FILL, AND
COMPACTED FILL (SEE STRUCTURAL)
(UNDER EACH ROOF JOIST)
#5 VERTICAL AT 32" O.C.
C.M.U. BOND BEAM
W
ITH
#5 CONTINUOUS
8" 12 GAGE STEEL JOISTS AT 16" O.C.
(SEE STRUCTURAL)
20 GAGE "B" DECK
(SEE STRUCTURAL)
6" LOAD BERING STUDS PER
STRUCTURAL DRAW
INGS
(UNDER EACH ROOF JOIST)
8" 12 GAGE STEEL JOISTS AT 16" O.C.
(SEE STRUCTURAL)
CONCRETE FOOTING (SEE
STRUCTURAL)
SEE PLUM
BING DRAW
INGS FOR
STORM
DRAINAGE PIPING
A402 02SCALE: 3/4" = 1'-0"
SECTIO
N AT EXIT OF EXISTING
±111'-11"
M
ATCH HEIGHT
(HIGHER) F.F.
100'-0"
FIRST FLOOR
(LOWER) F.F.
±98'-11"
FIRST FLOOR
±9'-0" (CONFIRM HEIGHT OF NEW EXTENDED CEILING INSIDE)±4'-0"
6" LOAD BERING STUDS PER
STRUCTURAL DRAW
INGS
R-19 BATT INSULATION
5/8" GYPSUM BOARD OVERVAPOR RETARDER
M
INIM
UM
R-7.5 CONTINUOUS
RIGID INSULATION SHEATHING
FACE BRICK TO M
ATCH EXISTING
BRICK TIES AT 16" O.C. EACH W
AY
(UNDER EACH ROOF JOIST)
NEW
OR REUSE COPING
TO M
ATCH EXISTING
FLASHING W
ITH W
EEPS
AT 32" O.C.
REFER STRUCTURAL
FACE OF BRICK BEYOND
1" TINTED TEM
PERED INSULATED
GLAZING IN PREFINISHED ALUM
INUM
ENTRANCES AND STOREFRONT
(FINISH WITH HIGH-PERFORMANCE
COATING TO MATCH EXISTING COLOR)
REFER REFLECTEDCEILING PLANCONCRETE FOOTING (SEESTRUCTURAL)
CONCRETE FOOTING (SEE
STRUCTURAL)
EXISTING FOOTING
(2) #5 BARS CONTINUOUS
(2) #5 BARS X 28" LONG
AT 12" O.C. W
ITH M
INIM
UM
6" EPOXY EM
BED INTO
EXISTING FOOTING
2'-0" M
INIM
UM
2'-0" MINIMUM
2'-6"
2'-0" (MINIMUM
30" BELOW
FINISHED GRADE)
#5 BARS AT 32" O.C.
(3) #5 BARS CONTINUOUS
(3) #5 BARS CONTINUOUS
2'-6"
1'-0"
2'-6" MINIMUM
1'-0"
#5 BAR CONTINUOUS EXISTING SLAB
EXISTING W
ALL
HORIZONTAL LADDER REINFORCING
AT 16" O.C. VERTICAL
W
HITE ADHERED M
EM
BRANE
ROOF ON 3/4" FIRE-RETARDANT-
TREATED PLYW
OOD DECK
6" 16 GAGE STEEL FRAM
ING
AT 16" O.C.