HomeMy WebLinkAbout12005_2013-08-09_E202.pdfNORTH
Project No.
Sheet No.
Revisions:
Drawn By
Checked By
W
CHURCH SOLUTIONS
T&
BYRUM
A
RC
H
ITEC
TS
required for the proper execution and
performance and completion of the require-
architectural elements and, in some cases,
service for use solely with respect to this
These drawings indicate the general scope of
the project in terms of architectural design
concept, the dimensions of building, the major
the structural, mechanical, and/or electrical
systems. The Drawings do not necessarily
indicate or describe all work required for full
ments of the Contract. On the basis of
the general scope indicated or described, the
trade contractors shall furnish all items
Use of Documents
projects or additions to this Project without
Project and shall not be used on other
Project are instruments of the Architect's
documents prepared by the Architect for this
The Drawings, Specifications, and other
written permission and due compensation to
Certified By
completion of the work.
the Architect.
Scope DrawingsT&W Corporation
46241
3841 W
. Morris St.
Indianapolis, Indiana
621 South Range Line Road, Carmel, Indiana 46032
Carmel United Methodist Church
Specially commissioned by T&W Church Solutions, and used under license.
12005 JW
B
CAD
8-9-13
FIRST FLOOR POWER AND FIRE ALARM PLANE202
E202
01
SCALE: 3/32" = 1'-0"
FIRST FLOOR POW
ER AND FIRE ALARM
PLAN
URTIH
910060
NE STATE OF
IS
IRET
E RG
A NAIDD
AR
C
SEGE
ONJ
W
R
YEL
B
RET
ISNo.
Y
ED
TCE M
Additions and Renovations to
Copyright 2013
C
160 W. Carmel Drive, Suite 240
Carmel, Indiana 46032
317-574-8808
www.byrumarchitects.net
Date
EXT.
GFI
44"44"44"
44"
GFI
44"
GFI
DW
EXT.
GFI
44"
GFI
44"/GFI
EXISTING PANEL "F"
225A, 120/240V, 1∅
44"GFI
EXISTING PANEL "A"
225A, 120/240V, 1∅
EXISTING PANEL "E"
225A, 120/240V, 1∅
RELOCATE POW
ER
FOR RELOCATED
H.V.A.C UNITS
(TYPICAL)
RTU
EW
H
EW
H
DEDICATED
DEDICATED
DEDICATED
DEDICATED
- CIRCUITS BY ELECTRICAL CONTRACTOR
TO MEET ELECTRICAL AND ENERGY CODES.
- DO NOT EXCEED 6 CONVENIENCE OUTLETS
ON A SINGLE 20 AMP CIRCUIT.
- COORDINATE POW
ER REQUIREMENTS
W
ITH MECHANICAL AND PLUMBING
CONTRACTORS
NOTE
ALL CIRCUITS TO RESTROOMS,
RESTROOM RTU, AND EXTERIOR
LIGHTING TO FEED FROM
EXISTING MAIN ELECTRICAL
ROOM EAST OF GYM KITCHEN.
1,520
350
190
300
150
390240200
90
300
210280 40
60
9090
200
150
150
60
60
110
240
3,790
1,300
600
110
870
1,30050
870
70 110
50
80
130
920
890
610
160
30
20
20
20
540
490
180 30
1010
630
630
280
280
40
630
730 400
80
360
5,480
90
40
40
280
186140
297
728
3737
584
275
148
713
145
164
612160
67
64
80
551
864
2333
1,297
546
551
95
3,589
197
140
372
243
268
172
101
265
223
110
165
195
78
190
562
2
3
4
5
6
7
KJHGFEDC
BA
1
54
93
SS
S
S
S
S
SS
SSS
SS
SS
S
S
S
SS
SSSSSS
S
SS SS SS
SSSSSS
SS
S
S S S
S
S
S
S
S
S S S
S
SS
S
S
SS
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
E E E
EEE
E E
E
E
E
E E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
EEE
EE
EE
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
EE
E
EE
E
E
E E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
EE
E E E
S
S
S
S
F
S
S
S
S
S SSSSS
E
S S
S
S
S S
S S
S
SSS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
E
E
E
S
S
S
S
S
S
S
S
S S SS
S
S
S S S
S
SS
S
S
S
S SS
S
S
S
SS
S
S S
S
S
S
S
S
S
S
S
SS
S3
3
S3
S
S
S S3S
S
S
S
S
SSSS
S3S
S
SS
S
S
S
S
S3
POWER, LIGHTING, & DATA SYMBOLSSINGLE POLE SWITCH AT 48" A.F.F. (UNLESS NOTEDDUPLEX RECEPTACLE AT 16" A.F.F. UNLESS NOTEDWATER PROOF DISCONNECT SROTHERWISE)EXHAUST FAN - SEE MECHANICAL GROUND FAULT INTERRUPT RECEPTACLEGFIGFI OTHERWISEWPGROUND FAULT INTERRUPT WATER PROOF RECEPTACLEELECTRICAL PANELP1 J-BOXJEF QUAD RECEPTACLE AT 16" A.F.F. UNLESS NOTEDOTHERWISEVOICE/DATA OUTLET ROUGH-IN AT 16" A.F.F. UNLESSNOTED OTHERWISE AND INSTALL CONDUIT UP TO PLENUM DIMMER SWITCH AT 48" A.F.F. (UNLESS NOTED OTHERWISE)3-WAY SWITCH AT 48" A.F.F. (UNLESS NOTEDOTHERWISE)3FLOOR VOICE.DATA OUTLET SSFLOOR RECEPTACLEFSSFIRE ALARM SYMBOLS LEGENDSMOKE DETECTORSDCOMBINATION HORN AND STROBES STROBE DUCT SMOKE DETECTOR AT H.V.A.C. UNIT BY MECHANICALCONTRACTOR (COORDINATE INTERFACE)NOTE: FIRE ALARM CONTRACTOR SHALL VERIFY USE OF EXISTINGFIRE ALARM SYSTEMS AND PANELS FOR THIS PROJECT PRIOR TOBIDDING THE WORK. PROVIDE COMPLETE SYSTEM MEETING ALLAPPLICABLE CODES AND STANDARDS.PULL STATION