Loading...
HomeMy WebLinkAbout12005_2013-08-09_P202.pdfNORTH Project No. Sheet No. Revisions: Drawn By Checked By W CHURCH SOLUTIONS T& BYRUM A RC H ITEC TS required for the proper execution and performance and completion of the require- architectural elements and, in some cases, service for use solely with respect to this These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of building, the major the structural, mechanical, and/or electrical systems. The Drawings do not necessarily indicate or describe all work required for full ments of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items Use of Documents projects or additions to this Project without Project and shall not be used on other Project are instruments of the Architect's documents prepared by the Architect for this The Drawings, Specifications, and other written permission and due compensation to Certified By completion of the work. the Architect. Scope DrawingsT&W Corporation 46241 3841 W . Morris St. Indianapolis, Indiana 621 South Range Line Road, Carmel, Indiana 46032 Carmel United Methodist Church Specially commissioned by T&W Church Solutions, and used under license. 12005 JW B CAD 8-9-13 PLUMBING DOMESTIC WATER PLANSP202 P202 01 SCALE: 3/32" = 1'-0" FIRST FLOOR PLUM BING DOMESTIC W ATER PLAN URTIH 910060 NE STATE OF IS IRET E RG A NAIDD AR C SEGE ONJ W R YEL B RET ISNo. Y ED TCE M Additions and Renovations to Copyright 2013 C 160 W. Carmel Drive, Suite 240 Carmel, Indiana 46032 317-574-8808 www.byrumarchitects.net Date NORTHP20202SCALE: 3/32" = 1'-0" BASEMENT PLUMBING DOMESTIC WATER PLAN WCHLAVHSK1EXISTINGWATER HEATEREXISTING 1" CWEXISTING 3/4" HW EXISTING 1-1/2" CW1/2" CW1/2" HW1/2" CW AND 1/2" HW FROM ABOVEOR FROM BELOW (CONFIRMUSABILITY OF EXISTING WATERSTUBBED UP FROM SLAB)RESTROOMB025CAFEB0531/2" CW AND 1/2" HWUP TO SINK ABOVE(SEE 01/P202)INSTALL SHUT-OFF VALVESBOTH CW AND HW AT PLENUMTHIS LOCATION (NOT SHOWN) 1/2" CW AND 1/2" HW UP TO SINK FROM BELOW (SEE 02/P202) SK1 DW OFFICE A105 CAFE B146 W OMEN A122 KITCHEN B147 M EN A123 RESTROOM B141 FAM ILY JANITOR B138 RECONFIGURE CW AND HW FROM ORIGINAL W C AND LAV THIS RESTROOM AS NEEDED RECONFIGURE 1/2" CW AND 1/2" HW FROM ORIGINAL SINK THIS CLASSROOM AS NEEDED ORIGINAL SINK LOCATION FPHB EXISTING 2" CW 1-1/2" CW UP TO EWCAND RESTROOMSABOVE (SEE 01/P202) 1-1/2" CW UP FROM BELOW (SEE 01/P202) EW C 1-1/2" CW 3/4" CW 3/4" CW 3/4" CW 3/4" CW 1" CW 1" CW 1" CW 3/4" CW 3/4" CW W CH W CH W C(TYPICAL) URURURH W CLAV (TYPICAL) 1-1/4" CW 1" CW ETW H ETW H 1-1/2" CW ALL W ORK SHALL COMPLY W ITH THE CURRENT INDIANA GENERAL ADMINISTRATION RULES (GAR) AND ALL CODES APPLICABLE TO THIS PROJECT INCLUDING, BUT NOT LIMITED TO, THE THE 1999 INDIANA MECHANICAL CODE (1997 UNIFORM PLUMBING CODE WITH INDIANA AMENDMENTS), THE 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007 WITH INDIANA AMMENDMENTS), A.D.A. (AMERICANS WITH DISABILITIES ACT), ICC/ANSI A117.1-2003 (AMAERICAN NATIONAL STANDARD - ACCESSIBILE AND USABLE BUILDINGS AND FACILITIES), AND ALL OTHER APPLICABLE STATE & LOCAL STANDARDS & REGULATIONS. REPORT ANY CONFLICTS BETWEEN THESE CODES & REGULATIONS AND THE W ORK INDICATED TO THE ARCHITECT/ENGINEER AT AW ARD OF CONTRACT. PLUMBING CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR THE COMPLETION AND OPERATION ALL SYSTEMS IN THIS SECTION OF W ORK. SUBMIT PRODUCT DATA OF ALL PLUMBING FIXTURES AND EQUIPMENT FOR APPROVAL PRIOR TO PURCHASE. ALLOW AT LEAST TW O W EEKS FOR APPROVAL PROCESS AFTER SUBMITTAL. COORDINATE PLUMBING W ORK W ITH OTHER TRADES TO AVOID CONFLICTS. COORDINATION MUST OCCUR PRIOR TO PURCHASING OR INSTALLING EQUIPMENT AND MATERIALS. ALL UNDERGROUND W ATER SUPPLY PIPING TO BE TYPE "K" BELOW CONCRETE SLAB. ALL HOT AND COLD W ATER PIPING SHALL BE TYPE "L" HARD COPPER W ITH COPPER OR W ROUGHT BRASS FITTINGS UNLESS NOTED OTHERW ISE. INSULATE ALL HOT AND COLD W ATER PIPING W ITH 1/2" ARMAFLEX PIPE INSULATION. PROVIDE AND INSTALL SHUT-OFF VALVES AT ALL FIXTURES. INSTALL DIELECTRIC UNIONS AT ALL CONNECTIONS DISSIMILAR MATERIALS. PLUMBING GENERAL NOTES MARK FIXTURE W C UR URINAL LAV MS 2'x2' MOP BASIN W ITH F.R.P. SPLASHES ON ADJACENT W ALLS TO 4' A.F.F. SK2 W ATER CLOSET - FLOOR MOUNTED FLUSHOMETER TANK URH ADA URINAL ADA LAVATORY - COUNTERTOP MOUNTED OVAL PROTECTED BY SKIRT FLOOR DRAIN FD ETW H W CH LAVH ADA LAVATORY - W ALL MOUNTED W ITH ADA PIPING PROTECTION BELOW CO CLEANOUT PLUM BING FIXTURE SCHEDULE SK1 SINK - STAINLESS STEEL DROP-IN W ITH 14" X 16" X 7" BOW L AND KITCHEN FAUCET EW C ADA DOUBLE DRINKING FOUNTAIN / ELECTRIC W ATER COOLER SINK - STAINLESS STEEL DROP-IN W ITH DOUBLE 14" X 16" X 8" DEEP BOW LS AND SINGLE LEVER PULL-OUT KITCHEN FAUCET FREEZE PROOF HOSE BIB FPHB ELECTRIC TANKLESS WATER HEATER SIMILAR TO EEMAX, INC. MODEL EX-DL, 6.5KW, 240V, 32A, 2.0 GPM BY PLUMBING CONTRACTOR MOUNTED AS HIGH AS POSSIBLE ON W ALL UNDER COUNTER. ONE REQUIRED EACH RESTROOM A122 AND A123. ROUTE HOT W ATER TO THREE LAVS EACH. BELOW COUNTERTOP ADA W ATER CLOSET - FLOOR MOUNTED FLUSHOMETER TANK. FLUSH HANDLE ON OPEN SIDE PER CODE. W C W C REPLACE TW O EXISTING IMPROPER FUNCTIONING W ATER CLOSETS REPLACE FAUCETS, DRAINS, AND P-TRAPS AT TW O EXISTING LAVATORIES REPLACE EXISTING IMPROPER FUNCTIONING W ATER CLOSET W C 1,520 350 190 300 150 390240200 90 300 210280 40 60 9090 200 150 150 60 60 110 240 3,790 1,300 600 110 870 1,300 870 70 110 50 80 130 920 890 610 160 30 20 20 20 540 490 180 30 1010 630 630 280 280 40 630 730 5,480 90 40 40 510 350 570 2040300001,68070 186140 297 728 3737 584 275 148 713 145 164 612160 67 64 80 551 864 2333 1,297 546 551 95 3,589 197 140 372 243 268 172 101 265 223 110 165 195 78 190 562 2 3 4 5 6 7 KJHGFEDC 1 54 93 SS S S S S SS SSS SS SS S S S SS SSSSSS S SS SS SS SSSSSS SS S S S S S S S S S S S S S SS S S SS S S S S SS SSS SSSSSSSSSSSSSSSSSSSSSS S S S SS S S S S S S S S S SS S S S S S S S SS S S S S S S SSS S3S3S3S3SSSS33EEEEEE EEE EEEE E E E EEE E E E E E E E E E E E E EE E E E E E E E E E E E E E E EE EE EE E E E E EE E E E E E E E E E E E E E E E E E E E E E E E E E E E E EE E E E E E E E E E EE E EE E E E E E E E E E E E E E E E E E E E E E E E EE EEEEEEEEEEE EE E E E S S S S F EE F S S S S S SSSSS E S SS S S S S S S SSS S S S S S S S S S S S S S S S SSS SS S S S S S S S S E E E S S S S S S S S S S SS S S S S S S SS S S S S SS S S S SS S S S S S S S S S S S SS S3 3 S3 S S S S3S S S S S SSSS S3S S SS S S S S S3