HomeMy WebLinkAbout12005_2013-08-09_P202.pdfNORTH
Project No.
Sheet No.
Revisions:
Drawn By
Checked By
W
CHURCH SOLUTIONS
T&
BYRUM
A
RC
H
ITEC
TS
required for the proper execution and
performance and completion of the require-
architectural elements and, in some cases,
service for use solely with respect to this
These drawings indicate the general scope of
the project in terms of architectural design
concept, the dimensions of building, the major
the structural, mechanical, and/or electrical
systems. The Drawings do not necessarily
indicate or describe all work required for full
ments of the Contract. On the basis of
the general scope indicated or described, the
trade contractors shall furnish all items
Use of Documents
projects or additions to this Project without
Project and shall not be used on other
Project are instruments of the Architect's
documents prepared by the Architect for this
The Drawings, Specifications, and other
written permission and due compensation to
Certified By
completion of the work.
the Architect.
Scope DrawingsT&W Corporation
46241
3841 W
. Morris St.
Indianapolis, Indiana
621 South Range Line Road, Carmel, Indiana 46032
Carmel United Methodist Church
Specially commissioned by T&W Church Solutions, and used under license.
12005 JW
B
CAD
8-9-13
PLUMBING DOMESTIC WATER PLANSP202
P202
01
SCALE: 3/32" = 1'-0"
FIRST FLOOR PLUM
BING DOMESTIC W
ATER PLAN
URTIH
910060
NE STATE OF
IS
IRET
E RG
A NAIDD
AR
C
SEGE
ONJ
W
R
YEL
B
RET
ISNo.
Y
ED
TCE M
Additions and Renovations to
Copyright 2013
C
160 W. Carmel Drive, Suite 240
Carmel, Indiana 46032
317-574-8808
www.byrumarchitects.net
Date
NORTHP20202SCALE: 3/32" = 1'-0" BASEMENT PLUMBING DOMESTIC WATER PLAN WCHLAVHSK1EXISTINGWATER HEATEREXISTING 1" CWEXISTING 3/4" HW EXISTING 1-1/2" CW1/2" CW1/2" HW1/2" CW AND 1/2" HW FROM ABOVEOR FROM BELOW (CONFIRMUSABILITY OF EXISTING WATERSTUBBED UP FROM SLAB)RESTROOMB025CAFEB0531/2" CW AND 1/2" HWUP TO SINK ABOVE(SEE 01/P202)INSTALL SHUT-OFF VALVESBOTH CW AND HW AT PLENUMTHIS LOCATION (NOT SHOWN)
1/2" CW
AND 1/2" HW
UP TO SINK FROM BELOW
(SEE 02/P202)
SK1
DW
OFFICE
A105
CAFE
B146
W
OMEN
A122
KITCHEN
B147
M
EN
A123
RESTROOM
B141
FAM
ILY
JANITOR
B138
RECONFIGURE CW
AND HW
FROM ORIGINAL W
C AND LAV
THIS RESTROOM AS NEEDED
RECONFIGURE 1/2" CW
AND
1/2" HW
FROM ORIGINAL SINK
THIS CLASSROOM AS NEEDED
ORIGINAL SINK LOCATION
FPHB
EXISTING 2" CW 1-1/2" CW UP TO EWCAND RESTROOMSABOVE (SEE 01/P202)
1-1/2" CW
UP FROM
BELOW (SEE 01/P202)
EW
C
1-1/2" CW
3/4" CW
3/4" CW
3/4" CW
3/4" CW
1" CW
1" CW
1" CW
3/4" CW
3/4" CW
W
CH
W
CH
W
C(TYPICAL)
URURURH W
CLAV
(TYPICAL)
1-1/4" CW
1" CW
ETW
H
ETW
H
1-1/2" CW
ALL W
ORK SHALL COMPLY W
ITH THE CURRENT INDIANA GENERAL
ADMINISTRATION RULES (GAR) AND ALL CODES APPLICABLE TO THIS PROJECT
INCLUDING, BUT NOT LIMITED TO, THE THE 1999 INDIANA MECHANICAL CODE (1997
UNIFORM PLUMBING CODE WITH INDIANA AMENDMENTS), THE 2010 INDIANA
ENERGY CONSERVATION CODE (ASHRAE 90.1-2007 WITH INDIANA
AMMENDMENTS), A.D.A. (AMERICANS WITH DISABILITIES ACT), ICC/ANSI
A117.1-2003 (AMAERICAN NATIONAL STANDARD - ACCESSIBILE AND USABLE
BUILDINGS AND FACILITIES), AND ALL OTHER APPLICABLE STATE & LOCAL
STANDARDS & REGULATIONS. REPORT ANY CONFLICTS BETWEEN THESE CODES
& REGULATIONS AND THE W
ORK INDICATED TO THE ARCHITECT/ENGINEER AT
AW
ARD OF CONTRACT.
PLUMBING CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND
EQUIPMENT REQUIRED FOR THE COMPLETION AND OPERATION ALL SYSTEMS IN
THIS SECTION OF W
ORK.
SUBMIT PRODUCT DATA OF ALL PLUMBING FIXTURES AND EQUIPMENT FOR
APPROVAL PRIOR TO PURCHASE. ALLOW
AT LEAST TW
O W
EEKS FOR APPROVAL
PROCESS AFTER SUBMITTAL.
COORDINATE PLUMBING W
ORK W
ITH OTHER TRADES TO AVOID CONFLICTS.
COORDINATION MUST OCCUR PRIOR TO PURCHASING OR INSTALLING
EQUIPMENT AND MATERIALS.
ALL UNDERGROUND W
ATER SUPPLY PIPING TO BE TYPE "K" BELOW
CONCRETE
SLAB. ALL HOT AND COLD W
ATER PIPING SHALL BE TYPE "L" HARD COPPER W
ITH
COPPER OR W
ROUGHT BRASS FITTINGS UNLESS NOTED OTHERW
ISE.
INSULATE ALL HOT AND COLD W
ATER PIPING W
ITH 1/2" ARMAFLEX PIPE
INSULATION.
PROVIDE AND INSTALL SHUT-OFF VALVES AT ALL FIXTURES.
INSTALL DIELECTRIC UNIONS AT ALL CONNECTIONS DISSIMILAR MATERIALS.
PLUMBING GENERAL NOTES
MARK
FIXTURE
W
C
UR
URINAL
LAV
MS
2'x2' MOP BASIN W
ITH F.R.P. SPLASHES ON ADJACENT W
ALLS TO 4' A.F.F.
SK2
W
ATER CLOSET - FLOOR MOUNTED FLUSHOMETER TANK
URH
ADA URINAL
ADA LAVATORY - COUNTERTOP MOUNTED OVAL PROTECTED BY SKIRT
FLOOR DRAIN
FD ETW
H
W
CH
LAVH
ADA LAVATORY - W
ALL MOUNTED W
ITH ADA PIPING PROTECTION BELOW
CO
CLEANOUT
PLUM
BING FIXTURE SCHEDULE
SK1
SINK - STAINLESS STEEL DROP-IN W
ITH 14" X 16" X 7" BOW
L AND KITCHEN FAUCET
EW
C
ADA DOUBLE DRINKING FOUNTAIN / ELECTRIC W
ATER COOLER
SINK - STAINLESS STEEL DROP-IN W
ITH DOUBLE 14" X 16" X 8" DEEP BOW
LS AND
SINGLE LEVER PULL-OUT KITCHEN FAUCET
FREEZE PROOF HOSE BIB
FPHB
ELECTRIC TANKLESS WATER HEATER SIMILAR TO EEMAX, INC. MODEL EX-DL,
6.5KW, 240V, 32A, 2.0 GPM BY PLUMBING CONTRACTOR MOUNTED AS HIGH AS
POSSIBLE ON W
ALL UNDER COUNTER. ONE REQUIRED EACH RESTROOM A122
AND A123. ROUTE HOT W
ATER TO THREE LAVS EACH.
BELOW
COUNTERTOP
ADA W
ATER CLOSET - FLOOR MOUNTED FLUSHOMETER TANK. FLUSH HANDLE
ON OPEN SIDE PER CODE.
W
C
W
C
REPLACE TW
O EXISTING
IMPROPER FUNCTIONING
W
ATER CLOSETS
REPLACE FAUCETS, DRAINS,
AND P-TRAPS AT TW
O
EXISTING LAVATORIES
REPLACE EXISTING
IMPROPER FUNCTIONING
W
ATER CLOSET
W
C
1,520
350
190
300
150
390240200
90
300
210280 40
60
9090
200
150
150
60
60
110
240
3,790
1,300
600
110
870
1,300
870
70 110
50
80
130
920
890
610
160
30
20
20
20
540
490
180 30
1010
630
630
280
280
40
630
730
5,480
90
40
40
510 350 570 2040300001,68070
186140
297
728
3737
584
275
148
713
145
164
612160
67
64
80
551
864
2333
1,297
546
551
95
3,589
197
140
372
243
268
172
101
265
223
110
165
195
78
190
562
2
3
4
5
6
7
KJHGFEDC
1
54
93
SS
S
S
S
S
SS
SSS
SS
SS
S
S
S
SS
SSSSSS
S
SS SS SS
SSSSSS
SS
S
S S S
S
S
S
S
S
S S S
S
SS
S
S
SS
S
S
S
S
SS SSS SSSSSSSSSSSSSSSSSSSSSS
S
S
S
SS
S
S
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
SSS S3S3S3S3SSSS33EEEEEE EEE EEEE
E E E
EEE
E
E
E
E
E
E E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
EE
EE
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
EE
E
EE
E
E
E E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
EE EEEEEEEEEEE
EE
E E E
S
S
S
S
F EE
F
S
S
S
S
S SSSSS
E
S SS
S
S S
S S
S
SSS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S SSS SS S
S
S
S
S
S
S
S
E
E
E
S
S
S
S
S
S
S
S
S S SS
S
S
S S S
S
SS
S
S
S
S SS
S
S
S
SS
S
S
S
S
S
S
S
S
S
S
S
SS
S3
3
S3
S
S
S S3S
S
S
S
S
SSSS
S3S
S
SS
S
S
S
S
S3