HomeMy WebLinkAbout12005_2013-09-03_E201 revised.pdfNORTH
Project No.
Sheet No.
Revisions:
Drawn By
Checked By
W
CHURCH SOLUTIONS
T&
BYRUM
A
RC
H
ITEC
TS
required for the proper execution and
performance and completion of the require-
architectural elements and, in some cases,
service for use solely with respect to this
These drawings indicate the general scope of
the project in terms of architectural design
concept, the dimensions of building, the major
the structural, mechanical, and/or electrical
systems. The Drawings do not necessarily
indicate or describe all work required for full
ments of the Contract. On the basis of
the general scope indicated or described, the
trade contractors shall furnish all items
Use of Documents
projects or additions to this Project without
Project and shall not be used on other
Project are instruments of the Architect's
documents prepared by the Architect for this
The Drawings, Specifications, and other
written permission and due compensation to
Certified By
completion of the work.
the Architect.
Scope DrawingsT&W Corporation
46241
3841 W
. Morris St.
Indianapolis, Indiana
621 South Range Line Road, Carmel, Indiana 46032
Carmel United Methodist Church
Specially commissioned by T&W Church Solutions, and used under license.
12005 JW
B
CAD
8-9-13
FIRST FLOOR LIGHTING PLANE201
E201
01
SCALE: 3/32" = 1'-0"
FIRST FLOOR LIGHTING PLAN
URTIH
910060
NE STATE OF
IS
IRET
E RG
A NAIDD
AR
C
SEGE
ONJ
W
R
YEL
B
RET
ISNo.
Y
ED
TCE M
Additions and Renovations to
Copyright 2013
C
160 W. Carmel Drive, Suite 240
Carmel, Indiana 46032
317-574-8808
www.byrumarchitects.net
Date
A
A
A
AA
A
A
A
AA A
AAA
A A
AA
A
A
A
A
A
A
A
A
A
A
AA
A A A
A
AA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A A A
A A
A A
A A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B B B
B B B
B
C C C C
C C C C
C C C C
C C C C C C C
C
C C C C
C C C
C C
C C
C C
C C
REINSTALL EXISTING
LIGHT FIXTURES FROM
THIS SPACE
H
H
HHHHH
H
HHH
HHH
HHH
G
G
G
G
G
GG
J
J
J
J
GGG
G
G G
F
X
XX
XX
X
X
X
X
X XC
C
C
C
C
C
MMM
MMM
M
P
P
P
P
G
G
G
S2
S2
S1S1
T (20')
T (12')
TO EXISTING
SW
ITCH
TO EXHAUST
FAN - SEE
MECHANICAL
TO EXHAUST
FAN - SEE
MECHANICAL
THESE FIXTURES
ARE AT EXISTING
LOCATIONS
THESE FIXTURES
ARE AT EXISTING
LOCATIONS
TO EXISTING
SW
ITCH
TO EXHAUST
FAN - SEE
MECHANICAL
TO PHOTOCELL/
TIMER AT EXISTING
B B
BB
REINSTALL THREE EXISTING
LIGHT FIXTURES FROM NEARBY
W
ALL BEING REMOVED
REINSTALL EXISTING
LIGHT FIXTURES FROM
THIS SPACE
TO EXISTING
SW
ITCH
F
F
F
F F
F
F
F
F
F
M
M
- CIRCUITS BY ELECTRICAL CONTRACTOR
TO MEET ELECTRICAL AND ENERGY CODES.
- DO NOT EXCEED 6 CONVENIENCE OUTLETS
ON A SINGLE 20 AMP CIRCUIT.
- COORDINATE POW
ER REQUIREMENTS
W
ITH MECHANICAL AND PLUMBING
CONTRACTORS
NOTE
ALL CIRCUITS TO RESTROOMS,
RESTROOM RTU, AND EXTERIOR
LIGHTING TO FEED FROM
EXISTING MAIN ELECTRICAL
ROOM EAST OF GYM KITCHEN.
ALL WORK SHALL COMPLY WITH THE CURRENT INDIANA GENERAL ADMINISTRATION RULES (GAR) AND ALL CODES APPLICABLE TO THIS PROJECT INCLUDING, BUT NOT LIMITED TO, THE THE 2009 INDIANA ELECTRICAL CODE (2008 NFPA-70), THE NATIONAL FIRE ALARM CODE (NFPA-72), THE 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007 WITH INDIANA AMENDMENTS), 2010 A.D.A. (AMERICANS WITH DISABILITIES ACT), ICC/ANSI A117.1-2003 (AMERICAN NATIONAL STANDARD - ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES), AND ALL OTHER APPLICABLE STATE & LOCAL STANDARDS & REGULATIONS. REPORT ANY CONFLICTS BETWEEN THESE CODES & REGULATIONS AND THE WORK INDICATED TO THE ARCHITECT/ENGINEER AT AWARD OF CONTRACT.ELECTRICAL CONTRACTOR SHALL CONTACT THE LOCAL POWER COMPANY, PROVIDE ALL LABOR & MATERIALS, AND PAY ALL COST & FEES FOR A COMPLETE NEW ELECTRICAL SERVICE.ELECTRICAL CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR THE COMPLETION AND OPERATION ALL SYSTEMS IN THIS SECTION OF WORK.SUBMIT PRODUCT DATA OF ALL LIGHTING & ELECTRICAL EQUIPMENT AND DEVICES FOR APPROVAL PRIOR TO PURCHASE. ALLOW AT LEAST TWO WEEKS FOR APPROVAL PROCESS AFTER SUBMITTAL.COORDINATE ELECTRICAL WORK WITH OTHER TRADES TO AVOID CONFLICTS. COORDINATION MUST OCCUR PRIOR TO PURCHASING OR INSTALLING EQUIPMENT AND MATERIALS.ALL INTERIOR LIGHTING SHALL BE CONTROLLED BY DUAL TECHNOLOGY OCCUPANCY SENSORS AT ALL AREAS.ALL EXTERIOR LIGHTING TO BE CONTROLLED BY TIMER AND PHOTOCELL.ALL LIGHTING BALLAST SHALL BE ELECTRONIC.ALL CONDUCTORS SHALL BE COPPER.SIZE ALL CIRCUITS AND FEEDERS FOR LOADS AND LENGTHS. DO NOT EXCEED A 3VOLTAGE DROP.INSTALL EMT CONDUIT IN ALL OPEN AREAS AND WHERE EXPOSED.LABEL ALL DISTRIBUTION EQUIPMENT, PANELS, DISCONNECTS, AND CIRCUITS.ELECTRICAL GENERAL NOTES
9-03-13
1,520
350
190
300
150
390240200
90
300
210280 40
60
9090
200
150
150
60
60
110
240
3,790
1,300
600
110
870
1,30050
870
70 110
50
80
130
920
890
610
160
30
20
20
20
540
490
180 30
1010
630
630
280
280
40
630
730 400
80
360
5,480
90
40
40
280
186140
297
728
3737
584
275
148
713
145
164
612160
67
64
80
551
864
2333
1,297
546
551
95
3,589
197
140
372
243
268
172
101
265
223
110
165
195
78
190
562
2
3
4
5
6
7
KJHGFEDC
BA
1
54
93
SS
S
S
S
S
SS
SSS
SS
SS
S
S
S
SS
SSSSSS
S
SS SS SS
SSSSSS
SS
S
S S S
S
S
S
S
S
S S S
S
SS
S
S
SS
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
E E E
EEE
E E
E
E
E
E E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
EEE
EE
EE
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
EE
E
EE
E
E
E E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
EE
E E E
S
S
S
S
F
S
S
S
S
S SSSSS
E
S S
S
S
S S
S S
S
SSS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
E
E
E
S
S
S
S
S
S
S
S
S S SS
S
S
S S S
S
SS
S
S
S
S SS
S
S
S
SS
S
S S
S
S
S
S
S
S
S
S
SS
S3
3
S3
S
S
S S3S
S
S
S
S
SSSS
S3S
S
SS
S
S
S
S
S3
LIGHT FIXTURE SCHEDULETYPEDESCRIPTIONPARABOLIC2X4 2-LAMP 32W T-8 FLUORESCENT RECESSED GRID MOUNTA6" 26W CFL RECESSED DOWNLIGHTEXIT SIGN - WALL OR CEILING MOUNTED EMERGENCY EXIT LIGHT WITH DUAL HEAD - WALL OR CEILINGMOUNTED. (CONFIRM SPACING WITH MANUFACTURER ANDFXG BCRTD4' 2-LAMP 32W T5 SUSPENDED FLUORESCENT SIMILAR TOALERA #CV42T5HMMODEL SPACING RECOMMENDATIONS)PARABOLIC 1X4 1-LAMP 32W T-8 FLUORESCENT RECESSED GRID MOUNTWITH ACRYLIC DIFFUSER 2X4 2-LAMP 32W T-8 FLUORESCENT RECESSED GRID MOUNTEEXISTING LIGHT FIXTURE TO RAMAIN6" 26W CFL RECESSED DOWNLIGHT SUITABLE FOR WET OREXTERIOR APPLICATIONJ6" 26W CFL RECESSED WALL WASHERPNS1120V, 26W CFL WALL SCONCE WITH PROTECTIVE GLOBE120V 60W MR16 HEADS ON WALL-MOUNTED RAIL: TECHLIGHTING #700WMARCHS CLAMPED ON WALL MONORAIL ORAPPROVED EQUAL WITH NUMBER HEADS AS SHOWN.24" LONG, 120V, 4-LAMP 50W G9 SCONCE: PHILLIPS FORECAST#F440236 WITH LIGHT POINTED DOWN. MOUNT END-TO-ENDWHERE MULTIPLE FIXTURES.120V, 13W CFL, PENDANT: PHILLIPS FORECAST #F510636U13WITH #F5145NV SHADE. MOUTING HEIGHT T.B.D.120V, 13W CFL, PENDANT: BRUCK #110-812-MC-IN-MP.MOUNTING HEIGHT T.B.D.120V, 4-LAMP 26W CFL, PENDANT: LUMINART "RDP" SATINNICKEL FINISH, METAL BRAID CORD, AND 36x11 SHADE.FABRIC AND MOUNTING HEIGHT T.B.D.S2 120V, 3-LAMP 13W CFL, PENDANT: LUMINART "RDP" SATINNICKEL FINISH, AND 16x6 SHADE. MOUNT AT CEILING.FABRIC T.B.D.