HomeMy WebLinkAbout0047 M601 HVAC Schedules.pdfFan Coil lJnit (Variable Refrigerant Volume) ! Capacity Electrical Connection Mark Air Volume ------- - - Unit Type Mitsubishi Modei High Speed Cooling Heating Disconnect g Fiiter Size Wei ht �N X EN Remarks (FCU-##) Voitage Phase MCA MOCP � � (CFM) (BTUH) (BTUH) by: (ibs) COS Ceifing Cassette P�FY - P08 NCMU-E 350 8,000 9,000 230 1 0.23 15 E.C. 34 - 4,3 �t2 Ceifing Cassette PLFY- Pt2 NCMU-E 390 42,000 13,500 230 1 0.28 15 E.C. 37 - 1,3 Di5 Conceaied Ducted PEFY - P15 NMHU-E 49Q 45,000 17,000 230 1 0.96 15 E.C. 98 24 x t2 x 2 1,2,3,4 D54 Concealed Ducted PEFY - P54 NMHU-E t420 54,000 60,000 230 1 3.43 15 E.C. 455 24 x 12 x 2 1,2,3,4 Notes 4. Provide fiooded drain pan interfock. 2. Buiid return air sub base 3. Provide digitaf seven (7) day programmable thermostat, unfess shown othenvise. 4. Fiefd fabricate fifter rack for 4" MERV 7 filter. Energy Recovery Ventilator Winter Supply Exhaus# Exhaust Summer Operations (°F) Operations Electrical Connection Renewaire Outdoor Air Static Static �F Weight Mark Model Volume Pressure A�r Pressure �� (Ibs.) Remarks �Ifl W.C.} Volume ��� W.C.} EDB EWB LUB LWB EDB LDB Voltage Phase MCA MOCP �` ERV-1 HE2XINH 1325 0.5 1200 0.5 95 78 8.3 70.7 -4 46.6 230 1 20.6 25 525 1,2,3 Notes: �� 1. Two direct drive blower; rrmotor packages. 2. Provide hanging vibration isolators. 3. Provide variable frequency drive. Lcsu�er AHU Greenheck Air SEatic Pressure Mark Served Model Volume (in w.c.) �12e rype Remarks {CFMj IAL-1 ERV-1 ESd-435 1325 425 30x18 Wall 1,2 EAl-1 ERV-t ESD-435 1206 .025 30x18 Wall 1,2 Notes � 1. Color by Architect. 2. Deliver to GC iar installation. . Sequence of Operations Terrninal Outlets Airflow Mark Function Price Range Face Size Neck Size Color Remarks Model (�F�} (in.) (in.} PD-2 Plaque Diffuser SPD 181-300 24 x 24 80 White 1,2,3 ER-t Exhaust Register 530 0-100 7 3/a x 7%4 6 x 6 White 1;2,3 ER-2 Exhaust Register 530 201-500 13 Sa x 13 3/a 12 x i2 White 1,2,3 RG-1 Return Grille 535 451-1000 25 %a x 13 %a 24 x 12 White 1,2,3 Nates: � 1. Provide factory extended panel for any diffuser which is smaller than the grid in which it is installed. 2. Provide plaster frame for diffusers, registers and grilles installed in gypsum board. Energy Recovery Ventilator (ERV-1) • Fans shall run continuously 24/7/365, • ERV shall operate with VFD controlled on duct static pressure. • Modulate wheel for frost protection and variable speed control. Fan Coil Unit (FCU-xx} • FCU shall operate via wall-mounted thermostat. • FCU shall run continuously during occupied mode. . FCU shall maintain a 72°F (adj) setpoint when occupied, . FCU shall be capable of occupied/unoccupied setpoint programming (Night Set Back). Motorized Dampers • Motorized dampers, both O/A and exhaust, shall open when CO2 sensor detects CO2 levels in excess of 900 parts per million (adj). • Motorized dampers, both O/A and exhaust, shall close when CO2 sensor detects CO2 levels below 700 parts per miilion (adj). Control System VRF System shall have a remote mounted centralized control panel that shall be capable of supporting schedule timers, system controllers, centralized controllers, an integrated web based inferface, graphical user warkstatican. Fleat Recovery lJnit (Variable Refrigerant Volume) Cooling Heating Eiectricai Connection Performance Performance Mark Space Mitsubishi Modei Nominai d Remarks Capacity Total Capacity Totaf Capacity Voftage Phase Disconnect (M6H) (M6Hj {V) �(.7� �iCA MOCP gy. HRU-t Generaf PURY-P144TSKMU-A i2 144 160 208 3 53 60 E.C. 1,2,3,4 Notes: � �� t. DC lnverter drive. 2. Ambient conditions: coofing 95°F, heating -14°F. 3. Mount on 14" equipment support raifs 4. High Heat option. Fabric [3uct Airflow Airflow Duct Duct Duct Mounting DuctSox DuctSox Suspension Mark Serves Range Total Length Diameter Height Color Remarks Material Dispersion �CFMILF) (CFM) (ft-in} (in) (ft-in) System Fabric Duct Rm. 108 Verona Comfort Flow 10 i420 56'-4"' 14 19'-0" 2-Row Selected by � 2 3 Architect Fabric Duct Rm. 109 Verona Comfort Flow 10 i420 56'-4" 14 19'-0" 2-Row Selected by � 2 3 i Architect Notes: 1. Duct lengths are approximate and for convenience only. Field verify all dimensions prior to fabrication. 2. Cobr samples to be submitted to Architect for color selection prior to fabrication. 3. Detailed duct design to be submitted to Engineer for review prior Eo fabrication. Electric Duct �csil Warren Electrical Connection Airflow Mark Tech Unit Served Duct Size {CFM} Remarks Madel Power Voltage (V) Phase (�} MCA (A) (KW) EDG-1 CBK FCU-708 14� 1420 11.2 208 3 31.0 1,2,3 EDG2 CBK FCU-109 14P 142b 112 208 3 31.0 1,2,3 Notes: i. See Sequence of Operations for control. 2. Fully Modulating Control 3. 24V Control fransformer tA � w w Z W Z J f/i Z � � f/i W J � W � Z 2 0 � �",� ��� Electric Wall Fleater Electrical Connection Mark prea MQd�r Type Disconnect Remarks �erV�f� Voftage Pawer (Watts) ��� Phase (f�3} MCA (A) EWH-1 Varies Raywall �y�61 Hea4er 1000 920 1 8.3 MFR 1,2 E3322TD-RP Nates: i. Fan forced heatar. 2. Integral T-Stat. 3. Recessed mount. '`�__._f-' c � E d . U U w w s � U � L d � l. ° No. PE10100f � STATE O F �.'_+.,_�NDIANP ., � . �� M � ]` �M ,� � i . r M 1 .. . �, « _ � � � iHE SCHNEIDER C�2PpRAY10N HistoriC Fort Horrison �90t Otis Avenue Indionopolis, IN 462i6-t037 Telephone: 3t 7.�26.7t 04 Fox; 3t 7.826.7200 www. schneidercorp.com ArChiteCture Civil Engineering Environmentol Engineering Geo4tchnicoi Services GI$ s LIS Home Builder Services Interior Design Lond Surveying Londscope Architecta�re Yronsportotioin Engineering � 1 1 � �' 1 1 1 � .� � J � � � u 2 I C� I F-- ' Q w � ' v� w� tY ° � -,� � � cn - �J LL, <L � �� � `� C� t= � Q u' �� <t �a O� �� �- <t w �_ v �- �� w � � �