HomeMy WebLinkAbout0052 E701 Electrical Details and Symbols.pdf� -- � - �__ --�— __ -_�_. - �_______ _ �_�� � — - _ ��
�
� �
w �°'
��
Structure above� W �� a
Z :� E
L . __ �.�..__ . _..._ _..__._.� /R � 3
_ .. _. . _..__ _ i �/
Ele�tri�al Syrnbols Legend _— _ _--- �_- - - --- -----� --==i-- � � .
Lighting outiet box Z �
� Single plex receptacle and support E- �� „
� J 2X4' fluorescent light fixture Flexibie rod by E.C. J„�, �
� �� �
� Fioor mounted duplex receptacle b° E �k �/i ��s �
Y "� Z �`4'%,, a�
2'x4' fluorescent light fixture with emergency battery backup (switched) �t 0�,, _
enn Duplex receptacle mounted above counter or sink. Coordinate with fumiture prior to (3 *'� w
:
� installation N `�S
?_'x4' fiuorescent light fixture with emergency battery backup (non-switched) W�� '
EMiNt Ceiling T-bar �;
N �j Special purpose receptacle as noted on drawings J �� -
Ceiling � �y,� °
� � 2'x4' fluorescent light fixture (non-switched) � � � 0 d � � IjJ \� _
� � Power pole L— - — �- �" !'�— -- '� m �� m
_ i
Lay-in type 0 v� r
__ __J 1'x4' fluorescent light fixture fixture by E.C. Ceilin T-bar � Z�'�� °
� 208!120V. Panel �oard Notes� 9 Lay-in type 4„� �,
1. Lighting fixtures must be supported light fixture � ���
� 1'x4' fluorescent light fixture with emergency battery backup {switchedj independently of ceiling system. � 0�
enn Upon written request to the
� 48Q/277V. Panel Board engineer, other means af support ��
p_I 2`x2' fluoresaent light fixture will be considered tor approvaL _ �., ���>�
"C`x%l��a �a�W
�M Motor connection 2. Light fixture shown may not depict PP P{ p j Planl
� specific attributes of fixture being Su ort cli s 4 er fixture . View
2'x2' fluorescent light fixture with emergency battery backup {switched) utilized in this project. Refer to Like Caddyr� lay-in and trofter �;a
Ef� � Fixture Le end on Architedural `�'a`� 4
Kitchen rough-in 9 Eight fixture support clips ��4�'�
R e f l e c t e d C e i l i n g P l a n f o r f i x t u r e
� 4' long tluorescent strip light fixture information.
� Dry-type transformer
i � Downiight
� Plug stnp
�� Downlightwithemergencybatterybackup(switched) 3 TYPiCAL �Q I-iN FIXTURE �UPPORT DETAiL
Fire and Communication E7oi �ALE: NONE
r� Wall mounted incandescent or compact fluorescent light fixture Q Fire alarm pull station
t-� Wall mounted H.I.D. Light fixture � Combination fire alarm pull statioNhorNstrobe
� Ceiling mounted exit sign �
Combination iire alarm horn/strobe
-- Panel designatian
� � Wall mounted exit sign � Fire alarm strobe light
— Ground conductor(s) (if used)
� Wall mounted emergency lighting unit � �
Fire alarm smoke detector
Phase conductor(s)
Switches
F{� Fire alarm thermal detector Neutral conductor(s)
� Single pole switch � Switch leg or Go-behveen
� Fire alarm duct detectar _�i _
�
�3 Three-way switch ��
F'P`�'P Fire Alarm Control Panel �
� Four-way switch A�1-1 ,3,�J All conductors #12 AWG
otherwise noted
r.v.e. Telephone Terminal Board
¢_ Wall switch type duaf technology occupancy sensor. Refer to Manufacturer's All conduit 3/4" unless
+�� instructions for exact installation requirements prior to rough-in. otherwise noted
� Telephone outlet location, 1" conduit with pullwire to above accessible ceiling
��i Wallicorner mounted dual technology occupancy sensoc Refer to Manufacturer's Circuit No. designation
'�i instructions for exact installation requirem�nts prior to rough-in.
- Ceiling mounted, omni-directional type dual technology occupancy sensor (standard � Telephone/data outlet location, i" conduit with pullwire to above accessible ceiling
i!, �� range). Refer to Manufacturer's instructions for exact installation requirements prior �Ot2S:
\�
-- to rough-in. �
'" � Ceiling mounted, omni-directional type dual technology occupancy sensor (extended Data outlet location, t" conduit with pullwire to above accessible ceiling t. #12 AWG is min. conductor size except as noted.
((; 1��1 range}. Reier to Manufacturer's insiructions ior exaei installation requirements prior 2. 3/4" eonduit Is min. Size except as capacity
��� to rough-in. permitting 24 valt controf conductors and switchlegs
F-Q Microphonejack �
may be in t/2" size: others as noted.
Occupancy sensor manua! override switch (no sensar}. 3. 112" is min. Flexsteel, Greenfield and Sealite size.
� Reier to Manuiacturer's instructions for exact installation requirements.
6-+t Call back
� Momentary contact switch
(�S Ceiling speaksr
,�jp Single pole switch with pilot light 2 K EY TC? E L. ECT R I CA L. C I RC U I T W I R I N�
i..� Wall m�unted speaker ���� SCALE: NONE
� Dimmerswitch
� Magnetic hold open
� Fusable switch
F{c� Clock locatlon
�� Switch wiih thermal overloads Connection to structural 3!0 CU 3/0 CU Connection to cold
� C.A.T.V, location sieel oi building �� � water system
,�
r-M Keyed push button kill switch
i (%II'CUltlllg _____. 3(0 CU To concrete encased electrode (in min. oi 2" wncrete
---� � within or near bottom oi ioundation/footing with min. of
Disconnect switch 20'-0" oi bare copper conductor not smaller than #4 AWG.}
� /,,.----` Conduit system concealed above ceiling
� Motor starter Surface mounfed conduii system �
---- Neutral bus
� � Disc. Link � At Main Switchboard (MSB}
Combination motor starteridisconnect v — Equipment ground bus �
o �
� — — — Conduit system under floor �
POWeI" ��"� Nomerun. Conduit system to panel as noted on drawings �Surge arrestor
� Duplex receptacle ��
�J Junction box �— (3} 3!4" copperweld 10' long
ground rods
� Duplex receptacle horizontally mounted
Contractor shal! ver'rfy with local
�}-- Conduit up
3/0 CU gas company for gas meter
� t7uad receptacfe grounding if required.
♦--- Conduit down To dry transformer(s} Gas meter Water meter
� Ground fauft interrupt receptacie � Cald water pipe
Note �
c� Note:
� Weaiherproof, ground fauii interrupt receptacie Not alf symbois listed above are shown on plans. �,°�, E.C. shall foflow this detaii for proper
W�' , grounding connections.
The symbol {egend is used for reference of —� � 3;0 CU shunt around gas meter
� Combination tamper resistant duplex receptacfe and USB (Unrversal Senal Bus) symbofs shown on plans. See specifica4ions for 3!0 CU to gas meter
� char tn � � information related to symbofs. � �
g' g ports fike Cooper #TR7748
3I0 CU 310 CU to water meter 3t0 CU shunt around water
10' Min. meter
(Typ. for 3 cr 4 rod grounding field}
� GROUNDING DETAlL
E70i 5GALE: NONE
f � No.
PE10100i
�STATE O F
hVDIANP
,. ,� ,-�
� «-
;����� , �
«. ,.' - i
�.�� r
,
., �� �r ���
«. ,_,.
�.�
THE SCHNEIDER CORPORATIpN
HistOriC Fart Horrison
89mi OFis Avenue
Indionopolis. IN 46216-1m37
Teiephone: 317.826. 79 QO
FO%o 317.$26.72Q0
www.schneidercorp,com
Architecture
Civil Engineering
Environmentol Engineering
Geatechnicol Ser,rices
GIS • US
Home Euilder $ervices
Interior Design
Lond 5urvepng
Londscope Architecture
Tronsportation Engineering
% �
O � �
— � W
�� ��
�- 4 n °
4 -�' .
LL Q- � z
� .�
� � � �
ti/ � L3 n-- Q
s-�- w Z � U
� � -} � w
Q— � a �
� � H
�t� � �H
f`e
� � �s
fl � `� �,
� �
Z U �
� L� W
O � �
� � U