Loading...
HomeMy WebLinkAbout05120011-Signed conditionalPERMIT PLAN REVIEW STOPS PAGE ! P~RMIT NUMBER' 05120011 - DARRY WEAVER TYPE: RESREMODEL PARCEL ID i 1610210015012000 PARCEL ADDRS i 14587 WHITE HALL CIR CARMEL. IN 46033 PPLY DATE [ 12/01/05 ISSUE DATE : C O DATE : ONTRACTOR : WEAVER, DARRY HONE NUNBER : (317~ 847-4588 FAX NUMBER : 1317 848-239 REVIEW STOP ---~ ....... ~-~-~~-~ ....................... REV NO 1 STATUS: C DATE 12/12/95 CONT ID: REVIEW SENT BY: aschrine DATE: 12/12/05 TIME 08 57 TIME SPENT: REV RECEI~D BY: aschrine DATE: 12/06/05 TIME: 98:47 SENT TO: S REVIEW NOTE 2005-12-12 09:00:10 Conditions of Derml~: Smoke detector needed in basemen~ bedroom, at bottom of basement stairs and to current code throuchout entire house to current code (see handout and inform electrician of this state ENCOMPASS - Pentamatlon permit.4ge (permit5.4gl) RUN DATE:12/12/05 Section R3131 smoke alarms. SMOKE ALARMS 2005 Each smoke alarm shall be listed: R313.2 Required smoke alarm locations. At least one smoke alarm shall be msralled in each of the following locations In the living area remote from the kitchen and cooking appliances, Smoke alarms located within 20 feet horizontally of a oking appliance must incorporate a temporary silencing feature or be photoelectric type. In eacl~ room designed for sleeping. On the ceiling of the upper level near the top or above each stairway other than a basement stairway, in any mulfistory ,elling. The alarm shall be located so that smoke rising in the stairway cannot be prevented from reaching the alarm by an ervening door or obstruction. On the basement ceiling near the stairway. R313.2.1 Alterations and additions. When interior alterations or additions requiring a permit occur OR when one or more sleeping rooms are added or created in existing dwellings, the individual dwelling unit shall be provided with smoke alarms. ired for new dwellings. The smoke alarms rd wired. R313.5.2 Interconnection~ When more than one sm.0ke alarm is required to be installed within an individual dwelling unit, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the individual unit, EXCEPTIONS: t. Smoke alarms in existing areas shall not be required to meet the requirements where the alterations do not result in the removal of the interior wall or ceiling finishes exposing the structure unless, there is an attic crawlspace, or basement available that could provide access for hard wiring and interconnection without the removal of interior finishes Repairs are exempt fi'om the reqmrements of this section. R313.3 Prohibited smoke alarm locations. A smoke alarm required under this section shall ~ot be placed 1. Within 3 feet horizontally from any grille moving conditioned air within the living space or 2. In any location or environment that is prohibited by the terms of the listing, R313.4 Mounting requirements. Smoke alarms according to their listing installation instructions and the reqmrements o:~' this secrloo. R313.4.1 Flat Ceilings. In rooms with flat, peaked sloping or stngle slope ceilings with a slope of less than 1 5/ 2 smoke alarms shall be mounted either: L On the ceiling at least 4 inches from each wall; or 2~ On a wall with the top of the alarm not less than 4 inches below the ,ceiling and not farther from the ceiling than 12 inches or the distance from the ceiling specified in the smoke alarm manufacture s listing and installation instructions, ~vhichever is less. R313.4.2 Peaked Sloping Ceilings. In rooms with peaked sloping ceilings with a slope of 1.5 12 or greater, smoke alarms shall be: 1. Mounted on the ceiling or wall within 3 feet measured horizontally, from the peak of the ceiling 2. At least 4 inches measured vertically below the peak of the ceilix~g; and 3. At least 4 inches from any projecting structural element R313.4.3 Single Slope Ceilings. In rooms with single slope ceilings with a slope of 1 5/12 or greater smoke alarms sba i be 1. Mounted ~h the c~iling or wall within 3 feet measured horizontally, of the t~igh point of th~ ceiling and 2, Not closer than 4 inches from any adjoining wall surfaces or any l~rojecting structural element. R313.4.4, 313.4.1,313.3.2 Visible and tactile notification appliances. SEE CODE. R313.5 Connection to Power Source. Each smoke alarm shall be powered from 1~ The electrical system of the home as the primary power som'ce a~d a battery as a secondary power source; or 2. A battery rated for a 10 year life, provided the smoke alarm is listed for use with a 10 year battery. 1t313,5.1 Circuitry. Each smoke alarm whose primary power source is the home electrical system shall be mounted on an electrical outlet box and be connected by a permanent wiring method to a general branch circuit,