HomeMy WebLinkAbout05120049-Signed conditionalPERMIT PLAN REVIEW STOPS PAGE 1
PERHIT NUMBER: 05120049 - PAUL & LINDA PETTENARO TYPE:
PARCEL ID : 1713090009014000
PARCEL ADDRS : 10351 WINDEMERE DR CARMEL. IN 46032
APPLY DATE 12/08/05 ISSUE DATE : C/O DATE :
CONTRACTOR : MCG-LLC
PHONE NUNBER : 317/ 53~-7307 FAX NUMBER :
RESACCESS
317} 535-981
REVIEW STOP: BLDG - BUILDING INSPECTOR REVIEW
REV NO: 1 STATUS: C DATE: 12/12/05 CONT ID:
REVIEW SENT BY: qochs DATE. 12/12/05 TIME.' 11:07 TIME SPENT: 0.()
REV RECEIVD BY: lochs DATE: 12/08/05 rIME: 11:07 SENT TO:
REVIEW NOTES: 2005-12-12 11:15:08 CONDITIONS OF PERMIT:
t Entire masonry fire place to De set
on min. 12 inch thick foeEer.
2 A 3/4 inch air space shall be
mamntained between the brick and
sheathina.
House wrap shall be installed on the
she~thina.
Weed holes shall be spaced no more ~nan
33 inches aparT.
3 All wa~er SUDDlV DiDlnc and wasEe
uiuinc UNDERGROUND mu lnsDec~et
prior to placement of fill.
CONDiTiONAL
ENCOMPASS - Pen~amanlon perml~.4ge [permit5.4gl RUN £ATm.=z 12/05