HomeMy WebLinkAbout05110099-Site PlanThe Schneider CorlMraUon 8901 Otb Aven~e Surveyil2i 3 f 200400080247 (SO'R/W) IN 46074 10' (B.H.) Rnished Floor Elewtion InformoUon Pod C-rode = 912;5 per plun Pod Grade + 0.7, Garage FFE + 1,5 Resldentiol FFE - 10.d'~= Basement BE (~0'~.7) Note [ 1he garage finished floor devotion is 2.3 above the curb at the drive, per plan. C, round Cover Calculations: Ddve= 1,341SFJ: Public Walk =171 SF+ Priwte Walk =198 Hydroseedihg =4,842 Sod = 498 SY+ , from Rear of residence. Sidewalk to be placed 1' from property line, 4' from bock of curb, per plan. Note: Sanitary Sewer Top of Costing Informution Upstream Manhole, TC=911.5,~ D~wnstream Manhole, T0=912,21 per record drawing 29,3' FLOOD HAZARD STATEMENT BERllFICATtON S0305 711111fififilgJll~\\\%'~ Note: This drawing is based on :onstrucfion plans or record drawings, and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this ~nformotion. Contractors should verify existing conditions prior to any construction. Any discreooncy found on this drawing should be reported to The Schneider Corporufion immediately;* foiflng to do so results in the contractors assumption of all lishility, qote: the basement elevation, depicted hereon, has be~ determined ~nd based upon the pad grades esd/or c0~tours taken from the constrdctior plans for this subdMsion. Unless stated, no information about fluctuating water tames, soil conditions, or soil types has been provided or stated on said pless. It is recommended that the basenent finished floor olevotions be at Isest two feet (2') above the normal pool e~evotion of any adjoining bed~ss of water unless a study of facts reve(ds other~dss. If during the excavoUor process any ground water is witnessed, The Schne der Corporotion should be nottfied,immediate~y. The basement elevot on sh~ d be rolsed two feet (2) above the ground water, and additional construction tecl{nt~ues should be incorporated to oileviate future problems. Vb05.0037704 0 Lot # 216 Assumed Nord Scale: 1" = .'.'~' Detail of C<o~nd/Storm Water flow pattern for hdlvlduot lots, Note: Buider to ensure positive drainage away from structure(s). Note: Sump pump(s) to be Caced by builder as needed. ._88__.95_' -- __ 10' DU&SE !5.0' Flood Hazard Statement: The accuracy of any flooo hazard data shown on this report is subject to map scale uncertainty and to any other uncertainty in Iocanon or elevation on the referenced flood insurance rate map. ALL Of the within described land DOES NOT lie w h n hat special flood hazard zone AE as said I~nd DIets by scale on flood nsuranca rate map #180081 0205 F for the City of BY CUSTOMER, REVISION 11 ADDED 'tFI' BUMP TO GARAGE Vo05.0038677 e(~] C8216 29-20904 Od/to/e5 A~A RDaS~ON ~2 NEW HOUSE MODEL Vb0,5.0044t 60 PO t 2g-23725 n/~3/o~ AaA Note: Per Cormel zoning ordinance 26.1.1: The rseklentiol district limits height to twenty-five feet (25'), howeve~ a dwelling may be inerecmed in height to thirty-riva feet (35') provided the side and rear yards are increased an additional o~e foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in height.