HomeMy WebLinkAboutATC-E1 1.pdfSMOKE DETECTOR, 120 VOLT, WITH BATTERY. INTERCONNECTED
SYSTEM FIRE ALARM HORN / STROBE WEATHERPROOF
SYSTEM FIRE ALARM HORN / STROBE
SYSTEM FIRE ALARM PULL STATION
WP
G
DUPLEX RECEPTACLE
30 AMP RECEPTACLE, 240V
SINGLE POLE SWITCH
THREE WAY SWITCH
DISCONNECT
TELEPHONE, TV, AND DATA, (1) RG-6 Coax, 2-Cat5E
1S
3S
E1.1 FIRST FLOOR LIGHTING PLAN AND ELECTRICAL SCHEDULES
E1.2 FIRST FLOOR POWER AND SYSTEMS PLAN
30
SWITCHED RECEPTACLE, TOP HALF OF RECEPTACLE
TS TIMER SWITCH
GFI RECEPTACLE
WEATHERPROOF GFI RECEPTACLEG
50 AMP RECEPTACLE, 240V50
DEDICATED DUPLEX RECEPTACLED
J JUNCTION BOX
BB Sprinkler Room w/THERMOSTAT. TPI E3321T20-RP
w/3310 Rough In Box
UH ELECTRIC WALL HEATER w/THERMOSTAT: TPI
F3326T20-RP w/ 3320 EX33 Box
TV Location (1) RG-6 CoaxTV
SYSTEM SMOKE DETECTOR WITH RELAY BASE.
SYSTEM SMOKE DETECTOR
R
A
A
IN UNITS
WP
FIRE ALARM SYSTEM CONTROL PANEL
FIRE ALARM SYSTEM ANNUNCIATOR PANEL
TS
FS
TAMPER SWITCH MONITOR MODULE
FLOW SWITCH MONITOR MODULE
FOUR-WAY SWITCH4S
TELEPHONE AND DATA
DB
Door Bell Button
Door Bell Chime
V Strobe Only
Trans Transformer By Utility Company
1. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS AND ONE YEAR GUARANTEE COMMENCING ON DATE OF
PROJECT ACCEPTANCE.
2. VERIFY LOCAL CONDITIONS AT SITE.
3. COMPLY WITH ALL APPLICABLE CODES.
4. SECURE AND PAY FOR ALL REQUIRED PERMITS AND SUPPLY TO G.C. PRIOR TO STARTING WORK.
5. ELECTRICAL SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE N.E.C.. SYSTEM SHALL BE GROUNDED TO THE COLD WATER SERVICE
AND TO THE BUILDING STEEL. FURNISH AND INSTALL A GROUND JUMPER WIRE ACROSS WATER METER.
6. ALL CONDUCTORS SHALL BE COPPER.
7. FURNISH AND INSTALL TYPE TRITTEN PANEL DIRECTORY. IDENTIFY AND LABEL ALL ELECTRICAL SERVICE EQUIPMENT INCLUDING METERS WITH UNIT #'S AND ADDRESS.
8. CONNECT TELEPHONE AND TELEVISION SYSTEMS PER LOCAL UTILITY REQUIREMENTS VERIFY LOCATION AND TYPE OF EQUIPMENT REQUIRED WITH ARCHITECT AND OWNER.
FAN Circulating Fan by Mechanical Contractor, Provide Dedicated Circuit.
1. AT THE MINIMUM: OFFICE SHALL HAVE 2 DUPLEX
AND 2 DATA. VERIFY LOCATION WITH OWNER.
2. ALL CIRCUITS WILL BE RAN FROM EXISTING
CIRCUITS IN MECHANICAL ROOM 122 AND 125.
H Horn Only
W-H Wall Heater
F3 F3
F3
F3
F3
F3
F3 F3
F3
F3
F3
F3
F3 F3
F3 F3
F1
F1
F1
F1 F1
F1F1 F1 F1
F1F1
F1F1F1
F1F1F1
F1F1
F1
F1 F1
F1
F1
F2
F2F2
F4 F4A
M
1
1
1
1
1
1
2
2
FI
R
S
T
F
L
O
O
R
LI
G
H
T
I
N
G
P
L
A
N
MU
92
$
#
$#
&'5%4+26+10 '
E1
.
1
25
5
E
a
s
t
C
a
r
m
e
l
D
r
Ca
r
m
e
l
,
I
N
4
6
0
3
2
Co
o
t
s
,
H
e
n
k
e
&
W
h
e
e
l
e
r
Me
d
i
a
t
i
o
n
W
i
n
g