Loading...
HomeMy WebLinkAbout05120057-Site PlanThe Sehseae~' Co~j~'aUon ~ 8901 Otis Avenm ~ lnd~mpob, ledtmm 46~1e-io3~ ~ · US 'lhb Lot ting 5.318 ~ 577 CI[RIFICAIE of CORRECllON 3513 Cannel, IN 46074 Prepared Dote: 12/05/05: By:, AMA ~ Buyer(e): Charles & Jonice Huntwork Commsunlty R,estrictione: Side Yard ~5 min. Rem Yard = .N/A,. Aggregate = 6 (B.H.) R,N of indiana Finished Flcor Elevation Information Pad Grade = 915.6 per plan Pod Grade + 0.7' = Garage FFE (916,5) Caroge FFE + 1.5' = ,ResidenUal FFE (9178) ResidenUal FFE - 9.0 = Basement FFE (908.8) Note: The garage fialched floor elevation ~e 1,7' abow the cum et the drive, per plan. S.F.:t:, in ~ Proposed erodes 000.0 Existing Grades ...---000.0---" Contour Credo ~< Approx. Lateral LocoUon '----.- · ~ Sanitary Sewer Lines · --,--~1'----,-, Storm Sewer Lines _-__ _v ~ Water Service Lines ..... Sub-Surface Oran Lnes · Manhole (Sap tory or Storm) _~ Beehive ~r~let (Stain) las Curb Inlet (Storm) D End Section (Storm) .~. Fire Hydrant ......... Row Line of swdle I ~ Building Line (BL / 8SL) Note: Son tory Sewer Top of Costing Information Upstream Meshole, TC=917.40 Downstresm Manhole, TC=915.30 per plan. Ground Cover Colcuiatians Drive = 535 SF+ Public Walk =147 SF:h Private Walk =55 SF'+ H)droseeding =n/a Sod =285 SY:t: , from entire yard TC~917.40 Note: This drawing is based on construcUon Plans or record drawings, and is not based upon o field ~urvey, The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should v~fy existing conditions prior to any construction. Any disoreponcy found on this drawing should be r~brt~ to The Schneider Carparotion immediately; failing to do so results in the contractors assuirsption of all liob~ity. Note: Par Carmel zoning o~dinonce 26.1.1 The residential district limits height to twenty-fl~ feet (25'), I~owever a ,d, welling may be increased in height to thirty-five feet (35) pro~ided the side and rear yards ere lac~onsed on edaltlonal one font (1') far each one font (1') the structure exceeds the first twenty-five feet (25') ~n height. Lot # 10 Vb05,0045262 Detsil of ~und/Storm Water flow sattern tm led~v~du=l Iot~ ~med Note: Builder to ensure positive drainage away from structure(s). Note: Sump pump(s) to ne pieced by builder as needed. Sidewalk to 1' from property line, 22.5' 4' from bad( of curb. per pron. OSINP y~OA KEY I.~0 B FI~&~SY :~ REStOENCE 15' D.E 45.oo' ~C.A. //1 ~ O.U.ckS. S,E,k LM.A.E,~R.D.E. & PJ.E.E. ~ The basement elevetiar,, depicted herenn, has been determined and boesd upon the pad grades and/ar contours t~on from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables. ~o~ condition~, or soll types has been provided or stated on acid plans, It is recomirsonded that the basement finished floor elevations be at least two feet (2') above the normal pool e~evetkm of any ad,binlng boales of water, unlees o study of facts revonm oth~ If during the excavation proness any ground water is wltn~ed, The Schneider Carporat~on ~onld be notified iirsirsediate~y. The ba~'nent elevation ~ould be raised two feet (2') above the ground water, and additional conetraction techniques chonld be inonrparat~ to afie~ate future prabtome. FLOOD HAZARD STATEMENT CERTIFtCA]ION .... No.