HomeMy WebLinkAbout05120057-Site PlanThe Sehseae~' Co~j~'aUon ~
8901 Otis Avenm ~
lnd~mpob, ledtmm 46~1e-io3~ ~ · US
'lhb
Lot ting 5.318
~ 577
CI[RIFICAIE of CORRECllON
3513
Cannel, IN 46074
Prepared Dote: 12/05/05: By:, AMA
~ Buyer(e): Charles & Jonice
Huntwork
Commsunlty R,estrictione:
Side Yard ~5 min.
Rem Yard = .N/A,.
Aggregate = 6 (B.H.)
R,N of indiana
Finished Flcor Elevation Information
Pad Grade = 915.6 per plan
Pod Grade + 0.7' = Garage FFE (916,5)
Caroge FFE + 1.5' = ,ResidenUal FFE (9178)
ResidenUal FFE - 9.0 = Basement FFE (908.8)
Note: The garage fialched floor elevation
~e 1,7' abow the cum et the drive, per plan.
S.F.:t:, in
~ Proposed erodes
000.0 Existing Grades
...---000.0---" Contour Credo
~< Approx. Lateral LocoUon
'----.- · ~ Sanitary Sewer Lines
· --,--~1'----,-, Storm Sewer Lines
_-__ _v ~ Water Service Lines
..... Sub-Surface Oran Lnes
· Manhole (Sap tory or Storm)
_~ Beehive ~r~let (Stain)
las Curb Inlet (Storm)
D End Section (Storm)
.~. Fire Hydrant
......... Row Line of swdle
I ~ Building Line (BL / 8SL)
Note: Son tory Sewer
Top of Costing Information
Upstream Meshole, TC=917.40
Downstresm Manhole, TC=915.30
per plan.
Ground Cover Colcuiatians
Drive = 535 SF+
Public Walk =147 SF:h
Private Walk =55 SF'+
H)droseeding =n/a
Sod =285 SY:t: , from
entire yard
TC~917.40
Note:
This drawing is based on construcUon Plans or record
drawings, and is not based upon o field ~urvey, The
Schneider Corporation does not warrant the accuracy or
sufficiency of this information. Contractors should v~fy
existing conditions prior to any construction. Any
disoreponcy found on this drawing should be r~brt~ to
The Schneider Carparotion immediately; failing to do so
results in the contractors assuirsption of all liob~ity.
Note:
Par Carmel zoning o~dinonce 26.1.1
The residential district limits height to twenty-fl~
feet (25'), I~owever a ,d, welling may be increased in height
to thirty-five feet (35) pro~ided the side and rear yards
ere lac~onsed on edaltlonal one font (1') far each
one font (1') the structure exceeds the first
twenty-five feet (25') ~n height.
Lot # 10
Vb05,0045262
Detsil of ~und/Storm
Water flow sattern tm
led~v~du=l Iot~
~med
Note: Builder to ensure
positive drainage away
from structure(s).
Note:
Sump pump(s) to ne pieced by
builder as needed.
Sidewalk to
1' from property line, 22.5'
4' from bad( of curb.
per pron.
OSINP
y~OA KEY I.~0 B
FI~&~SY
:~ REStOENCE
15' D.E
45.oo'
~C.A. //1 ~
O.U.ckS. S,E,k
LM.A.E,~R.D.E. & PJ.E.E. ~
The basement elevetiar,, depicted herenn, has been
determined and boesd upon the pad grades and/ar
contours t~on from the construction plans for this
subdivision. Unless stated, no information about
fluctuating water tables. ~o~ condition~, or soll types
has been provided or stated on acid plans, It is
recomirsonded that the basement finished floor
elevations be at least two feet (2') above the normal
pool e~evetkm of any ad,binlng boales of water, unlees
o study of facts revonm oth~ If during the
excavation proness any ground water is wltn~ed, The
Schneider Carporat~on ~onld be notified iirsirsediate~y.
The ba~'nent elevation ~ould be raised two feet (2')
above the ground water, and additional conetraction
techniques chonld be inonrparat~ to afie~ate future
prabtome.
FLOOD HAZARD STATEMENT
CERTIFtCA]ION
....
No.