Loading...
HomeMy WebLinkAbout05120078-Site PlanaS'IR, jl 200500009385 P.C.t 3, aw # 577 CERI'd:ICA1E of [:~{REC110N 3488 Mitlbrae Drive (50'R/~ Prepared Date: 12/07/05. By, AMA prq3~Nled Buyers): Jay & Courtney Simpkiss Community R~trlctt~s: Side Yerd =3 mtn. Rent Yord = ~N/,A. Aggregate = 6 (9,N.) R.H. of Indiana Finished Roar Elevation information ItH. of In'aa F~lot Plan L--~gend S,F,+, in ~ Proposed Grades OOO.O Existing ~rades ..-----000.0---" Contour Grade N< Approx. Lateral Location -==-- S ~ Sanitary Sewer Linen -..-,.--at Storm Sewer Unes -- v ~ Water Service Unes ....... Sul>-serklce Drain Lines ~ Uonhale (Sanitary or Storm) ~ Beehive Inlet (Storm) [] Curb inlet (Storm) D End Section (Storm) oooAooo Fire Hydrant ...... Row Line of swale ~ Building Line (BL / BSL) ....... Eanemont Line Note: This drawing is based on construct on plans or record drawings, ~d's not based upon a flea survey. 1lie Schneider Corporotinn does not warrant the accuracy or sufficiency of this information. Contractors should v~rify existing conditions prior to any construction. Any discropescy found ~n the drawng shoud be reported to The Schneider Corporation immedistay, falling to do so results in the contractors ensumptian of all linbility. Detail of G~ound/Storm Lot # 88 Vb05.0045736 Note: Builder ts ensure I positive drainage away from structure(s). ~=,~ Note: Sanitary Sewer TOP of Casing nformatinn Ul~:stresm Monhaleo TC=916.30 Downstream Manhole, T0=917.30 per plan. Assumed NorUI Scale: Note: The basement aleutian dop~ctsd hereen~ has be~ Pad (Trade = 916.4 per plan detmmined and boned upan the pad grades enfi/or centaurs Pod Grade + 0.7' = Garage FF[ (917.) taken from the censL'uct~ plans for thls subdivision. Unless Garage FFE + 1.5' ~ Resjdmfflo{ FFE (918.6) ~tatsd, no informal~ obont fiuctuutinfi water taben, soil Residential FFE - 9.0' ~ Basement FF£ (90~).6) conditions or soil types hen been provided or stated en enid t~ons, It is recommended thut the basement ~tshed floor Note: me 9erege finbhed floor aleutian eisvetlane be at le~t two foot in t.6' above the cum at the ~, per plan. alevetlon of any od.}oining bodies of water, unless a study of fac[~ revenle otherwise. If dur{n9 the excavot{on process eny ~ound Cover Calcu{atinns ground water {s w{thessod, ]he Schno{der Corporation should Drive = 795 SF+ be notified Immed?,teiy. The Public W~alk =441 SF~: raised two feet construction techniques shenid Prints Walk =45 Hydresesding =2,391 SF+ ~uture ~r~blems. Sod =404 SYt . from Note: Rear of renideace Sump pump(s) to be placed by / builder as needed. ?!dewalk to be placed Note: 1 from property line, The contractor is to maintain a minimum 4' from bock of car~, distance of ten feet (10') between the per plan. sanitry sewer and water IL~o laterals. Note: Per Cmme~ zoning ordinance 26.1.1: The rooidooNol district timtts height to twenty-five feet (25'). however e .al, welling may be increased in height to thirty-five feet (55) provided the s!d,e and rear ore ieareen~ en additional one font (1) for ea~ one feat (1) the structure exceeds the first twenty-five feet (25') in height. FLOOD HAZARD STATEMENT CERTIFICATION I ~m OF RECEIPT OF PLOT ? BY CUSTOUER. RAE DRII --1