Loading...
HomeMy WebLinkAboutLighting General Information - Poles (Poles are available only in U.S.) Environmental Conditions Allluminaire / pole assemblies require proper evaluation to ensure that th e structural integrity of the assembly is not compromised when applied in specific wind conditions. Therefore, the basis for pole selection in this catalog is total weight I EP A, national wind zones and local wind conditions. Local conditions to be aware of when selecting a pole, is the presence of steady relatively low speed wind (10 - 30 mph), topography and the structure the pole is installed on. Thesecondi- tions can' enable second mode vibration to occur, which results in material fatigue and ultimately pole failure. Straight square poles under these conditions may have a higher incidence of failure, but all pole types can experience second mode vibration. Currently, there is no method to predict second mode vibration, but there are certain locations and conditions that increase the likelihood of it occurring. · Low steady winds (10 - 30 mph) · Top of parking decks · Airports · Bridges · Mountain foot hills · Large expanse of flat ground · Low EPA load on pole · Pole height of 25' and above · Pole installation without luminaire This is not a complete list. Other factors can cause second mode vibration. If vibration is a concern or an existing installation is experiencing second mode vibration, there are dampening devices that can minimize the potential for pole failure. There are many different dampertypesthata"bsorb orcounter actthe vibration inthe pole shaft. EPA on.Luminaire Specification Sheet Dimensions are shown in inches (centimeters) unless otherwise noted. EPA3 S qua re Height Arm length Max. weig ht KC 1.2 ft2 (.11 m2) 17-1/2 (44.5) 7 -1/8 (18.1) 4 (10.2) 421bs. (19.1 kg) Figure 1 Warranty If during the pole warranty period of one year,' the product proves defective in material, workmanship, the company shall correct, at its option, by repairing or replacing at no charge to the purchaser, if the purchaser promptly notifies the company. This 'warranty specifically excludes fatigue failure or similar, phenomena associated with wind and/or structural induced vibration. Step 1. Step 2. Step 3. , Step 4. Step 5. Step 6. L(;~;(l.. Pol'e ,Selection Procedure Select the luminaire and. determine the quantity required per pole. Calculate the Effective Projected Area (EPA), which is located on the luminaire specification sheet. For multiple luminaire assemblies, refer- ence the EPA chart on PL-115 or visit the product selection guide on- line at Lithonia.com for the most up to date information. Determine the appropriate mounting method for the luminaire and calculate the EPA, Figure 1. If the standard mounting option is selected the EPA is included in the luminaire EPA. Only it an optional mounting method is selected must additional EPA be calculated, (bullhorns, non- standard arms, etc). Add together the total EPA's of the luminaires and mounting method along with other attachments (banners, wires, signs, etc.). Consult the wind map on PL-l00 to determine the appropriate wind zone for your area, reference the project specifications and consult local building codes. Also consider any local environmental issues which could cause second mode vibration. Determine the pole material and shape that is required. Refer to the "T echnicallntormation" table, Figure 2, for the following: · Select the nominal mounting height · Select the appropriate wind zone . Selectthe EPA that is equal to or greater than the EPA from step 3. · Cross check that the total weight of the luminaires and mounting options does not exceed the designed maximum weight of the pole. Caution: This pole selection process is a guideline only. Lithonia Lighting assumes no responsibilityfor selection and recommends consultation with a qualified local individual. Return Policy Poles are not returnable, as stated in the new Terms and Conditions. Match. Existing Fo'r poles being ordered to match existing or replace poles the original order -number must be referenced on -the new order along with "MAEX"in ordering nomenclature. This will ensure consistency in color, shape and component location. ~ ,~ L/THDN/A L/GH17NG@ Technical Information EPA (ft2) with 1.3 gust Nom. Pole Wall Bolt Bolt Ap p rox. Catalog mount. Shaft Size Thick. 80 Max. 90 Max. 100 Max. Circle Size ship wt. Number ht (ft.) (in. x in. x ft) (in.) Gauge mph wt. mph wt. mph wt. (in.) (in. x in. x in.) (Ibs.) SSS 10 4C 10 4.0 x 10.0 0.125 11 30.6 765 23.8 595 18.9 473 8-9 3/4 x 18 x 3 75 SSS 12 4C 12 4.0 x 12.0 0.125 11 24.4 610 18.8 470 14.8 370 8-9 3/4 x 18 x 3 90 SSS 14 4C 14 4.0 x 14.0 0.125 11 19.9 498 15.1 378 11.7 293 8-9 3/4 x 18 x 3 100 SSS 16 4C 16 4.0 x 16.0 0.125 11 15.9 398 11.8 295 8.9 223 8-9 3/4 x 18 x 3 115 SSS 18 4C 18 4.0 x 18.0 0.125 11 12.6 315 9.2 230 6.7 168 8-9 3/4 x 18 x 3 125 SSS 20 4C 20 4.0 x 20.0 0.125 11 9.6 240 6.7 167 4.5 150 8-9 3/4 x 18 x 3 140 SSS 20 4G 20 4.0 x 20.0 0.188 16;5 415 12.25 310 9.3 240 8-9 3/4 x. 30 x 3, 198 Figure 2 An~cu;tyBrands Company Sheet#: Pole-Info PL-105 Rev. 10/02 Pole-lnfo.P65 ,~ L/THDN/A L/GH17NG@ ~ FEATURES & SPECIFICATIONS INTENDED USE - Use for parking lots, streets and surrounding areas. CONSTRUCTION - Heavy gauge die-formed aluminum housing is fabricated using robotic continuous seam-weld process for weather-tight integrity. Integral structural support plate for mounting arm and electrical components ensures rigidity and strength. Hinged aluminum door frame incorporates stainless steel hardware. Continuous silicone gasketing surrounds lens for weather-tight seal. Optional tool-less hardware is available to maximize installation and maintenance ease. Thermal shock resistant tempered glass lens. Choice of contoured drop lens or flat lens is available in standard product. FINISH - Standard finish is dark bronze corrosion resistant electrostatically applied powder paint. Optional linear embossed accent reveals are available. OPTICS - Vertical-lamp reflectors are 1-piece spun and formed anodized aluminum. Specialized distributions available for either drop lens or flat lens. Reflectors are independently designed to optimize light output for the lens type. Horizontal-lamp reflectors 'also available. Mogul-base porcelain socketwith copper alloy, nickel-plated screw shell and center contact. Vertically-oriented for types SYM, and ASY distributions. Horizontal position-oriented for types FA, R2, R3 & R4. UL listed 1500W- 600V, 4kV pulse rated. Reflectors are rotatable and interchangeable. ELECTRICAL SYSTEM - All electrical components are mounted to a heavy-gauge plate to maximize heat dissipation and ensure structural integrity for optimal component life. Constant wattage autotransformer ballasts are copper wound and 100% factory tested. Super CWA Pulse-Start ballasts are required for 320, 350, 450 and 750 watt (must order SCWA option). INSTALLATION- Extruded aluminum arm with integral splice compartment Standard - arm is 9" in length. (12" arm is required fo rfixtu res mounted at900.) Arms are available for use with multiple poles, wall mounting and unique configurations. LISTING - UL Listed to US and Canadian safety standards (see Options). NOM certified (see options). UL listed for wet locations. ORDERING INFORMATION Notes Catalog Number SnS-KVF 400M ASYFL 208 RP09 LPI DBL Steak In Shake, Carmel, IN Type N Area Lighting KVF METAL HALIDE 250W, 320W, 350W, 400W, 450W, 750W, 1000W 20' to 40' Mounting Specifications EP A: 2.8 ft2 (.25m) (in cludes arm) Square: 21.5 (54.6) Depth: 17 (43.2) Arm length: 9 (22.8) Weight 53 Ibs (24 kg) All dimensions are inches {centimeters} unless otherwise specified. T o 1 ~A +- -I S Mountina Option Drillina Temolate -- - Representative of the embossed accents (EA) option. SPxx,RPxx,DA12P WBxx,DA 12WB \NWxx ASYFL RP09 Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank. Example: KVF 1000M SYMDL 120 SP09 SF DNA LPI KVF400M 208 I Vol~age I 120 2082 2402 277 347 4802 TB3 Mounting4 SP09 Square pole (9" arm)5 RP09 Round pole (9" arm)5 SP12 Square pole (12" arm) RP12 Round pole (12" arm) WW09 Wood po'le or wall (9" arm) WW12 Wood pole or wall (12" arm) WB09 Wall bracket (9" arm) WB12 Wall bracket (12" arm) KMA Mast Arm (external fitter) DA12P Degree Arm (pole) DA12WB Degree Arm (wall) Seri es KVF 250M KVF 320M KVF 350M KVF400M KVF 450M KVF 750M KVF 1000M' Vertical SYMDL Distribution Lamp Distributions: VFADL Symmetric square, drop lens Asymmetric, drop lens Symmetric square, flat lens Asymmetric, flat lens ASYDL Vertical forward throw automotive, ~rop lens Vertical Forward throw automotive, flat lens Horizontal Lamp Distributions: (not available with 450W or 750W) R2DL Type II Roadway, drop lens R2FL Type II Roadway, flat lens R3DL Type III Asymmetric, drop lens R3FL Type III Asymmetric, flat lens VFAFL SYMFl ASYFL NOTES: 1 Must use reduced jacket lamp. 2 Consult factory for availability in Canada. 3 Optional multi-tap ballast (120, 208, 240, 277V). (120, 277, 347V in Canada). 4 For arm mounting, refer to technical data section in the Outdoor binder for drilling template. S SP12 or RP12 must be used when two or more luminaires are oriented on a 900 drilling pattern. 6 Additional architectural colors available; please see Architectural Colors Brochure on www.lithonia.com. 7 May be ordered as. accessory. 8 Order as separate line item. Important with this accessory, an RP12 mounting arm must be ordered on the fixture. 9 For specific ordering information, consult factory. Outdoor LPIDBL Options SCWA Super CWA Pulse Start Ballast (750W & 1000W available in vertical lamp distributions only) NOM NOM Certified (consult factory) Shipped Installed In Fixture Tool-less Access Lamp included as standard Less Lamp Single fuse (120, 277, 347V; not available with " TB) OF Double fuse (208, 240, 480V; not available with TB) NEMAtwist-lock receptacle only (photocontrol not included) Quartz restrike system (250W max, lamp not included) GRS time delay (250W max, lamp not included) KiloWatch 120V control relay9 KiloWatch 277V control'relay9 Enhanced corrosion resistance External houseside shield (matches fixture finish, included in the carton) TLS LPI L/LP SF PER ORS- ORSTD KW1 KW4 ,CR EHS EHSB External houseside shield black (painted black to maximize light control, included in the carton) CSA Listed and labeled to comply with Canadian Standards Architectural Features EA Embossed Accents Architectural Colors (powder finish)6 Standard Colors DDB DVVH DBL Dark bronze (standard) White Black Classic Colors Medium bronze Natural aluminum Sandstone Charcoal gray Tennis green Bright red Steel blue [WI3 DNA DSS DGC om .DBR DSB PE1 PE3, PE4 PE7 Shipped SeparatelV7 NEMA twist-lock PE (120, 208, 240V) SC Shorting cap NEMA twist-lock PE (347V) KVFVG Vandal guard NEMA twist-lock PE (480V) KVFEHS_ External Houseside NEMA twist-lock PE (277V) shield (specify color) Accessories: Tenon Mounting SlipfitterE Number of fixtures Tenon 0.0. 0 ne 2-3/8" (6) T20-19U 2-7/8" (7.3) T25-190 4" (10.2) T30-19U Two@1800 Two@90o Three@120oThree@90o Four@90o T2U-280 T2U-290 T20-320 T20-390 T20-490 T25-280 T25-290 T25-320 T25-390 T25-490 TJO-280 T30-290 ' T30-320 T30-390 T30-490 Sheet #: KVF-M AL-420 KVF Arm-Mounted Area Liqhtinq Metal Halide Coefficient of Utilization _ Initial Footcandles _ KVF 1000M SYMDL Test No. LTL9410 COEFFICIENT OF UTILIZATION .0 .1 .2 .3 .4 .5 -~ :~ \ '. y~ ) 5~ ' "J 1 2.5_/~~ I ~ 1 ---..---' / .5 ~~./ ) .25 _ ___..... ~ ~ .62 1 ~ ~ W :c o ~ 'i= :z 1 5 ~ u- n 2 U) ..... z => 3 ~ 0.1____--' w '-' :z 4 ~ Cf) Ci o 1 2 3 4 5 6 1 OOOW Metal Halid.e lamp, 110000 rated lumens. Footcandle values based on 35' mouriting height, Distribution, SYMDL. .KVF 1 DOOM ASYDL EHS COEFFICIENT OF UTILIZATION Test No. LTL9417 .0 .1 .2 .3 .4 .5 .62 I r-- -z ,-",~ ,~ "J'" ~~ , ~:J , \ \ 2.5 ___V) V .~:::y/)( / .25 _L--" /" ~ \ 1 ~ ~ i:U ::c: o ~ f= :z 1 5 ~ 'u- n 2 U') to- Z => 3 ~ 0.1 ____~ UJ '-' :z 4 ~ U') is o 1 2 3 456 1000W Metal Halide lamp, 110000 rated lumens. Footcandle values based on 351 mounting height, Distribution, ASYDL EHS. NOTES: ,. Photometric data for other distributions can be accessed from the Lithonia Lighting website. (www.Lith(~>nia.com) 2. For electrical characteristics, consult technical dat~ tab. 3. Tested to current IES and NEMA standards under stabilized laboratory conditions. Various operating factors can cause differences between laboratory and actual field measurements. Dimensions and specifications are based on the most current available data and are subject to change. KVF 1 DOOM SYMFL Test No. LTL9418 KVF 1 DOOM ASYDL' Test No. LTL9420 COEFFICIENT OF UTILIZATION .0 .1 .2 .3 .4 ,Y' , -----, ./ ~ , /~ I ,,~ / '" 2.5 ----' ~ 'X. J I .~ ==:...- ~ I .25 _ J 0.1-- _--/ , o 1 2 3 4 5 6 1000W Metal Halide lamp, 110000 rated lumens. Footcandle values based on 351 mounting height, Distribution, SYMFL. .5 .62 COEFFICIENT OF UTILIZATION .0 .1 .2 .3 .4 .5 J:~0~ ~ \\\' /'~ 1 "Ul 2.5--V~"') J 1 _____~ / " .5 -~ ~~ J .25 _I--' /r O. 1 --- --""'" o 1 2 3 4 5 6 1000WMetal Halide lamp, 110000 rated lumens. Footcandle values based on 351 mounting height, Distribution, ASYDL. .62 1 ~ c.!J W :c o ~ i= z 1 5 ~ u.... o 2 CJ") I- Z :::::l 3 ~ w o z 4 ~ CJ") Ci ,KVF 1 OOOM ASYFL EHS COEFFICIENT OF UTILIZATION Test No. LTL9397 .0 .1 .2 .3 .4 .5 .62 L .J-..=:.--:::~ ~ ;:::::: \\ ) ~J \\\ \ 2.5-' >'J J ) 1 -~n V .5_ ~ .25 l./1 0.1 ---- KVF1 OOOM ASYFL Test No. LTL9395 COEFFICIENT OF UTILIZATION .0 .1 .2 .3 .4 :::f~r\\ \ /r\, .~') 5", I ' , ~ J J 2.5 ---",'/ " ~J ) /X J I 1 -/'- AI .5 - /~ \ .25 ~ 0.1 ~ o 1 2 3 4 5 6 1 OOOW Metal Halide lamp, 11 0000 rated lumens. Footcandle values based on 351 mounting height, Distribution, ASYFL. ~ ,~ LITHDNIA L/GHTING@ An <!5JtcuityBrands Company Sheet #: KVF-M @2001 Acuity Lighting Group, Inc., Rev. 3/04 KVF-M.p65 1 ~ C!) W :I: o ~ f=: z 1 5 ~ u.. o 2 en I- Z ~ 3 ~ w (.,) z 4 ;:s en Ci .5 .62 1 ~ C!) W ::c o ~ f=: z 1 5 :i: u.... o 2 en I- Z ~ 3 ~ w c...:> z 4 ~ en Ci I o 1 2 3 4 5 6 1 OOOW Metal Halide lamp, 11 0000 rated lumens. Footcandle values based on 351 mounting height, Distribution, ASYFL EHS. Mounting Height Co~rection Factor (Multiply the fc level by the correction factor) '5 ft.= 5.4 30 ft.= 1.36 38 ft.= 0.85 40 ft.= 0.77 Existing Mounting Height2 =' Correction Factor New Mounting Height2 1 5: C!J W :c o C!J z ~ z 1 5 :2: u- o 2 CI) I- Z => 3 ~ UJ u :z 4 ~ CI) C5 Lithonia Lighting Acuity Lighting Group, Inc. Outdoor Lighting One Lithonia Way, Conyers, GA 30012 Phone: 770-922-9000, Fax: 770-918-1209 In Canada: 160 avenue Labrosse, Point-Claire, p.n., H9R lAl www.lithonia.com ' ,~ LfT~DJVLA LfG~77JVG ~ FEATURES & SPECIFICATIONS CONSTRUCTION One-piece extruded 6063 aluminum alloy with a T6 temper. Circum- ferential brushed finish. The round straight tube is uniform in cross- section down the length of the shaft. Cast from A356 aluminum alloy and heat-treated to a T6 temper. The base slipfits the shaft, and they are joined together'by continuous circumferential welds at both the top and the bottom of the anchor base to provide maximum strength at the area of critical stress. Reinforced' hand hole having nominal dimensions of 2-3/8" x 4-1/2" for a 4" shaft and 3" x 5" for a 4-1/2", 5" or 6" shaft is located 18" above the base. Cover and attachment hardware provided. Top cap provided with all drill-mount poles. All hardware is made of 'Stainless steel. A356 nut covers are included with each anchor base unless other- - wise specified. FINISH - Brushed aluminum is standard. Optional polyester powder paint and anodizeq "finishes available. GROUNDING Aground lug located immediately inside the handhole is tapped for 3/8" - 16 UNC ground bolt (not supplied). ANCHOR BOLTS Top portion of anchor bolt is galvanized per ASTM A-153. Made of steel rod having a minimum yield strength of 55,000 psi. ORDERING INFORMATION. Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank. RSA I Sha~ type I RSA 18 I Nominal shaft length 8 - 30 feet (See bpck page.) 4-5G (See next page.) HANDHOLE ORIENTATION C o B A Handhole NOTES: , When ordering tenon mounting and drill mounting for the same . pole, follow this example: DM28!T20. The combination requires an exta handhole. 2 3-1/2" and 4" tenons available on 5" and 6" shafts only. 3 The drilling 'template to be used for a particular luminaire depends on the luminaire that is used. Refer to the Technical Data Section of the Outdoor Binder for Drilling Templates. 4 Specify location and orientation when ordering an option is required. For 1st "x": Specify the height in feet above base of pole. Example: 5ft = 5 and 20ft = 20 For 2nd "XII: Specify orientation from handhole (A,B,C,D) Refer to tIle Handhole Orientation diagram on this page. 5 Horizontal arm is 18" x 2-3/8" 0.0. tenon standard. S Combination of tenon-top and drill mount requires extra handhole. 7 Additional colors available; see Architectural Colors brochure, form no. 794.3. Outdoor Catalog Number SnS RSA 18 4-5G DM19 FBC VD DBL Notes Steak In Shake, Carmel, IN Type N-Pole Anchor Base Poles RSA ROUND STRAIGHT ALUMINUM Example: RSA 16 4-5C DM19 BA DM19 FBe VD DBL I I I I Mounting' Options (Must specify finish) Tenon Mounting Shipped Installed Standard Finish P1 Open top LlAB LessAnchorBolts SA Brushed aluminum 120 2-3/8" 0.0. (2" NPS) FBC 'Full Base Cover Architectural Colors 125 2-7/8" 0.0. (2-1/2" NPS) VD Vibration Damper (powder finish)7 T302 3-1/2" 0.0. (3" NPS) TP Tamper Proof Standard Colors - HXX4.5 HorizontalArm T352 4" 0.0. (3-1/2" NPS) Bracket (1 fixture) DDS Dark bronze Drill Mounting3 FDLxx4 Festoon OutJetless DWH White DM19 1 at 900 electrical DBL Black FGLxx4 Festoon GFI Outlet Classic Colors DM28 2 at 1800 less electrical OMB Medium bronze DM28PL 2 at 1800 with one side 12CPxx4 1/2" Threaded DNA Natural plugged Coupling aluminum DM29 2 at 900 34CPxx4 3/4"Threaded DSS Sandstone DM32 3 at 1200 Coupling DGC Charcoal gray OM39 3 at 900 1CPxx4 1M Threaded DTG Tennis green Coupling DM49 4 at 900 12 NPxx4 1/2" Threaded OBR Bright red Aeris Drill Mounting3 Nipple DSB Steel blue OM19AS 1 at 900 34NPxx4 3/4" Threaded Class 1 Architectural Nipple Anodize DM28AS 2at1800 1 NPxx4 1" Threaded Nipple ABL Black DM29AS 2 at900 H Hxx4.6 Extra Handhole ADS Dark bronze DM32AS 3at1200 ANA Natural DM39AS 3 at900 OM49AS 4at900 IMPORTANT INSTALLATION NOTES: · Donat erect poles without having fixtures installed. ~ Factory-supplied templates must be used when setting anchor bolts. Lithonia will not accept claim for incorrect anchorage placement due to failure to use factory template. · If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. · Lithoniais not responsible for the foundation design. , · InstallatIon requires grout to be packed under base to ensure full contact with foundation. Sheet#: Pole-RSA PL - 200 , , RSA Round Straight Aluminum Poles TECHNICAL INFORMATION EPA (ft2) with 1.3 gust Nominal Wan Approximate Catalog shaft Pole Shaft Thickness 80 90 100 Max. Bolt Circle Bolt Size ship weight Number length (feet) Size (in x ft) (inches) mph mph mph weight (inches) (in. x in. x in.) (pounds) RSA 8 4C 8 4.0 x 8.0 0.125 11.2 8.6 6.8 125 6-1/2-8-1/4 3/4 x 18 x 3 22 RSA 8 4-5C 8 4.5 x 8.0 0.125 14.6 11.3 9.1 175 7 - 1 /8-8-3/8 3/4 x 18 x 3 30 RSA 8 '4-5G 8 4.5 x 8.0 0.188 21.8 17.0 13.7 225 7 -1/8-8-3/8 3/4 x 18 x 3 38 RSA 10 4C 10 4.0 x 10.0 0.125 8.2 6.1 4.7 100 6-1/2-8-1/4 3/4 x 18 x 3 26 RSA 10 4-5C 10 4.5 x 10.0 0.125 10.6 8.1 6.5 133 7-1/8-8-3/8 3/4 x 18 x 3 34 RSA 10 4-5G 10 4.5 x 10.0 0.188 16.3 12.6 10.1 175 7 -1/8-8-3/8 3/4 x 18 x 3 43 RSA 10 5C 10 5.0 x 10.0 0.125 13.6 10.6 8.5 150 7-1/2-9-1/2 3/4 x 18 x 3 36 RSA 12 4C 12 4.0 x 12.0 0.125 6.0 4.3 3.2 110 6-1/2-8-1/4 3/4 x 18 x 3 30 . RSA.124-5C 12 4.5 x 12.0 0.125 8.1 6.0 4.8 80 7 - 1/8-8-3/8 3/4 x 18 x 3 38 RSA 12 4-56 12 4.5 x 12.0 0.188 12.7 9.7 7.7 185 7 -1/8-8-3/8 3/4 x 18 x 3 50 RSA 12 5C 12 5.0 x 12.0 0.125 10.3 8.0 6.3 150 7-1/2-9-1/2 3/4 x 18 x 3 36 RSA 12 5E 12 5.0 x 12.0 0.156 13.2 10.3 8.2 200 7-1/2-9-1/2 3/4 x 18 x 3 44 RSA 12 5G 12 5.0 x 12.0 0.188 16.2 12.6 10.1 225 7-1/2-9-1/2 3/4 x 18 x 3 53 RSA 14 4C 14 4.0 x 14.0 0.125 4.1 2.8 1.9 75 6-1/2-8-1/4 3/4x18x3 35 RSA 14 4-5C 14 4.5 x 14.0 0.125 5.8 4.2 3.3 60 7 -1/8-8-3/8 3/4 x 18 x 3 42 RSA 14 4-56 14 4.5 x 14.0 0.188 9.7 7.3 5.8 190 7 -1/8-8-3/8 3/4 x 18 x 3 56 RSA 14 5C 14 5.0 x 14.0 0.125 7.8 6.0 4.7 100 7-1/2-9-1/2 3/4 x 18 x 3 39 RSA 14 5E 14 5.0 x 14.0 0.156 10.3 8.0 6.3 125 7-1/2-9-1/2 3/4 x 18 x 3 47 RSA 14 5G 14 5.0 x 14.0 0.188 12.8 9.9 7.9 150 7-1/2-9-1/2 3/4 x 18 x 3 56 RSA 16 4C 16 4.0 x 16.0 0.125 2.8 1.6 1.0 150 6-1/2-8-1/2 314 x 18 x 3 38 RSA 16 4-5C 16 4.5 x 16.0 0.125 4.2 2.8 2.1 50 7 -1/8-8-3/8 3/4 x 18 x 3 46 RSA 16 4-5G 16 4.5x 16.0 0.188 7.5 5.5 4.3 155 7 -1 /8-8-3/8 3/4 x 18 x 3 62 RSA 16 5C 16 5.0 x 16.0 0.125 5.9 4.4 3.4 175 7 -1/2-9-1/2 3/4 x 18 x 3 46 RSA 16 5E 16 5.0 x 16.0 0.156 8.0 6.1 4.8 190 7 -1/2-9-112 3/4 x 18 x 3 53 RSA 16 5G 16 5.0 x 16.0 0.188 10.1 7.8 6.1 200 -7 -1/2-9-1/2 3/4 x 18 x 3 ' 60 RSA 16 6E 16 6.0 x 16.0 0.156 13.6 10.6 8.4 225 8-3/4-10-1/4 3/4 x 30 x 3 53 RSA 16 6G 16 6.0 x 16.0 0.188 16.8 13.0 10.4 245 8-3/4-10-1/4 3/4 x 30 x 3 78 RSA 18 4-5G 18 4.5 x 18.0 0.188 5.7 4.0 3.1 123 7 -1/8-8-3/8 . 3/4 x 18 x 3 68 RSA 18 5C 18 5.0 x 18.0 0.125 4.3 3.1 2.4 150 7 -1/2-9-1/2 3/4 x 18x3 48 RSA 18 5E 18 5.0 x 18.0 0.156 6.1 4.6 3.5 175 7-1/2-9-1/2 3/4 x 18 x 3 58. RSA 18 5G 18 5.0 x 18.0 0.188 8.0 6.8 4.7 225 7-1/2-9-1/2 3/4 x 18 x 3 68 RSA 18 6G 18 6.0 x 18.0 0.188 13.9 10.7 8.5 225 8-3/4-10-1/4 3/4 x 30 x 3 86 RSA 20 4-5G 20 4.5 x 20.0 0.188 4.3 2.9' 2.1 95 7 - 1 /8-8-3/8 3/4 x 18 x 3 74 RSA 20 5C 20 5.0 x 20.0 0.125 JO 2.1 1.5 150 7-1/2-9-1/2 3/4 x 18 x 3 54 RSA 20 5E 20 5.0 x 20.0 0.156 4.7 3.4 2.6 150 7-1/2-9-1/2 3/4 x 18 x 3 68 RSA 20 5G 20 5.0 x 20.0 0.188 6.4 4.8 3.6 150 7 -1/2-9-1/2 3/4 x 18 x 3 82 RSA 20 6E 20 6.0 x 20.0 0.156 9.3 7.1 5.5 175 8-3/4-10-1/4 3/4 x 30 x 3 95 RSA 20 6G 20 6.0 x 20.0 0.188 11.8 9.1 7.1 200 8-3/4-10-1/4 3/4 x 30x 3 110 RSA 25 4-5G 25 4.5 x 25.0 0.188 1.3 -- -- 100 7 -1/8-8-3/8 3/4 x 18 x 3 89 RSA 25 6E 25 6.0 x 25:0 0.156 5.2 3.8 2.8 150 8-3/4-10-1/4 3/4 x30 x3 108 RSA 25 6G 25 6.0 x 25.0 0.188 7.1 5.3 4.0 150 8-3/4-10-114 3/4 x 30 x 3 128 RSA 30 6G 30 6.0 x 30.0 0.188 3.5 2.4 1.6 ' 200 8-3/4-10-1/4 3/4 x 30 x 3 146 BASEDET AIL I Shaft Base Size Bolt Circle A Bolt Base Projection Square B C Anchor Warehouse Template Bolt Anchor Bolt Number Descripti~n Description B 4" 6-1/2"-8-1/4" 3-1/4" 8-3/4" ABRSA-4 AB18-0 PJ50057 4-1/2" 7-1/8"-8-3/8" 3-1/4" 8-1/2'1 ABRSA-4-5 A818-0 PJ50040 5" 7';112'1-9-1/2" 3-1/4" 9-1/4'1 ABRSA-5, A818-0 PJ50058 6" 8-3/4"-10-1/41' 3-1/2" 10-1/4" ABRSA-6 AB30-0 PJ50059 IMPORTANT: · These specifications are intended for general purposes only. Lithonia reserves the right to change material or design, without prior notice, in a continuing effort to upgrade its products. ,~ LfTHDN~ LIGHTING' lithonia lighting Acuity lighting Group. Inc. Outdoor lighting One Lithonia Way, Conyers, GA30012-3957 Phone: 770-922-9000 Fax: 770..918-1209 In Canada: 1100 50th Ave., Lachine, Quebec H8T 2V3 www.lithonia.com ~ An~cuityBrands Company Sheet #: Pole-RSA @1994 Lithonia Lighting. Rev. 6/02 Pole-RSA.P65