Loading...
HomeMy WebLinkAboutA1.2 REFLECTED CEILING_ELEC-DATA PLANS.pdfProject Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A 4 6 0 3 2 By: Architect: Architecture / Project Management: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Drawn By Checked ByPrint Date Revisions: 76 0 3 R D A V E N U E S . W . PE D C O R S Q U A R E B U I L D I N G 2 KE L L E R MA C A L U S O , L L C N A1.2 REFLECTED CEILING/ELEC- DATA PLANS PEDCOR DESIGN GROUP, LLC 12/23/13 CONSTRUCTION DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICE AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALLINFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALLINFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, ANDPEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, ORPORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED,MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THESPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC.© COPYRIGHT 2012, JAMES R. STUTZMAN, AIA, CARMEL. 12/23/13 STATE RELEASE SET MC AJR KEY PLAN SCALE: N.T.S. SECOND FLOOR CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. RELOCATE OR ADD LIFE SAFETY ITEMS AS REQUIRED FOR NEW WALL LAYOUT. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. GENERAL CEILING NOTES: EXISTING EMERGENCY LIGHT FIXTURE W/BATTERY PACK TO REMAIN. 5. 6. 4. 1. CP6 3. RELOCATE OR ADD FIRE SPRINKLERS AS REQUIRED FOR NEW WALL LAYOUT. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED. CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT CONDITION AS TO NOT SHOW LINE OF DEMOLITION. NEW OR RELOCATED DOWNLIGHT FIXTURE TO MATCH EXISTING. N INDICATION DUAL-LITE TO MATCH EXISTING. NEW OR RELOCATED CEILING MOUNTED EXIT LIGHT W/ DIRECTION DUAL-LITE TO REMAIN. EXISTING CEILING MOUNTED EXIT LIGHT W/ DIRECTION INDICATION N D 3 2.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW ONLY. ALL WALLS GO TO 6" ABOVE FINISHED CEILING UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. CEILING HEIGHT IS 10'-0" A.F.F. UNLESS NOTED OTHERWISE. CEILING PLAN NOTES: CP1 CP2 INSTALL NEW TILE AND GRID AS SHOWN. REUSE DEMO'D TILE AS MUCH AS POSSIBLE. PROVIDE NEW SWITCH TO CONTROL LIGHTING. CP3 CP4 LIGHT FIXTURES TO BE CONTROLLED BY AN OCCUPANCY SENSOR. HVAC CONTRACTOR TO RECONFIGURE HVAC DISTRIBUTION FROM THE EXISTING HEAT PUMP UNITS AS NEEDED FOR THE NEW LAYOUT. CONSIDER DEDICATING BOTH EXISTING UNITS FOR SUITE 210 AND PROVIDING A NEW SYSTEM FOR THE ADJACENT SUITE. THREE-WAY SWITCH. DIMMER SWITCH. TWO WAY SWITCH. DENOTES NEW SWITCH LOCATION. EXISTING 2 X 4 LAY-IN GRID SUSPENSION SYSTEM. EXISTING. REFLECTED CEILING LEGEND: NEW OR RELOCATED 2' X 4' FLUORESCENT FIXTURE TO MATCH EXISTING 2' X 4' FLUORESCENT FIXTURE TO REMAIN. CP5 REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING. G.C. TO VERIFY EXISTING GRID LAYOUT AND CONDITION. RE-USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED FIXTURES TO BE COORDINATED WITH OWNER. ALL EXISTING AND REUSED FIXTURES TO BE CLEANED AND RELAMPED UPON COMPLETION OF CONSTRUCTION. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. 10. 9. 8. 7. LOCATE NEW AND RELOCATED SMOKE DETECTORS DUE TO NEW WALL AND/OR LIGHT FIXTURE LAYOUT. INFORM DESIGNER AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. HALLWAY LIGHTS TO BE TIED INTO THE EXISTING HALLWAY LIGHT CIRCUIT.CP7 N NEW OR RELOCATED EMERGENCY LIGHT FIXTURE W/BATTERY PACK TO MATCH EXISTING.N NEW OR RELOCATED LAY-IN GRID SUSPENSION SYSTEM TO MATCH EXISTING. N N N N N N N N N N N N N N N N N N N N N N N N N N CP1CP5 CP7CP6 N CP2 CP1 CP1 N N CP2 CP3 CP4 CP4 CP1 CP5 CP3 CP5 CP6 CP3 CP3CP3CP3 N N N N N N N N N N D CP1CP4 CP6CP5 CP4 CP5 CP2 N CP2 N CP2 N CP3 CP4 CP5 CP3 CP4 CP5 N CP2 CP3 CP3 N N LOBBY 201 OFFICE 2 206 OFFICE 1 205 OPEN OFFICE 213 IT ROOM 215 CONFERENCE ROOM 204 COFFEE BAR OFFICE 3 207 OFFICE 5 209 OFFICE 4 208 FILE ROOM 214 OFFICE 6 210 PRINTER/ COPIER 72"72" 44" 44" FEC HALL 200 HALL 202 CL. 203 FEC EP1 N N N N N N N N N N N N EP1 N EP2PARALEGAL OFFICE 216 EP3 EP4 EP5 N N +44" +44" N N +44" N EP6 N N N +60" +60" N GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY PEDCOR IT. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF TO CENTER OF COVER PLATE UNLESS NOTED OTHERWISE. 7. 8. 6. 5. 4. 3. PROVIDE FLOOR MOUNTED POWER/COMMUNICATIONS AS FLUSH MOUNTED. ELECTRICAL/DATA PLAN NOTES: FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY.9. 10.PEDCOR IT TO PROVIDE PHONE AND INTERNET SERVICE. CONSIDER, IF APPROPRIATE, LOCATING THE THERMOSTATS AS SHOWN OR AS NEEDED FOR PROPER FUNCTION OF THE HVAC SYSTEM. EP1 PROVIDE ELECTRICAL AND DATA FOR WALL MOUNTED TV MONITOR.EP2 ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE. DUPLEX WALL OUTLET. DEDICATED CIRCUIT OUTLET.D CABLE TV OUTLET. FLOOR MOUNTED FLUSH MOUNT TELEPHONE OUTLET. ELECTRICAL/DATA LEGEND: GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. PHONE/DATA WALL OUTLET (BOX AND PULL STRING). +44" N HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. DENOTES NEW OUTLET LOCATION. FLOOR MOUNTED FLUSH MOUNT DUPLEX OUTLET. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. 1. 2.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW ONLY. PROVIDE FLOOR MOUNT, FLUSH POWER AND DATA FOR WORK STATIONS.EP3 COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. EP4 REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. EP5 PROVIDE ELECTRICAL FOR KEY FOB ACCESS AT FRONT DOOR.EP6 SCALE: 1/8" = 1'-0" 1 REFLECTED CEILING PLAN A1.2 SCALE: 1/8" = 1'-0" 2 ELECTRICAL/DATA PLAN A1.2