REVIEW STOP: BLDG - BUILDING INSPECTOR REVIEW
REV NO: 1 STATUS: C DATE: 12/30/05 CONT ID:
REVIEW SENT BY: aslhrine~ DATE: 12/30/05 TIME: 15:51 TIME SPENT: C.00
REV RECEIVB BY: as_hrine DATE: 12/22/05 TIME: C8:58 SENT TO:
REVIE 2005-12-30
16:00:20 Conditmons of Permmn:
Smoke detc r mus~ be uD traded to
throughout enEmre house
be s~rveved and Dmnned ov
Surveyor ermor to footino mnsueczmon.
Notice: No etec~rlc was indicated on
plan at time of review for de~ached
ENCOMPASS - Pentamation permit.4ge (permm~5.4gl) RUN DATE:!2/38/05
R313.2 Required smoke alarm locations. At least one smoke alarm shall be installed in each of the following locations:
I, In the living area remote from the kitchen and cooking appliances. Smoke alarms located within 20 feet horizontally of a
cooking appliance must incorporate a temPorary silencin~ f~ature or be photoelectric type,
2, In each room designed for sleeping.
3, On the ceiling of the upper level near the top or above each stairway, other than a basement staLrway, in any multistory
dwelling. The alarm shall be located so that smoke rising in the stairway cannot be prevented from reacb~ng the alarm by an
intervening door or obstruction.
4, On the basement ceiling near the stairway.
R313.2.1 ALterations and additions When ~ntenor alterations or additions requiring a permit occur.
OR when one or more sleeping rooms are added or created in existing dwellings, the individual dwelling
-anit shall be provided with smoke alarms.
The Alarms as required for new dwellings. The smoke alarms
R313.5.2 Interconnection. When more than one smoke alarm is required to be installed within an
indi'~idual dwelling unit, the alarm deVices shall be intercOnnected in such a manner that the actuation of
one alarm will activate all of the alarms in the individual unit.
EXCEPTIONS:
be required to meet the requirements where the alterations do not result in the removal
[ess, there is an attic, crawlspace, or basement available that
R313.
I.
2.
R313.4 Mounting requirements. Smoke alarms their listing installation insmlcnons and the reqmremen/s of th~s
R313.4,1 Flat Ceilings. In rooms with fiat peaked sloping or single slope ceilings with a slope of less than 1.5/12. smoke alarms
shall be mounted either:
1. On the ceiling at least 4 inches from each wall or
2. On a wall wi(h the top of the alarmnot less than 4 inches below the ~eiling and not farther from the ceiling than 12 inches or
the distance fi'om the ceiling specified in the smoke alarm manufacture s listing and installation instructions, whichever is less.
R313.4.2 Peaked Sloping Ceilings. In rooms with peaked sloping ceilings with a slope of 1.5/12 or gl'eater, smoke alarms shall
be
1. Mounted on the ceiling or wall within 3 feet measured horizontally from the peak of the ceiling;
At least 4 inches measured vertically, below the peak of the ce ling; and
kt least 4 inches from any projecting structural element.
R313.4.3 Single Slope Ceilings. In rooms with smgle slope ceilings with a slope of 1 5/12 or greater smoke alarms shal be
1. Mounted ~ the c~iling or ~atl within 3 feet measured horizontally, of the t~igh point of the ceiling and
2. Not closer than 4 inches from a ~all surfaces or any projecting structural element.
R31 notification appliances. SEE CODE
f . Each smoke alarm shall be powered from:
o the home as the primary power source mad a battery as a secondary power
the smoke tor use with a 10 year battery.
circuit.