HomeMy WebLinkAboutSEALED 1410484-12T.pdfDE
DANSCO ENGINEERING, LLC
P.O. Box 3400
Apollo Beach, FL 33572
Telephone (813) 645-0166
Facsimile (813) 645-9698
The truss drawing(s) listed below have been prepared by Stark Truss, Inc. under my
direct supervision based on the parameters provided by the truss designers.
Job: 1410484-12T
80 truss design(s)
33078-W1
3/28/14
Samuel A. Greenberg, P.E.
Indiana Reg. #19700485
Note: Gable end frames with stud lengths exceeding 4’ require permanent bracing. On structural
gables, where studs may be made from two or more boards as they cross diagonals, the 4’ length
is the distance from the top chord to bottom chord.
The seal on these drawings indicate acceptance of professional engineering
responsibility solely for the truss components shown. The suitability and use of this
component for any particular building is the responsibility of the building designer, per
ANSI/TPI 1-2002 Chapter 2.
Warning !—Verify design parameters and read notes before use.
These designs are based only upon parameters shown, and are for individual building components to be installed and loaded vertically. Applicability of
design parameters and proper incorporation of component is responsibility of building designer – not truss designer or truss engineer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to ensure stability during construction is the responsibility of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication,
quality control, storage, delivery, erection and bracing, consult ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss
Construction and BCSI 1-03 Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses from Truss Plate
Institute, 583 D’Onofrio Drive, Madison, WI 53719
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J01
TrussType
Jack-ClosedGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:382014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-Nj0dmI1baGgLX2sHNDnpmIxb?HuC?Q8CXyH6aqzWRWJ
Scale=1:13.4
W1
T1
T2
T3
T4
W7
B1
W2 W3 W4
W5
W6
1
2
3
4
5 6
11 10 9 8 7
6x16MT18H
4x4 4x4 1.5x3
1.5x3 3x4 1.5x3 1.5x3
0-3-6
0-3-6
0-11-1
0-7-11
2-4-0
1-4-15
3-1-15
0-9-15
3-8-14
0-6-15
-1-2-8
1-2-8
0-11-1
0-11-1
2-4-0
1-4-15
3-1-15
0-9-15
3-8-14
0-6-15
0-10
-0
1-1-3
1-8-4
2-1-3 1-9-11
0-3-8
2-1-3
3.5012
5.0012
6.0012
PlateOffsets(X,Y): [4:0-2-0,0-0-12], [5:0-2-0,0-1-12], [11:0-5-0,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.28
0.05
0.04
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.00
(loc)
10
9
7
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
MT18H
Weight: 19 lb FT= 10%
GRIP
197/144
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-8-14 oc purlins,
except end verticals, and 2-0-0 oc purlins: 5-6.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)11=143/0-4-0(min. 0-1-8), 7=71/0-1-8(min. 0-1-8)
Max Horz11=59(LC 8)
Max Uplift11=-100(LC 8), 7=-55(LC 8)
MaxGrav11=204(LC 12), 7=77(LC 20)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft exposed ; end verticalleft exposed; porchleft exposed; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)Provide adequate drainage to preventwater ponding.
6)All plates areMT20 plates unless otherwiseindicated.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Bearing at joint(s) 7 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
9)Providemechanicalconnection(by others) of truss to bearing plate at joint(s) 7.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 7 except(jt=lb)
11=100.
11)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
12)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
13)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
14)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-60
Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J01
TrussType
Jack-ClosedGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:382014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-Nj0dmI1baGgLX2sHNDnpmIxb?HuC?Q8CXyH6aqzWRWJ
LOADCASE(S)Standard
Trapezoidal Loads(plf)
Vert: 2=-2(F=29,B=29)-to-3=-14(F=23,B=23), 3=-14(F=23,B=23)-to-4=-36(F=12,B=12), 4=-36(F=12,B=12)-to-5=-49(F=5,B=5), 5=-49(F=5,B=5)-to-6=-56(F=2,
B=2), 11=0(F=10,B=10)-to-7=-19(F=1,B=1)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J02
TrussType
Jack-Closed
Qty
11
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:392014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-rva?_e2DLaoC9CRTxxI2IWTnJhEtksDMmc1f7GzWRWI
Scale=1:14.9
W1T1
T2
T3
W7
B1
W2 W3 W4
W5 W6
1
2
3
4
5
9 8 7 6
3x4
1.5x3
4x8
1.5x3
1.5x3 3x4
4x6
3x4
0-3-6
0-3-6
0-11-1
0-7-11
2-4-0
1-4-15
3-8-14
1-4-14
-1-2-8
1-2-8
0-11-1
0-11-1
2-4-0
1-4-15
3-8-14
1-4-14
0-10
-0
1-1-3
1-8-4
2-4-11
2-1-3
0-3-8
2-4-11
3.5012
5.0012
6.0012
PlateOffsets(X,Y): [3:0-3-4,0-2-0], [4:0-4-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.24
0.03
0.05
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.00
(loc)
8
8
6
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 19 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-8-14 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)9=235/0-4-0(min. 0-1-8), 6=122/0-1-8(min. 0-1-8)
Max Horz9=99(LC 10)
Max Uplift9=-117(LC 10), 6=-91(LC 10)
MaxGrav9=256(LC 2), 6=131(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-9=-292/205
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)-1-2-8 to 2-4-0,Interior(1) 2-4-0 to 3-7-2zone;cantileverleft exposed ; end verticalleft exposed; porchleft
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Bearing at joint(s) 6 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
7)Providemechanicalconnection(by others) of truss to bearing plate at joint(s) 6.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 6 except(jt=lb)
9=117.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J03
TrussType
Jack-OpenGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:392014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-rva?_e2DLaoC9CRTxxI2IWTl2hASkqvMmc1f7GzWRWI
Scale=1:14.6
W1
T1
T2
T3
W7
B1
W2
W3 W4
W5 W6
1
2
3
4
5
10 9 7 6
8
8x8
4x6
1.5x3
3x4 3x4
4x6
3x4
1-0-12
1-0-12
1-6-13
0-6-1
2-8-4
1-1-7
4-2-14
1-6-9
-1-3-13
1-3-13
1-0-12
1-0-12
2-8-4
1-7-8
4-2-14
1-6-9
0-10
-0
1-1-3
1-8-4
2-4-5 2-0-13
0-3-8
2-4-5
3.0412
4.3412
5.2112
PlateOffsets(X,Y): [3:0-4-12,0-2-0], [4:0-4-12,0-2-0], [10:0-2-12,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.32
0.31
0.13
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
-0.00
(loc)
7
7
6
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 21 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 4-2-14 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)8=294/0-8-1(min. 0-1-8), 6=-34/0-1-8(min. 0-1-8)
Max Horz8=70(LC 8)
Max Uplift8=-242(LC 6), 6=-155(LC 12)
MaxGrav8=404(LC 12), 6=51(LC 6)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-192/398
BOT CHORD 8-9=-416/227, 7-8=-416/175
WEBS 2-9=-316/178, 3-7=-108/255, 4-7=-299/146, 4-6=-131/303
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft exposed ; end verticalleft exposed; porchleft exposed; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Bearing at joint(s) 6 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
7)Providemechanicalconnection(by others) of truss to bearing plate at joint(s) 6.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
8=242, 6=155.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
11)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-60
Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J03
TrussType
Jack-OpenGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:392014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-rva?_e2DLaoC9CRTxxI2IWTl2hASkqvMmc1f7GzWRWI
LOADCASE(S)Standard
Trapezoidal Loads(plf)
Vert: 2=-2(F=29,B=29)-to-3=-17(F=22,B=22), 3=-17(F=22,B=22)-to-4=-42(F=9,B=9), 4=-42(F=9,B=9)-to-5=-64(F=-2,B=-2), 10=0(F=10,B=10)-to-6=-21(F=-1,
B=-1)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J04
TrussType
Jack-Closed
Qty
2
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:402014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-J68NB_3r6tw3nM0fVepHrj0ye5Z2TJgV?GmDfizWRWH
Scale=1:27.8
T1
T2
T3
T4
W4
B1
W1 W2
W3
B21
2
3
4
5
6
9 8 7
10
3x4
4x6
4x6
1.5x3
1.5x33x55x6
3x4
2-0-0
2-0-0
4-0-0
2-0-0
4-5-12
0-5-12
-1-0-0
1-0-0
0-6-0
0-6-0
2-0-0
1-6-0
4-0-0
2-0-0
4-5-12
0-5-12
0-6-7
0-10
-15
2-2-11
4-3-11
4-10
-6
5-5-5
9.0012
10.5012
12.5012
14.0012
PlateOffsets(X,Y): [2:0-1-2,0-1-8], [5:0-3-4,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.21
0.09
0.03
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.00
(loc)
8
8-9
7
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 29 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2 *Except*
B1: 2x6SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 4-5-12 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)7=153/Mechanical, 2=238/0-5-8(min. 0-1-8)
Max Horz2=218(LC 10)
Max Uplift7=-130(LC 10), 2=-26(LC 10)
MaxGrav7=165(LC 2), 2=270(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)-1-0-0 to 0-6-0,Interior(1) 0-6-0 to 4-4-0zone;cantileverleft exposed ; end verticalleft exposed;C-C formembers
and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2 except(jt=lb)
7=130.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J05
TrussType
JACK-CLOSED
Qty
1
Ply
2
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:402014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-J68NB_3r6tw3nM0fVepHrj0vL5UATB7V?GmDfizWRWH
Scale=1:27.8
T1
T2
T3
T4
W4
W1 W2
W3
B1
1
2
3
4
5
6
9 8 7
10
11
12
6x8
4x6
4x6
2x4
2x43x6
3x4
2-0-0
2-0-0
4-0-0
2-0-0
4-5-12
0-5-12
-1-0-0
1-0-0
0-6-0
0-6-0
2-0-0
1-6-0
4-0-0
2-0-0
4-5-12
0-5-12
0-6-7
0-10
-15
2-2-11
4-3-14
4-10
-6
5-5-5
9.0012
10.5012
12.5012
14.0012
PlateOffsets(X,Y): [3:0-3-5,0-2-12], [5:0-2-12,0-2-0], [9:0-4-0,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.42
0.41
0.52
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.03
0.00
(loc)
8-9
8-9
7
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 61 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x6SPF 2100F 1.8E
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 4-5-12 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)7=1246/Mechanical, 2=2572/0-5-8(min. 0-2-4)
Max Horz2=187(LC 7)
Max Uplift7=-368(LC 7), 2=-641(LC 8)
MaxGrav7=1697(LC 2), 2=3499(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-1973/347, 3-4=-2071/381, 5-6=-81/294, 6-7=-423/85
BOT CHORD 2-11=-332/1529, 9-11=-332/1529, 9-12=-297/1336, 8-12=-297/1336
WEBS 4-9=-428/2399, 4-8=-1783/392, 5-8=-153/463
NOTES
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-9-0 oc.
Bottomchordsconnected as follows: 2x6- 2 rowsstaggered at 0-2-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
4)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8) Refer to girder(s) for truss to trussconnections.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
7=368, 2=641.
10)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
11)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
12) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 2357 lb down and 414 lb up at
0-6-8, and 2404 lb down and 421 lb up at 2-6-8 on bottomchord.The design/selection of suchconnection device(s)is the
responsibility of others.
LOADCASE(S)Standard
Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J05
TrussType
JACK-CLOSED
Qty
1
Ply
2
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:402014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-J68NB_3r6tw3nM0fVepHrj0vL5UATB7V?GmDfizWRWH
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-60, 2-3=-20, 3-4=-60, 4-5=-60, 5-6=-60, 2-7=-20
Concentrated Loads(lb)
Vert: 11=-1716(B) 12=-1710(B)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J06
TrussType
Jack-OpenGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:402014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-J68NB_3r6tw3nM0fVepHrj0qk5WRTJBV?GmDfizWRWH
Scale=1:17.6
W1
T1
B1
1
2
5
6
3
4
3x4
3x4
3-3-11
3-3-0
-2-0-3
2-0-3
3-3-11
3-3-11
0-11
-12
2-10
-11
3-5-0
6.9512
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.71
0.26
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.01
-0.03
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 12 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-3-11 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)5=211/0-9-12(min. 0-1-8), 3=22/Mechanical, 4=2/Mechanical
Max Horz5=121(LC 8)
Max Uplift5=-130(LC 8), 3=-35(LC 12), 4=-15(LC 12)
MaxGrav5=346(LC 12), 3=64(LC 6), 4=40(LC 5)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-5=-305/131
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 3, 4 except(jt=lb)
5=130.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-60
Trapezoidal Loads(plf)
Vert: 2=-2(F=29,B=29)-to-3=-50(F=5,B=5), 5=0(F=10,B=10)-to-4=-17(F=2,B=2)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J07
TrussType
Jack-Open
Qty
20
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:412014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-nIilPK4TtB2wOWas2MKWNxZ6OVvtCmRfEwWmB9zWRWG
Scale=1:19.0
W1
T1
B1
1
2
5
3
4
2x4
3x5
1-9-0
1-9-0
-1-0-0
1-0-0
1-9-0
1-9-0
0-11
-12
3-0-4
3-7-14
0-7-2
2-5-2
3-0-4
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.27
0.12
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.01
(loc)
5
5
3
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 8 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 1-9-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)5=157/0-5-8(min. 0-1-8), 4=10/Mechanical, 3=29/Mechanical
Max Horz5=178(LC 10)
Max Uplift5=-1(LC 10), 4=-27(LC 10), 3=-67(LC 10)
MaxGrav5=207(LC 14), 4=28(LC 5), 3=32(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS
forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 4, 3.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J08
TrussType
Jack-OpenGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:412014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-nIilPK4TtB2wOWas2MKWNxZzVVqUCmRfEwWmB9zWRWG
Scale=1:29.9
W1
T1
B1
1
2
5
6
3
4
3x5
5x6
2-9-10
2-9-0
-2-9-4
2-9-4
2-9-10
2-9-10
3-7-14
5-3-6
0-4-15
4-10
-7
5-3-6
6.9512
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.84
0.40
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.02
-0.17
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 17 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF 2100F 1.8E
BOT CHORD2x4SPF No.2
WEBS 2x6SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 2-9-10 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)5=314/0-9-12(min. 0-1-8), 3=-39/Mechanical, 4=-20/Mechanical
Max Horz5=191(LC 8)
Max Uplift5=-82(LC 6), 3=-128(LC 12), 4=-61(LC 8)
MaxGrav5=551(LC 12), 3=117(LC 6), 4=65(LC 6)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-5=-484/126
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 4 except(jt=lb)
3=128.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-60
Trapezoidal Loads(plf)
Vert: 2=-4(F=28,B=28)-to-3=-42(F=9,B=9), 5=-0(F=10,B=10)-to-4=-14(F=3,B=3)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J09
TrussType
Jack-Open
Qty
3
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:422014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-FUG8cg45eVAn0f92c3slw85FGv5oxDhoSaFKjbzWRWF
Scale=1:30.8
W1
T1
B1
1
2
5
3
43x5
3x8
1-6-0
1-6-0
-1-4-8
1-4-8
1-6-0
1-6-0
3-7-14
5-4-14
4-9-12
5-4-14
14.0012
PlateOffsets(X,Y): [2:0-2-0,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.39
0.72
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.01
-0.19
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 13 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x6SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 1-6-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 9-1-11 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)5=208/0-5-8(min. 0-1-8), 4=-6/Mechanical, 3=-5/Mechanical
Max Horz5=254(LC 10)
Max Uplift5=-70(LC 8), 4=-303(LC 10), 3=-222(LC 10)
MaxGrav5=414(LC 10), 4=50(LC 8), 3=43(LC 8)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-5=-269/32
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS
forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5 except(jt=lb)
4=303, 3=222.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J10
TrussType
Jack-Open
Qty
8
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:422014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-FUG8cg45eVAn0f92c3slw85Abv6YxDhoSaFKjbzWRWF
Scale=1:30.0
W1
T1
B1
1
2
5
3
4
3x8
4x8
1-9-0
1-9-0
-1-0-0
1-0-0
1-9-0
1-9-0
3-2-10
5-3-2
4-8-0 5-3-2
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.75
0.67
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.01
-0.28
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 10 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 1-9-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)5=157/0-5-8(min. 0-1-8), 4=13/Mechanical, 3=26/Mechanical
Max Horz5=227(LC 10)
Max Uplift5=-42(LC 8), 4=-189(LC 10), 3=-190(LC 10)
MaxGrav5=284(LC 10), 4=39(LC 8), 3=38(LC 8)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS
forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)TheFabricationTolerance at joint 2 = 5%
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7) Refer to girder(s) for truss to trussconnections.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5 except(jt=lb)
4=189, 3=190.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J12
TrussType
Jack-OpenGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:422014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-FUG8cg45eVAn0f92c3slw85AMvCOxDhoSaFKjbzWRWF
Scale=1:29.0
W1
T1
B1
1
2
5
6
3
4
3x4
4x6
3-3-12
3-3-1
-2-0-3
2-0-3
3-3-12
3-3-12
3-2-10
5-1-10
6.9512
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.77
0.29
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.02
-0.02
0.14
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 16 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x6SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-3-12 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)5=222/0-9-12(min. 0-1-8), 3=19/Mechanical, 4=-0/Mechanical
Max Horz5=163(LC 8)
Max Uplift5=-39(LC 6), 3=-50(LC 8), 4=-40(LC 8)
MaxGrav5=364(LC 12), 3=99(LC 6), 4=61(LC 6)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-5=-319/81
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 3, 4.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-60
Trapezoidal Loads(plf)
Vert: 2=-4(F=28,B=28)-to-3=-50(F=5,B=5), 5=-0(F=10,B=10)-to-4=-17(F=2,B=2)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J13
TrussType
Jack-Open
Qty
3
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:432014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-jhqWq?5kPoIeepkEAnN_TMeUkIcyggwyhE?tG1zWRWE
Scale=1:9.9
T1
B1
1
2
3
4
2x4
1-4-0
1-4-0
-1-0-0
1-0-0
1-4-0
1-4-0
0-5-6
1-4-1
1-10
-14
0-10
-13
1-4-1
8.0012
PlateOffsets(X,Y): [2:0-2-4,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.15
0.02
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
-0.00
(loc)
2
2
3
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 5 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 1-4-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)2=139/0-5-8(min. 0-1-8), 4=13/Mechanical, 3=13/Mechanical
Max Horz2=76(LC 10)
Max Uplift2=-79(LC 10), 3=-35(LC 14)
MaxGrav2=191(LC 14), 4=26(LC 5), 3=15(LC 8)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS
forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 3.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J14
TrussType
Jack-Open
Qty
2
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:432014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-jhqWq?5kPoIeepkEAnN_TMeTTIcLggwyhE?tG1zWRWE
Scale=1:13.3
W1T1
B1
1
2
5
3
4
1.5x4
3x4
0-9-8
0-9-8
-1-0-0
1-0-0
0-9-8
0-9-8
0-11
-12
1-10
-14
2-6-8
1-3-12
1-10
-14
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.23
0.06
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
-0.00
(loc)
5
5
3
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 5 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 0-9-8 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)5=156/0-5-8(min. 0-1-8), 4=-9/Mechanical, 3=-28/Mechanical
Max Horz5=130(LC 10)
Max Uplift5=-35(LC 10), 4=-48(LC 10), 3=-81(LC 14)
MaxGrav5=258(LC 14), 4=7(LC 5), 3=21(LC 8)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS
forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 4, 3.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J15
TrussType
Jack-Open
Qty
6
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:432014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-jhqWq?5kPoIeepkEAnN_TMeNvIX3ggwyhE?tG1zWRWE
Scale=1:26.3
W1
T1
B11
2
5
6
7
3
4
3x5
3x8
2-7-6
2-7-6
-1-4-0
1-4-0
2-7-6
2-7-6
1-6-7
4-7-0
5-0-10
3-11
-14
4-7-0
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.59
0.33
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.02
0.02
-0.06
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 12 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 2-7-6 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)5=212/0-5-8(min. 0-1-8), 3=49/Mechanical, 4=19/Mechanical
Max Horz5=255(LC 10)
Max Uplift3=-119(LC 10), 4=-53(LC 10)
MaxGrav5=265(LC 14), 3=58(LC 3), 4=44(LC 5)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)-1-4-0 to 1-8-0,Interior(1) 1-8-0 to 2-6-10zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 4 except(jt=lb)
3=119.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J16
TrussType
Jack-Open
Qty
2
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:442014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-CtNu1L6MA6QVFzJQkUuD?ZBa6iuqP7A5wukQoUzWRWD
Scale=1:20.9
W1
T1
B11
2
5
3
4
3x4
3x6
1-8-4
1-8-4
-1-4-0
1-4-0
1-8-4
1-8-4
1-6-7
3-6-1
3-11
-11
2-10
-15 3-6-1
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.49
0.23
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
-0.03
(loc)
5
5
3
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 9 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 1-8-4 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)5=193/0-5-8(min. 0-1-8), 4=6/Mechanical, 3=13/Mechanical
Max Horz5=211(LC 10)
Max Uplift5=-10(LC 8), 4=-67(LC 10), 3=-73(LC 10)
MaxGrav5=277(LC 14), 4=26(LC 5), 3=28(LC 8)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS
forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 4, 3.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J17
TrussType
Jack-Open
Qty
2
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:442014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-CtNu1L6MA6QVFzJQkUuD?ZBbXiv9P7A5wukQoUzWRWD
Scale=1:15.7
W1
T1
B11
2
5
3
4
3x4
3x5
0-10-0
0-10-0
-1-4-0
1-4-0
0-10-0
0-10-0
1-6-7
2-6-1
2-11
-11
1-10
-15
2-6-1
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.40
0.15
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
-0.01
(loc)
5
5
3
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 6 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 0-10-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)5=213/0-5-8(min. 0-1-8), 4=-11/Mechanical, 3=-60/Mechanical
Max Horz5=168(LC 10)
Max Uplift5=-27(LC 8), 4=-126(LC 10), 3=-142(LC 14)
MaxGrav5=363(LC 14), 4=7(LC 5), 3=31(LC 8)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-5=-322/148
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS
forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5 except(jt=lb)
4=126, 3=142.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J18
TrussType
Jack-Open
Qty
2
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:442014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-CtNu1L6MA6QVFzJQkUuD?ZBdsiw5P7A5wukQoUzWRWD
Scale=1:13.8
T1
B1
HW1
1
2
5
6
3
4
3x5
3-1-10
3-1-10
-1-4-0
1-4-0
3-1-10
3-1-10
0-7-4
2-2-1
2-6-11
1-9-6
2-2-1
6.0012
PlateOffsets(X,Y): [2:0-2-8,0-0-7]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.32
0.09
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
-0.00
(loc)
2-4
2-4
3
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 10 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEDGE
Left: 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-1-10 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)3=59/Mechanical, 2=233/0-5-8(min. 0-1-8), 4=28/Mechanical
Max Horz2=102(LC 10)
Max Uplift3=-50(LC 10), 2=-110(LC 10)
MaxGrav3=71(LC 3), 2=281(LC 14), 4=57(LC 5)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)-1-4-0 to 1-8-0,Interior(1) 1-8-0 to 3-0-14zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 3 except(jt=lb)
2=110.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
J19
TrussType
DiagonalHipGirder
Qty
2
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:452014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-g3xGEh7_xQYLt7udHBPSYnjeB6A78aQE8YU_KwzWRWC
Scale=1:26.5
W1
T1
B11
2
5
6
7
8
9
3
10 11 12
4
3x5
3x10
6-4-2
6-3-4
-3-4-10
3-4-10
3-2-1
3-2-1
6-4-2
3-2-1
1-6-7
4-5-7
4-11
-11
0-6-12
3-10
-11
4-5-7
5.5212
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.92
0.48
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.13
0.11
-0.08
(loc)
4-5
4-5
3
l/defl
>571
>672
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 28 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x6SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x6SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)5=470/1-0-3(min. 0-1-8), 3=86/Mechanical, 4=32/Mechanical
Max Horz5=248(LC 8)
Max Uplift5=-381(LC 8), 3=-149(LC 8), 4=-55(LC 9)
MaxGrav5=608(LC 12), 3=128(LC 3), 4=84(LC 5)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-5=-525/286
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 4 except(jt=lb)
5=381, 3=149.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
10) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 38 lb down and 41 lb up at
1-5-1, and 5 lb down and 40 lb up at 2-2-2, and 72 lb up at 4-4-4 on top chord, and 17 lb down at 1-5-1, and 136 lb up at 2-2-2,
and 77 lb up at 4-4-4 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
11)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-60, 2-3=-60, 4-5=-20
Concentrated Loads(lb)
Vert: 6=1(B) 7=40(F) 9=47(F) 10=-8(B) 11=19(F) 12=14(F)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
PB01
TrussType
Piggyback
Qty
6
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:452014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-g3xGEh7_xQYLt7udHBPSYnjra6Fz8aQE8YU_KwzWRWC
Scale=1:13.1
T1 T1
B11
2
3
4
5
3x4
2x4 2x4
5-5-10
5-5-10
2-8-13
2-8-13
5-5-10
2-8-13
0-4-7
1-9-14
0-1-10
0-4-7
0-1-10
8.0012
PlateOffsets(X,Y): [3:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.06
0.17
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
5
5
4
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 12 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 5-5-10 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)2=187/3-11-6(min. 0-1-8), 4=187/3-11-6(min. 0-1-8)
Max Horz2=-46(LC 8)
Max Uplift2=-62(LC 10), 4=-62(LC 11)
MaxGrav2=202(LC 2), 4=202(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS
forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Gablerequirescontinuous bottomchord bearing.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 4.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
11)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T01GE
TrussType
Common SupportedGable
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:462014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-8FVeS17cijgCVHTprvwh4_Gz7WbltwzONCDXsMzWRWB
Scale=1:53.0
W1
T1 T2
W2
B1
ST3
ST2
ST1
ST2
ST1
1
2
3
4
5
6
7
8
15 14 13 12 11 10 9
16 17
2x4
3x5
4x4
2x4
2x41.5x31.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
12-8-4
12-8-4
-1-0-0
1-0-0
6-4-4
6-4-4
12-8-4
6-4-0
0-11
-12
8-4-11
9-0-5
1-0-0
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.27
0.14
0.49
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
1
1
9
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 69 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud*Except*
ST3: 2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS All bearings 12-8-4.
(lb)-Max Horz15=313(LC 9)
Max UpliftAll uplift 100 lb orless at joint(s) except 15=-181(LC 8), 9=-123(LC 9), 13=-138(LC 10), 14=-244(LC
10), 11=-135(LC 11), 10=-255(LC 11)
MaxGravAllreactions 250 lb orless at joint(s) 15, 9, 13, 14, 11, 10 except 12=395(LC 11)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 4-16=-76/343, 5-16=-20/352, 5-17=-22/351, 6-17=-88/340
WEBS 5-12=-446/0, 7-10=-150/250
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-C Corner(3)-1-0-0 to 2-0-0,Exterior(2) 2-0-0 to 6-4-4, Corner(3) 6-4-4 to 9-4-4zone;cantileverleft and right exposed ; end
verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
7)Gablerequirescontinuous bottomchord bearing.
8)Truss to be fullysheathed from one face orsecurely braced againstlateralmovement(i.e. diagonalweb).
9)Gablestudsspaced at 2-0-0 oc.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 181 lb uplift at joint 15, 123 lb uplift at
joint 9, 138 lb uplift at joint 13, 244 lb uplift at joint 14, 135 lb uplift at joint 11 and 255 lb uplift at joint 10.
12)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
13)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T02
TrussType
Roof Special
Qty
4
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:462014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-8FVeS17cijgCVHTprvwh4_Gy1WZJtzlONCDXsMzWRWB
Scale=1:87.0
T1
T2
T3
T4 T5
B1
W1
W2
W3 W4
W5
W6 W7
W8
W9
W11
W10
T6
B3B212
3
4
5
6
7
8
9
10
17 16 15 14 13 12 11
18
19
20
21
22
23
24
6x8
5x6
5x6
4x4
3x5
5x6 3x4 3x4
3x4
3x8
3x4
3x6 2x4
4x6
3x5
2-0-0
2-0-0
4-0-0
2-0-0
7-8-10
3-8-10
11-5-4
3-8-10
16-5-2
4-11-14
21-8-8
5-3-6
-1-0-0
1-0-0
0-6-0
0-6-0
2-0-0
1-6-0
4-0-0
2-0-0
7-8-10
3-8-10
11-5-4
3-8-10
16-5-2
4-11-14
21-8-8
5-3-6
0-6-7
0-10
-15
2-2-11
4-3-11
12
-11
-13
13
-6-12
1-0-0
9.0012
10.5012
12.5012
14.0012
PlateOffsets(X,Y): [3:0-2-13,0-2-8], [4:0-5-0,0-2-8], [5:0-5-8,0-2-8], [6:0-1-4,0-1-8], [8:0-1-4,0-1-8], [10:0-3-4,0-0-8], [12:0-2-4,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.34
0.29
0.32
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.03
-0.07
0.02
(loc)
15
12-14
11
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 138 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2 *Except*
B1: 2x6SPF No.2
WEBS 2x4SPFStud*Except*
W5,W6,W7,W8: 2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 5-4-7 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 6-14, 7-14, 8-14
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)2=918/0-5-8(min. 0-1-9), 11=851/0-5-8(min. 0-1-8)
Max Horz2=450(LC 9)
Max Uplift2=-231(LC 10), 11=-193(LC 10)
MaxGrav2=1003(LC 2), 11=917(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-1030/222, 3-4=-1060/236, 4-18=-1064/267, 5-18=-1040/277, 5-6=-923/316,
6-19=-703/367, 19-20=-620/377, 7-20=-604/393, 7-21=-572/371, 21-22=-604/355,
22-23=-621/353, 8-23=-747/337, 8-9=-739/247, 9-24=-820/230, 10-24=-971/225,
10-11=-868/219
BOT CHORD 2-17=-285/763, 16-17=-285/760, 15-16=-252/727, 14-15=-194/548, 13-14=-50/558,
12-13=-50/558
WEBS 5-15=-261/182, 6-15=-94/279, 6-14=-397/345, 7-14=-440/659, 8-14=-302/331,
10-12=-60/437
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)-1-0-0 to 0-6-0,Interior(1) 0-6-0 to 11-5-4,Exterior(2) 11-5-4 to 14-5-4zone;cantileverleft and right exposed ; end
verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 231 lb uplift at joint 2 and 193 lb uplift at
joint 11.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T02GE
TrussType
GABLE
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:472014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-cS31fN8ET1o36R2?PcRwdCp7wwwzcKhXcsz5PozWRWA
Scale=1:87.0
T1
T2
T3
T4 T5
W1
W2
W3 W4
W5 W6
W7
W8
W9
W11
W10
T6
B3B2
ST5
ST6
ST3
ST4ST2ST1
ST7
ST8
ST9
ST10 ST11
ST12
1
2 3
4
5
6
7
8
9
10
20 1918 17 16 15 14 13 12 11
37
38
39
40
41
42
43
3x54x6
5x6
4x4
3x5
3x4
5x6 3x4 3x4
3x4
3x8
3x4
3x6 2x4
4x6
3x5
2x42x4
2x4
2-0-0
2-0-0
4-0-0
2-0-0
7-8-10
3-8-10
11-5-4
3-8-10
16-5-2
4-11-14
21-8-8
5-3-6
-1-0-0
1-0-0
0-6-0
0-6-0
2-0-0
1-6-0
4-0-0
2-0-0
7-8-10
3-8-10
11-5-4
3-8-10
16-5-2
4-11-14
21-8-8
5-3-6
0-6-7
0-10
-15
2-2-11
4-3-11
12
-11
-13
13
-6-12
1-0-0
9.0012
10.5012
12.5012
14.0012
PlateOffsets(X,Y): [2:0-1-2,0-1-8], [4:0-5-4,0-2-0], [5:0-5-4,0-2-8], [6:0-1-4,0-1-8], [8:0-1-4,0-1-8], [10:Edge,0-3-8], [12:0-2-4,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.33
0.20
0.66
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.02
-0.04
0.01
(loc)
11-12
11-12
11
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 188 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2 *Except*
B1: 2x6SPF No.2
WEBS 2x4SPFStud*Except*
W5,W6,W7,W8: 2x4SPF No.2
OTHERS 2x4SPFStud*Except*
ST7: 2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 6-16, 8-14
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS All bearings 9-5-12 except(jt=length) 11=0-5-8.
(lb)-Max Horz2=454(LC 9)
Max UpliftAll uplift 100 lb orless at joint(s) 18, 11, 15, 20 except 2=-126(LC 8),
16=-322(LC 10)
MaxGravAllreactions 250 lb orless at joint(s) 2, 19, 18, 15, 17, 20 except
16=607(LC 2), 11=636(LC 22)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 6-38=-339/244, 38-39=-256/254, 7-39=-238/270, 41-42=-280/205, 8-42=-406/190,
8-9=-415/104, 9-43=-496/88, 10-43=-647/82, 10-11=-589/102
BOT CHORD 2-20=-230/278, 19-20=-232/280, 18-19=-230/279, 17-18=-203/293, 16-17=-203/293,
15-16=-160/302, 14-15=-160/302, 13-14=-16/351, 12-13=-16/351
WEBS 6-16=-571/259, 6-14=-47/258, 8-14=-327/341
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)-1-0-0 to 0-6-0,Interior(1) 0-6-0 to 11-5-4,Exterior(2) 11-5-4 to 14-5-4zone;cantileverleft and right exposed ; end
verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
7)All plates are 1.5x4MT20 unless otherwiseindicated.
8)Gablestudsspaced at 2-0-0 oc.
9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 18, 11, 15, 20
except(jt=lb) 2=126, 16=322.
11)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T02GE
TrussType
GABLE
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:472014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-cS31fN8ET1o36R2?PcRwdCp7wwwzcKhXcsz5PozWRWA
NOTES
12)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T03
TrussType
ROOF SPECIALGIRDER
Qty
1
Ply
3
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:482014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-4edPtj9sELxwkadCzKy9APLEEJDsLk6hrWiexFzWRW9
Scale=1:87.0
T1
T2
T4 T5
B1
W1 W3
W4 W5
W6 W7
W8 W9
W10
W11 W12
W13 W14
W15
W16
HW2
T6
B21
2
3
4
5
6
7
8
9
10
11
12
13
22 21 20 19 18 17 16 15 14
23
24
25
26
27 28 29 30 31 32
6x8
6x12MT18H
5x12MT18H
4x8
3x5
6x8
3x6 6x8
3x5
6x6
3x8
5x6
3x8
12x12
3x6
6x6
3x5
6x6
6x16MT18H
10x20MT18H
2-0-0
2-0-0
4-6-8
2-6-8
6-10-1
2-3-9
9-1-11
2-3-9
11-5-4
2-3-9
14-5-7
3-0-3
17-5-9
3-0-3
20-5-12
3-0-3
21-8-8
1-2-12
-1-0-0
1-0-0
0-6-0
0-6-0
2-0-0
1-6-0
4-0-0
2-0-0
4-6-8
0-6-8
6-10-1
2-3-9
9-1-11
2-3-9
11-5-4
2-3-9
14-5-7
3-0-3
17-5-9
3-0-3
20-5-12
3-0-3
21-8-8
1-2-12
0-6-7
0-10
-15
2-2-11
4-3-11
12
-11
-13
13
-6-12
1-0-0
9.0012
10.5012
12.5012
14.0012
PlateOffsets(X,Y): [2:0-2-9,0-2-4], [4:0-6-0,0-1-4], [5:0-1-4,0-1-8], [6:0-2-8,0-1-8], [7:0-2-8,0-1-8], [8:Edge,0-2-0], [9:0-1-8,0-1-8], [10:0-1-12,0-1-8], [12:0-4-4,0-3-0], [13:Edge
,0-5-4], [14:20-3-0,0-7-4], [15:0-3-0,0-3-12], [16:0-3-0,0-3-12], [18:0-2-12,0-2-8], [19:0-2-8,0-3-12], [21:0-2-0,0-3-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.61
0.42
0.84
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.16
-0.30
0.02
(loc)
18-19
18-19
13
l/defl
>999
>837
n/a
L/d
360
240
n/a
PLATES
MT20
MT18H
Weight: 671 lb FT= 10%
GRIP
197/144
197/144
LUMBER
TOP CHORD2x4SPF No.2 *Except*
T2: 2x8SP 2400F 2.0E
BOT CHORD2x8SP 2400F 2.0E
WEBS 2x4SPFStud*Except*
W7,W8,W9,W11,W12: 2x4SPF No.2, W10: 2x4SPF 1650F 1.5E
W16: 2x6SPF No.2
SLIDER Right 2x6SP 2400F 2.0E 1-5-10
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 5-0-6 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)2=8709/0-5-8(min. 0-3-4), 13=10152/0-5-8(min. 0-3-12)
Max Horz2=466(LC 7)
Max Uplift2=-2756(LC 8), 13=-3075(LC 8)
MaxGrav2=11746(LC 2), 13=13536(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-14067/3286, 3-23=-14973/3498, 4-23=-14895/3507, 4-5=-15032/3559,
5-6=-13092/3094, 6-24=-10940/2664, 7-24=-10848/2673, 7-8=-9194/2356,
8-25=-9133/2352, 25-26=-9243/2336, 9-26=-9270/2333, 9-10=-11147/2660,
10-11=-12624/2900, 11-12=-12667/2882, 12-13=-14112/3185
BOT CHORD 2-22=-2578/10894, 21-22=-2474/10477, 20-21=-2338/9826, 20-27=-2338/9826,
19-27=-2338/9826, 19-28=-1977/8464, 18-28=-1977/8464, 18-29=-1629/7045,
17-29=-1629/7045, 17-30=-1571/7176, 16-30=-1571/7176, 16-31=-1772/8216,
15-31=-1772/8216, 15-32=-1544/6892, 14-32=-1544/6892, 13-14=-1544/6892
WEBS 3-22=-1682/416, 3-21=-487/168, 5-21=-997/3777, 5-19=-2949/871, 6-19=-1425/5834,
6-18=-4605/1261, 7-18=-1347/5538, 7-17=-4380/1201, 8-17=-3437/13593,
9-17=-3566/1031, 9-16=-1116/4656, 10-16=-2144/645, 10-15=-637/2818,
12-15=-353/1566, 12-14=-426/1786
NOTES
1) 3-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x8- 2 rowsstaggered at 0-9-0 oc.
Bottomchordsconnected as follows: 2x8- 3 rowsstaggered at 0-5-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc,Exceptmember 21-4 2x4- 2 rowsstaggered at 0-6-0 oc,member 5-21 2x4- 2
rowsstaggered at 0-6-0 oc, 2x6- 2 rowsstaggered at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3) Unbalancedroofliveloads have been considered for this design.
4)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T03
TrussType
ROOF SPECIALGIRDER
Qty
1
Ply
3
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:482014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-4edPtj9sELxwkadCzKy9APLEEJDsLk6hrWiexFzWRW9
NOTES
6) Unbalancedsnowloads have been considered for this design.
7)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs non-concurrentwith otherliveloads.
8)All plates areMT20 plates unless otherwiseindicated.
9)TheFabricationTolerance at joint 13 = 5%
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 2=2756, 13=3075.
12)Followingjoints to be plated by qualified designer:Joint(s) 14, not plated.
13)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
14)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
15) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 3937 lb down and 1063 lb up at 4-6-8, 2569 lb down and 510 lb up at
6-6-8, 2387 lb down and 524 lb up at 8-6-8, 2427 lb down and 517 lb up at 10-6-8, 2430 lb down and 616 lb up at 12-6-8, 2765 lb down and 617 lb up at 14-6-8, 2386 lb
down and 497 lb up at 16-6-8, and 2207 lb down and 480 lb up at 18-6-8, and 2267 lb down and 574 lb up at 20-5-12 on bottomchord.The design/selection of such
connection device(s)is the responsibility of others.
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-60, 2-3=-60, 3-4=-60, 4-8=-60, 8-13=-60, 2-13=-20
Concentrated Loads(lb)
Vert: 21=-3100(B) 16=-1919(B) 14=-1948(B) 27=-1917(B) 28=-1588(B) 29=-1588(B) 30=-1588(B) 31=-1722(B) 32=-1722(B)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T04
TrussType
Roof Special
Qty
2
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:482014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-4edPtj9sELxwkadCzKy9APLFaJDJLqghrWiexFzWRW9
Scale=1:61.4
W1
T1
T2
T3
T4
B1
W2
W3
W4 W5
W6 W7
W8
1
2
3
4
5
6
11 10 9 8 7
12
1.5x3
5x6
5x6
4x6
3x43x43x41.5x3
3x4
3x4
2-0-7
2-0-7
5-3-14
3-3-7
7-10-15
2-7-1
10-2-8
2-3-9
10-5-14
0-3-6
2-0-7
2-0-7
5-3-14
3-3-7
7-10-15
2-7-1
10-5-14
2-6-15
11-8-6
1-2-8
10
-7-0
10
-10
-8
8-5-15
5-0-15
3-0-5
0-3-8
1-3-11
14.0012
12.5012
9.5012
8.0012
PlateOffsets(X,Y): [2:0-5-4,0-2-8], [3:0-5-0,0-2-8], [4:0-5-0,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.53
0.39
0.48
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.03
-0.05
0.00
(loc)
9-10
8-9
7
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 82 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud*Except*
W1,W2,W3: 2x4SPF No.2, W8: 2x6SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 1-11, 2-11
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)7=497/0-4-0(min. 0-1-8), 11=398/0-1-8(min. 0-1-8)
Max Horz11=-481(LC 11)
Max Uplift7=-84(LC 11), 11=-463(LC 11)
MaxGrav7=581(LC 4), 11=472(LC 4)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 3-4=-365/52, 4-12=-342/118, 5-12=-430/106, 5-7=-471/197
BOT CHORD 10-11=-46/391, 9-10=-49/266, 8-9=-36/262, 7-8=-35/266
WEBS 2-11=-405/526, 2-10=-405/279, 3-10=-304/354, 3-9=-280/163
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 2-0-7,Interior(1) 2-0-7 to 11-8-6zone;cantileverright exposed ; end verticalright exposed; porchright
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Bearing at joint(s) 11 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
7)Providemechanicalconnection(by others) of truss to bearing plate at joint(s) 11.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 7 except(jt=lb)
11=463.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T04GE
TrussType
Roof Special
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:492014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-YqBn43AU?e3nMkCOW1UOiduL3jag4Htq3ASBThzWRW8
Scale=1:66.3
W1
T1
T2
T3
T4
B1
W2
W3
W4 W5
W6 W7W8
W9 W10
1
2
3
4
5
6
7
13 12 11 10 9 814151617
1.5x3
5x6
5x6
4x6
4x43x43x43x4
3x4
1.5x4
3x5
3x5
2-0-7
2-0-7
5-3-14
3-3-7
7-10-15
2-7-1
8-9-2
0-10-3
10-2-8
1-5-6
10-5-14
0-3-6
2-0-7
2-0-7
5-3-14
3-3-7
7-10-15
2-7-1
8-9-2
0-10-3
10-5-14
1-8-12
11-8-6
1-2-8
10
-5-0
10
-10
-8
8-5-15
5-0-15
3-0-5
0-5-8
1-3-11
14.0012
12.5012
9.5012
8.0012
PlateOffsets(X,Y): [2:0-5-4,0-2-8], [3:0-5-0,0-2-8], [4:0-5-0,0-2-0], [5:0-1-12,0-1-8], [8:Edge,0-3-8], [13:0-1-12,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.86
0.38
0.48
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.02
-0.04
0.00
(loc)
11
11
8
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 90 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x6SPF No.2
WEBS 2x4SPFStud*Except*
W1,W2,W3: 2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 1-13, 2-13
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)8=708/0-4-0(min. 0-1-8), 13=678/0-1-8(min. 0-1-8)
Max Horz13=-477(LC 9)
Max Uplift8=-262(LC 9), 13=-672(LC 9)
MaxGrav8=841(LC 4), 13=782(LC 4)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-288/86, 3-4=-600/182, 4-5=-597/179, 5-6=-510/152, 6-8=-540/213
BOT CHORD 13-14=-82/352, 12-14=-82/352, 12-15=-158/441, 15-16=-158/441, 11-16=-158/441,
11-17=-176/540, 10-17=-176/540, 9-10=-102/313, 8-9=-102/313
WEBS 2-13=-642/541, 2-12=-424/559, 3-12=-509/409, 3-11=-325/375, 5-10=-168/537,
5-9=-406/91
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverright exposed ; end verticalright exposed; porchright exposed; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Bearing at joint(s) 13 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
7)Providemechanicalconnection(by others) of truss to bearing plate at joint(s) 13.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
8=262, 13=672.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
11) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 111 lb down and 101 lb up at
0-9-3, 111 lb down and 101 lb up at 2-9-3, 111 lb down and 101 lb up at 4-9-3, and 111 lb down and 101 lb up at 6-9-3, and 125
lb down and 124 lb up at 8-9-3 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
LOADCASE(S)Standard
Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T04GE
TrussType
Roof Special
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:492014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-YqBn43AU?e3nMkCOW1UOiduL3jag4Htq3ASBThzWRW8
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-60, 2-3=-60, 3-4=-60, 4-6=-60, 6-7=-60, 8-13=-20
Concentrated Loads(lb)
Vert: 9=-82 14=-102 15=-102 16=-102 17=-102
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T05
TrussType
ROOF SPECIAL
Qty
4
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:492014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-YqBn43AU?e3nMkCOW1UOiduTxjYb4Khq3ASBThzWRW8
Scale=1:62.5
W1
T1
T2
T3
T4
B1
W2
W3
W4 W5
W6 W7 W8
1
2
3
4
5
10 9 8 7 6
11
3x5
5x6
5x6
5x6
3x4
3x4
3x4 3x4 1.5x35x6
2-0-7
2-0-7
5-3-14
3-3-7
7-10-15
2-7-1
10-2-8
2-3-9
10-5-14
0-3-6
2-0-7
2-0-7
5-3-14
3-3-7
7-10-15
2-7-1
10-5-14
2-6-15
10
-7-0
10
-10
-8
8-5-15
5-0-15
3-0-5
0-3-8
1-3-11
14.0012
12.5012
9.5012
8.0012
PlateOffsets(X,Y): [1:0-1-9,0-1-8], [2:0-5-4,0-2-8], [3:0-5-0,0-2-8], [4:0-4-12,0-2-8], [10:Edge,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.36
0.45
0.30
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.03
-0.06
0.01
(loc)
7-8
7-8
6
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 80 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud*Except*
W1: 2x4SPF 2100F 1.8E,W2,W3: 2x4SPF No.2, W8: 2x6SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 1-10, 2-10
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)6=405/0-4-0(min. 0-1-8), 10=405/0-1-8(min. 0-1-8)
Max Horz10=-434(LC 8)
Max Uplift6=-46(LC 9), 10=-245(LC 8)
MaxGrav6=466(LC 4), 10=473(LC 4)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-374/211, 3-4=-371/140, 4-11=-339/107, 5-11=-420/95, 5-6=-340/105
BOT CHORD 9-10=-179/497, 8-9=-131/410, 7-8=-69/273, 6-7=-71/278
WEBS 2-10=-406/315, 2-9=-255/283, 3-9=-312/191
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 2-0-7,Interior(1) 2-0-7 to 10-3-2zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
5)Bearing at joint(s) 10 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
6)Providemechanicalconnection(by others) of truss to bearing plate at joint(s) 10.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 6 except(jt=lb)
10=245.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T06GE
TrussType
Monopitch SupportedGable
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:502014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-01l9IPB7myBezuna4l?dFqQYB7rvpqkzIqBl?7zWRW7
Scale=1:66.8
W1
T2
W2
B1
B2ST1
ST1
ST1
ST1
ST1
ST1
T11
2 3
4
5
6
7
8
9
18 17
16
15
14
13
12
11 10
19
5x6
3x8
3x4
5x6
5x6
3x4
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
12-11-5
12-11-5
13-10-2
0-10-13
13-10-2
13-10-2
2-8-0
11
-10
-12
3-6-14
8-3-14
8.0012
8.0012
PlateOffsets(X,Y): [9:0-3-3,Edge], [10:Edge,0-3-8], [18:0-0-9,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.71
0.64
0.12
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.01
(loc)
-
-
10
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 61 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPF No.2
OTHERS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS All bearings 13-10-2.
(lb)-Max Horz18=379(LC 10)
Max UpliftAll uplift 100 lb orless at joint(s) 11, 14 except 18=-174(LC 8), 10=-470(LC 10), 13=-123(LC 10),
15=-113(LC 10), 17=-594(LC 10)
MaxGravAllreactions 250 lb orless at joint(s) 10, 12, 13, 14, 15, 16, 17 except 18=610(LC 10), 11=368(LC
10)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-18=-359/62, 1-2=-379/70
BOT CHORD 17-18=-444/143, 16-17=-261/102, 15-16=-302/112, 14-15=-290/109, 13-14=-293/110,
12-13=-296/110, 11-12=-265/99
WEBS 2-17=-132/399
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-C Corner(3) 0-1-12 to 3-1-12,Exterior(2) 3-1-12 to 13-8-6zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)Truss to be fullysheathed from one face orsecurely braced againstlateralmovement(i.e. diagonalweb).
7)Gablestudsspaced at 2-0-0 oc.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9)Bearing at joint(s) 18, 11, 12, 13, 14, 15, 16, 17 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building
designershouldverifycapacity of bearingsurface.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 11, 14 except
(jt=lb) 18=174, 10=470, 13=123, 15=113, 17=594.
11)Beveled plate orshimrequired to provide full bearingsurfacewith trusschord at joint(s) 10, 11, 12, 13, 14, 15, 16, 17.
12)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
13)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T07
TrussType
HalfHipGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:502014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-01l9IPB7myBezuna4l?dFqQb97nMpfSzIqBl?7zWRW7
Scale=1:82.1
0-2-5
W1
T2
T3
W9
B1
B2
W2
W3
W4
W3
W2
W5 W6
W7
T11
2
3
4
5
6 7
13
12
11
10 9 8
14
15
16 17
18 19
2x4
3x8
3x5
5x6 3x4
5x66x6
4x6
3x4
3x4
3x4
4x6
4x4
4-6-2
4-6-2
8-8-11
4-2-10
12-11-5
4-2-10
16-7-2
3-7-13
21-6-8
4-11-6
4-6-2
4-6-2
8-8-11
4-2-10
12-11-5
4-2-10
16-7-2
3-7-13
21-6-8
4-11-6
2-8-0
13
-6-7
13
-8-12
5-2-9
8-3-14
8.0012
8.0012
PlateOffsets(X,Y): [3:0-1-12,0-1-8], [4:0-1-12,0-1-8], [5:0-2-0,0-2-0], [6:0-3-0,0-1-8], [8:Edge,0-3-4], [9:0-1-12,0-1-8], [10:0-3-0,Edge], [11:0-1-12,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.52
0.86
0.78
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.26
-0.36
0.30
(loc)
10-11
10-11
8
l/defl
>987
>714
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 104 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-0-6 oc purlins,
except end verticals, and 2-0-0 oc purlins(6-0-0max.): 6-7.
BOT CHORD Rigidceiling directly applied or 4-0-3 oc bracing.
WEBS 1 Row at midpt 6-8
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)13=824/0-5-8(min. 0-1-8), 8=718/0-3-8(min. 0-1-8)
Max Horz13=418(LC 8)
Max Uplift13=-334(LC 8), 8=-1713(LC 8)
MaxGrav13=1163(LC 13), 8=932(LC 13)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-13=-1134/618, 1-2=-2086/1091, 2-3=-1942/1104, 3-14=-3163/1816, 4-14=-3047/1837,
4-5=-3042/2177, 5-15=-1159/1272, 6-15=-1031/1289, 7-8=-251/339
BOT CHORD 12-13=-489/265, 11-12=-1469/2040, 10-11=-2039/3058, 9-10=-1794/2318,
9-18=-1011/832, 18-19=-1011/832, 8-19=-1011/832
WEBS 1-12=-812/1659, 3-12=-908/537, 3-11=-481/857, 4-11=-436/327, 4-10=-366/0,
5-10=-1027/1751, 5-9=-1874/998, 6-9=-1273/1224, 6-8=-1193/1439
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Bearing at joint(s) 13 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
13=334, 8=1713.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
11)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
12) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 231 lb up at 16-7-2, and 213
lb up at 18-7-14, and 213 lb up at 20-7-14 on top chord, and 385 lb up at 16-7-2, and 313 lb up at 18-7-14, and 313 lb up at
20-7-14 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
13)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)StandardContinued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T07
TrussType
HalfHipGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:502014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-01l9IPB7myBezuna4l?dFqQb97nMpfSzIqBl?7zWRW7
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-6=-60, 6-7=-60, 10-13=-20, 8-10=-20
Concentrated Loads(lb)
Vert: 6=54(F) 9=33(F) 16=21(F) 17=21(F) 18=14(F) 19=14(F)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T08
TrussType
HalfHip
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:512014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-UDIXVkBlXGJVb2LneSWsn2zgtX8?Y4B7XUxIYazWRW6
Scale:1/8"=1'
0-2-5
W1
T2
T3
W8
B1
B2
W2
W3
W2
W4
W5 W6
W7
T1
1
2
3
4
5 6
11
10
9 8 7
12
13
3x4
4x10
3x5
6x6 3x4
4x46x6
4x8
3x4
4x6
4x6
6-7-6
6-7-6
12-11-5
6-3-14
20-1-2
7-1-13
21-6-8
1-5-6
6-7-6
6-7-6
12-11-5
6-3-14
20-1-2
7-1-13
21-6-8
1-5-6
2-8-0
15
-10
-7
16
-0-12
7-6-9
8-3-14
8.0012
8.0012
PlateOffsets(X,Y): [1:Edge,0-1-12], [2:0-1-12,0-1-8], [4:0-2-4,0-2-0], [7:0-1-12,0-1-12], [9:0-2-12,0-3-0], [10:0-2-8,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.91
0.77
0.94
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.24
-0.47
0.36
(loc)
9-10
9-10
7
l/defl
>999
>537
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 113 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud*Except*
W5,W6,W7: 2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied, except end verticals, and
2-0-0 oc purlins(10-0-0max.): 5-6.
BOT CHORD Rigidceiling directly applied or 5-0-3 oc bracing.
WEBS 1 Row at midpt 4-8, 5-7
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)11=850/0-5-8(min. 0-1-8), 7=850/0-3-8(min. 0-2-0)
Max Horz11=509(LC 9)
Max Uplift11=-87(LC 10), 7=-391(LC 10)
MaxGrav11=1110(LC 15), 7=1269(LC 15)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-11=-1083/423, 1-12=-2718/859, 2-12=-2607/879, 2-3=-3390/947, 3-4=-3066/979,
4-13=-580/122, 5-13=-333/145
BOT CHORD 10-11=-836/369, 9-10=-1367/2642, 8-9=-1065/2610, 7-8=-168/258
WEBS 1-10=-596/2191, 2-10=-719/307, 2-9=0/543, 4-9=-685/1705, 4-8=-2511/968,
5-8=-317/1054, 5-7=-1458/516
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 20-1-2,Exterior(2) 20-1-2 to 21-4-12zone;cantileverleft and right exposed ;
endverticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Bearing at joint(s) 11 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 11 except(jt=lb)
7=391.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
11)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T09
TrussType
Monopitch
Qty
2
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:512014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-UDIXVkBlXGJVb2LneSWsn2zmPXBMY747XUxIYazWRW6
Scale=1:94.3
W1
T2 W8
B1
B2
W2
W3
W2
W4 W5
W6
W7
T1
1
2
3
4
5
6
11
10
9 8 7
12
13
14
3x4
4x6
3x5
3x4
3x55x6
4x6
3x4
4x4
3x5
3x5
6-7-6
6-7-6
12-11-5
6-3-14
17-1-2
4-1-14
21-6-8
4-5-6
6-7-6
6-7-6
12-11-5
6-3-14
17-1-2
4-1-14
21-6-8
4-5-6
2-8-0
17
-0-5
8-8-7
8-3-14
8.0012
8.0012
PlateOffsets(X,Y): [1:0-2-12,0-1-8], [2:0-1-12,0-1-8], [4:0-1-0,0-1-12], [5:0-2-0,0-1-8], [6:0-2-0,0-1-4], [7:0-2-4,0-1-8], [8:0-2-4,0-1-8], [9:0-2-12,0-2-8], [10:0-2-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.55
0.62
0.76
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.18
-0.38
0.26
(loc)
9-10
9-10
7
l/defl
>999
>680
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 108 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud*Except*
W8: 2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-3-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 4-11-3 oc bracing.
WEBS 1 Row at midpt 6-7, 5-7
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)11=850/0-5-8(min. 0-1-8), 7=850/0-3-8(min. 0-1-12)
Max Horz11=555(LC 9)
Max Uplift11=-71(LC 10), 7=-423(LC 10)
MaxGrav11=940(LC 3), 7=1105(LC 3)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-11=-914/419, 1-12=-2216/862, 2-12=-2106/882, 2-3=-2450/908, 3-4=-2320/941,
4-13=-899/276, 5-13=-762/296
BOT CHORD 10-11=-896/400, 9-10=-1410/2132, 8-9=-1035/1861, 7-8=-387/689
WEBS 1-10=-603/1761, 2-10=-547/312, 4-9=-711/1312, 4-8=-1421/787, 5-8=-415/888,
5-7=-1097/515
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 21-4-12zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
5)Bearing at joint(s) 11 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 11 except(jt=lb)
7=423.
7)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
8)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T10
TrussType
Monopitch
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:512014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-UDIXVkBlXGJVb2LneSWsn2zmbXCUY3c7XUxIYazWRW6
Scale=1:93.3
W1
T2 W7
B1
B2
W2
W3
W2
W4 W5 W6
T1
1
2
3
4
5
6
10
9
8 7
11
12
13
3x4
4x6
3x5
3x4
3x56x10
4x6
3x4
1.5x4
4x6
6-7-6
6-7-6
12-11-5
6-3-14
21-3-4
8-3-15
6-7-6
6-7-6
12-11-5
6-3-14
16-11-9
4-0-4
21-3-4
4-3-12
2-8-0
16
-10
-3
8-6-5
8-3-14
8.0012
8.0012
PlateOffsets(X,Y): [1:Edge,0-1-12], [2:0-1-12,0-1-8], [5:0-1-4,0-2-0], [6:0-2-0,0-1-4], [8:0-6-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.54
0.55
0.98
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.19
-0.52
0.25
(loc)
7-8
7-8
7
l/defl
>999
>483
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 103 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud*Except*
W7: 2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-3-10 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 5-0-1 oc bracing.
WEBS 1 Row at midpt 6-7
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)10=839/0-5-8(min. 0-1-8), 7=839/Mechanical
Max Horz10=547(LC 9)
Max Uplift10=-69(LC 10), 7=-419(LC 10)
MaxGrav10=928(LC 3), 7=1090(LC 3)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-10=-901/414, 1-11=-2179/849, 2-11=-2069/869, 2-3=-2299/827, 3-4=-2167/859,
4-12=-2234/1010, 5-12=-2099/1029
BOT CHORD 9-10=-884/394, 8-9=-1375/2091, 7-8=-401/648
WEBS 1-9=-592/1730, 2-9=-511/288, 4-8=-326/268, 5-8=-1031/1965, 5-7=-1034/523
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 21-1-8zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
5) Refer to girder(s) for truss to trussconnections.
6)Bearing at joint(s) 10 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 10 except(jt=lb)
7=419.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T11
TrussType
HalfHipGirder
Qty
1
Ply
2
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:542014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-vo_g7mEdpBh4SV4LJa3ZPgbKukJ3lVbZDR9y8uzWRW3
Scale=1:77.9
0-2-5
T1
T2
W3
B1
W1 W2 W3 W2 W3 W2 W3 W2 W3 W2 W3 W2 W3 W2 W3 W2 W3 W2 W3 W2
T4T3
B3B212
3 4 5 6 7 8 9 10 11 12 13 14 15
28 27 26 25 24 23 22 21 20 19 18 17 16
29 30 31 32 33 34 35 36 37 38 39 40 4142 4344
45 46 47 48 49 5051 52 5354 5556 5758
6x6 4x8 5x6
2x4
4x6
4x82x44x4
4x4
4x4
4x4
4x4
4x4
4x4
4x4 2x4
4x8
4x4
4x4
4x4
4x4
4x4
4x4
4x4
4x6
4x8
4x8
3-10-4
3-10-4
7-8-4
3-9-15
11-7-15
3-11-11
15-7-10
3-11-11
19-7-5
3-11-11
23-7-0
3-11-11
27-6-11
3-11-11
31-6-7
3-11-11
35-6-2
3-11-11
39-5-13
3-11-11
43-7-4
4-1-7
-1-0-0
1-0-0
3-10-4
3-10-4
7-8-4
3-9-15
11-7-15
3-11-11
15-7-10
3-11-11
19-7-5
3-11-11
23-7-0
3-11-11
27-6-11
3-11-11
31-6-7
3-11-11
35-6-2
3-11-11
39-5-13
3-11-11
43-7-4
4-1-7
0-5-62-9-15
3-0-4
3-7-1
2-9-15
8.0012
PlateOffsets(X,Y): [3:0-3-0,0-0-8], [14:0-1-12,0-2-0], [18:0-1-12,0-2-0], [27:0-1-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.28
0.24
0.64
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.54
-0.64
0.08
(loc)
22-23
22-23
16
l/defl
>969
>814
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 546 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x6SP 2400F 2.0E*Except*
T1: 2x4SPF No.2
BOT CHORD2x6SP 2400F 2.0E
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins(6-0-0max.): 3-15.
BOT CHORD Rigidceiling directly applied or 9-4-8 oc bracing.
REACTIONS (lb/size)16=1293/0-4-0(min. 0-1-8), 2=1360/0-5-8(min. 0-1-8)
Max Horz2=109(LC 7)
Max Uplift16=-1317(LC 6), 2=-1144(LC 9)
MaxGrav16=1769(LC 13), 2=1637(LC 13)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-2688/2020, 3-29=-4350/3364, 29-30=-4350/3363, 4-30=-4354/3364,
4-31=-5901/4626, 5-31=-5901/4626, 5-32=-6848/5487, 32-33=-6848/5487,
6-33=-6848/5487, 6-7=-7276/5939, 7-8=-7276/5939, 8-34=-7272/5981, 34-35=-7272/5981,
9-35=-7272/5981, 9-36=-7272/5981, 36-37=-7272/5981, 10-37=-7272/5981,
10-38=-6844/5621, 38-39=-6844/5621, 11-39=-6844/5621, 11-40=-5993/4841,
12-40=-5993/4841, 12-13=-5993/4841, 13-41=-4618/3655, 41-42=-4618/3655,
14-42=-4618/3655, 14-43=-2619/2057, 43-44=-2619/2057, 15-44=-2619/2057,
15-16=-1709/1292
BOT CHORD 2-28=-1668/2188, 28-45=-1667/2184, 27-45=-1667/2184, 27-46=-3295/4348,
26-46=-3295/4348, 25-26=-4562/5901, 24-25=-4562/5901, 24-47=-5423/6848,
23-47=-5423/6848, 23-48=-5875/7276, 48-49=-5875/7276, 22-49=-5875/7276,
22-50=-5557/6844, 50-51=-5557/6844, 21-51=-5557/6844, 21-52=-4778/5993,
20-52=-4778/5993, 19-20=-4778/5993, 19-53=-3591/4618, 53-54=-3591/4618,
18-54=-3591/4618, 18-55=-1993/2619, 55-56=-1993/2619, 17-56=-1993/2619
WEBS 3-27=-2037/2581, 4-27=-1350/1075, 4-26=-1475/1808, 5-26=-869/729, 5-24=-1002/1102,
6-24=-501/481, 6-23=-526/544, 10-22=-419/498, 10-21=-442/428, 11-21=-907/990,
11-19=-759/680, 13-19=-1382/1601, 13-18=-1126/918, 14-18=-1860/2327,
14-17=-1491/1168, 15-17=-2317/2995
NOTES
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x6- 2 rowsstaggered at 0-9-0 oc.
Bottomchordsconnected as follows: 2x6- 2 rowsstaggered at 0-9-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3) Unbalancedroofliveloads have been considered for this design.
4)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T11
TrussType
HalfHipGirder
Qty
1
Ply
2
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:542014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-vo_g7mEdpBh4SV4LJa3ZPgbKukJ3lVbZDR9y8uzWRW3
NOTES
5)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flatroofsnow: Lumber DOL=1.15Plate
DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
6) Unbalancedsnowloads have been considered for this design.
7)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs non-concurrentwith otherliveloads.
8)Provide adequate drainage to preventwater ponding.
9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 16=1317, 2=1144.
11)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
12)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
13)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
14) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 85 lb up at 3-10-5, 86 lb up at 5-11-0, 86 lb up at 7-11-0, 86 lb up at
9-11-0, 86 lb up at 11-11-0, 86 lb up at 13-11-0, 58 lb up at 15-11-0, 58 lb up at 17-11-0, 58 lb up at 19-11-0, 58 lb up at 21-11-0, 58 lb up at 23-11-0, 58 lb up at
25-11-0, 58 lb up at 27-11-0, 58 lb up at 29-11-0, 58 lb up at 31-11-0, 86 lb up at 33-11-0, 86 lb up at 35-11-0, 86 lb up at 37-11-0, and 86 lb up at 39-11-0, and 86 lb
up at 41-11-0 on top chord, and 41 lb up at 3-10-5, 37 lb up at 5-11-0, 37 lb up at 7-11-0, 37 lb up at 9-11-0, 37 lb up at 11-11-0, 37 lb up at 13-11-0, 37 lb up at
15-11-0, 37 lb up at 17-11-0, 37 lb up at 19-11-0, 37 lb up at 21-11-0, 37 lb up at 23-11-0, 37 lb up at 25-11-0, 37 lb up at 27-11-0, 37 lb up at 29-11-0, 37 lb up at
31-11-0, 37 lb up at 33-11-0, 37 lb up at 35-11-0, 37 lb up at 37-11-0, and 37 lb up at 39-11-0, and 37 lb up at 41-11-0 on bottomchord.The design/selection of such
connection device(s)is the responsibility of others.
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-3=-60, 3-15=-60, 2-16=-20
Concentrated Loads(lb)
Vert: 3=69(B) 7=31(B) 25=10(B) 28=28(B) 27=10(B) 4=31(B) 26=10(B) 5=31(B) 24=10(B) 6=31(B) 12=31(B) 20=10(B) 30=31(B) 31=31(B) 32=31(B) 34=31(B)
35=31(B) 36=31(B) 37=31(B) 38=31(B) 39=31(B) 40=31(B) 41=31(B) 42=31(B) 43=31(B) 44=31(B) 45=10(B) 46=10(B) 47=10(B) 48=10(B) 49=10(B) 50=10(B)
51=10(B) 52=10(B) 53=10(B) 54=10(B) 55=10(B) 56=10(B) 57=10(B) 58=10(B)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T12
TrussType
HalfHip
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:552014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-N_Y2L6EFaUpx4ffYtIboyu8W78ZHUv?jS5vWhLzWRW2
Scale=1:77.2
0-2-5
T1
T2
W17
B1
B3
B4
B3
B5
B3
B6
B3
B7
W1 W2
W3 W4 W5 W6 W5 W6 W5
W8
W7 W9 W10 W11 W10 W9
W13
W12 W5
W13
W12 W14
W16
T3T2
B2
1
2
3 4 5 6 7 8 9 10 11 12 13 14 15 16
34 33 32 31 30 29 28
27 26 25 24
23 22 21
20 19
18 17
35
36
37 38 39
4x8
8x8 6x8 6x6
5x66x83x10
6x6
10x14MT18H
3x5
3x8 3x8
3x5
8x12MT18H
6x6
3x5
4x4
3x6
4x6
5x6
4x6
4x8
3x6 5x8
4x10
10x14MT18H
3x6
4x8
3x6
4x8
5x10
6x8
8x12MT18H
6x8
4-1-3
4-1-3
7-4-4
3-3-1
11-1-1
3-8-13
14-9-14
3-8-13
18-6-11
3-8-13
22-3-8
3-8-13
25-9-12
3-6-4
29-4-0
3-6-4
32-10-4
3-6-4
35-3-4
2-5-0
37-8-4
2-5-0
41-3-4
3-7-0
43-7-4
2-4-0
4-1-3
4-1-3
7-4-4
3-3-1
11-1-1
3-8-13
14-9-14
3-8-13
18-6-11
3-8-13
22-3-8
3-8-13
25-9-12
3-6-4
29-4-0
3-6-4
32-10-4
3-6-4
35-3-4
2-5-0
37-8-4
2-5-0
41-3-4
3-7-0
43-7-4
2-4-0
0-5-6
5-1-15
5-4-4
5-1-15
1-0-0
8.0012
PlateOffsets(X,Y): [2:0-1-12,0-2-0], [3:0-4-8,0-3-0], [6:0-1-8,0-2-0], [12:0-3-0,0-2-12], [16:0-2-12,0-2-12], [19:0-9-0,0-4-8], [20:0-4-4,0-4-0], [22:0-5-0,0-2-0], [24:0-3-8,0-5-0],
[27:0-10-4,0-7-0], [29:0-2-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.25
0.62
0.89
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.39
-0.73
0.27
(loc)
26-27
26-27
17
l/defl
>999
>705
n/a
L/d
360
240
n/a
PLATES
MT20
MT18H
Weight: 413 lb FT= 10%
GRIP
197/144
197/144
LUMBER
TOP CHORD2x8SP 2400F 2.0E*Except*
T1: 2x6SP 2400F 2.0E
BOT CHORD2x8SP 2400F 2.0E*Except*
B3: 2x6SP 2400F 2.0E
WEBS 2x4SPFStud*Except*
W17: 2x6SP 2400F 2.0E,W8: 2x4SPF 1650F 1.5E
W7,W13,W12,W14,W15: 2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 5-5-12 oc purlins,
except end verticals, and 2-0-0 oc purlins(4-2-4max.): 3-16.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.Except:
6-0-0 oc bracing: 18-19
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)1=1726/0-5-8(min. 0-1-12), 17=1726/0-4-0(min. 0-2-1)
Max Horz1=190(LC 9)
Max Uplift1=-414(LC 11), 17=-627(LC 8)
MaxGrav1=2132(LC 14), 17=2521(LC 14)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-35=-3548/688, 2-35=-3508/705, 2-36=-3577/734, 3-36=-3524/750, 3-37=-4249/968,
4-37=-4253/968, 4-38=-5001/1207, 5-38=-5001/1207, 5-6=-5001/1207, 6-7=-7332/1908,
7-8=-6786/1802, 8-9=-6786/1802, 9-10=-6786/1802, 10-39=-5130/1371,
11-39=-5130/1371, 11-12=-4924/1320, 12-13=-3271/876, 13-14=-3340/890,
14-15=-3340/890, 15-16=-1363/381, 16-17=-2379/576
BOT CHORD 1-34=-719/2911, 33-34=-719/2911, 32-33=-719/2911, 31-32=-684/3020, 30-31=-926/4247,
29-30=-1272/5469, 28-29=-283/1174, 7-27=-89/726, 26-27=-1843/7548,
25-26=-1533/6145, 24-25=-1533/6145, 22-23=-291/1174, 21-22=-252/1020,
19-20=-379/1590, 15-19=-1903/522
WEBS 2-32=-273/148, 3-32=-52/324, 3-31=-563/1963, 4-31=-1425/471, 4-30=-382/1190,
5-30=-419/143, 6-30=-739/296, 6-29=-1657/436, 27-29=-1062/4614, 6-27=-694/2515,
7-26=-1023/226, 9-26=-352/166, 10-26=-209/910, 10-24=-1398/392, 22-24=-620/2657,
12-24=-653/2545, 12-22=-2151/536, 20-22=-663/2826, 12-20=-609/194, 15-20=-617/2375,
16-19=-597/2552
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-2-12 to 4-7-1,Interior(1) 4-7-1 to 7-4-4,Exterior(2) 7-4-4 to 13-6-4zone;cantileverleft and right exposed ; end
verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)All plates areMT20 plates unless otherwiseindicated.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T12
TrussType
HalfHip
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:552014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-N_Y2L6EFaUpx4ffYtIboyu8W78ZHUv?jS5vWhLzWRW2
NOTES
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 1=414, 17=627.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
11)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T13
TrussType
HalfHip
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:552014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-N_Y2L6EFaUpx4ffYtIboyu8Ke8VAUvejS5vWhLzWRW2
Scale=1:78.1
0-2-5
T1
T2
W5
B1
B3
B4
B3
B5
B3
B6
B3
B7
W1 W2
W3 W4
W5
W7
W6 W8 W9 W8
W11
W10
W5
W13
W12
W14
W15
T4T3
B2HW1
1
2
3 4 5 6 7 8 9 10 11 12 13
28 27 26 25 24
23 22 21
20 19 18
17 16
15 14
29
30
31 32 33 34
6x10
8x8 4x8 6x6
4x63x63x4
2x4
8x10
5x6
2x4 2x4
5x6
8x10
2x4
2x4
4x4
1.5x4 4x4 5x12
4x6 4x4
4x4
10x10
4x12
6x10
6x8
4x8
5-6-14
5-6-14
10-10-4
5-3-6
16-6-14
5-8-10
22-3-8
5-8-10
27-6-14
5-3-6
32-10-4
5-3-6
35-3-4
2-5-0
37-8-4
2-5-0
41-3-4
3-7-0
43-7-4
2-4-0
5-6-14
5-6-14
10-10-4
5-3-6
16-6-14
5-8-10
22-3-8
5-8-10
27-6-14
5-3-6
32-10-4
5-3-6
35-3-4
2-5-0
37-8-4
2-5-0
41-3-4
3-7-0
43-7-4
2-4-0
0-5-6
7-5-15
7-8-4
7-5-15
1-0-0
8.0012
PlateOffsets(X,Y): [1:0-1-12,Edge], [2:0-1-12,0-2-0], [3:0-4-9,Edge], [9:0-2-12,0-2-0], [13:0-3-0,0-2-4], [16:0-3-8,0-2-4], [17:0-7-0,0-4-0], [19:0-6-0,0-1-8], [21:0-6-12,0-5-4],
[23:0-3-12,0-4-0], [25:0-3-8,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.99
0.89
0.85
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.35
-0.65
0.36
(loc)
22-23
22-23
14
l/defl
>999
>800
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 288 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x6SPF No.2 *Except*
T1: 2x4SPF No.2
BOT CHORD2x4SPF No.2 *Except*
B3: 2x4SPFStud,B4: 2x6SPF No.2
WEBS 2x4SPF No.2 *Except*
W5,W1,W2,W9,W12,W14,W16: 2x4SPFStud
WEDGE
Left: 2x6SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 2-10-0 oc purlins,
except end verticals, and 2-0-0 oc purlins(3-4-2max.): 3-13.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 13-14, 4-25, 9-19, 10-16
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)1=1729/0-5-8(min. 0-3-2), 14=1729/0-4-0(min. 0-4-0)
Max Horz1=298(LC 9)
Max Uplift1=-376(LC 11), 14=-578(LC 8)
MaxGrav1=2001(LC 14), 14=2550(LC 14)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-29=-3251/616, 29-30=-3215/622, 2-30=-3167/638, 2-3=-3065/654, 3-31=-3450/761,
4-31=-3458/760, 4-32=-4234/962, 5-32=-4234/962, 5-6=-4244/963, 6-7=-4244/963,
7-33=-3960/966, 8-33=-3960/966, 8-9=-3324/835, 9-10=-2157/568, 10-34=-819/264,
11-34=-819/264, 11-12=-819/264, 12-13=-803/261, 13-14=-2496/561
BOT CHORD 1-28=-789/2611, 27-28=-789/2611, 26-27=-789/2611, 25-26=-654/2533, 5-23=-471/210,
22-23=-922/3960, 21-22=-780/3347, 8-21=-1032/308, 10-17=-327/1696, 16-17=-515/2166,
12-16=-348/134
WEBS 2-26=-603/216, 3-26=-73/465, 3-25=-480/1478, 4-25=-1674/538, 23-25=-757/3275,
4-23=-353/1158, 7-23=-111/425, 7-22=-700/257, 8-22=-217/926, 19-21=-587/2555,
9-21=-646/2780, 9-19=-2430/597, 17-19=-579/2521, 9-17=-392/136, 10-16=-2510/569,
13-16=-540/2517
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-2-12 to 4-7-1,Interior(1) 4-7-1 to 10-10-4,Exterior(2) 10-10-4 to 17-0-4zone;cantileverleft and right exposed ;
endverticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
1=376, 14=578.Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T13
TrussType
HalfHip
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:562014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-rB6QYSFtLoxohpEkR?61U5gVOYqPDMusgle3DnzWRW1
NOTES
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
10)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T14
TrussType
Roof Special
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:572014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-JNgpmoGW663eJzpw_jdG1JDhqy9oynn?vPOclDzWRW0
Scale=1:89.2
0-2-5
0-2-5
0-2-5
T2
T3 T4 T5
W13
B1
B3
B4
B5
B6
B5
B7
B5
B8
W1
W2
W3
W5
W4
W6
W7
W8
W9
W10 W11
W13
W12
W11
W14
W16
W15
T1
T6
B2
HW112
3
4
5 6 7
8 9 10 11
12
13 14
29 28 27 26
25 24 23 22
21 20 19
18 17
16 15
30
31
32
33
3435 36
37 383x6
5x6 6x8
5x8 3x6 6x6
4x6
6x10
3x6 3x5
4x6
3x4
2x4 2x4
2x4
6x8
5x6
2x4
4x4
1.5x4 4x10
8x10
4x8
1.5x4
10x10
4x12
6x8
8x8
7-3-14
7-3-14
14-4-4
7-0-6
22-3-8
7-11-4
25-9-3
3-5-11
27-5-4
1-8-1
32-10-4
5-5-0
35-3-4
2-5-0
37-8-4
2-5-0
41-3-4
3-7-0
43-7-4
2-4-0
-1-0-0
1-0-0
7-3-14
7-3-14
14-4-4
7-0-6
22-3-8
7-11-4
25-9-3
3-5-11
27-5-4
1-8-1
32-10-4
5-5-0
35-3-4
2-5-0
37-8-4
2-5-0
41-3-4
3-7-0
43-7-4
2-4-0
0-5-6
9-9-15
8-8-9
10
-0-4
10
-7-1
8-8-9
1-0-0
9-9-15
8.0012
PlateOffsets(X,Y): [2:0-1-12,Edge], [3:0-1-12,0-2-0], [5:0-3-0,0-1-8], [7:0-2-12,0-1-12], [8:0-2-12,0-2-8], [10:0-2-8,0-2-0], [13:0-2-12,0-2-0], [14:0-3-0,0-2-0], [17:0-4-4,0-5-8],
[18:0-2-8,0-2-4], [20:0-6-0,0-1-12], [22:0-4-8,Edge], [24:0-4-0,0-1-12], [25:0-7-4,0-4-8], [27:0-2-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.94
0.94
0.94
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.32
-0.63
0.32
(loc)
22-23
26-27
15
l/defl
>999
>828
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 304 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2 *Except*
T3: 2x4SP 2250F 1.9E,T4: 2x6SPF No.2, T1: 2x4SPF 1650F 1.5E
BOT CHORD2x4SPF No.2 *Except*
B8: 2x4SP 2250F 1.9E
WEBS 2x4SPF No.2 *Except*
W1,W12,W16: 2x4SPFStud
WEDGE
Left: 2x6SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied, except end verticals, and
2-0-0 oc purlins(2-2-0max.): 5-7, 8-14.
BOT CHORD Rigidceiling directly applied or 2-2-0 oc bracing.Except:
1 Row at midpt 6-25, 13-17
WEBS 1 Row at midpt 3-27, 5-27, 6-24, 8-24, 8-22, 10-20
2 Rows at 1/3 pts 14-15
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)15=1728/0-4-0(min. 0-2-4), 2=1804/0-5-8(min. 0-3-6)
Max Horz2=465(LC 9)
Max Uplift15=-610(LC 9), 2=-417(LC 10)
MaxGrav15=2694(LC 21), 2=2158(LC 22)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-30=-3244/564, 30-31=-3110/566, 31-32=-3101/567, 3-32=-2997/589, 3-4=-2818/557,
4-33=-2792/567, 5-33=-2700/590, 5-34=-3264/718, 34-35=-3265/717, 35-36=-3268/717,
6-36=-3269/717, 6-7=-3075/633, 7-8=-3770/790, 8-9=-2824/567, 9-10=-2800/560,
10-37=-1828/389, 11-37=-1828/389, 11-38=-1833/389, 12-38=-1833/389,
12-13=-1833/389, 13-14=-722/219, 14-15=-2631/623
BOT CHORD 2-29=-818/2533, 28-29=-818/2533, 27-28=-818/2533, 6-25=-498/273, 24-25=-892/3259,
23-24=-879/3439, 22-23=-880/3438, 9-22=-595/205, 11-18=-403/135, 17-18=-274/744,
13-17=-2444/636
WEBS 3-29=0/291, 3-27=-860/303, 5-27=-53/403, 25-27=-703/2202, 5-25=-294/1412,
6-24=-551/198, 7-24=-443/2024, 8-24=-1654/329, 8-22=-1031/241, 20-22=-557/2154,
10-22=-602/2455, 10-20=-1660/474, 18-20=-574/2175, 10-18=-868/189, 13-18=-524/2363,
14-17=-654/2617
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)-1-0-0 to 3-4-5,Interior(1) 3-4-5 to 14-4-4,Exterior(2) 14-4-4 to 27-5-4,Interior(1) 27-5-4 to 43-5-8zone;cantilever
left and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber
DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T14
TrussType
Roof Special
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:572014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-JNgpmoGW663eJzpw_jdG1JDhqy9oynn?vPOclDzWRW0
NOTES
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 15=610, 2=417.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
11)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T15
TrussType
Roof Special
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:582014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-nZEBz8H8tPBVx7O7YQ8VZWmvULUehDU9837AIgzWRW?
Scale=1:89.3
0-2-5
0-2-5
0-2-5
T2
T3
T4
T5
W15
B1
B3
B4
B5
B6
B5
B7
B5
B8
W1 W2
W3
W4 W5
W7
W6 W8
W9 W10
W11
W12
W13
W15
W14
W13
W16
W18
W17
T1
B2
HW112
3
4
5
6 7
8
9 10 11 12 13 14
30 29 28 27 26
25
24 23
22
21 20 19
18 17
16 15
31
32
33
34
35 36
37
38
39 4041
3x6
5x6
5x8
4x6
6x10
3x10MT18H 2x4
5x6
6x10
10x10
2x4
2x4
2x4
2x4
6x8
4x6
2x4
4x4
1.5x4
4x4
4x4
4x12
4x4
4x4
1.5x4 4x12
6x8
8x10
8x8
6-1-12
6-1-12
12-0-0
5-10-4
17-10-4
5-10-4
22-3-8
4-5-4
26-7-4
4-3-12
30-11-4
4-4-0
32-10-4
1-11-0
35-3-4
2-5-0
37-8-4
2-5-0
41-3-4
3-7-0
43-7-4
2-4-0
-1-0-0
1-0-0
6-1-12
6-1-12
12-0-0
5-10-4
17-10-4
5-10-4
22-3-3
4-4-15
26-7-4
4-4-0
30-11-4
4-4-0
32-10-4
1-11-0
35-3-4
2-5-0
37-8-4
2-5-0
41-3-4
3-7-0
43-7-4
2-4-0
0-5-6
12
-1-15
6-4-9
12
-4-4
12
-11
-1
6-4-9
1-0-0
12
-1-15
8.0012
PlateOffsets(X,Y): [2:0-1-12,Edge], [3:0-1-12,0-2-0], [5:0-1-12,0-2-0], [6:0-3-0,0-1-8], [7:0-3-4,0-3-4], [8:0-1-0,0-2-0], [9:0-2-12,0-2-8], [11:0-3-0,0-2-8], [13:0-3-0,0-1-8],
[14:Edge,0-3-4], [17:0-5-0,0-5-8], [18:0-2-8,0-2-12], [20:0-6-0,0-1-12], [22:0-4-8,Edge], [24:0-1-8,0-1-12], [25:0-3-8,0-2-12], [27:0-3-0,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.76
0.97
0.97
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.30
-0.60
0.32
(loc)
24
23-24
15
l/defl
>999
>860
n/a
L/d
360
240
n/a
PLATES
MT20
MT18H
Weight: 294 lb FT= 10%
GRIP
197/144
197/144
LUMBER
TOP CHORD2x4SPF No.2 *Except*
T4: 2x6SPF No.2
BOT CHORD2x4SPF No.2 *Except*
B5: 2x4SPFStud
WEBS 2x4SPFStud*Except*
W3,W4,W5,W6,W8,W9,W14,W13: 2x4SPF No.2
WEDGE
Left: 2x6SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 2-5-10 oc purlins,
except end verticals, and 2-0-0 oc purlins(3-1-10max.): 6-7, 9-14.
BOT CHORD Rigidceiling directly applied or 2-2-0 oc bracing.Except:
1 Row at midpt 13-17
WEBS 1 Row at midpt 14-15, 5-27, 8-25, 9-24, 11-20
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)15=1728/0-4-0(min. 0-3-8), 2=1804/0-5-8(min. 0-3-13)
Max Horz2=501(LC 9)
Max Uplift15=-417(LC 11), 2=-441(LC 10)
MaxGrav15=2229(LC 21), 2=2421(LC 22)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-31=-3758/556, 3-31=-3553/574, 3-4=-3295/554, 4-32=-3118/567, 5-32=-2951/583,
5-33=-2669/564, 33-34=-2455/579, 34-35=-2452/580, 6-35=-2374/593, 6-7=-2268/573,
7-36=-2706/630, 36-37=-2845/619, 8-37=-2866/606, 8-38=-3539/686, 9-38=-3623/670,
9-10=-3288/660, 10-39=-3269/656, 11-39=-3269/656, 11-12=-2118/458, 12-40=-2130/460,
40-41=-2130/460, 13-41=-2130/460, 13-14=-881/224, 14-15=-2177/444
BOT CHORD 2-30=-680/2979, 29-30=-680/2979, 28-29=-680/2979, 27-28=-563/2594, 7-25=-232/1189,
24-25=-603/2935, 23-24=-776/3783, 22-23=-777/3781, 10-22=-300/98, 12-18=-363/128,
17-18=-245/910, 13-17=-1983/440
WEBS 3-30=0/253, 3-28=-475/220, 5-28=-67/393, 5-27=-937/323, 6-27=-166/424,
25-27=-422/2025, 6-25=-152/710, 8-25=-1394/405, 8-24=-225/1278, 9-24=-1540/359,
9-22=-1324/202, 20-22=-517/2312, 11-22=-477/2492, 11-20=-1812/440, 18-20=-518/2361,
11-18=-633/131, 13-18=-397/2021, 14-17=-473/2255
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)-1-0-0 to 3-4-5,Interior(1) 3-4-5 to 17-10-4,Exterior(2) 17-10-4 to 22-3-3,Interior(1) 26-7-4 to 30-11-4zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T15
TrussType
Roof Special
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:582014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-nZEBz8H8tPBVx7O7YQ8VZWmvULUehDU9837AIgzWRW?
NOTES
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 15=417, 2=441.
10)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
11)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
12)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T16
TrussType
PiggybackBase
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:592014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-FmnZAUImejJMYHzJ68fk6kI6YlqrQgiINjtjq6zWRW_
Scale=1:93.0
0-2-5
T2
T3
T4
T5
W21
B1
B3
B4
B5
B6
B7
B8
B7
B9
W1 W2
W3
W4 W5
W7
W6
W8
W9
W10
W11 W12 W13
W15
W16
W18
W18
W20
W19T1
B2
1
2
3
4
5 6 7
8
9
10 11
12
13 14
30 29 28 27 26
25 24 23 22
2120 19
18 17
16 15
31
32
33
34
35 36 37 38 39
40 41
42
4x8
8x12MT18H
8x8
4x4
4x12
4x8 3x4
6x8
6x6
3x6 3x5
3x4
6x12 8x10
3x4
2x4
4x4
2x4 4x4
4x4
5x12
6x6
4x6
4x6
4x6
12x18MT18H
7x14MT18H
5x6 6x6
5-11-10
5-11-10
11-7-13
5-8-2
17-3-15
5-8-2
22-3-8
4-11-9
22-9-9
0-6-1
27-9-14
5-0-6
32-10-4
5-0-6
34-5-4
1-7-0
37-8-4
3-3-0
41-3-4
3-7-0
43-7-4
2-4-0
5-11-10
5-11-10
11-7-13
5-8-2
17-3-15
5-8-2
22-3-8
4-11-9
22-9-9
0-6-1
27-9-14
5-0-6
32-10-4
5-0-6
34-5-4
1-7-0
37-8-4
3-3-0
39-5-12
1-9-8
41-3-4
1-9-8
43-7-4
2-4-0
0-5-6
4-0-9
12
-0-0
4-0-9
1-0-0
12
-0-0
8.0012
PlateOffsets(X,Y): [1:0-10-10,0-1-11], [2:0-1-12,0-2-0], [4:0-1-12,0-2-0], [5:0-3-0,0-2-12], [7:0-6-0,0-2-10], [8:0-2-12,0-2-0], [9:0-1-12,0-3-0], [10:0-2-12,0-5-0], [11:0-2-4
,0-1-8], [13:0-2-4,0-1-8], [15:0-1-12,0-2-0], [17:0-3-0,0-3-8], [18:0-5-4,0-3-0], [19:0-2-4,0-1-8], [20:0-7-0,0-2-0], [22:0-9-0,0-6-8], [25:0-2-8,0-2-12],
[27:0-1-8,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.61
0.97
0.97
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.37
-0.70
0.33
(loc)
22-23
22-23
15
l/defl
>999
>746
n/a
L/d
360
240
n/a
PLATES
MT20
MT18H
Weight: 370 lb FT= 10%
GRIP
197/144
197/144
LUMBER
TOP CHORD2x6SPF No.2 *Except*
T4,T5: 2x8SP 2400F 2.0E
BOT CHORD2x4SPF No.2 *Except*
B1,B2: 2x6SPF No.2, B4,B6,B8,B9: 2x6SP 2400F 2.0E
WEBS 2x4SPFStud*Except*
W3,W4,W5,W6,W8,W9,W10,W15,W19: 2x4SPF No.2
W14,W17: 2x4SPF 1650F 1.5E
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-6-1 oc purlins,
except end verticals, and 2-0-0 oc purlins(4-6-11max.): 5-7, 10-14.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except:
9-5-0 oc bracing: 1-30
9-6-13 oc bracing: 28-30
2-2-0 oc bracing: 21-22.
1 Row at midpt 6-25
WEBS 1 Row at midpt 4-27, 7-25, 8-24, 9-23, 10-20
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)15=1736/0-4-0(min. 0-1-12), 1=1736/Mechanical
Max Horz1=426(LC 9)
Max Uplift15=-410(LC 11), 1=-380(LC 10)
MaxGrav15=2077(LC 21), 1=2377(LC 21)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-31=-3990/600, 2-31=-3795/617, 2-3=-3491/577, 3-32=-3322/590, 4-32=-3158/606,
4-33=-2840/576, 33-34=-2630/590, 34-35=-2591/594, 5-35=-2554/605, 5-36=-2448/586,
36-37=-2447/586, 6-37=-2447/586, 6-7=-2481/594, 7-38=-2874/648, 38-39=-2970/636,
8-39=-3170/623, 8-40=-4094/723, 40-41=-4156/706, 9-41=-4256/706, 9-10=-6782/1122,
10-11=-4302/794, 11-42=-4325/794, 12-42=-4325/794, 12-13=-1657/336,
13-14=-1602/328, 14-15=-2026/414
BOT CHORD 1-30=-604/3245, 29-30=-604/3245, 28-29=-604/3245, 27-28=-474/2764, 6-25=-87/307,
24-25=-371/2456, 23-24=-569/3487, 22-23=-969/5634, 9-22=-441/2663, 20-21=-80/422,
19-20=-89/488, 11-18=-376/105, 17-18=-600/3027
WEBS 2-28=-584/238, 4-28=-77/447, 4-27=-995/330, 5-27=-169/488, 25-27=-331/2127,
5-25=-177/682, 7-24=-191/1076, 8-24=-1776/450, 8-23=-223/1350, 9-23=-2601/548,
20-22=-975/5718, 10-22=-385/2260, 10-20=-5390/961, 18-20=-731/4261, 10-18=-342/192,
12-18=-328/2126, 12-17=-2246/422, 14-17=-490/2525
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-0-12 to 4-5-1,Interior(1) 4-5-1 to 17-3-15,Exterior(2) 17-3-15 to 27-1-14,Interior(1) 27-1-14 to 34-5-4zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T16
TrussType
PiggybackBase
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:55:592014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-FmnZAUImejJMYHzJ68fk6kI6YlqrQgiINjtjq6zWRW_
NOTES
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)All plates areMT20 plates unless otherwiseindicated.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8) Refer to girder(s) for truss to trussconnections.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 15=410, 1=380.
10)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
11)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
12)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T17
TrussType
PiggybackBaseGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:002014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-kyLxOpIOP1RDAQXVgrAzfxrG19CT97SSbNcHLYzWRVz
Scale=1:88.7
0-2-5
T2
T3
T2
T5
W16
B1
W1 W2
W3 W4
W5
W6 W7
W8
W7 W9
W10 W11
W12 W13 W14 W15
W16
W17
W16T1T4
B3B2
1
2
3
4
5
6 7
8
9
10
11 12 13 14
27 26 25 24 23 22 21 20 19 18 17 16 15
28
29
30 31
32
33
34
35
4x8
8x8
4x8
3x4
4x12
4x8
4x4
2x4 4x4
4x4
4x4
4x4
4x4
8x8
4x8
4x6
4x6
4x6
4x8
5x12MT18H
5x6
5x6
5x6
5x6
5x6
5x6
5x8
4-8-14
4-8-14
8-11-3
4-2-6
13-1-9
4-2-6
17-3-15
4-2-6
22-9-9
5-5-10
27-10-2
5-0-9
32-10-11
5-0-9
37-11-4
5-0-9
39-10-0
1-10-12
41-8-12
1-10-12
43-7-4
1-10-8
4-8-14
4-8-14
8-11-3
4-2-6
13-1-9
4-2-6
17-3-15
4-2-6
22-9-9
5-5-10
27-10-2
5-0-9
32-10-11
5-0-9
37-11-4
5-0-9
39-10-0
1-10-12
41-8-12
1-10-12
43-7-4
1-10-8
0-5-6
12
-0-0
1-8-9
12
-0-0
8.0012
PlateOffsets(X,Y): [1:0-10-10,0-1-11], [2:0-1-12,0-2-0], [4:0-1-12,0-2-0], [5:0-1-12,0-2-0], [6:0-4-0,0-2-13], [7:0-4-0,0-2-13], [9:0-2-12,0-2-0], [11:0-6-0,0-3-12], [12:0-2-4
,0-2-8], [13:0-1-12,0-2-0], [14:0-2-0,0-2-4], [16:0-2-0,0-2-4], [17:0-1-12,0-2-0], [18:0-2-4,0-2-8], [19:0-3-8,0-2-0], [23:0-1-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.69
0.88
1.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.40
-0.70
0.17
(loc)
18-19
18-19
15
l/defl
>999
>739
n/a
L/d
360
240
n/a
PLATES
MT20
MT18H
Weight: 308 lb FT= 10%
GRIP
197/144
197/144
LUMBER
TOP CHORD2x6SPF No.2 *Except*
T5: 2x6SP 2400F 2.0E
BOT CHORD2x6SPF No.2 *Except*
B3: 2x6SP 2400F 2.0E
WEBS 2x4SPFStud*Except*
W5,W6,W7,W8,W9,W10,W15,W17,W18: 2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 2-6-4 oc purlins,
except end verticals, and 2-0-0 oc purlins(3-4-3max.): 6-7, 11-14.
BOT CHORD Rigidceiling directly applied or 8-8-0 oc bracing.
WEBS 1 Row at midpt 5-23, 6-22, 8-22, 9-21, 11-19
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)15=1645/0-4-0(min. 0-1-14), 1=1730/Mechanical
Max Horz1=393(LC 7)
Max Uplift15=-483(LC 9), 1=-388(LC 8)
MaxGrav15=2231(LC 19), 1=2424(LC 19)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-4085/634, 2-3=-3771/596, 3-4=-3673/617, 4-28=-3329/576, 5-28=-3194/597,
5-29=-2857/576, 29-30=-2705/576, 6-30=-2668/587, 6-7=-2343/561, 7-31=-2720/611,
8-31=-3017/598, 8-32=-3744/688, 9-32=-3931/663, 9-10=-5074/865, 10-33=-5246/846,
11-33=-5339/846, 11-12=-8345/1478, 12-34=-6002/1164, 13-34=-6002/1164,
13-14=-2896/619, 14-15=-2114/466
BOT CHORD 1-27=-614/3351, 26-27=-614/3351, 25-26=-469/3056, 24-25=-334/2657, 23-24=-334/2657,
22-23=-220/2235, 21-22=-309/3129, 20-21=-609/4348, 19-20=-609/4348,
18-19=-1412/8132, 17-18=-1137/6002, 17-35=-592/2896, 16-35=-592/2896
WEBS 2-26=-366/180, 4-26=-66/324, 4-25=-688/233, 5-25=-150/624, 5-23=-971/324,
6-23=-243/981, 6-22=-211/381, 7-22=-210/1206, 8-22=-1494/418, 8-21=-225/1178,
9-21=-1676/415, 9-19=-202/1323, 11-19=-3912/830, 11-18=-1886/330, 12-18=-365/2742,
12-17=-1717/259, 13-17=-654/3725, 13-16=-2081/398, 14-16=-711/3409
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)All plates areMT20 plates unless otherwiseindicated.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8) Refer to girder(s) for truss to trussconnections.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
15=483, 1=388.
Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T17
TrussType
PiggybackBaseGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:002014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-kyLxOpIOP1RDAQXVgrAzfxrG19CT97SSbNcHLYzWRVz
NOTES
10)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
11)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
12)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
13) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 25 lb down and 29 lb up at 40-2-4, and 25 lb down and 29 lb up at
41-8-0 on top chord, and 58 lb up at 40-2-4, and 58 lb up at 41-8-0 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
14)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-6=-60, 6-7=-60, 7-11=-60, 11-14=-60, 1-15=-20
Concentrated Loads(lb)
Vert: 13=29(F) 16=19(F) 34=29(F) 35=19(F)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T18
TrussType
PiggybackBaseGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:002014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-kyLxOpIOP1RDAQXVgrAzfxrCM9BU97oSbNcHLYzWRVz
Scale=1:90.1
0-2-5
W1
T1
T2
T3
T4
B1
B3
B4
B5
B6W2
W3
W4
W3
W5 W3 W6 W7
W8 W9
W10 W11
W12
W13
W15
W14
W16
W18
W17 W19 T5
B2 HW2
1 2 3 4
5
6
7 8
9
10
11
12
13
14
28 27 26 25 24 23 22 21 20 19
18 17
16 15
29 30
31
32
33 34
35
36
37 38
3x6
8x8 8x8
3x6
5x12MT18H 3x4
3x4
10x10
4x6
3x5
6x8
8x8
8x8
10x10
5x6
5x8
2x4
2x4
4x6
4x6
4x6
10x10 5x12MT18H
4x12 6x6
8x10
4x4
2-0-0
2-0-0
3-8-8
1-8-8
7-1-0
3-4-8
10-5-8
3-4-8
15-9-11
5-4-4
21-1-15
5-4-4
26-7-9
5-5-10
30-3-8
3-7-15
35-8-8
5-5-0
39-6-12
3-10-4
43-11-8
4-4-12
2-0-0
2-0-0
3-8-8
1-8-8
7-1-0
3-4-8
10-5-8
3-4-8
15-9-11
5-4-4
21-1-15
5-4-4
26-7-9
5-5-10
30-3-8
3-7-15
35-8-8
5-5-0
39-6-12
3-10-4
43-11-8
4-4-12
44-11-8
1-0-0
4-8-1
12
-0-0
12
-6-13
0-5-6
1-0-0
12
-0-0
8.0012
PlateOffsets(X,Y): [1:Edge,0-3-4], [2:0-3-8,0-3-8], [3:0-2-12,0-2-8], [5:0-2-12,0-4-0], [6:0-2-8,0-2-0], [7:0-7-12,0-2-0], [8:0-4-0,0-2-4], [10:0-2-0,0-2-0], [12:0-1-12,0-2-0],
[13:0-2-10,0-2-15], [15:0-2-0,0-3-4], [17:0-6-8,0-6-0], [18:0-2-12,0-5-0], [20:0-3-4,0-2-0], [21:0-2-8,0-2-0], [22:0-2-12,0-2-0], [25:0-3-0,0-2-4], [26:0-3-8
,0-5-0], [27:0-3-8,0-3-4], [28:0-4-0,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.92
0.94
0.98
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.33
-0.63
0.25
(loc)
22
22-24
13
l/defl
>999
>830
n/a
L/d
360
240
n/a
PLATES
MT20
MT18H
Weight: 332 lb FT= 10%
GRIP
197/144
197/144
LUMBER
TOP CHORD2x4SPF No.2 *Except*
T1,T2: 2x6SP 2400F 2.0E
BOT CHORD2x6SPF No.2 *Except*
B1: 2x6SP 2400F 2.0E,B3: 2x4SPF No.2, B5: 2x4SPFStud
B2: 2x6SPF 1650F 1.5E
WEBS 2x4SPFStud*Except*
W1,W2,W4,W9,W10,W11,W12,W13,W14,W18: 2x4SPF No.2
WEDGE
Right: 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied, except end verticals, and
2-0-0 oc purlins(3-4-2max.): 1-5, 7-8.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except:
8-10-6 oc bracing: 22-24.
1 Row at midpt 9-18
WEBS 1 Row at midpt 1-28, 2-27, 5-22, 6-21, 7-20, 8-20, 10-18
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)28=3120/Mechanical, 13=1932/0-5-8(min. 0-4-2)
Max Horz28=-457(LC 6)
Max Uplift28=-1030(LC 8), 13=-488(LC 9)
MaxGrav28=3957(LC 19), 13=2611(LC 20)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-28=-3884/1004, 1-29=-1648/464, 2-29=-1648/464, 2-3=-2941/765, 3-30=-4323/989,
4-30=-4323/989, 4-5=-4325/991, 5-31=-4414/833, 31-32=-4234/839, 6-32=-4131/851,
6-33=-3266/689, 7-33=-2964/702, 7-8=-2356/583, 8-34=-3616/822, 34-35=-3617/814,
9-35=-3755/804, 9-36=-3629/659, 10-36=-3816/631, 10-11=-4811/784, 11-12=-4988/765,
12-13=-4084/653
BOT CHORD 28-37=-310/405, 27-37=-310/405, 27-38=-583/1648, 26-38=-583/1648, 25-26=-774/2941,
24-25=-1053/5302, 23-24=-1051/5302, 22-23=-1051/5302, 21-22=-575/3564,
20-21=-284/2512, 9-18=-584/262, 17-18=-467/4137, 10-17=-108/1000, 13-15=-416/3255
WEBS 1-27=-1015/4005, 2-27=-3290/748, 2-26=-801/3497, 3-26=-1707/361, 3-25=-359/2211,
4-25=-588/179, 5-25=-1583/176, 5-22=-2294/609, 6-22=-334/1565, 6-21=-1879/550,
7-21=-400/1661, 7-20=-543/260, 8-20=-275/165, 18-20=-163/2231, 8-18=-424/2070,
10-18=-1409/328, 15-17=-395/3217, 12-17=-80/927, 12-15=-1039/180
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T18
TrussType
PiggybackBaseGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:012014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-C8vJb9J0AKZ4oa6iDYhCB9ON5ZXjua2bq1Mqt_zWRVy
NOTES
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9) Refer to girder(s) for truss to trussconnections.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 28=1030, 13=488.
11)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
12)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
13)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
14) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 145 lb down and 140 lb up at 1-4-0, and 145 lb down and 140 lb up at
3-4-0, and 1677 lb down and 380 lb up at 3-8-8 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
15)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-5=-60, 5-7=-60, 7-8=-60, 8-14=-60, 19-28=-20, 17-18=-20, 13-16=-20
Concentrated Loads(lb)
Vert: 26=-1226(B) 37=-133(B) 38=-133(B)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T19
TrussType
PiggybackBaseGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:012014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-C8vJb9J0AKZ4oa6iDYhCB9ONRZYnuaobq1Mqt_zWRVy
Scale:1/8"=1'
0-2-5
W1
T1
T2
T3
T4
B1
B3
B4
B5
B6
W2 W1 W2 W1 W2 W3
W4 W5
W6 W7
W8
W9
W11
W10
W12
W14
W13
W15 W16
W17
T5
B2
1 2 3
4
5
6 7
8
9
10
11 12
13
14
28 27 26 25 24 23 22 21 20
19 18
17 16 15
29 30
31
32 33
34
35
36
3x4
5x6 5x8
5x6 6x12MT18H
3x8
4x8 3x4
3x4
10x12
4x6
3x5 6x16MT18H5x6
5x6
5x6
4x6
4x6
4x6
4x6
4x8 5x6
8x12MT18H
4x4
5x12
4x6
4x8
4-9-9
4-9-9
9-5-7
4-7-13
13-11-8
4-6-1
17-6-11
3-7-4
21-1-15
3-7-4
26-7-9
5-5-10
30-3-8
3-7-15
35-8-8
5-5-0
38-2-0
2-5-8
40-7-8
2-5-8
43-11-8
3-4-0
4-9-9
4-9-9
9-5-7
4-7-13
13-11-8
4-6-1
17-6-11
3-7-4
21-1-15
3-7-4
26-7-9
5-5-10
30-3-8
3-7-15
35-8-8
5-5-0
38-2-0
2-5-8
40-7-8
2-5-8
43-11-8
3-4-0
44-11-8
1-0-0
7-0-1
12
-0-0
12
-6-13
0-5-6
1-0-0
12
-0-0
8.0012
PlateOffsets(X,Y): [1:0-2-4,0-2-0], [3:0-2-12,0-2-0], [4:0-2-12,0-3-8], [5:0-2-12,0-2-0], [6:0-3-12,0-2-0], [7:0-9-8,0-2-8], [9:0-1-8,0-1-8], [10:0-1-12,0-2-0], [12:0-1-8,0-1-12],
[13:0-2-14,0-2-11], [15:0-5-12,0-2-0], [16:0-5-0,0-2-0], [17:0-2-4,0-1-8], [18:0-7-12,0-5-12], [19:0-5-0,0-3-12], [21:0-2-12,0-2-8], [25:0-2-12,0-2-0],
[27:0-2-4,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.90
0.87
1.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.36
-0.70
0.26
(loc)
18-19
18-19
13
l/defl
>999
>743
n/a
L/d
360
240
n/a
PLATES
MT20
MT18H
Weight: 351 lb FT= 10%
GRIP
197/144
197/144
LUMBER
TOP CHORD2x6SP 2400F 2.0E*Except*
T3: 2x4SPF No.2, T4,T5: 2x4SPF 1650F 1.5E
BOT CHORD2x4SPF No.2 *Except*
B1,B2: 2x6SPF No.2, B4: 2x6SPF 1650F 1.5E
B6: 2x8SP 2400F 2.0E
WEBS 2x4SPF No.2 *Except*
W1,W3,W12,W13,W15,W16,W17: 2x4SPFStud
W14: 2x4SPF 1650F 1.5E
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 1-6-9 oc purlins,
except end verticals, and 2-0-0 oc purlins(2-10-4max.): 1-4, 6-7.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except:
6-0-0 oc bracing: 17-18.
1 Row at midpt 8-19
WEBS 1 Row at midpt 1-28, 2-27, 3-26, 4-25, 4-23, 5-22, 7-22,
7-21, 7-19, 9-19
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)28=1937/Mechanical, 13=4477/0-5-8(min. 0-4-10)
Max Horz28=-389(LC 9)
Max Uplift28=-475(LC 8), 13=-1053(LC 9)
MaxGrav28=2589(LC 19), 13=5576(LC 20)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-28=-2539/492, 1-2=-1646/305, 2-29=-2802/527, 3-29=-2802/527, 3-30=-3481/660,
4-30=-3479/660, 4-5=-3633/690, 5-31=-3121/647, 31-32=-2996/650, 6-32=-2933/660,
6-7=-2491/591, 7-33=-4178/898, 33-34=-4181/890, 8-34=-4317/880, 8-35=-4195/736,
9-35=-4381/707, 9-10=-6820/1105, 10-11=-6426/1109, 11-12=-6470/1102,
12-13=-8258/1418
BOT CHORD 27-28=-179/388, 26-27=-270/1646, 25-26=-381/2802, 24-25=-507/3452, 23-24=-507/3452,
22-23=-364/2936, 21-22=-206/2552, 8-19=-583/262, 18-19=-726/5717, 9-18=-405/2608,
16-17=-67/343, 15-16=-1061/6709, 15-36=-1061/6709, 13-36=-1061/6709
WEBS 1-27=-524/2826, 2-27=-2214/481, 2-26=-383/2032, 3-26=-1551/356, 3-25=-256/1616,
4-25=-1236/251, 4-23=-1461/300, 5-23=-225/1314, 5-22=-1217/367, 6-22=-250/1372,
7-22=-342/129, 7-21=-569/98, 19-21=-170/2420, 7-19=-580/2948, 9-19=-2812/584,
16-18=-762/5655, 10-18=0/491, 10-16=-685/9, 12-16=-1909/430, 12-15=-445/2322
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverright exposed ; end verticalright exposed; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T19
TrussType
PiggybackBaseGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:012014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-C8vJb9J0AKZ4oa6iDYhCB9ONRZYnuaobq1Mqt_zWRVy
NOTES
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9) Refer to girder(s) for truss to trussconnections.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 28=475, 13=1053.
11)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
12)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
13)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
14) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 3213 lb down and 586 lb up at 40-7-8, and 217 lb down and 81 lb up
at 42-6-12 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
15)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-4=-60, 4-6=-60, 6-7=-60, 7-14=-60, 20-28=-20, 18-19=-20, 13-17=-20
Concentrated Loads(lb)
Vert: 15=-2652(F) 36=-201(F)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T20
TrussType
PiggybackBase
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:022014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-gKTipVKexehxPkhunGDRkMwb9zyGd4el3h5NQRzWRVx
Scale=1:82.5
0-2-5
W1
T1
T3
T4
T5
B1
B3
B4
W2
W3 W2 W3 W2 W4
W5 W6
W7
W8
W10
W9
W11 W12 W14
W13
T2
T6
B2
1 2
3
4 5
6 7
8
9
10
11
22 21 20 19 18 17 16 15
14 13 12
23 24
2526 27
28
29
30
31
32
3x4
5x6 3x6
5x6 5x10
3x6
3x6 2x4
2x4
6x10
3x4
5x6
4x4
4x4
4x4
4x4
5x8
4x8 4x4
4x4
4x8
4x6
5-11-9
5-11-9
11-9-7
5-9-13
17-5-8
5-8-1
21-1-15
3-8-7
26-7-9
5-5-10
30-3-8
3-7-15
35-3-0
4-11-8
40-6-0
5-3-0
5-11-9
5-11-9
11-9-7
5-9-13
17-5-8
5-8-1
21-1-15
3-8-7
26-7-9
5-5-10
30-3-8
3-7-15
35-3-0
4-11-8
40-6-0
5-3-0
9-4-112
-0-0
1-9-1
1-0-0
12
-0-0
8.0012
PlateOffsets(X,Y): [1:0-2-12,0-2-0], [2:0-1-12,0-1-8], [5:0-5-12,0-1-12], [6:0-3-12,0-2-0], [7:0-7-8,0-2-8], [9:0-1-12,0-2-0], [11:Edge,0-1-12], [13:0-3-8,0-2-0], [14:0-3-12,0-2-0],
[16:0-1-12,0-1-12], [20:0-1-12,0-1-8], [21:0-2-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.71
0.60
0.83
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.18
-0.37
0.10
(loc)
18
18-20
12
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 273 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2 *Except*
T3: 2x6SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPF No.2 *Except*
W1: 2x4SPF 1650F 1.5E,W10,W11,W12,W14,W13: 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-4-13 oc purlins,
except end verticals, and 2-0-0 oc purlins(3-0-3max.): 1-5, 6-7.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.Except:
1 Row at midpt 8-14
WEBS 1 Row at midpt 1-22, 1-21, 2-21, 4-20, 5-18, 5-17, 7-17,
7-16
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)22=1608/Mechanical, 12=1608/Mechanical
Max Horz22=-350(LC 11)
Max Uplift22=-514(LC 8), 12=-302(LC 11)
MaxGrav22=2407(LC 20), 12=2071(LC 21)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-22=-2352/537, 1-23=-1339/284, 2-23=-1339/284, 2-3=-2111/440, 3-4=-2111/440,
4-24=-2342/474, 5-24=-2339/475, 5-6=-2199/519, 6-25=-1801/467, 25-26=-1800/467,
26-27=-1797/467, 7-27=-1796/467, 7-28=-2180/591, 28-29=-2187/581, 8-29=-2320/573,
8-30=-2068/477, 30-31=-2194/454, 9-31=-2368/451, 9-10=-2187/394, 10-32=-2326/379,
11-32=-2423/379, 11-12=-2019/351
BOT CHORD 21-22=-144/349, 20-21=-210/1339, 19-20=-240/2111, 18-19=-240/2111, 17-18=-261/2336,
16-17=-141/1535, 8-14=-527/230, 13-14=-281/1935
WEBS 1-21=-519/2450, 2-21=-1941/502, 2-20=-290/1428, 4-20=-1079/302, 4-18=-158/751,
5-18=-542/180, 5-17=-1405/300, 6-17=-161/808, 7-17=-168/634, 7-16=-335/85,
14-16=-124/1531, 7-14=-310/1165, 9-13=-444/132, 11-13=-250/1932
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 4-2-6,Interior(1) 4-2-6 to 21-1-15,Exterior(2) 21-1-15 to 30-8-3,Interior(1) 30-8-3 to 40-4-4zone;cantilever
right exposed ; end verticalright exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7) Refer to girder(s) for truss to trussconnections.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
22=514, 12=302.Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T20
TrussType
PiggybackBase
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:022014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-gKTipVKexehxPkhunGDRkMwb9zyGd4el3h5NQRzWRVx
NOTES
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
11)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T21
TrussType
PiggybackBase
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:032014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-8X140rLGixqo1uG4LzkgGaTkDMIQMWtuHLrxytzWRVw
Scale=1:85.4
0-3-15
W1
T1 T3
T4
B1
B3
B4
W2
W3
W2
W3
W4
W3 W5 W6
W8
W7
W9 W10 W12
W11
T2
T5
B2
1 2 3 4 5 6
7
8
9
10
20 19 18 17 16 15 14
13 12 11
21 22 23 2425
26
27
28
3x4
5x6 4x8 8x8
3x6
3x6 2x4
2x4
6x10
3x4
5x6
4x6
4x4
4x4
8x8
3x10 4x6
4x4
4x6
4x6
7-1-9
7-1-9
14-1-7
6-11-13
20-11-8
6-10-1
21-1-15
0-2-7
26-7-9
5-5-10
30-3-8
3-7-15
35-3-0
4-11-8
40-6-0
5-3-0
7-1-9
7-1-9
14-1-7
6-11-13
20-11-8
6-10-1
21-1-15
0-2-7
26-7-9
5-5-10
30-3-8
3-7-15
35-3-0
4-11-8
40-6-0
5-3-0
11
-8-1
12
-0-0
1-9-1
1-0-0
12
-0-0
8.0012
PlateOffsets(X,Y): [1:0-3-0,0-2-0], [5:0-3-7,Edge], [6:0-6-8,0-1-12], [8:0-1-12,0-2-0], [10:Edge,0-1-12], [12:0-2-8,0-2-0], [13:0-3-0,0-2-4], [16:0-2-4,0-1-8], [18:0-1-12,0-2-0],
[19:0-3-0,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.88
0.54
0.83
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.15
-0.31
0.09
(loc)
16-18
16-18
11
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 292 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x6SPF No.2 *Except*
T3: 2x10SP 2400F 2.0E,T4,T5: 2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPF No.2 *Except*
W1: 2x4SPF 1650F 1.5E,W8,W9,W10,W12,W11: 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-6-12 oc purlins,
except end verticals, and 2-0-0 oc purlins(4-9-13max.): 1-6.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.Except:
1 Row at midpt 7-13
WEBS 1 Row at midpt 1-19, 2-18, 3-18, 3-16, 5-16, 6-15
2 Rows at 1/3 pts 1-20, 2-19
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)20=1608/Mechanical, 11=1608/Mechanical
Max Horz20=-416(LC 11)
Max Uplift20=-483(LC 10), 11=-286(LC 11)
MaxGrav20=2447(LC 14), 11=1923(LC 15)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-20=-2385/511, 1-21=-1271/258, 2-21=-1271/258, 2-22=-1893/404, 3-22=-1893/404,
3-23=-2019/446, 4-23=-2019/446, 4-5=-2020/448, 5-24=-2045/457, 24-25=-2042/457,
6-25=-2031/459, 6-7=-2175/540, 7-26=-2146/436, 26-27=-2176/425, 8-27=-2232/411,
8-9=-2004/358, 9-28=-2142/342, 10-28=-2239/342, 10-11=-1872/322
BOT CHORD 19-20=-73/416, 18-19=-115/1271, 17-18=-132/1893, 16-17=-132/1893, 15-16=-109/1648,
7-13=-467/214, 12-13=-251/1783
WEBS 1-19=-490/2403, 2-19=-1893/495, 2-18=-278/1183, 3-18=-870/302, 3-16=-139/373,
5-16=-847/234, 6-16=-144/851, 6-15=-367/76, 13-15=-93/1648, 6-13=-292/1087,
8-12=-399/123, 10-12=-218/1774
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 4-2-6,Interior(1) 4-2-6 to 26-7-9,Exterior(2) 26-7-9 to 30-8-3zone;cantileverright exposed ; end vertical
right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7) Refer to girder(s) for truss to trussconnections.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
20=483, 11=286.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T21
TrussType
PiggybackBase
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:032014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-8X140rLGixqo1uG4LzkgGaTkDMIQMWtuHLrxytzWRVw
NOTES
11)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T22
TrussType
Roof Special
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:032014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-8X140rLGixqo1uG4LzkgGaTkaMEbMUkuHLrxytzWRVw
Scale=1:86.3
0-2-5
W1
T1
T3
T4
B1
B3
B4
W2
W3
W2
W3
W2
W3 W2 W3
W4W5
W7
W6
W8 W9 W11
W10
T2
T5
B2
1 2 3 4 5 6 7
8
9
10
11
22 21 20 19 18 1716 15
14 13 12
23 24 25 26 27
28
29
3x4
5x6 3x6 5x8
8x8
3x6
3x6 2x4
2x4
6x8
2x4
5x6
4x4
4x8
1.5x4 4x4
4x4 4x6
4x6
4x4
4x6
4x6
6-6-10
6-6-10
12-11-8
6-4-14
19-4-6
6-4-14
25-11-0
6-6-10
26-6-11
0-7-10
30-3-8
3-8-13
35-3-0
4-11-8
40-6-0
5-3-0
6-6-10
6-6-10
12-11-8
6-4-14
19-4-6
6-4-14
25-11-0
6-6-10
26-6-11
0-7-10
30-3-8
3-8-13
35-3-0
4-11-8
40-6-0
5-3-0
11
-5-3
12
-0-9
1-9-1
1-0-0
11
-5-3
8.0012
PlateOffsets(X,Y): [1:0-2-12,0-2-0], [2:0-2-0,0-1-8], [6:0-5-4,0-2-8], [7:0-1-8,0-2-8], [9:0-1-12,0-2-0], [13:0-2-12,0-2-0], [14:0-2-12,0-2-4], [17:0-2-4,0-2-0], [20:0-3-0,0-2-0],
[21:0-2-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.86
0.79
0.97
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.21
-0.43
0.09
(loc)
17-18
17-18
12
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 288 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2 *Except*
T3: 2x6SPF No.2, T2: 2x4SPF 1650F 1.5E
BOT CHORD2x4SPF No.2
WEBS 2x4SPF No.2 *Except*
W1: 2x4SPF 2100F 1.8E,W7,W8,W9,W11,W10: 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-4-1 oc purlins,
except end verticals, and 2-0-0 oc purlins(2-10-4max.): 1-6.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except:
6-0-0 oc bracing: 14-15.
1 Row at midpt 8-14
WEBS 1 Row at midpt 1-21, 2-20, 3-20, 5-20, 5-18, 7-16
2 Rows at 1/3 pts 1-22, 2-21, 6-17
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)22=1608/Mechanical, 12=1608/Mechanical
Max Horz22=-413(LC 11)
Max Uplift22=-606(LC 8), 12=-298(LC 8)
MaxGrav22=2450(LC 18), 12=1733(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-22=-2391/631, 1-23=-1205/303, 2-23=-1205/303, 2-24=-1840/476, 3-24=-1840/476,
3-25=-1840/476, 4-25=-1840/476, 4-5=-1840/476, 5-26=-2084/546, 26-27=-2082/546,
6-27=-2081/546, 6-7=-2070/583, 7-8=-2128/564, 8-28=-2100/480, 28-29=-2139/477,
9-29=-2195/454, 9-10=-1966/389, 10-11=-2052/373, 11-12=-1683/318
BOT CHORD 21-22=-82/412, 20-21=-121/1205, 19-20=-238/2081, 18-19=-238/2081, 17-18=-171/1734,
16-17=-146/1627, 8-14=-442/222, 13-14=-237/1671
WEBS 1-21=-601/2392, 2-21=-1936/593, 2-20=-348/1274, 3-20=-567/246, 5-20=-484/165,
5-18=-438/183, 6-18=-136/687, 6-17=-2047/553, 7-17=-419/1831, 14-16=-144/1657,
7-14=-292/907, 9-13=-373/129, 11-13=-241/1692
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 4-2-6,Interior(1) 4-2-6 to 26-7-4,Exterior(2) 26-7-4 to 30-7-13zone;cantileverright exposed ; end vertical
right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7) Refer to girder(s) for truss to trussconnections.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
22=606, 12=298.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T22
TrussType
Roof Special
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:042014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-cjbSEBLvTFyff2rGvhFvpn0vKmaq5x_1W?aUUJzWRVv
NOTES
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
11)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T23
TrussType
Roof SpecialGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:042014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-cjbSEBLvTFyff2rGvhFvpn0v_mb85xr1W?aUUJzWRVv
Scale=1:99.0
0-2-5
W1
T1
T3
T4
B1
B3
B4
B5
B6
W2 W1 W2 W1 W2 W1 W2 W1
W2
W3
W4 W5
W7
W6
W8
W10
W9
W11
W12
W13
T2
T5
B2
1 2 3 4
5
6 7
8
9
10
11
12 13
14
15
29 28 27 2625 24 23 22 21
20 19
18 17 16
30
31
32
3x4
6x6 4x8
3x6
4x8 3x4
2x4
10x10
4x6
3x5 6x12MT18H6x6
5x6
5x6
4x6
4x6
4x4
4x8
2x4
8x8
2x4
6x10
6x12
8x10
4x4
5x12
4x6
4x8
4-7-9
4-7-9
9-1-6
4-5-13
13-7-3
4-5-13
18-1-0
4-5-13
22-5-0
4-4-1
26-6-11
4-1-10
30-3-8
3-8-13
35-8-8
5-5-0
38-2-0
2-5-8
40-7-8
2-5-8
43-11-8
3-4-0
4-7-9
4-7-9
9-1-6
4-5-13
13-7-3
4-5-13
18-1-0
4-5-13
22-5-0
4-4-1
26-6-11
4-1-10
30-3-8
3-8-13
35-8-8
5-5-0
38-2-0
2-5-8
40-7-8
2-5-8
43-11-8
3-4-0
44-11-8
1-0-0
9-1-312
-0-9
12
-7-7
0-5-6
1-0-0
9-1-3
8.0012
PlateOffsets(X,Y): [1:0-2-12,0-2-8], [2:0-3-0,0-2-4], [3:0-2-12,0-2-0], [7:0-2-12,0-4-0], [10:0-1-8,0-1-12], [11:0-1-12,0-2-0], [13:0-1-12,0-1-12], [14:0-2-2,0-3-3], [16:0-5-12
,0-2-0], [17:0-5-8,0-2-4], [19:0-6-4,0-7-0], [20:0-3-4,0-4-8], [22:0-3-4,0-3-4], [26:0-2-12,0-2-0], [27:0-3-0,0-2-4], [28:0-2-12,0-2-8], [29:0-2-4,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.88
0.77
0.98
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.31
-0.64
0.22
(loc)
23
23
14
l/defl
>999
>817
n/a
L/d
360
240
n/a
PLATES
MT20
MT18H
Weight: 351 lb FT= 10%
GRIP
197/144
197/144
LUMBER
TOP CHORD2x6SPF No.2 *Except*
T4: 2x4SPF No.2, T5: 2x4SPF 1650F 1.5E
BOT CHORD2x4SPF No.2 *Except*
B1,B2: 2x6SPF No.2, B4: 2x6SPF 1650F 1.5E
B6: 2x8SP 2400F 2.0E
WEBS 2x4SPF No.2 *Except*
W7,W8,W9,W11,W12,W13: 2x4SPFStud
W10: 2x4SPF 1650F 1.5E
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 1-9-11 oc purlins,
except end verticals, and 2-0-0 oc purlins(3-9-11max.): 1-7.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except:
6-0-0 oc bracing: 18-19.
1 Row at midpt 9-20
WEBS 1 Row at midpt 2-28, 3-27, 4-26, 6-24, 7-24, 7-22, 8-20,
10-20
2 Rows at 1/3 pts 1-29
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)29=1939/Mechanical, 14=4502/0-5-8(min. 0-4-3)
Max Horz29=-535(LC 6)
Max Uplift29=-607(LC 6), 14=-1058(LC 9)
MaxGrav29=2785(LC 17), 14=5021(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-29=-2737/601, 1-2=-1311/333, 2-3=-2270/513, 3-4=-2916/639, 4-30=-3242/710,
5-30=-3242/710, 5-6=-3242/710, 6-7=-3248/712, 7-8=-2772/700, 8-9=-3578/905,
9-31=-3519/802, 10-31=-3654/786, 10-11=-5783/1131, 11-12=-5568/1120,
12-13=-5609/1113, 13-14=-7371/1427
BOT CHORD 28-29=-232/443, 27-28=-264/1311, 26-27=-277/2270, 25-26=-403/2916, 24-25=-403/2916,
23-24=-485/3199, 22-23=-484/3200, 9-20=-462/248, 19-20=-802/4842, 10-19=-405/2382,
17-18=-70/291, 16-17=-1085/5984, 16-32=-1085/5984, 14-32=-1085/5984
WEBS 1-28=-616/2831, 2-28=-2425/627, 2-27=-446/2082, 3-27=-1759/433, 3-26=-295/1402,
4-26=-1154/306, 4-24=-197/854, 6-24=-616/208, 7-24=-500/132, 7-22=-2142/499,
8-22=-346/1409, 20-22=-240/2213, 8-20=-570/2452, 10-20=-2385/583, 17-19=-820/4908,
11-19=0/275, 11-17=-411/42, 13-17=-1822/428, 13-16=-451/2219
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates areMT20 plates unless otherwiseindicated.Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T23
TrussType
Roof SpecialGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:042014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-cjbSEBLvTFyff2rGvhFvpn0v_mb85xr1W?aUUJzWRVv
NOTES
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9) Refer to girder(s) for truss to trussconnections.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 29=607, 14=1058.
11)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
12)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
13)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
14) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 3067 lb down and 583 lb up at 40-7-8, and 217 lb down and 81 lb up
at 42-6-12 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
15)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-7=-60, 7-8=-60, 8-15=-60, 21-29=-20, 19-20=-20, 14-18=-20
Concentrated Loads(lb)
Vert: 16=-2679(B) 32=-201(B)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T24
TrussType
Roof Special
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:052014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-4v9qRXMXDZ4WGCQTSOm8M?Y3GAvoqOjBlfK20mzWRVu
Scale=1:87.8
0-2-5
W1
T1
T3
T4
B1
B3
B4
B5
B6
W2 W1 W2 W1 W2 W3
W4
W5
W7
W6
W8
W10
W9 W11
T2
T5
B2
1 2 3
4
5
6
7
8
9
10
11
12
23 22 21 20 19 18 17
16 15
14 13
24 25
26
27
28
29
30
3x4
5x6 4x8
5x8
3x6
3x10MT18H 2x4
2x4
8x10
4x6
2x4
5x8
5x6
4x6
4x4
4x4
4x4
5x10
6x8 4x10
5x12
4x4
6-5-7
6-5-7
12-9-2
6-3-11
18-11-0
6-1-15
26-6-11
7-7-10
30-3-8
3-8-13
35-8-8
5-5-0
39-8-4
3-11-12
43-11-8
4-3-4
6-5-7
6-5-7
12-9-2
6-3-11
18-11-0
6-1-15
26-6-11
7-7-10
30-3-8
3-8-13
35-8-8
5-5-0
39-8-4
3-11-12
43-11-8
4-3-4
44-11-8
1-0-0
6-9-3
12
-0-9
12
-7-7
0-5-6
1-0-0
6-9-3
8.0012
PlateOffsets(X,Y): [1:0-2-4,0-2-4], [5:0-2-12,0-3-8], [6:0-7-4,0-2-8], [8:0-2-12,0-2-0], [10:0-1-12,0-2-0], [11:0-0-9,Edge], [13:0-3-8,0-2-0], [15:0-7-8,0-4-4], [16:0-4-0,Edge],
[18:0-1-12,0-3-0], [21:0-1-12,0-1-8], [22:0-2-4,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.91
0.87
1.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.26
-0.65
0.23
(loc)
19
18-19
11
l/defl
>999
>808
n/a
L/d
360
240
n/a
PLATES
MT20
MT18H
Weight: 259 lb FT= 10%
GRIP
197/144
197/144
LUMBER
TOP CHORD2x6SPF No.2 *Except*
T4,T5: 2x4SPF No.2
BOT CHORD2x4SPF No.2 *Except*
B5: 2x4SPFStud
WEBS 2x4SPFStud*Except*
W2,W4,W5,W6: 2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-0-8 oc purlins,
except end verticals, and 2-0-0 oc purlins(3-6-15max.): 1-5.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.Except:
1 Row at midpt 7-16
WEBS 1 Row at midpt 1-23, 2-22
2 Rows at 1/3 pts 5-18
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)23=1742/Mechanical, 11=1818/0-5-8(min. 0-3-1)
Max Horz23=-379(LC 11)
Max Uplift23=-462(LC 10), 11=-431(LC 11)
MaxGrav23=2406(LC 19), 11=1961(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-23=-2348/488, 1-24=-2023/398, 2-24=-2023/398, 2-25=-3110/633, 3-25=-3110/633,
3-4=-3272/725, 4-5=-3273/725, 5-26=-2172/504, 26-27=-2025/508, 6-27=-1935/529,
6-7=-2582/696, 7-28=-2468/605, 28-29=-2522/594, 8-29=-2657/590, 8-9=-3291/659,
9-10=-3418/640, 10-30=-2836/553, 11-30=-2960/542
BOT CHORD 22-23=-186/379, 21-22=-262/2023, 20-21=-497/3110, 19-20=-497/3110, 18-19=-585/3271,
7-16=-473/240, 15-16=-410/2821, 8-15=-74/663, 11-13=-360/2320
WEBS 1-22=-564/2859, 2-22=-1901/473, 2-21=-335/1548, 3-21=-982/296, 3-19=-189/892,
5-19=-493/209, 5-18=-2256/550, 6-18=-246/1130, 16-18=-139/1708, 6-16=-383/1512,
8-16=-888/301, 13-15=-348/2330, 10-15=-47/522, 10-13=-618/145
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 4-6-8,Interior(1) 4-6-8 to 26-6-11,Exterior(2) 26-6-11 to 30-11-7zone;cantileverright exposed ; end
verticalright exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9) Refer to girder(s) for truss to trussconnections.
Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T24
TrussType
Roof Special
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:052014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-4v9qRXMXDZ4WGCQTSOm8M?Y3GAvoqOjBlfK20mzWRVu
NOTES
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 23=462, 11=431.
11)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
12)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
13)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T25
TrussType
Roof Special
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:062014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-Y6iCetN9_sCNuL?f06HNuC5DpaFiZueK_J3bZCzWRVt
Scale=1:84.9
0-2-5
W1
T1
T2 T3
B1
W2 W1 W2 W1 W2 W1 W2 W3
W4 W5
W6 W7 W8
W9
W10 W11
T4
B3B2
1 2 3 4
5
6
7
8
9
10
11
12
23 22 21 20 19 18 17 16 15 14 13
24 25
26 27
28
3x4
5x6 8x8
5x6
3x6
5x85x6
4x6
5x8
2x4 4x4
4x4
2x4
4x6
4x6
5x8
4x4
4x4
4x4
2x4
4x8
5x6
4-0-0
4-0-0
7-10-4
3-10-4
11-8-8
3-10-4
15-5-0
3-8-8
20-11-14
5-6-13
26-6-11
5-6-13
32-3-2
5-8-7
37-11-9
5-8-7
43-11-8
5-11-15
4-0-0
4-0-0
7-10-4
3-10-4
11-8-8
3-10-4
15-5-0
3-8-8
20-11-14
5-6-13
26-6-11
5-6-13
32-3-2
5-8-7
37-11-9
5-8-7
43-11-8
5-11-15
44-11-8
1-0-0
4-5-3
12
-0-9
12
-7-7
0-5-6
4-5-3
8.0012
PlateOffsets(X,Y): [1:0-2-8,0-2-4], [2:0-2-4,0-2-0], [4:0-1-12,0-2-0], [5:0-2-12,0-4-0], [6:0-2-4,0-2-0], [7:0-2-12,0-1-8], [8:0-1-12,0-2-0], [10:0-1-12,0-2-0], [11:0-2-3,0-2-4],
[17:0-2-8,0-2-0], [20:0-1-12,0-2-0], [21:0-2-12,0-2-8], [22:0-1-12,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.99
0.89
0.83
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.27
-0.63
0.15
(loc)
17-18
17-18
11
l/defl
>999
>832
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 285 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x6SP 2400F 2.0E*Except*
T3,T4: 2x4SPF No.2
BOT CHORD2x6SPF No.2
WEBS 2x4SPF No.2 *Except*
W1,W3,W4,W10,W11: 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-0-7 oc purlins,
except end verticals, and 2-0-0 oc purlins(4-11-5max.): 1-5.
BOT CHORD Rigidceiling directly applied or 7-4-1 oc bracing.
WEBS 1 Row at midpt 5-17, 6-16, 7-16, 8-16
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)23=1742/Mechanical, 11=1818/0-5-8(min. 0-3-1)
Max Horz23=-455(LC 8)
Max Uplift23=-446(LC 10), 11=-444(LC 11)
MaxGrav23=2227(LC 19), 11=1961(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-23=-2179/464, 1-2=-1929/436, 2-24=-3307/736, 24-25=-3307/736, 3-25=-3307/736,
3-4=-3307/736, 4-5=-4202/955, 5-6=-3504/757, 6-26=-2272/564, 7-26=-2058/592,
7-27=-2071/618, 8-27=-2153/590, 8-9=-2459/596, 9-10=-2562/567, 10-28=-2871/584,
11-28=-2992/568
BOT CHORD 22-23=-306/411, 21-22=-402/1929, 20-21=-919/4196, 19-20=-1018/4687,
18-19=-1018/4687, 17-18=-1016/4689, 16-17=-505/2810, 15-16=-289/2046,
14-15=-289/2046, 13-14=-383/2362, 11-13=-383/2362
WEBS 1-22=-559/2746, 2-22=-1898/440, 2-21=-430/1979, 3-21=-436/144, 4-21=-1585/312,
4-20=-99/929, 5-20=-1131/178, 5-17=-2619/631, 6-17=-315/1665, 6-16=-1873/542,
7-16=-523/1921, 8-16=-720/312, 8-14=-64/377, 10-14=-388/216
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 4-6-8,Interior(1) 4-6-8 to 26-6-11,Exterior(2) 26-6-11 to 30-11-7zone;cantileverleft and right exposed ;
endverticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8) Refer to girder(s) for truss to trussconnections.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
23=446, 11=444.Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T25
TrussType
Roof Special
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:062014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-Y6iCetN9_sCNuL?f06HNuC5DpaFiZueK_J3bZCzWRVt
NOTES
10)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
11)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
12)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T26
TrussType
ROOF SPECIALGIRDER
Qty
1
Ply
2
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:072014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-1IGbsDOnlAKEWVarapocRQeaB_dPIKTUCzp85ezWRVs
Scale=1:88.8
0-2-5W1T1
T3 T4
B1W2W3W4W3 W3 W4
W5
W6
W7
W8
W9 W10
W11 W12
W13
W14 W15
W16 W17
W18 W19
T2
T5
B3B2
1 2 3 4
5
6
7
8
9
10
11
12
13
14
15
16
30 29 28 27 26 25 24 23 22 21 20 19 18 17
31
32
33
34
35
3x4
6x6
4x8
5x6
3x6
4x84x6
4x6
4x10
3x6 4x8
2x4 4x6
8x12MT18H
5x6
4x6
4x6
4x4
4x6
4x4
4x8
4x4
4x4
4x4
4x4
4x4
2x4
4x8
4x6
3-1-8
3-1-8
6-1-4
2-11-12
9-1-0
2-11-12
11-11-0
2-10-0
13-11-0
2-0-0
17-7-8
3-8-8
21-4-0
3-8-8
26-6-11
5-2-11
30-9-4
4-2-9
34-11-14
4-2-9
39-2-7
4-2-9
43-11-8
4-9-1
3-1-8
3-1-8
6-1-4
2-11-12
9-1-0
2-11-12
11-11-0
2-10-0
13-11-0
2-0-0
17-7-8
3-8-8
21-4-0
3-8-8
26-6-11
5-2-11
30-9-4
4-2-9
34-11-14
4-2-9
39-2-7
4-2-9
43-11-8
4-9-1
44-11-8
1-0-0
2-1-3
12
-0-9
12
-7-7
0-5-6 2-1-3
8.0012
PlateOffsets(X,Y): [2:0-2-12,0-2-0], [5:0-9-4,0-3-8], [6:0-2-0,0-2-0], [8:0-1-0,0-2-0], [9:0-1-0,0-2-0], [11:0-1-12,0-2-0], [12:0-1-12,0-2-0], [14:0-1-12,0-2-0], [26:0-2-4,0-2-0],
[28:0-3-8,0-2-0], [29:0-2-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.25
0.73
0.86
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.32
-0.70
0.10
(loc)
25
25
15
l/defl
>999
>750
n/a
L/d
360
240
n/a
PLATES
MT20
MT18H
Weight: 629 lb FT= 10%
GRIP
197/144
197/144
LUMBER
TOP CHORD2x6SP 2400F 2.0E*Except*
T1: 2x8SP 2400F 2.0E,T4,T5: 2x4SPF No.2
BOT CHORD2x6SPF No.2 *Except*
B1: 2x6SP 2400F 2.0E
WEBS 2x4SPFStud*Except*
W1: 2x6SP 2400F 2.0E,W5: 2x8SP 2400F 2.0E
W11,W12,W13,W14,W15: 2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins(6-0-0max.): 1-5.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)30=1968/Mechanical, 15=2030/0-5-8(min. 0-1-12)
Max Horz30=-412(LC 6)
Max Uplift30=-540(LC 8), 15=-537(LC 9)
MaxGrav30=2287(LC 17), 15=2211(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-30=-2148/527, 1-31=-3663/904, 2-31=-3663/904, 2-3=-6883/1722, 3-4=-6883/1722,
4-5=-11559/2693, 5-6=-8905/2043, 6-7=-5790/1340, 7-32=-5658/1344, 8-32=-5633/1354,
8-9=-4236/1077, 9-33=-2650/734, 33-34=-2514/743, 10-34=-2496/761, 10-11=-2557/797,
11-35=-2746/778, 12-35=-2849/767, 12-13=-3068/760, 13-14=-3144/739,
14-15=-3420/744
BOT CHORD 29-30=-358/372, 28-29=-974/3663, 27-28=-2430/9781, 26-27=-2430/9781,
25-26=-2706/11315, 24-25=-1732/7346, 23-24=-1732/7346, 22-23=-1064/4708,
21-22=-740/3462, 20-21=-399/2305, 19-20=-399/2305, 18-19=-468/2553,
17-18=-523/2717, 15-17=-523/2717
WEBS 1-29=-910/3742, 2-29=-1812/485, 2-28=-924/3845, 3-28=-451/127, 4-28=-3275/721,
4-26=-366/1976, 5-26=-1319/290, 5-25=-5179/1272, 6-25=-845/3646, 6-23=-3448/873,
8-23=-540/2332, 8-22=-2255/588, 9-22=-624/2472, 9-21=-2515/748, 10-21=-726/2513,
11-21=-706/299, 11-19=-133/399, 12-19=-432/222, 12-18=-49/277
NOTES
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x6- 2 rowsstaggered at 0-9-0 oc, 2x8- 2 rowsstaggered at 0-9-0 oc, 2x4- 1 row at 0-9-0 oc.
Bottomchordsconnected as follows: 2x6- 2 rowsstaggered at 0-9-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x8- 2 rowsstaggered at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3) Unbalancedroofliveloads have been considered for this design.
4)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T26
TrussType
ROOF SPECIALGIRDER
Qty
1
Ply
2
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:072014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-1IGbsDOnlAKEWVarapocRQeaB_dPIKTUCzp85ezWRVs
NOTES
6) Unbalancedsnowloads have been considered for this design.
7)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs non-concurrentwith otherliveloads.
8)Provide adequate drainage to preventwater ponding.
9)All plates areMT20 plates unless otherwiseindicated.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11) Refer to girder(s) for truss to trussconnections.
12)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 30=540, 15=537.
13)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
14)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
15)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
16) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 523 lb down and 192 lb up at 21-4-0 on bottomchord.The
design/selection of suchconnection device(s)is the responsibility of others.
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-5=-60, 5-10=-60, 10-16=-60, 15-30=-20
Concentrated Loads(lb)
Vert: 22=-444(F)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T27
TrussType
Common
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:072014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-1IGbsDOnlAKEWVarapocRQeXm_fGITwUCzp85ezWRVs
Scale=1:72.3
T1
T2
B1
W3 W4
W5
W6
W1 W2
T3
B2
1
2
3
4
5
6 7
11 10 9 8
12
13
14
15
16
17
4x4
3x5
3x4 3x63x8
3x4
3x4
1.5x4
5x6
4x4
5-1-15
5-1-15
14-11-5
9-9-6
22-6-12
7-7-7
5-1-15
5-1-15
10-10-6
5-8-7
16-6-13
5-8-7
22-6-12
5-11-15
23-6-12
1-0-0
8-7-5
12
-0-9
12
-7-7
0-5-6
8.0012
PlateOffsets(X,Y): [1:0-3-0,0-1-8], [3:0-1-12,0-1-8], [6:0-1-3,0-1-13]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.40
0.61
0.32
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.18
-0.47
0.03
(loc)
8-10
8-10
6
l/defl
>999
>569
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 117 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPF No.2 *Except*
W6: 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 4-8-9 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-10, 3-10, 1-11
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)11=885/Mechanical, 6=963/0-5-8(min. 0-1-10)
Max Horz11=-537(LC 8)
Max Uplift11=-252(LC 11), 6=-261(LC 11)
MaxGrav11=954(LC 2), 6=1040(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-12=-487/242, 12-13=-413/243, 13-14=-402/255, 2-14=-377/267, 2-15=-349/270,
15-16=-402/256, 3-16=-516/254, 3-4=-1024/352, 4-5=-1214/323, 5-17=-1273/266,
6-17=-1371/243, 1-11=-926/276
BOT CHORD 10-11=-246/451, 9-10=0/679, 8-9=0/679, 6-8=-85/1035
WEBS 3-10=-596/348, 3-8=-166/533, 5-8=-295/254, 1-10=-190/640
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 5-1-15,Exterior(2) 5-1-15 to 8-1-15zone;cantileverleft and right exposed ;
endverticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7) Refer to girder(s) for truss to trussconnections.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
11=252, 6=261.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T28
TrussType
Common
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:072014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-1IGbsDOnlAKEWVarapocRQeXQ_fHIT1UCzp85ezWRVs
Scale=1:72.3
T1
T2
B1
W3 W4
W5
W6
W1 W2
T3
B2
1
2
3
4
5
6 7
11 10 9 8
12
13
14 15
16
17
4x4
3x5
3x4 3x63x8
3x4
3x4
1.5x4
5x6
4x4
5-3-11
5-3-11
15-0-8
9-8-13
22-8-8
7-8-0
5-3-11
5-3-11
11-0-2
5-8-7
16-8-9
5-8-7
22-8-8
5-11-15
23-8-8
1-0-0
8-6-2
12
-0-9
12
-7-7
0-5-6
8.0012
PlateOffsets(X,Y): [1:0-3-0,0-1-8], [3:0-1-12,0-1-8], [6:0-1-3,0-1-13]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.42
0.61
0.31
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.18
-0.46
0.03
(loc)
8-10
8-10
6
l/defl
>999
>587
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 117 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPF No.2 *Except*
W6: 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 4-8-6 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-10, 3-10, 1-11
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)11=891/0-3-8(min. 0-1-8), 6=969/0-5-8(min. 0-1-10)
Max Horz11=-536(LC 8)
Max Uplift11=-251(LC 11), 6=-263(LC 11)
MaxGrav11=960(LC 2), 6=1046(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-12=-502/241, 12-13=-422/250, 13-14=-413/254, 2-14=-391/267, 2-15=-362/272,
15-16=-413/258, 3-16=-527/255, 3-4=-1030/353, 4-5=-1221/324, 5-17=-1282/270,
6-17=-1381/247, 1-11=-930/276
BOT CHORD 10-11=-247/451, 9-10=0/688, 8-9=0/688, 6-8=-87/1043
WEBS 3-10=-596/348, 3-8=-164/529, 5-8=-294/253, 1-10=-186/638
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 5-3-11,Exterior(2) 5-3-11 to 8-3-11zone;cantileverleft and right exposed ;
endverticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
11=251, 6=263.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T29
TrussType
Hip
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:082014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-VUqz3YPPWUS58f928XJrzdAYlN_P1sIdRdYid5zWRVr
Scale=1:58.2
0-2-5
0-2-5
T1
T2
T3
B1
W3 W4 W3
W5
W6
W1 W2
T4
B2
1
2 3
4
5
6 7
12 11 10 9 8
13 14 15
16
17
18
19
5x6 4x6
3x5
3x4
3x54x4 3x8
3x4
1.5x4
5x6
5x6
2-1-9
2-1-9
8-5-13
6-4-5
15-5-7
6-11-9
22-8-8
7-3-1
2-1-9
2-1-9
8-5-13
6-4-5
15-5-7
6-11-9
22-8-8
7-3-1
23-8-8
1-0-0
8-6-29-8-13
9-11
-2
10
-6-0
0-5-6
9-8-13
8.0012
PlateOffsets(X,Y): [1:Edge,0-1-12], [2:0-2-12,0-1-8], [5:0-1-12,0-1-8], [6:0-0-0,0-0-15], [9:0-2-12,0-1-8], [11:0-1-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.96
0.68
0.56
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.10
-0.24
0.04
(loc)
6-8
6-8
6
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 124 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPF No.2 *Except*
W6: 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied, except end verticals, and
2-0-0 oc purlins(5-3-0max.): 2-3.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-11, 3-9, 5-9, 1-12
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)12=891/0-3-8(min. 0-1-12), 6=969/0-5-8(min. 0-2-2)
Max Horz12=-464(LC 8)
Max Uplift12=-237(LC 8), 6=-264(LC 11)
MaxGrav12=1117(LC 20), 6=1374(LC 20)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-292/253, 2-13=-688/283, 13-14=-688/283, 14-15=-688/283, 3-15=-688/283,
3-16=-821/273, 16-17=-836/255, 4-17=-903/250, 4-5=-1082/239, 5-18=-1537/271,
18-19=-1795/245, 6-19=-1891/241, 1-12=-1117/263
BOT CHORD 11-12=-172/391, 10-11=-161/322, 9-10=-161/322, 8-9=-83/1427, 6-8=-83/1427
WEBS 2-11=-850/389, 2-9=-243/845, 5-9=-914/309, 5-8=0/302, 1-11=-293/972
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 6-4-7,Interior(1) 6-4-7 to 8-5-13,Exterior(2) 8-5-13 to 12-8-12zone;cantileverleft and right exposed ; end
verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
12=237, 6=264.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
11)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T30
TrussType
HalfHip
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:082014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-VUqz3YPPWUS58f928XJrzdAbKN181mwdRdYid5zWRVr
Scale=1:44.8
0-2-5
W1
T1
T2
B1
W2 W1 W2 W3
W4 W5
B2
1 2 3
4
5
6
11 10 9 8 7
12 13
14
15
16
3x4
4x4 4x4
3x54x4
3x4
3x8
3x4
1.5x4
5x6
6-1-11
6-1-11
11-11-13
5-10-3
17-2-7
5-2-9
22-8-8
5-6-1
6-1-11
6-1-11
11-11-13
5-10-3
17-2-7
5-2-9
22-8-8
5-6-1
23-8-8
1-0-0
7-4-13
7-7-2
8-2-0
0-5-6
7-4-13
8.0012
PlateOffsets(X,Y): [1:0-2-0,0-1-8], [4:0-1-12,0-1-8], [5:0-0-0,0-1-3], [10:0-1-12,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.80
0.51
0.91
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.05
-0.11
0.03
(loc)
5-7
8-10
5
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 110 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud*Except*
W2: 2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-11-4 oc purlins,
except end verticals, and 2-0-0 oc purlins(4-3-12max.): 1-3.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 1-11
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)11=891/0-3-8(min. 0-2-1), 5=969/0-5-8(min. 0-2-4)
Max Horz11=-309(LC 8)
Max Uplift11=-261(LC 8), 5=-258(LC 11)
MaxGrav11=1328(LC 15), 5=1422(LC 16)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-11=-1274/298, 1-12=-846/265, 2-12=-846/265, 2-13=-871/282, 3-13=-866/282,
3-14=-997/290, 14-15=-1045/273, 4-15=-1177/264, 4-16=-1661/283, 5-16=-1823/262
BOT CHORD 10-11=-120/346, 9-10=-204/846, 8-9=-204/846, 7-8=-113/1348, 5-7=-113/1348
WEBS 1-10=-291/1288, 2-10=-857/301, 2-8=-125/395, 3-8=-8/262, 4-8=-652/221
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 11-11-13,Exterior(2) 11-11-13 to 16-2-12zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
11=261, 5=258.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
11)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T31
TrussType
HalfHipGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:092014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-zhOLHuP1HnaylpjEhEr4Wrjl0nPxmEEmgHIF9XzWRVq
Scale=1:41.1
0-2-5
W1
T1
T2
B1
W2
W1 W2 W1 W2 W3
W4 W5
B2
1 2 3 4
5
6
7
13 12 11 10 9 8
14 15 16 17 18 19 20
21
22 23 24 25 26 27
3x8
4x6 5x6
4x63x10
1.5x4 3x4
3x4 3x4
3x4
2x4
3x8
5-3-11
5-3-11
10-5-10
5-1-15
15-5-13
5-0-3
18-9-15
3-4-1
22-8-8
3-10-9
5-3-11
5-3-11
10-5-10
5-1-15
15-5-13
5-0-3
18-9-15
3-4-1
22-8-8
3-10-9
23-8-8
1-0-0
5-0-13
5-3-2
5-10
-0
0-5-6
5-0-13
8.0012
PlateOffsets(X,Y): [1:Edge,0-2-0], [4:0-3-0,0-1-8], [5:0-1-12,0-1-8], [6:0-4-12,0-1-8], [12:0-3-12,0-1-8], [13:0-5-4,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.86
0.28
0.84
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.16
0.14
-0.04
(loc)
9-10
9-10
6
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 119 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x6SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 4-7-15 oc purlins,
except end verticals, and 2-0-0 oc purlins(5-5-3max.): 1-4.
BOT CHORD Rigidceiling directly applied or 4-8-9 oc bracing.
WEBS 1 Row at midpt 1-12
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)13=669/0-3-8(min. 0-1-8), 6=813/0-5-8(min. 0-1-14)
Max Horz13=-242(LC 9)
Max Uplift13=-2072(LC 8), 6=-1382(LC 9)
MaxGrav13=934(LC 13), 6=1198(LC 14)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-13=-886/1889, 1-14=-796/1854, 14-15=-796/1854, 2-15=-796/1854, 2-16=-796/1854,
16-17=-796/1854, 3-17=-796/1854, 3-18=-1048/2465, 18-19=-1046/2462,
19-20=-1044/2462, 4-20=-1044/2460, 4-5=-1121/2253, 5-21=-1268/2137,
6-21=-1494/2127
BOT CHORD 11-12=-2387/1044, 11-24=-2387/1044, 24-25=-2387/1044, 10-25=-2387/1044,
10-26=-1750/834, 26-27=-1750/834, 9-27=-1750/834, 8-9=-1636/1112, 6-8=-1636/1112
WEBS 1-12=-2465/1056, 2-12=-402/639, 3-12=-372/832, 4-10=-880/402, 4-9=-351/301,
5-9=-349/0
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverright exposed ; end verticalright exposed; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
13=2072, 6=1382.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
11)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T31
TrussType
HalfHipGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:092014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-zhOLHuP1HnaylpjEhEr4Wrjl0nPxmEEmgHIF9XzWRVq
NOTES
12) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 181 lb up at 1-4-14, 181 lb up at 3-4-14, 181 lb up at 5-4-14, 181 lb
up at 7-4-14, 181 lb up at 9-4-14, 181 lb up at 11-4-14, and 181 lb up at 13-4-14, and 222 lb up at 15-5-14 on top chord, and 199 lb up at 1-4-14, 199 lb up at 3-4-14,
199lb up at 5-4-14, 199 lb up at 7-4-14, 199 lb up at 9-4-14, 199 lb up at 11-4-14, and 199 lb up at 13-4-14, and 249 lb up at 15-4-14 on bottomchord.The
design/selection of suchconnection device(s)is the responsibility of others.
13)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-4=-60, 4-7=-60, 6-13=-20
Concentrated Loads(lb)
Vert: 4=75(F) 12=7(F) 2=34(F) 9=17(F) 14=34(F) 15=34(F) 16=34(F) 17=34(F) 18=34(F) 20=34(F) 22=7(F) 23=7(F) 24=7(F) 25=7(F) 26=7(F) 27=7(F)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T32GE
TrussType
Monopitch SupportedGable
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:092014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-zhOLHuP1HnaylpjEhEr4WrjwunTfmRimgHIF9XzWRVq
Scale=1:19.0
T1
W1
B1
ST1
1
2
3
4
6 5
7
1.5x3
1.5x32x41.5x3
1.5x3
-1-0-0
1-0-0
4-0-6
4-0-6
0-5-6
3-1-10
3-8-7
8.0012
PlateOffsets(X,Y): [2:0-2-4,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.17
0.04
0.04
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.01
0.00
(loc)
1
1
5
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 16 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 4-0-6 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)5=58/4-0-6(min. 0-1-8), 2=142/4-0-6(min. 0-1-8), 6=171/4-0-6(min. 0-1-8)
Max Horz2=125(LC 9)
Max Uplift5=-27(LC 9), 2=-45(LC 10), 6=-83(LC 10)
MaxGrav5=70(LC 3), 2=179(LC 14), 6=188(LC 3)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-C Corner(3)-1-0-0 to 2-0-6,Exterior(2) 2-0-6 to 3-10-10zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Gablerequirescontinuous bottomchord bearing.
7)Gablestudsspaced at 2-0-0 oc.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 2, 6.
10)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
11)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T33
TrussType
FlatGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:092014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-zhOLHuP1HnaylpjEhEr4WrjwLnQDmQomgHIF9XzWRVq
Scale=1:46.4
W1
T1
W1
B1
W2 W1 W3
1 2 3
7 6 45
3x6
4x4
3x64x8
1.5x4
4x4
1-11-4
1-11-4
3-0-4
1-1-0
3-9-0
0-8-12
1-11-4
1-11-4
3-9-0
1-9-12
8-6-5
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.14
0.20
0.10
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
6
6
5
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 63 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x6SPF No.2
BOT CHORD2x10SP 2400F 2.0E
WEBS 2x4SPF No.2
BRACING
TOP CHORD 2-0-0 oc purlins: 1-3, except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)7=464/Mechanical, 4=-810/1-0-4(min. 0-1-8), 5=2307/0-3-8(min. 0-2-4)
Max Uplift7=-182(LC 6), 4=-958(LC 2), 5=-938(LC 6)
MaxGrav7=543(LC 2), 4=336(LC 6), 5=2717(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
3) Unbalancedsnowloads have been considered for this design.
4)Provide adequate drainage to preventwater ponding.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
7=182, 4=958, 5=938.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
10)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
11) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 1070 lb down and 429 lb up at
1-11-4, and 934 lb down and 274 lb up at 1-11-4 on bottomchord.The design/selection of suchconnection device(s)is the
responsibility of others.
12)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-3=-60, 4-7=-20
Concentrated Loads(lb)
Vert: 6=-1685(F=-819,B=-865)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T34
TrussType
Roof SpecialGirder
Qty
1
Ply
2
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:102014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-RtyjUEQf25ioNzIQFxMJ32F0CBhsVjdwux1oizzWRVp
Scale=1:17.6
W1
T1
W1
B1
B2
B3
B2
B4
W3
W2 W4 W5 W4
W7
W6
1 2 3 4 5
12
11
10 9 8
7 6
13 14
4x4
4x6
4x4
2x4
3x5 3x5
2x4
8x10 8x8
1.5x3
8x10
4x6
1-5-0
1-5-0
4-0-0
2-7-0
6-7-0
2-7-0
7-10-8
1-3-8
1-5-0
1-5-0
4-0-0
2-7-0
6-7-0
2-7-0
7-10-8
1-3-8
2-7-1
1-0-0
PlateOffsets(X,Y): [1:0-1-12,0-1-8], [4:0-1-12,0-1-8], [5:0-2-0,0-1-8], [6:0-1-12,0-2-4], [8:0-7-4,0-5-0], [9:0-4-0,0-4-12], [10:0-6-12,0-5-4], [12:0-1-8,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.45
0.56
0.77
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.05
-0.10
0.10
(loc)
9
9
6
l/defl
>999
>947
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 93 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPFStud*Except*
B1,B4: 2x6SPF No.2, B3: 2x6SP 2400F 2.0E
WEBS 2x4SPFStud*Except*
W2,W6: 2x4SPF No.2
BRACING
TOP CHORD 2-0-0 oc purlins(4-9-0max.): 1-5, except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)12=2672/Mechanical, 6=2699/Mechanical
Max Horz12=90(LC 7)
Max Uplift12=-576(LC 6), 6=-573(LC 7)
MaxGrav12=3233(LC 2), 6=3087(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-12=-3052/601, 1-2=-4195/839, 2-3=-6020/1084, 3-4=-6020/1084, 4-5=-3718/705,
5-6=-2901/571
BOT CHORD 2-10=-860/236, 10-13=-975/4720, 9-13=-929/4419, 9-14=-789/3930, 8-14=-836/4202,
4-8=-1112/234
WEBS 1-10=-1002/5162, 2-9=-375/1739, 4-9=-375/2270, 5-8=-918/4709
NOTES
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-9-0 oc.
Bottomchordsconnected as follows: 2x6- 2 rowsstaggered at 0-3-0 oc, 2x4- 1 row at 0-9-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
4)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
5) Unbalancedsnowloads have been considered for this design.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8) Refer to girder(s) for truss to trussconnections.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
12=576, 6=573.
10)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
11)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
12)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T34
TrussType
Roof SpecialGirder
Qty
1
Ply
2
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:102014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-RtyjUEQf25ioNzIQFxMJ32F0CBhsVjdwux1oizzWRVp
NOTES
13) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 2051 lb down and 333 lb up at 1-11-4, and 1903 lb down and 296 lb
up at 3-11-4, and 1713 lb down and 317 lb up at 5-11-4 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-5=-60, 11-12=-20, 8-10=-20, 6-7=-20
Concentrated Loads(lb)
Vert: 9=-1588(F) 13=-1588(F) 14=-1588(F)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T35
TrussType
FlatGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:102014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-RtyjUEQf25ioNzIQFxMJ32F5jBosVrUwux1oizzWRVp
Scale=1:14.8
W1
T1
W1
B1
W2 W1 W2
1 2 3
6
5 4
7 8
9 10
1.5x3
3x4
1.5x3
3x8
1.5x3 3x4
3-11-4
3-11-4
7-10-8
3-11-4
3-11-4
3-11-4
7-10-8
3-11-4
1-4-1
PlateOffsets(X,Y): [1:0-1-12,0-1-8], [3:0-1-12,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.16
0.11
0.20
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.03
0.00
(loc)
5
5
4
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 29 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD 2-0-0 oc purlins(6-0-0max.): 1-3, except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)6=221/Mechanical, 4=221/Mechanical
Max Horz6=-42(LC 6)
Max Uplift6=-71(LC 6), 4=-71(LC 7)
MaxGrav6=237(LC 2), 4=237(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-7=-450/142, 2-7=-450/142, 2-8=-450/142, 3-8=-450/142
WEBS 1-5=-147/467, 3-5=-147/467
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
3) Unbalancedsnowloads have been considered for this design.
4)Provide adequate drainage to preventwater ponding.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 6, 4.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
10)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
11) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 17 lb down and 52 lb up at
1-11-4, and 17 lb down and 52 lb up at 3-11-4, and 17 lb down and 52 lb up at 5-11-4 on top chord, and 15 lb up at 1-11-4, and
15lb up at 3-11-4, and 15 lb up at 5-11-4 on bottomchord.The design/selection of suchconnection device(s)is the responsibility
of others.
12)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-3=-60, 4-6=-20
Concentrated Loads(lb)
Vert: 5=7(B) 2=47(B) 7=47(B) 8=47(B) 9=7(B) 10=7(B)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T36GE
TrussType
Common SupportedGable
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:112014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-v3W5iaRIpPqf?7tdpftYbGoDvb7MEJJ37bnMEPzWRVo
Scale=1:68.2
W1
T1
T1
W1
B1
ST4
ST3
ST2
ST1
ST3
ST2
ST1
1
2
3
4
5
6
7
8
9
10
11
20 19 18 17 16 15 14 13 12
2x4
3x5
4x4
3x5
2x41.5x31.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
14-8-0
14-8-0
-1-0-0
1-0-0
7-4-0
7-4-0
14-8-0
7-4-0
15-8-0
1-0-0
0-11
-12
9-6-7
10
-2-1
0-11
-12
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.33
0.15
0.16
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.01
0.01
(loc)
11
11
12
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 87 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud*Except*
ST4: 2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 6-16
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS All bearings 14-8-0.
(lb)-Max Horz20=331(LC 9)
Max UpliftAll uplift 100 lb orless at joint(s) except 20=-251(LC 8), 12=-206(LC 9),
17=-159(LC 10), 18=-161(LC 10), 19=-248(LC 10), 15=-158(LC 11), 14=-162(LC
11), 13=-239(LC 11)
MaxGravAllreactions 250 lb orless at joint(s) 17, 18, 19, 15, 14, 13 except
20=324(LC 9), 12=279(LC 8), 16=398(LC 11)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-308/243, 5-6=-80/339, 6-7=-80/339, 9-10=-266/201
WEBS 6-16=-429/0
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-C Corner(3)-1-0-0 to 2-0-0,Exterior(2) 2-0-0 to 7-4-0, Corner(3) 7-4-0 to 10-4-0zone;cantileverleft and right exposed ; end
verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
7)Gablerequirescontinuous bottomchord bearing.
8)Truss to be fullysheathed from one face orsecurely braced againstlateralmovement(i.e. diagonalweb).
9)Gablestudsspaced at 2-0-0 oc.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 251 lb uplift at joint 20, 206 lb uplift at
joint 12, 159 lb uplift at joint 17, 161 lb uplift at joint 18, 248 lb uplift at joint 19, 158 lb uplift at joint 15, 162 lb uplift at joint 14 and
239lb uplift at joint 13.
12)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
13)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T37
TrussType
Monopitch
Qty
6
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:112014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-v3W5iaRIpPqf?7tdpftYbGo5xb28ELs37bnMEPzWRVo
Scale=1:25.8
T1 W1
B1
HW1
1
2
3
4
5
6
7
8
1.5x3
3x5
3x4
3x4
1.5x3
6-10-4
6-10-4
-1-4-0
1-4-0
6-10-4
6-10-4
0-7-12
4-3-5
4-7-15
3-11
-13
0-3-8
4-3-4
6.3512
PlateOffsets(X,Y): [2:0-2-5,0-1-11]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.84
0.49
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.12
-0.30
0.00
(loc)
2-5
2-5
5
l/defl
>663
>265
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 27 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
SLIDER Left 2x4SPFStud 3-8-11
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 5-7-10 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)2=356/0-5-8(min. 0-1-8), 5=260/0-1-8(min. 0-1-8)
Max Horz2=176(LC 9)
Max Uplift2=-129(LC 10), 5=-95(LC 10)
MaxGrav2=394(LC 3), 5=315(LC 3)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)-1-4-0 to 1-8-0,Interior(1) 1-8-0 to 6-8-8zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Bearing at joint(s) 5 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
7)Providemechanicalconnection(by others) of truss to bearing plate at joint(s) 5.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 129 lb uplift at joint 2 and 95 lb uplift at
joint 5.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T37GE
TrussType
GABLE
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:122014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-NG4UvwSwaiyWcGSpNMOn8TLGh?ONzo6DMFWvmszWRVn
Scale=1:25.8
T1 W1
B1
HW1
ST2
ST1
1
2
3
4
5
10
1.5x3
3x5
3x4
3x4
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
6-10-4
6-10-4
-1-4-0
1-4-0
6-10-4
6-10-4
0-7-12
4-3-5
4-7-15
3-11
-13
0-3-8
4-3-4
6.3512
PlateOffsets(X,Y): [2:0-2-5,0-1-11]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.84
0.49
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.12
-0.30
0.00
(loc)
2-5
2-5
5
l/defl
>663
>265
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 31 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
SLIDER Left 2x4SPFStud 3-8-11
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 5-8-6 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)2=356/0-5-8(min. 0-1-8), 5=260/0-1-8(min. 0-1-8)
Max Horz2=176(LC 9)
Max Uplift2=-129(LC 10), 5=-95(LC 10)
MaxGrav2=394(LC 3), 5=315(LC 3)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-C Corner(3)-1-4-0 to 1-8-0,Exterior(2) 1-8-0 to 6-8-8zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Gablestudsspaced at 2-0-0 oc.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Bearing at joint(s) 5 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
9)Providemechanicalconnection(by others) of truss to bearing plate at joint(s) 5.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 129 lb uplift at joint 2 and 95 lb uplift at
joint 5.
11)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
12)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T38
TrussType
HipGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:122014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-NG4UvwSwaiyWcGSpNMOn8TLM0?Onzj8DMFWvmszWRVn
Scale=1:47.1
0-2-5
0-2-5
T1
T2
T1
B1
W1 W2
W3 W4 W5 W4 W3
W2 W1
B21
2
3
4 5 6
7
8
9
15 14 13 12 11 10
16
17 18 19 20 21
22
23 24 25
4x6 4x6
5x6 4x6
3x4
2x4 3x8 2x4
3x8
3x8
3x4
2x4
5x6
4-1-14
4-1-14
7-11-8
3-9-10
12-7-8
4-8-0
17-3-8
4-8-0
21-1-2
3-9-10
25-3-0
4-1-14
-1-4-0
1-4-0
4-1-14
4-1-14
7-11-8
3-9-10
12-7-8
4-8-0
17-3-8
4-8-0
21-1-2
3-9-10
25-3-0
4-1-14
26-7-0
1-4-0
0-7-4
4-4-11
4-7-0
4-11
-11
0-7-4
4-4-11
6.0012
PlateOffsets(X,Y): [2:0-0-0,0-1-3], [8:Edge,0-1-3]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.50
0.46
0.38
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.16
-0.18
0.06
(loc)
12
12
8
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 119 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x6SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-8-10 oc purlins,
except
2-0-0 oc purlins(4-4-14max.): 4-6.
BOT CHORD Rigidceiling directly applied or 5-7-9 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)2=1089/0-5-8(min. 0-2-7), 8=1091/0-5-8(min. 0-2-8)
Max Horz2=-71(LC 9)
Max Uplift2=-969(LC 8), 8=-958(LC 9)
MaxGrav2=1569(LC 18), 8=1595(LC 18)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-16=-2327/1611, 3-16=-2219/1628, 3-4=-1956/1729, 4-17=-1657/1578,
17-18=-1658/1579, 18-19=-1659/1581, 5-19=-1660/1581, 5-20=-1709/1556,
20-21=-1707/1554, 6-21=-1707/1553, 6-7=-2008/1702, 7-22=-2269/1609,
8-22=-2377/1592
BOT CHORD 2-15=-1389/1917, 14-15=-1389/1917, 13-14=-1724/1905, 13-23=-1724/1905,
12-23=-1724/1905, 12-24=-1724/1905, 24-25=-1724/1905, 11-25=-1724/1905,
10-11=-1302/1960, 8-10=-1302/1960
WEBS 3-14=-284/6, 4-14=-365/501, 5-14=-432/436, 5-11=-486/508, 6-11=-378/457,
7-11=-280/0
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone;
cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 969 lb uplift at joint 2 and 958 lb uplift at
joint 8.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
11)Graphical purlinrepresentation does not depict the size or the orientation of the purlin along the top and/or bottomchord.
Continued on page 2
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T38
TrussType
HipGirder
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:122014 Page2StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-NG4UvwSwaiyWcGSpNMOn8TLM0?Onzj8DMFWvmszWRVn
NOTES
12) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 118 lb down and 250 lb up at 7-11-8, 24 lb down and 110 lb up at
9-2-12, 24 lb down and 110 lb up at 11-2-12, 24 lb down and 110 lb up at 13-2-12, and 24 lb down and 110 lb up at 15-2-12, and 118 lb down and 250 lb up at 17-3-8
on top chord, and 48 lb down and 128 lb up at 7-11-8, 4 lb down and 63 lb up at 9-2-12, 4 lb down and 63 lb up at 11-2-12, 4 lb down and 63 lb up at 13-2-12, and 4 lb
down and 63 lb up at 15-2-12, and 48 lb down and 128 lb up at 17-2-12 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of
others.
13)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead + Roof Live(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-4=-60, 4-6=-60, 6-9=-60, 2-8=-20
Concentrated Loads(lb)
Vert: 4=-15(F) 6=-15(F) 13=1(F) 14=-12(F) 11=-12(F) 17=11(F) 18=11(F) 20=11(F) 21=11(F) 23=1(F) 24=1(F) 25=1(F)
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T39
TrussType
Common
Qty
6
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:132014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-rSes7GSYL04NEQ1?w4v0ghtWeOi2iDoMbvGTIIzWRVm
Scale=1:45.5
T1 T1
B1
W2
W1
W2
W1
HW1 HW1
B21
2
3
4
5
6
7
10 9 8
11
12
13 14
15
16
4x6
6x6 3x5 3x4
1.5x4
3x4
1.5x4
6x6
8-5-2
8-5-2
16-9-14
8-4-13
25-3-0
8-5-2
-1-4-0
1-4-0
6-3-14
6-3-14
12-7-8
6-3-10
18-11-2
6-3-10
25-3-0
6-3-14
26-7-0
1-4-0
0-7-4
6-11
-0
7-3-11
0-7-4
6.0012
PlateOffsets(X,Y): [2:Edge,0-2-9], [6:Edge,0-2-9]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.57
0.59
0.16
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.11
-0.31
0.07
(loc)
6-8
6-8
6
l/defl
>999
>958
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 92 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPF No.2 *Except*
W1: 2x4SPFStud
WEDGE
Left: 2x4SPFStud, Right: 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 4-1-9 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)2=1085/0-5-8(min. 0-1-13), 6=1085/0-5-8(min. 0-1-13)
Max Horz2=-101(LC 11)
Max Uplift2=-317(LC 10), 6=-317(LC 11)
MaxGrav2=1172(LC 2), 6=1172(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-11=-1768/361, 3-11=-1685/388, 3-12=-1545/371, 12-13=-1445/383, 4-13=-1441/397,
4-14=-1441/397, 14-15=-1445/383, 5-15=-1545/371, 5-16=-1685/388, 6-16=-1768/361
BOT CHORD 2-10=-331/1465, 9-10=-116/1000, 8-9=-116/1000, 6-8=-231/1465
WEBS 4-8=-151/590, 5-8=-380/250, 4-10=-151/590, 3-10=-380/250
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)-1-4-0 to 1-8-0,Interior(1) 1-8-0 to 12-7-8,Exterior(2) 12-7-8 to 15-7-8zone;cantileverleft and right exposed ; end
verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 317 lb uplift at joint 2 and 317 lb uplift at
joint 6.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T40
TrussType
Common
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:132014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-rSes7GSYL04NEQ1?w4v0ghtXhOiFi8fMbvGTIIzWRVm
Scale=1:36.1
T1 T1
B1
W5
W4 W3
W2
W4W3
W2
B2
W1 W1
1
2 3
4
5
6
7 8
9
13
12 11 10
14
15 16
17
4x4
3x6 3x8
3x10
6x10
3x10
6x10
0-3-6
0-3-6
0-5-6
0-2-0
9-5-6
9-0-0
18-5-6
9-0-0
18-7-6
0-2-0
18-10-12
0-3-6
-1-0-0
1-0-0
0-5-6
0-5-6
4-11-6
4-6-0
9-5-6
4-6-0
13-11-6
4-6-0
18-5-6
4-6-0
18-10-12
0-5-6
19-10-12
1-0-0
0-8-4
5-4-15
5-6-10
0-8-4
6.0012
PlateOffsets(X,Y): [3:0-3-0,0-2-12], [4:0-3-4,0-1-8], [6:0-3-4,0-1-8], [7:0-3-0,0-2-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.50
0.64
0.49
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.13
-0.33
0.03
(loc)
10-11
10-11
10
l/defl
>999
>645
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 78 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)13=807/0-4-0(min. 0-1-8), 10=807/0-4-0(min. 0-1-8)
Max Horz13=82(LC 10)
Max Uplift13=-234(LC 10), 10=-234(LC 11)
MaxGrav13=872(LC 2), 10=872(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-265/0, 3-14=-314/50, 4-14=-274/69, 4-15=-869/202, 5-15=-799/220,
5-16=-799/220, 6-16=-869/202, 6-17=-274/69, 7-17=-314/50, 7-8=-265/0
BOT CHORD 12-13=-211/899, 11-12=-211/899, 10-11=-150/899
WEBS 5-11=-62/454, 6-11=-264/196, 6-10=-806/235, 7-10=-422/241, 4-11=-264/196,
4-13=-806/235, 3-13=-422/242
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)-1-0-0 to 2-0-0,Interior(1) 2-0-0 to 9-5-6,Exterior(2) 9-5-6 to 12-5-6zone;cantileverleft and right exposed ; end
verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)TheFabricationTolerance at joint 7 = 5%,joint 3 = 5%,joint 10 = 5%
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 234 lb uplift at joint 13 and 234 lb uplift
atjoint 10.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T40GE
TrussType
GABLE
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:132014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-rSes7GSYL04NEQ1?w4v0ghtXhOiFi8fMbvGTIIzWRVm
Scale=1:36.7
T1 T1
B1
W5
W4 W3
W2
W4W3
W2
B2
W1 W1
ST3
ST4
ST2ST1
ST3
ST4
ST2 ST1
1
2 3
4
5
6
7 8
9
13
12 11 10
26
27 28
29
4x4
3x6 3x8
3x10
1.5x4
3x10
1.5x4
6x10 6x10
1.5x4
1.5x4
1.5x4
1.5x31.5x3
1.5x4
1.5x3
1.5x4
1.5x3
1.5x4
1.5x4
1.5x3
1.5x4
1.5x3
0-3-6
0-3-6
0-5-6
0-2-0
9-5-6
9-0-0
18-5-6
9-0-0
18-7-6
0-2-0
18-10-12
0-3-6
-1-0-0
1-0-0
0-5-6
0-5-6
4-11-6
4-6-0
9-5-6
4-6-0
13-11-6
4-6-0
18-5-6
4-6-0
18-10-12
0-5-6
19-10-12
1-0-0
0-8-4
5-4-15
5-6-10
0-8-4
6.0012
PlateOffsets(X,Y): [3:0-3-0,0-2-12], [4:0-3-4,0-1-8], [6:0-3-4,0-1-8], [7:18-7-2,0-6-3], [8:0-3-0,0-2-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.50
0.64
0.49
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.13
-0.33
0.03
(loc)
10-11
10-11
10
l/defl
>999
>645
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 95 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)13=807/0-4-0(min. 0-1-8), 10=807/0-4-0(min. 0-1-8)
Max Horz13=82(LC 10)
Max Uplift13=-234(LC 10), 10=-234(LC 11)
MaxGrav13=872(LC 2), 10=872(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-265/0, 3-26=-314/50, 4-26=-274/69, 4-27=-869/202, 5-27=-799/220,
5-28=-799/220, 6-28=-869/202, 6-29=-274/69, 7-29=-314/50, 7-8=-265/0
BOT CHORD 12-13=-211/899, 11-12=-211/899, 10-11=-150/899
WEBS 5-11=-62/454, 6-11=-264/196, 6-10=-806/235, 7-10=-422/241, 4-11=-264/196,
4-13=-806/235, 3-13=-422/242
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)-1-0-0 to 2-0-0,Interior(1) 2-0-0 to 9-5-6,Exterior(2) 9-5-6 to 12-5-6zone;cantileverleft and right exposed ; end
verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
7)TheFabricationTolerance at joint 3 = 5%,joint 8 = 5%,joint 13 = 5%
8)Gablestudsspaced at 2-0-0 oc.
9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 234 lb uplift at joint 13 and 234 lb uplift
atjoint 10.
11)Followingjoints to be plated by qualified designer:Joint(s) 7, not plated.
12)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
13)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T41
TrussType
COMMON
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:142014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-JeBEKcTA6KCEsacBUnQFDuQhDo1SRbrWpZ?0rkzWRVl
Scale=1:34.0
T1
T2
B1
W5
W4 W3
W2
W4W3
W2
B2
W1 W11
2
3
4
5
6 7
8
12
11 10 9
13
14
15
166x10
4x4
3x6 3x8
3x103x10
6x10
0-3-6
0-3-6
0-5-6
0-2-0
9-5-6
9-0-0
18-5-6
9-0-0
18-7-6
0-2-0
18-10-12
0-3-6
0-5-6
0-5-6
4-11-6
4-6-0
9-5-6
4-6-0
13-11-6
4-6-0
18-5-6
4-6-0
18-10-12
0-5-6
19-10-12
1-0-0
0-8-4
5-4-15
5-6-10
0-8-4
6.0012
PlateOffsets(X,Y): [1:0-3-0,0-2-12], [3:0-3-4,0-1-8], [5:0-3-4,0-1-8], [7:0-3-0,0-2-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.52
0.64
0.50
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.13
-0.34
0.03
(loc)
10-12
10-12
9
l/defl
>999
>644
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 77 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)12=735/0-4-0(min. 0-1-8), 9=810/0-4-0(min. 0-1-8)
Max Horz12=-96(LC 11)
Max Uplift12=-173(LC 10), 9=-234(LC 11)
MaxGrav12=792(LC 2), 9=875(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-282/0, 2-13=-412/133, 3-13=-301/143, 3-14=-877/210, 4-14=-806/228,
4-15=-806/222, 5-15=-876/203, 5-16=-274/71, 6-16=-314/52, 6-7=-265/0,
1-12=-197/307
BOT CHORD 11-12=-224/917, 10-11=-224/917, 9-10=-154/905
WEBS 4-10=-67/457, 5-10=-257/196, 5-9=-812/237, 6-9=-423/242, 3-10=-278/205,
3-12=-721/184, 2-12=-489/349
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 9-5-6,Exterior(2) 9-5-6 to 12-5-6zone;cantileverleft and right exposed ; end
verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)TheFabricationTolerance at joint 1 = 5%,joint 7 = 5%,joint 12 = 5%
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 173 lb uplift at joint 12 and 234 lb uplift
atjoint 9.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T42
TrussType
Roof Special
Qty
6
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:142014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-JeBEKcTA6KCEsacBUnQFDuQh_oypRXtWpZ?0rkzWRVl
Scale=1:35.0
T1 T2
B1
B2
B3
W2
W1
W3
W4
HW2
F1
1
2
3
4
5
6
7
10
9 8
11
12
13
14
3x8
1.5x3
5x8
2x4
5x6 3x8
6x16MT18H
1.5x4
6x8
4x4
0-3-6
0-3-6
0-8-14
0-5-8
4-0-0
3-3-2
9-5-6
5-5-6
18-7-6
9-2-0
18-10-12
0-3-6
4-0-0
4-0-0
9-5-6
5-5-6
13-8-5
4-2-15
18-10-12
5-2-7
19-10-12
1-0-0
0-5-4
5-1-15
5-6-10
0-8-4
0-3-0 1-0-13
1-0-13
6.0012
3.0012
PlateOffsets(X,Y): [1:0-0-14,0-0-8], [3:0-3-12,0-1-0], [6:0-4-6,Edge], [9:0-3-0,0-3-0], [10:0-10-12,0-4-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.53
1.00
0.75
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.16
-0.43
0.19
(loc)
10
6-8
6
l/defl
>999
>527
n/a
L/d
360
240
n/a
PLATES
MT20
MT18H
Weight: 85 lb FT= 10%
GRIP
197/144
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2 *Except*
B1: 2x6SPF No.2, F1: 2x4SPFStud
WEBS 2x4SPFStud
SLIDER Right 2x6SPF No.2 2-10-4
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-2-4 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.Except:
1-5-0 oc bracing: 9-10
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)1=745/0-5-8(min. 0-1-8), 6=808/0-4-0(min. 0-1-8)
Max Horz1=-81(LC 11)
Max Uplift1=-177(LC 10), 6=-231(LC 11)
MaxGrav1=803(LC 2), 6=873(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-11=-2758/608, 2-11=-2659/619, 2-12=-2549/698, 3-12=-2475/713, 3-13=-865/245,
4-13=-929/232, 4-5=-1129/299, 5-14=-1161/287, 6-14=-1215/277
BOT CHORD 1-10=-569/2452, 8-9=-78/303, 6-8=-183/1010
WEBS 8-10=0/489, 3-10=-544/1747, 3-8=-37/288, 4-8=-324/199
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-2-12 to 3-2-12,Interior(1) 3-2-12 to 9-5-6,Exterior(2) 9-5-6 to 12-5-6zone;cantileverleft and right exposed ; end
verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)All plates areMT20 plates unless otherwiseindicated.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Bearing at joint(s) 1 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 177 lb uplift at joint 1 and 231 lb uplift at
joint 6.
10)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
11)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T43
TrussType
Monopitch
Qty
3
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:152014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-orlcXyUotdK5TkBO2VxUm6zw1CU8A6Uf2DlZNBzWRVk
Scale=1:19.1
T1
W3
B1
W1 W2
1
2
3
4
6 5
7
8
1.5x3
2x4
3x4
1.5x3 3x4
4-11-12
4-11-12
8-0-0
3-0-4
-1-4-0
1-4-0
4-11-12
4-11-12
8-0-0
3-0-4
0-4-8
3-0-8
3-5-0
2-9-0
0-3-8
3-0-8
4.0012
PlateOffsets(X,Y): [2:0-0-5,0-0-5]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.32
0.23
0.15
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.02
-0.05
0.01
(loc)
2-6
2-6
5
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 28 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)2=408/0-5-8(min. 0-1-8), 5=295/0-1-8(min. 0-1-8)
Max Horz2=136(LC 9)
Max Uplift2=-167(LC 8), 5=-90(LC 10)
MaxGrav2=456(LC 3), 5=361(LC 3)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-7=-518/74, 7-8=-466/78, 3-8=-420/86
BOT CHORD 2-6=-176/438, 5-6=-176/438
WEBS 3-5=-511/164
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)-1-4-0 to 1-8-0,Interior(1) 1-8-0 to 7-10-4zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Bearing at joint(s) 5 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
7)Providemechanicalconnection(by others) of truss to bearing plate at joint(s) 5.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 167 lb uplift at joint 2 and 90 lb uplift at
joint 5.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T43GE
TrussType
GABLE
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:152014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-orlcXyUotdK5TkBO2VxUm6zw1CU8A6Uf2DlZNBzWRVk
Scale=1:19.1
T1
W3
B1
W1 W2
ST2
ST3ST1
1
2
3
4
6 5
12
13
1.5x3
2x4
3x4
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
1.5x3
3x4
4-11-12
4-11-12
8-0-0
3-0-4
-1-4-0
1-4-0
4-11-12
4-11-12
8-0-0
3-0-4
0-4-8
3-0-8
3-5-0
2-9-0
0-3-8
3-0-8
4.0012
PlateOffsets(X,Y): [2:0-0-5,0-0-5]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.32
0.23
0.15
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.02
-0.05
0.01
(loc)
2-6
2-6
5
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 31 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)2=408/0-5-8(min. 0-1-8), 5=295/0-1-8(min. 0-1-8)
Max Horz2=136(LC 9)
Max Uplift2=-167(LC 8), 5=-90(LC 10)
MaxGrav2=456(LC 3), 5=361(LC 3)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-12=-518/162, 12-13=-466/168, 3-13=-420/176
BOT CHORD 2-6=-309/438, 5-6=-309/438
WEBS 3-5=-511/320
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-C Corner(3)-1-4-0 to 1-8-0,Exterior(2) 1-8-0 to 7-10-4zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
6)Gablestudsspaced at 2-0-0 oc.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Bearing at joint(s) 5 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
9)Providemechanicalconnection(by others) of truss to bearing plate at joint(s) 5.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 167 lb uplift at joint 2 and 90 lb uplift at
joint 5.
11)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
12)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
T44
TrussType
Monopitch
Qty
4
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:152014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-orlcXyUotdK5TkBO2VxUm6zpDCPYA3Vf2DlZNBzWRVk
Scale=1:25.2
T1 W3
B1
W1 W2
1
2
3
4
6 5
7
8
9
1.5x3
3x6
3x4
1.5x3 3x4
8-1-0
8-1-0
11-7-4
3-6-4
-1-4-0
1-4-0
8-1-0
8-1-0
11-7-4
3-6-4
0-4-8
4-2-14
4-7-7 3-11
-6
0-3-8
4-2-14
4.0012
PlateOffsets(X,Y): [2:0-2-1,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.75
0.52
0.34
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.10
-0.29
0.01
(loc)
2-6
2-6
5
l/defl
>999
>460
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 40 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 5-11-3 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)2=549/0-5-8(min. 0-1-8), 5=443/0-1-8(min. 0-1-8)
Max Horz2=192(LC 9)
Max Uplift2=-202(LC 8), 5=-139(LC 10)
MaxGrav2=616(LC 3), 5=556(LC 3)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-7=-747/113, 7-8=-666/123, 3-8=-587/136
BOT CHORD 2-6=-202/628, 5-6=-202/628
WEBS 3-6=0/305, 3-5=-819/235
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)-1-4-0 to 1-8-0,Interior(1) 1-8-0 to 11-5-8zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 23.1 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Bearing at joint(s) 5 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
7)Providemechanicalconnection(by others) of truss to bearing plate at joint(s) 5.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 202 lb uplift at joint 2 and 139 lb uplift at
joint 5.
9)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
V01
TrussType
Valley
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:162014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-G1J_lIVQexSy5umacCTjIJV8acsZva_oHsU7vdzWRVj
Scale=1:26.3
T1 T1
B1
ST2
ST1 ST1
1
2
3
4
5
8 7 62x4
4x4
2x41.5x3
1.5x3
1.5x3
1.5x3
1.5x3
6-9-6
6-9-6
3-4-11
3-4-11
6-9-6
3-4-11
3-11
-8
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.08
0.02
0.07
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 25 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
OTHERS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS All bearings 6-9-6.
(lb)-Max Horz1=-122(LC 8)
Max UpliftAll uplift 100 lb orless at joint(s) 1, 5 except 8=-170(LC 10), 6=-170(LC 11)
MaxGravAllreactions 250 lb orless at joint(s) 1, 5, 7, 8, 6
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-C Corner(3)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS
forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
5) Unbalancedsnowloads have been considered for this design.
6)Gablestudsspaced at 2-0-0 oc.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 5 except(jt=lb)
8=170, 6=170.
9) Non Standard bearingcondition. Reviewrequired.
10)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
11)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
V02
TrussType
Valley
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:162014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-G1J_lIVQexSy5umacCTjIJV8FcsHvbroHsU7vdzWRVj
Scale:3/4"=1'
T1 T1
B1
ST1
1
2
3
4
2x4
4x4
2x41.5x3
4-5-12
4-5-12
4-5-15
0-0-3
2-3-0
2-3-0
4-5-15
2-3-0
0-0-4
2-7-8
0-0-4
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.10
0.04
0.02
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 14 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
OTHERS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 4-5-15 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)1=98/4-5-9(min. 0-1-8), 3=98/4-5-9(min. 0-1-8), 4=113/4-5-9(min. 0-1-8)
Max Horz1=-77(LC 8)
Max Uplift1=-40(LC 11), 3=-36(LC 10)
MaxGrav1=107(LC 2), 3=107(LC 2), 4=119(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS
forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
V03
TrussType
Valley
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:162014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-G1J_lIVQexSy5umacCTjIJV9TcsVvb5oHsU7vdzWRVj
Scale=1:9.3
T1 T1
B1
1
2
3
2x4
3x4
2x4
2-2-5
2-2-5
2-2-9
0-0-3
1-1-4
1-1-4
2-2-9
1-1-4
0-0-4
1-3-8
0-0-4
14.0012
PlateOffsets(X,Y): [2:Edge,0-3-1]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.02
0.03
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 5 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 2-2-9 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)1=63/2-2-2(min. 0-1-8), 3=63/2-2-2(min. 0-1-8)
Max Horz1=31(LC 9)
Max Uplift1=-14(LC 11), 3=-14(LC 10)
MaxGrav1=68(LC 2), 3=68(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS
forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
8)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
V04
TrussType
Valley
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:162014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-G1J_lIVQexSy5umacCTjIJV7Ucrgvb5oHsU7vdzWRVj
Scale=1:20.0
T1
T2
T3
W1
B1
1
2
3
4
5
3x4
3x4
3x4
2x4
1.5x3
3-3-13
3-3-13
0-10-1
0-10-1
2-10-1
2-0-0
3-3-13
0-5-12
0-0-4
0-8-13
2-9-133-4-8
10.5012
12.5012
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.15
0.08
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 12 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-3-13 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)1=111/3-3-8(min. 0-1-8), 5=111/3-3-8(min. 0-1-8)
Max Horz1=120(LC 9)
Max Uplift1=-12(LC 8), 5=-67(LC 9)
MaxGrav1=120(LC 2), 5=120(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-4-11 to 0-10-1,Interior(1) 0-10-1 to 3-2-1zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 5.
7)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
8)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
V05
TrussType
Valley
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:172014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-kDtMydV2PFapj2Lm9w_yrX2JC0Cke2LyVWEgS3zWRVi
Scale=1:14.9
T1
T2
W1
B1
1
2
3
4
2x4
3x4
1.5x4
1.5x3
2-2-11
2-2-11
1-8-15
1-8-15
2-2-11
0-5-12
0-0-4
1-9-13
2-4-8
12.5012
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.08
0.03
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 8 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 2-2-11 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)1=69/2-2-7(min. 0-1-8), 4=69/2-2-7(min. 0-1-8)
Max Horz1=77(LC 9)
Max Uplift1=-10(LC 8), 4=-45(LC 9)
MaxGrav1=75(LC 2), 4=75(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-4-2 to 1-8-15,Interior(1) 1-8-15 to 2-0-15zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 4.
7)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
8)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
V06
TrussType
GABLE
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:172014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-kDtMydV2PFapj2Lm9w_yrX28L0BIe1PyVWEgS3zWRVi
Scale=1:41.0
T1
T2
W1
B1
ST1
1
2
3
4
6 5
7
2x4
3x4
1.5x3
1.5x31.5x3
1.5x3
6-4-5
6-4-5
3-2-9
3-2-9
6-4-5
3-1-12
0-0-4
3-4-3
7-0-3
12.5012
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.78
0.12
0.12
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 27 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)1=18/6-4-5(min. 0-1-8), 5=121/6-4-5(min. 0-1-8), 6=330/6-4-5(min. 0-1-8)
Max Horz1=273(LC 9)
Max Uplift1=-113(LC 8), 5=-122(LC 9), 6=-306(LC 10)
MaxGrav1=217(LC 9), 5=151(LC 8), 6=378(LC 3)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-7=-578/178, 2-7=-566/180, 2-3=-302/137, 3-4=-288/157, 4-5=-135/276
WEBS 2-6=-299/401
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-4-2 to 3-2-9,Interior(1) 3-2-9 to 6-2-9zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
1=113, 5=122, 6=306.
7)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
8)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
V07
TrussType
Valley
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:172014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-kDtMydV2PFapj2Lm9w_yrX2Ca09oe2LyVWEgS3zWRVi
Scale=1:34.6
T1
T2
W1
B1
1
2
3
4
5
4x6
3x5
3x6
3x4
5-0-15
5-0-15
1-11-3
1-11-3
5-0-15
3-1-12
0-0-4
2-0-3
5-8-3
12.5012
14.0012
PlateOffsets(X,Y): [1:0-4-12,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.57
0.22
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 20 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 5-0-15 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)1=184/5-0-11(min. 0-1-8), 4=184/5-0-11(min. 0-1-8)
Max Horz1=217(LC 9)
Max Uplift1=-36(LC 8), 4=-131(LC 9)
MaxGrav1=204(LC 3), 4=200(LC 3)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-5=-274/85, 2-5=-264/95, 2-3=-256/115, 3-4=-124/278
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-4-2 to 1-11-3,Interior(1) 1-11-3 to 4-11-3zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1 except(jt=lb)
4=131.
7)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
8)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
V08
TrussType
Valley
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:182014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-CPRlAzWhAYigKBwzjdVBNkbRfPXcNVb5kAzE_VzWRVh
Scale=1:24.9
T1
W1
B1
1
2
32x4
1.5x3
1.5x3
3-8-12
3-8-12
0-0-4
4-4-3
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.29
0.12
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 14 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 3-8-12 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)1=131/3-8-8(min. 0-1-8), 3=131/3-8-8(min. 0-1-8)
Max Horz1=160(LC 9)
Max Uplift1=-30(LC 8), 3=-101(LC 9)
MaxGrav1=141(LC 2), 3=141(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-253/104, 2-3=-108/258
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS
forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1 except(jt=lb)
3=101.
7)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
8)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
V09
TrussType
Valley
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:182014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-CPRlAzWhAYigKBwzjdVBNkbTCPYfNVb5kAzE_VzWRVh
Scale=1:18.2
T1
W1
B1
1
2
3
2x4
1.5x3
1.5x3
2-7-0
2-7-0
0-0-4
3-0-3
14.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.13
0.05
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 10 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 2-7-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)1=85/2-6-13(min. 0-1-8), 3=85/2-6-13(min. 0-1-8)
Max Horz1=104(LC 9)
Max Uplift1=-20(LC 8), 3=-65(LC 9)
MaxGrav1=91(LC 2), 3=91(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS
forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
7)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
8)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
V10
TrussType
GABLE
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:182014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-CPRlAzWhAYigKBwzjdVBNkbQ9PWmNUO5kAzE_VzWRVh
Scale=1:19.5
T1
W1
B1
ST1
1
2
3
5 4
6
7
8
2x4
1.5x3
1.5x31.5x3
1.5x3
8-11-13
8-11-13
0-0-4
2-11
-15
4.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.33
0.17
0.08
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 24 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)1=123/8-11-13(min. 0-1-8), 4=114/8-11-13(min. 0-1-8), 5=395/8-11-13(min. 0-1-8)
Max Horz1=125(LC 9)
Max Uplift1=-15(LC 8), 4=-30(LC 10), 5=-139(LC 10)
MaxGrav1=133(LC 2), 4=145(LC 3), 5=447(LC 3)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 2-5=-348/215
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-11-5 to 3-11-5,Interior(1) 3-11-5 to 8-10-1zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 4 except(jt=lb)
5=139.
7)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
8)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
V11
TrussType
Valley
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:182014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-CPRlAzWhAYigKBwzjdVBNkbO6PULNVb5kAzE_VzWRVh
Scale=1:13.4
T1
W1
B1
1
2
3
4
5
6
2x4
1.5x3
1.5x3
5-11-13
5-11-13
0-0-4
1-11
-15
4.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.46
0.26
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 14 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 5-11-13 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)1=196/5-11-1(min. 0-1-8), 3=196/5-11-1(min. 0-1-8)
Max Horz1=78(LC 9)
Max Uplift1=-51(LC 8), 3=-63(LC 10)
MaxGrav1=213(LC 3), 3=220(LC 3)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2) 0-11-5 to 3-11-5,Interior(1) 3-11-5 to 5-10-1zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
7)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
8)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard
DE Job # 33078-W1
Dansco Engineering, LLC
Date: 3/28/14
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional
information.
Job
1410484-12T
Truss
V12
TrussType
Valley
Qty
1
Ply
1
1410484-12TContract / EstridgeGlenOaks-1
Job Reference (optional)
Run:7.420 sMay102013 Print:7.420 s May102013MiTekIndustries,Inc.FriMar2810:56:192014 Page1StarkTruss CompanyInc., RensselaerIN47978 ID:VsXQ4B7xjMCXU5zJ4TGvN0zWoKR-gc?7NJXJwsrXyLU9HK0Qwy7fypu16yrFzqjnWyzWRVg
Scale=1:7.7
T1
W1
B1
1
2
3
2x4
1.5x3
1.5x3
2-11-13
2-11-13
0-0-4
0-11
-15
4.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
PlatesIncrease
LumberIncrease
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.07
0.04
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 6 lb FT= 10%
GRIP
197/144
LUMBER
TOP CHORD2x4SPF No.2
BOT CHORD2x4SPF No.2
WEBS 2x4SPFStud
BRACING
TOP CHORD Structuralwoodsheathing directly applied or 2-11-13 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS (lb/size)1=76/2-11-1(min. 0-1-8), 3=76/2-11-1(min. 0-1-8)
Max Horz1=31(LC 9)
Max Uplift1=-20(LC 8), 3=-24(LC 10)
MaxGrav1=82(LC 2), 3=82(LC 2)
FORCES (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES
1)Wind:ASCE 7-05; 90mph;TCDL=5.0psf;BCDL=5.0psf; h=30ft; Cat. II;Exp C; enclosed;MWFRS(low-rise) gable end zone and
C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS
forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-05;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=30.0 psf(groundsnow);Pf=23.1 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
7)This trussis designedin accordancewith the 2006 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
8)"Semi-rigid pitchbreakswith fixed heels"Member end fixitymodelwas usedin the analysis and design of this truss.
LOADCASE(S)Standard