HomeMy WebLinkAboutA104 LIGHTING_ELECTRICAL PLAN.PDFProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date #CAD Technician #Architect PEDCOR DESIGN GROUP LLC A104 LIGHTING/ ELECTRICAL PLAN THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLEPROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALLINFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSIONAND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALLINFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL ANDUNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, ANDPEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, ORPORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED,MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THESPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2014JAMES R. STUTZMAN, AIA, Carmel, Indiana. #Project Status SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA CAREA B R KEY PLAN BLDG A CONDO 601 Th u r s d a y , F e b r u a r y 2 7 , 2 0 1 4 ; A L L D A T A : M S : D E S I G N : P R O J E C T S : C A R M E L C I T Y C E N T E R : C C C D r a w i n g s : C C C C o n s t r u c t i o n D o c : B u i l d i n g A : A . 5 0 0 : P E N T H O U S E C D s : P e n t h o u s e T e n a n t s : U N I T 6 0 1 - P E D I G O : D R A W I N G S : I B A S E - 6 0 1 0 2 0 3 1 4 . p l n STATE RELEASE 02.18.14 CA R M E L C I T Y C E N T E R - B U I L D I N G A CO N D O M I N I U M U N I T 6 0 1 72 0 S . R a n g e l i n e R o a d Ca r m e l , I n 4 6 0 3 2 SPS, MCAJR 02.18.14 State Release Set T DS DUPLEX WALL OUTLET. CABLE TV OUTLET. ELECTRICAL/DATA LEGEND: GROUND FAULT INTERRUPT CIRCUIT OUTLET. PHONE/DATA WALL OUTLET (BOX AND PULL STRING). +44"HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. 1/2 SWITCHED OUTLET. SPECIAL PURPOSE OUTLET, REFER TO EQUIPMENTSPECIFICATIONS FOR POWER REQUIREMENTS AND TYPE. THERMOSTAT, MOUNT @ 48" AFF. JUNCTION BOX FOR LIGHTS IN FUTURE CABINETS. ELECTRICAL/DATA PLAN NOTES: EP1 EP2 EP3 MOUNT OUTLETS HORIZONTAL IN BACKSPLASH. PROVIDE FLUSH MOUNT IN-FLOOR ELECTRICAL TO BE: XXX. INCLUDE 8' OF CONDUIT; RUN 4'O.C. IN EACH DIRECTION OF OUTLET. PROVIDE JUNCTION BOX AT CEILING FOR FUTURE MOTORIZED SHADES. PROVIDE CONDUIT AT CEILING FOR FUTURE TV/DATA. PROVIDE JUNCTION BOX FOR FUTURE PICTURE LIGHT/SCONCE. PROVIDE DEDICATED QUAD OUTLET FOR TENANT A/V RACK. EP4 EP5 EP6 EP7 QUAD FLOOR OUTLET. DEDICATED QUAD CIRCUIT OUTLET.D PROVIDE POWER FOR FUTURE ICE MAKER.EP8 PROVIDE POWER FOR DUAL-ZONE WINE CABINET.EP9 SERVICE PANEL. PROVIDE POWER FOR MOTORIZED RECESSED PROJECTOR SCREEN.EP10 PROVIDE (2) 15 AMP DEDICATED CIRCUITS FOR PROJECTOR AND ELECTRONICS.EP11 17.IF AN ELECTRICAL OUTLET IS NOT DIMENSIONED, PLACE IT IN THE MIDDLE OF THE WALL SEGMENT IT LAYS ON. 16.ANY RECESSED ELECTRICAL BOXES/ DEVICES IN DEMISING WALLS BETWEEN SEPARATE UNITSARE TO BE STAGGERED (SEPARATE STUD CAVITIES) RELATIVE TO ONE ANOTHER TO MINIMIZE ANY SOUND TRANSMISSION BETWEEN UNITS. GENERAL ELECTRICAL/DATA NOTES: PROVIDE FLOOR MOUNTED POWER/COMMUNICATIONS AS TOMBSTONES. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING ATPHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICALREQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE. MATCH QUALITY AND STYLE OF UNIT 605. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF TO THE CENTERLINE OF THE DEVICE UNLESS NOTED OTHERWISE. 7. 9. 10. 11. 6. 5. 4. 3. 8. ALL PENETRATIONS THROUGH THE DEMISING WALL BETWEEN THE TENANT AND THE SERVICECORRIDOR NEED TO BE FIRE RATED. USE WHITE FIRE RATED CAULK. FIRE ALARM SYSTEM SHALL BE COMPATIBLE AND TIED TO THE EXISTING BUILDING FIRE ALARMSYSTEM. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR & ENGINEER TOVERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITHTHE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OFTHERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. 1. 2. ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETYSYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATECODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TOARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. ALL MECHANICAL WORK SHALL COMPLY WITH 2008 INDIANA MECHANICAL CODE (IMC 2006) 675 IAC 18.1-5. ALL ELECTRICAL WORK SHALL COMPLY WITH 2009 INDIANA ELECTRICAL CODE EDITION (NFPA 70-2008) 675 IAC 17-1.8. ALL PLUMBING WORK SHALL COMPLY WITH 2012 INDIANA PLUMBING CODE 675 IAC 16-1.4. USE ARC-FAULT CIRCUIT INTERRUPTION (ACFI) DEVICES ON ALL RECEPTACLES IN HABITABLEAREAS.12. 13. 14. 15. DOOR SWITCH. PROVIDE ELECTRICAL SOURCE FOR WATER FOUNTAIN PUMP.EP12 28 27.5 27 26.5 26 M N PN.5M.5 F T CL R SD SD SD S SD SD S CL T 3A406 9'-0" 9'-0" 11'-5" TOP OF DOME 9'-0" 10'-0" 8'-11" TOP OF ARCH8'-11" TOP OF ARCH 8'-11" TOP OF ARCH 8'-11" TOP OF ARCH 8'-11" TOP OF ARCH 10'-0"10'-0" 9'-0" 9'-0" 9'-0" 9'-0"9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0"9'-0" 9'-0" 9'-0" 9'-0"9'-0" 9'-0" 9'-0" 9'-0" 8'-4" 9'-0" 9'-0" 10'-0" 9'-0"9'-0" 9'-0" 8'-0" 8'-0"8'-0" 8'-4" 8'-4" 8'-4" 9'-6" 9'-6" 9'-6" 9'-6" 9'-0" DSDIM. DIM. DIM. DIM. DSDS DS DS DS EP1 EP3 EP3 EP2EP2 EP4 EP4 EP5 DIM.DIM. EP6 EP7 DIM. DIM. DIM. DIM.EP8 EP4 EP4 EP4 EP4 DIM. DIM. EP10 EP11 FACE OFCROWN MOULD. FACE OFCROWN MOULD.FACE OFCROWN MOULD. FACE OFCROWN MOULD. DIM. EP12 I-1 F EE C D C DIS-POSAL +48 +44 +44 +32 C C D +44 +44 +32 +32 +44GFI D D DIS-POSAL +44 GFI +44 +44 +72 +44 +44 +64 +64 +64 +64 +64+64+64 +44 +44 GFI +44 GFI +64 +64 +64 +120 +120 +32 +32 +44GFI +44GFI D D D D D D D DD D D D I-1 CC AA D D E E C C C C C G C D D D D D D D D C D D F E F E D D C C D D H H EE D F D D D D D D D D D C C D D D D D D D D D DDDD D D D D D D II J J J J +76" +64 +64 +48 +132 +132 +72D +48" +44 GFI EE E A D D C +44 +44 +32 D +120 +120 +132 +132 G B B D D D D D D D+96D+96 +120 KITCHEN108 COATS103 LIVING ROOM105 MASTER BEDROOM 119 CLOSET112A MASTER BATH 120 MASTER CLOSET119B GUESTBATH113 DINNING107 HALL 114 FOYER100 MECH. 111 POWDERROOM104 REAR ENTRY HALL109 TERRACE MASTERCLOSET 119A GUESTBATH118 COATS102 HEARTH ROOM106 GUESTBEDROOM112 LINEN 118A LINEN116 DEN/OFFICESPARE BEDROOM 117 CLOSET117A HALL101 LAUNDRY115 LINEN 113B CLOSET117B MECH. 114A DDDD DDDDD DDD J J DD DD DD DD DD DD D D D D D +66 +66 DW EP9 SCALE: 1/4" = 1'-0" 1 Lighting/Electrical Plan A104 0 2'4'8'