Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
L100 LIFE SAFETY PLAN.PDF
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date #CAD Technician #Architect PEDCOR DESIGN GROUP LLC L100 LIFE SAFETY PLAN THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLEPROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALLINFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSIONAND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALLINFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL ANDUNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, ANDPEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, ORPORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED,MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THESPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2014JAMES R. STUTZMAN, AIA, Carmel, Indiana. #Project Status SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA CAREA B R KEY PLAN BLDG A CONDO 601 Th u r s d a y , F e b r u a r y 2 7 , 2 0 1 4 ; A L L D A T A : M S : D E S I G N : P R O J E C T S : C A R M E L C I T Y C E N T E R : C C C D r a w i n g s : C C C C o n s t r u c t i o n D o c : B u i l d i n g A : A . 5 0 0 : P E N T H O U S E C D s : P e n t h o u s e T e n a n t s : U N I T 6 0 1 - P E D I G O : D R A W I N G S : I B A S E - 6 0 1 0 2 0 3 1 4 . p l n STATE RELEASE 02.18.14 CA R M E L C I T Y C E N T E R - B U I L D I N G A CO N D O M I N I U M U N I T 6 0 1 72 0 S . R a n g e l i n e R o a d Ca r m e l , I n 4 6 0 3 2 SPS, MCAJR 02.18.14 State Release Set N 28 27.5 27 26.5 26 24 23 22 21.5 20 21 25 28 27.5 27 26.5 26 24 23 22 21.5 20 21 25 24 23 24 23 28 27.5 27 26.5 26 25 28 27.5 27 26.5 26 25 22 21.5 20 21 22 21.5 20 21 M N P Q RQ.5P.5N.5M.5M N P Q RQ.5P.5N.5M.5 667.75 sq ft 75.11 sq ft SCALE: 1/16" = 1'-0" 1 Overall Sixth Floor Plan L100 0 8'16'32' F RKITCHEN108 COATS103 LIVING ROOM105 MASTER BEDROOM119 CLOSET112A MASTERBATH120 MASTERCLOSET119B GUESTBATH113 SV SW DINNING107 HALL114 FOYER100 MECH.111 POWDERROOM104 REAR ENTRY HALL109 TERRACE MASTERCLOSET119AGUESTBATH118 COATS102 HEARTH ROOM106 GUESTBEDROOM112 LINEN118A LINEN116 DEN/OFFICESPARE BEDROOM117 CLOSET117A HALL101 LAUNDRY115 LINEN113B CLOSET117B MECH.114A SWSVSV SV DR DR SV DW 601 CONDOLIFE SAFETY & CODE SUMMARY PROJECT SUMMARY This project is a new single-tenant residential project known as the 601 CONDO, occupying 3,466 square feet, with an 809 square foot Outdoor Terrace, of the sixth (6th)floor of an existing Shell and Core project known as Carmel City Center. 601 CONDO is a Group R-2 occupancy, and the construction type is I-B. The entire facility is fully protected by an automatic sprinkler system, and is surrounded by at least 30 feet of yard depth. The 601 CONDO is a Residential Occupancy. APPLICABLE CODES & STANDARDS Indiana General Administrative Rules (675 IAC 12) 2006 0- OCCUPANCY CLASSIFICATIONS: 601 CONDO Tenant: Group R-2 Building Shell & Core: Group A-2, A-3, B, M, R-2 Parking Garage: Group S-2, B, M OCCUPANT LOAD601 CONDO Living Space 3,466 sq ft R-2 Occupancy @ 200 sf/person 17 persons 601 CONDO Outdoor Terrace 809 sq ft R-2 Occupancy @ 200 sf/person 4 persons 601 CONDO Total Gross Area 4,276 sq ft CONSTRUCTION TYPES: 601 CONDO Tenant: Type I-B Upper Building Shell & Core: Type I-BParking Garage: Type I-A BUILDING AREAS: 601 CONDO Tenant: 3,466 sf Shell & Core: (Total Building A) 309,587 sf FIRE RESISTANCEResidential & Shell & Core (Ground Floor): Walls: All construction to be non-combustible Exit Passageways: 2 hours Fire walls: 2 hoursExit Access Corridors: 1 hourCeiling: 3 hours INTERIOR FINISHES Residential & Shell & Core (Ground Floor): Vertical Exits & Passageways: Class BExit Access Corridors Class CAll Others Class C FIRE PROTECTION 100% protection by an automatic sprinkler system per NFPA 13-2010 100% protection by a fire alarm & enunciator system meeting NFPA 72-2002Sprinkler fire pump and backup power meeting NFPA 20-1999Stairway pressurization meeting IBC 2008 and NFPA 92A-2002 ACCESSIBILITY REQUIREMENTS All tenant restrooms comply with ICC/ANSI A117.1-2003; Section 604.5.1; and 2010 ADA PREVIOUS IDHS APPROVALSProject No. 317769 CDR Letter Foundation Release 04.25.06Project No. 317796 CDR Letter Standard Release - Architectural & Structural 06.19.07 4'-6" Unit 60175'-3" 92'-11" 22'-6" 56'-3"