Loading...
HomeMy WebLinkAbout06010040-Site Plan577 Y Qmd. IN 40074 Fm R.H. of Indleno 600 S.F.J:, in (5o'RAV) Community Rssb'iction~: S~eY d=3 min. Rea' Ywd =, N/A, Aggregate = 6 R.H, of Indona Finished floor BewUon Information Pad Grads = 91~;g per plan Pad Grade + 0.7 = Oerogq FFE (915,6) Resk]enticl FFE - g.O = Bonemont Note,: The garage ~ished floor is 1.3 above the curb at the drive, per plan. Plot Plan=Legend ~ Proposed Grades 000.0 Existing Grades .-.----000.0--'-"' Contour Grade ~ ~< Approx, Lateral Location ---.--. S -~- Sanitary Sewer Lines ~t' Storm Sewer Lines water Sor~ce Lines ....... Sub-Serfoce Drain Lines ~ Manhole (seni.tory or. Storm) (~ 9eehive inle. t (Storm) I~l Curb Inlet (St. orrn) D End Section (Storm) ~. Fire Hydrant ......... Flow Line of swale - Building Line (BL / BSL) ...... Easement Uno Note: Sanitary Sewer Top of Casting Information Upstreen t~onhoie, TC= 917.40 Downstream Manhole, TC=915.30 per Ground Cover ColouloUons Drive =513 SC+ Public Walk =194 SC:I: Private Walk =94 SC+ Nydroneeding =n/a SF+ Sod = 472 SY+. from entire )ard Note: ]his drawing is based on construction plans or record drawings, and is not based upon o fie~d survey. ]he Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any conatrucUon. Any discrepancy found on this drawing should be reported to ]he Schneider Corporation tmmedictely; foiling to do so results in the contractors assumption of ail lisMJtty. Note: Per Conn~l zoning urdinonce 26.1.1: l~e residenU~ district limits height ts tweaty-flve feet (2§'), r~we~ o owellin9 may be iscressed in height to th~-flve feet (,35') provided the bide end lear ~ras ~re incresssd on eddiUesel one font (1') for each one font (1~) the structure exceeds the'Sst twesty-fiv~ rest (25') in height, Lot # 17 Vb05.0046640 Deta~ ofC~ound/Storm Weterflowpattem for Scale: 1 =30 Note: Builder to ensure positi~ drainage away from structure(s), SidewoJk to b, pla:ed t~ from prepert) line, 4 from back of curb, per plan. ~ ~914AO The basenest e~evotion, depicted hereon, hes been determined end based upon the pad grades and/er caetours taken from the construction Cons for this subdivis~. Unless stated, no infa3nation about fluctuating water tables, soil conditions, or soil types has been provided or stated on Sold ross. it L~ recommended that the basement fmnlshed floor eleveUons be ot least two feet (2') above the normol pest elevation of any adjoining bodies of w~te~, unless s study of facts reveals othorwiss. If during the exc~vethm prsosss any ground water is witnessed, ~e Schneider Corporatk)n should be notified immedistety. 1he basement e~eveUon shonld be raised two feet (2') above the 9resnd water, and additional conetmcticn techniques shculd be incorporated to alle~3te future ~)rOblems, 16' Note: Sump pump(s) to be pieced by builder as needed. FLOOD HAZARD STATEMENT CERTIFICAtiON ~:~..-'~ nO. -'..,'~'~ ~ ~ STATE OF' DA~E~