HomeMy WebLinkAbout06010029-State Release Indiana Department of Homeland Security I INDIANA 02 i
40l W. Washington St., Room E245 S~
Indianapolis, IN 46204
Available At Your Local Licence eranch
SUPPORT HOOSIER SAFETY
To: Owner / Architect / Engineer
Rowland Design tnc
Eric J Rowland 19400063
701 East New York Street
INDIANAPOLIS IN 46202
Would you like to reduce your turnaround time?
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT
efile24-7@dhs.state.in.us, Or VISIT OUR WEB SITE AT www,in.gov/dhs/osbc
Project number
CONSTRUCTION DESIGN RELEASE 315288
State Form 41191 (R9/5-98) Construction type
Report Printed on: January 3, 2006 EXST
Scope of release
ARCH ELEC
Fax & e-malt: 3172632073, erowland@rowlanddesign,com
Release date
12/30/05
Occupancy classification
Br REM
Type of release
Standard
Project name
Perficient
At Clay Terrace
Street address
41390 Clay Terrace Boulevard
City County
CARMEL HAMILTON
The plans, specifications and application submitted for the above referenced proiect have been reviewed for compliance with the applicable rules of
the Fire Prevention and Building Safety Commission The project is released for construction subject to, but Rot necessarily limited to, the conditions
listed below THIS iS NOT A BUILDING PERMIT All required local permits and licenses must be obtained prior to beginning construction work All
construction work must be in full compliance with all applicable State rules Any changes in the released ptans and/or specifications must be filed with
and released by this Office before any work is a!tered. This release may be suspended or revoked if it is determined to be issued in error, in violation
Of any rules of [he Commission or if it is b~sed on i~correct er insuffiCi6~t infom~tion, This release shall expire by fimi~ation, end become null and
void, if the work authorized is not commenced within one (1)year from the ~bo~e date,
CONDITIONS:
Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans
and specifications filed in conjunctie~ with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety
Commission Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000
in accordance with Section 19of the General Administrative Ru~es (675 lAC 12-6-19) a complete set of plans and specifications that conform
exactly to the design that was released by the office of ihe slate building commissioner shall be maintained on the construction iobsite as well as a
copy of the design retease,
3B THIS PROJECT HAS BEEN REVIEWED UNDER THE 2003 INDIANA BUILDING CODE.
4G0603AF Plans and specifications for the revised fire suppression system shall be filed with the required
application, fees, and complete details in accordance with 675 lAC 12-6- 3(a), 7(h)17 and 675 lAC
13-1-8. (NF.P.A. #13)
4G0603AM This release does not include mechanical work, Plans and specifications for adding or remodeling
this system shall be filed as a new project or as a partial before commencing work in accordance
with 675 lAC 12-6-3.
4G0603AN This release does not include plumbing work. Plans and specifications for adding or remodeling this
system shall be filed as a new project or as a partial before commencing work in accordance with
675 lAC 12-6-3.
4G0412AE The proposed building or addition may not put the existing building in noncompliance or into further
noncompliance in accordance with 675 lAC 12-4-12(f). (Remodel work may not put existing
building into noncompliance.)
3B0803A Interior finish flame-spread ratings shall comply with Section 803, Table 803.4 IBC (675 lAC 13-2.4).
4G0412AC
No addition or alteration shall cause an existing building, structure, or any part of the permanent
heating, ventilating, air conditioning, electrical, plumbing, sanitary, emergency detection, emergency
communication, or fire or explosion suppression systems to become unsafe or overloaded under
the provisions of the rules of the Commission for new construction in accordance with 675 IAC 12-4-
12(c).
Page 1/2
Would you like to reduce your turnaround time?
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT
efile24-7@dhs.stateJn,us, Or VISIT OUR WEB SITE AT www.in.gov/dhs/osbc
Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the
Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from Ihe above -
stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire
and Building Services is dosed during normal business hours In the latter case, the filing deadline will be the first working day thereafter If you
choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will
be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission If a petition for review is not filed, this Order wilt
be final, and you must comply with its requirements
Filed By Code review official
BARBARA HARRY
Address (name,title of local official,street,city,state and ZIP code
DEPT OF COMMUNITY SERVICE
JIM BLANCHARD
ONE CIVIC SQUARE
CARMEL iN 46032
Fax & e-mail: 3175712499, jbtanchard@carmel in gov
Code Enforcement & Plan Review Branch Director
Page 2/2