Loading...
HomeMy WebLinkAbout14040128 Building PlansMECHANICAL & ELECTRICAL NOTES 1. ALL MECHANICAL ELECTRICAL, PLUMBING, FIRE SUPPRESSION, AND FIRE ALARM SYSiEMS SHALL BE DESIGNED AND INSTALLED BY THE RESPECiNE DESIGN/BUILD CONTRACTORS PER AGREEMENi WITH THE OWNER. ALL TRADES SHALL DESIGN AND INSTALL THEIR RESPECTIVE SYSTEMS IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. COORDINATE WITH THE ARCHITECT IF ADDITIONAL INFORMAiION IS REQUIRED IN ORDER TO DO THE WORK IN THE FIELD. SCHOTT DESIGN WC. DOES NOT HAVE CHARGE OR RESPONSIBILITY FOR THE DESIGN OR INSTALLATION OF SYSTEMS EXECUTED AS DESIGN/BUILD WITH THE OWNER. 2 HN.A.C. WORK GENERALLY INDICATED BY THIS DRAW WG IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A FUNCTIONAL COMFORTABLE ENVIRONMENT AND A COMPLETE, WORKING SYSTEM. COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. 3. VERIFY HEAT LOADS OF ANY SPEGAL EQUIPMENT IN THE TENANT SPACE, AND PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER PRIOR TO ANY PURCHASE OF NEW EQUIPMENT. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE OFFICE SPACE TO BE ON A SPLIT ZONE UNLE55 APPROVED BY BUILDING OWNER/LANDLORD. 4. RELOCATE AIR-SUPPLY DIFFUSERS AND RETURN-AIR GRILLES AS REQUIRED. PROVIDE PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES. LOCATION OF DIFFUSERS SHOWN ON PLAN IS FOR REFERENCE ONLY. CONiRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS REQUIRED BY CODE. 5. POSIiION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OR OTHER CONFLICTS. b. ELEQRICPOWERWORKGENERALLYINDICATEDBYTHISDRAWWGIS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDEACOMPLETE,WORKINGSYSTEM. 7. COMPLY WITH THE INDIANA ELECTRICAL AND MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. 8. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. PROVIDE OR REUSE ELECTRICAL POWER AND DATA OUTLEfS AS REQUIRED. 9. ALL ELECTRICAL OUREfS WITHIN b'-0" OF WATER ARE TO BE G.EC.I. 10. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILWG TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE TERMINALS AT FACE PLATE. I1. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLEfS & SWITCHPLATES TO MATCH EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO PURCHASE. 12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN. REFER i0 THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE TENANT'S DATA VENDOR. ELECTRIQAN TO MAKE RNAL CONNECTION FROM WORKSTATION WHIP TO JUNCTION 80X. THE FURNITURE VENDOR IS TO BE RESPON518LE FOR WIRING THE BASE PANELS OF THE WORKSTATIONS. 13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING ELECTRICAL CONDUITS TO JUNCiION BO%ES. 14. ELECTRIC LIGHTING WORK GENERALLY INDICATED BY THIS DRAWING IS TO BE PROVIDED BY DESIGN/BWLD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, FUNCTIONAL SYSTEM. I5. VERIFY EXISTING LIGHiING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE E%ISTWG CIRCUIiING FOR NEW LAYOUT OF LIGHT FIXTURES. 16. ENSURE THAT ALL MOUNTWG HEIGHTS OF ELECTRICAL DEVICES MEET AD.A. REQUIREMENTS. 17. WHEREMULTIPLESWITCHESARESHOWN,PROVIDE�I�GANGBOX WITH A SINGLE COVERPLATE. 18. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWNLIGHTS, SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS UNLESS OTHERWISE NOTED. 19. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBG EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 20. PROVIDE ALARM NOTIFlCATION APPLIANCES (HORNS/STROBES�, EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEEf ALL APPLICABLE CODES �INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA�. 21. COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DEfECTION DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE WALLS (CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANT-INSTALLED ITEMS �I.E. PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS). 22 IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS W EXISTING SPACES. CONSULT WITH LANDLORD. FIRE PROTECTION NOTES THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRWKLERED FACILITIES. I. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, WG, IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRMKLER SYSTEM. 2 THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND WSTALLATION OF FIRE SPRINKLER/FIRE SUPPRESSION SYSTEMS. 3. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJEQ. 4. PROVIDE NEW OR RELOCATE EXISTING SPRWKLER HEADS AS REQUIRED. PROVIDE MISSMG COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE MSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MA%IMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO n viciai c cvriNri ucuFa GENERAL PROJECT NOTES 1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDWG CONSTRUCTION TYPE AS DEFlNED BY SECTION 601 OF THE INDIANA BUILDWG CODE . 2 ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT APPLICABLE BUILDING CODE(S� FOR THEIR RESPECTNE SCOPE OF WORK. 3. CONTRACTOR�S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE DRAW WGS CONTAWED HEREIN MAY NOT BE ALL WCWSNE OF EXISTWG CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTOR�S� SHALL MAKE THEMSEWES FAMILIAR WITH THE WORK SITE W THE FlELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK. 4. FlELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. WFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS. NOTED DIMENSIONS TAKE PRECEDENCE. 5. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY iHROUGH iHE GENERAL CONTRACTOR TO SCHOTT DESIGN, INC. 6. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL ON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS STORAGE AND HANDLING, DELNERIES, ACCE55 TO iHE WORK SITE, TRAFFlC CONTROL, AND BUILDWG/PUBLIC SAFETY PROCEDURES DURWG CONSTRUCTION. THE CONTRACTOR SHALL AL50 COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE. 7. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURING HOLIDAYS. LANDLORD RESERVES THE RIGHT i0 RESTRICT CONSTRUCTION TO NIGHTS AND WEEKENDS WHEN THAT CONSTRUQION IS DEEMED TO MTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS. 8. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEETTHE PROJECT SCHEDULE. THE OWNER, TENANT, OR DESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRAQOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES. 9. SUBSTIiUTIONS FOR SPECIFICALLY NAMED PRODUCiS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH APPROPRIATE SUPPORT WFORMATION TO THE DESIGNER. ALLOW REASONABLY SUFFICIENTTIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DEQSION. 10. SCHOTf DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS, SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINWG A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES. 11. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP PROCEDURES AND GUIDELWES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT. 12. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNAiED AREAS SHALL BE USED BY CONSTRUCTION CREWS. 13. iHE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF DAILY TENANT OPERATIONS DURWG DEMOLITION AND CONSTRUCTION WORK. DUST PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS @ 24"O.C., INSULATION AND 6 MIL VAPOR BARRIER ON EACH SIDE. 14. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FlELD, CONFLICiS ARE DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAW WGS. Q.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FlXTURES AS INDICATED ON THE CEILWG PLAN�. I5. SCHOTi DESIGN, INC., IS NOT RESPONSIBLE FOR THE IDENTIFlCAiION, DISCOVERY, PRESENCE HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE. 16. PROVIDE FlRETREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALLSTOPS, CABINETRY, EfC. 17. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITfED TO SCHOTf DESIGN, MC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAW INGS, OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. FINISH NOTES 1. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 �INTERIOR FINISHESf OF THE INDIANA BUILDWG CODE FOR CLASS A FlRE RATINGS. 2 FOR ALL NEW DRYWALL WSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM ASSOCIATION. �SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASiENERS, TAPING DETAILS, CORNER BEADS, ETC.) 3. ALL NEW PLATES AND SWITCHES ARE TO MATCH EXISTING COLOR, UNLE55 OTHERWISE NOTED. REMOVE ALL PLATES BEFORE PAINTING AND REATfACH AFTERWARDS. CONTRACTOR TO CONFlRM EXISTWG COLOR PRIOR TO PURCHASING NEW. 4. ALL AREAS RECEIVING PAINT ARE TO RECENE PRIMER COAT AND TWO (2� FlNISH COATS. 5. FOR CHANGE W FLOOR FlNISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS TO MATCH VINYL BASE COLOR (IE: WHERE VCT MEETS CARPET�. b. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PARi OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FlNISHED PRODUQ READY FOR TENANT AND BUILDING OWNER. 7. REFlNISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED. 8. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FlNISH. 9. SUBMIT FINISH SAMPLE OF MILLWORK �STAINED OR PAINTED AS SPECIFIED� TO SCHOTf DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL MILLWORK. 10. REFERENCE INTERIOR ELEVATION d SECTIONS WHERE PROVIDED FOR ADDITIONAL FlNISH W FORMATION. 11. ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT. 12. ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT MANUFACTURER. 18. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF MATERIALS AND EQUIPMENT. 19. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURWG THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL STATE, AND LOCAL BUILDWG CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. 20. ALL DEfAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FlRST APPROVAL BY SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER. 21. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT 8E APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. 22. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT ATTACHED TO THE BUILDMG ARE FOR REFERENCE ONLY AND ARE NOTTO BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED. 23. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS. 24. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE FOR FINISH. 25. ALL MECHANICAL ELECTRICAL, PLUMBING, FIRE SUPPRESSION, AND FIRE ALARM SYSTEMS SHALL BE DESIGNED AND INSTALLED BY THE RESPECTIVE DESIGN/BUILD CONTRACTORS PER AGREEMENT WITH THE OWNER. ALL TRADES SHALL DESIGN AND INSTALL THEIR RESPECTNE SYSTEMS IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. COORDINATE WITH THE ARCHITECT IF ADDITIONAL INFORMATION IS REQUIRED IN ORDER TO DO THE WORK IN THE FIELD. SCHOTT DESIGN, INC. DOES NOT HAVE CHARGE OR RESPONSIBILITY FOR iHE DESIGN OR INSTALLATION OF SYSTEMS EXECUTED AS DESIGN/BUILD WITH THE OWNER. 26. WHEN REQUIRED BY STATE BUILDING CODE, THE CONTRACTOR�S) SHALL PROVIDE DESIGN/BUILD DRAWINGS FOR MECHANICAL, PLUMBING, ELECTRICAL, OR FIRE SUPPRESSION. DRAW WGS SHALL BE CERTIFlED BY A LICENSED ENGMEER AND SUBMITfED BY THE CONTRACTOR FOR STATE DESIGN REVIEW. 27. ALL EQUIPMENi AND/OR FlXTURES SHALL BE INSTALLED W SiRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. 28. E%ECUTE A THOROUGH FlNAL CLEAN AND INSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, RXTURES, AND EQUIPMENTSHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCE 5 WORK & DO NOT LEAK. 29. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF iHE PROJECT. 30. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL DO NOT SCALE DRAWINGS. WRITfEN DIMENSIONS GOVERN. 31. CONiRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING E%ISTING WINDOW BLINDS. REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDING STANDARD. 32. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE W THE OWNER/CONTRACTOR AGREEMENT. 33 FlRE SEAL ALL PENEfRATIONS THROUGH RATED WALLS, ROORS, AND CEILINGS WITH APPROVED FIRE-RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS. 34. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FlRE RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FlTTIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED. 35. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEW CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED. MILL/CASEWORK NOTES DEMOLITION NOTES 1. COORDINATE DEMOLITION WITH NEW WORK CONSTRUCTION DRAWINGS IN ORDER TO DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. SALVAGE REUSABLE ITEMS. 2. NO STRUCTURAL OR LOAD-BEARING CONSTRUCTION SHALL 8E REMOVED, DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. PROTECTALLEXISTINGSTRUCTURALMEMBERSDURINGDEMOLITION/CONSTRUCTION. THE CONTRAQOR SHALL VERIFY IN THE FlELD, PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT STRUCTURAL CONTACT SCHOTf DESIGN IMMEDIATELY IF THE CONTRACTOR(S� IN THE RELD SUSPECTTHAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR OTHERWISE LOAD-BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THAT MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL EXERQSE CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENT i0 OR AROUND STRUCiURAL MEMBERS. THE CONTRAQOR IS SOLELY RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM. 3. PRIOR TO DEMOLITION, COORDINATE WITH THE OWNER IN THE FlELD REGARDMG THOSE ITEMS THAT MAY BE REMOVED AND REUSED. CONFIRM WITH THE OWNER THOSE ITEMS THE OWNER CHOOSES TO REfAIN FROM DEMOLITION, AND THOSE ITEMS OF WHICH THE OWNER CHOOSES TO DISPOSE. COMPLY WITH THE OWNER'S REQUESTS. 4. WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY OWNER. 5. REMOVE ALL E%ISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR DASHED LWES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION PLAN. VISIT AREA OF WORK TO ASSURE EXTENT OF DEMOLITION. b. REMOVE ALL CARPET, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FlNISHES AS REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FlELD VERIFY EXISTING CONDITIONS. REFER TO FlNISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING FINISHES TO REMAIN. I. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWMGS ARE TO BE PROVIDED UNDER THE GENERAL CONTRACT. 2 UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE (A.WJ.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK. 3. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION. 4. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON PLANS AGAINST DIMENSIONS OF AS-BUILT CONDITIONS W FlELD. REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS. 5. VERIFY FlNISHES (LAMINATE, VENEER, STAINS, ETC.� ON THE SECTIONS AND ELEVATION DRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES. IMMEDIATELY REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. 6. REFER TO MILLWORK SECTIONS & ELEVATIONS . UNLESS OTHERWISE SHOWN, PLASTIC LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED. BACKSPLASHES TO BE FIELD APPLIED. 7. REFER TO MILLWORK SECTIONS & ELEVATIONS FOR CABWETRY SPECIFlCATIONS (CUSTOM PLAS➢C LAMINATE OR PREMANUFACTURED STOCK CABMETRY�. 8. TO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND CABMEfRY WHERE SPEQFlED. ALL WOOD BLOCKING TO BE FlRE RATED. DOCUMENT APPROVAL 7. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED. SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION. 8. REFER TO DEMOLITION PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING GRID INSTRUCTIONS. 9. USE CARE TO PROTECT EXISTWG BUILDING ELEMENTS INDICATED ON THE DRAWINGS TO REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES. THE CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S COST, ANY SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISE BEEN REASONABLY PROTECTED AND MAINTAMED IN GOOD CONDITION FOR THE OWNER'S USE IN THE PROJECT. 10. PER THE INDIANA ELECTRICAL CODE �SPREAD OF FIRE OR PRODUCTS OF COMBUSTIONJ REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDWG BUT NOi LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FlRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FlBER OPTIC CABLES/RACEWAYS, AND PLTC CABLES. REFER TO SECTION 30021. I I. WHERE FlXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBMG, MECHANICAL OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND GOVERNING SAFEfY REGULATIONS OR PROCEDURES. MARK, LABEL, OR FLAG ALL TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE AN "AS-BUILT" SEi INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS. 12 GENERAL CONTRACiOR TO PROVIDE RECYCLING COSTS TO THE BUILDING OWNER/LANDLORD ON ALL ITEMS BEWG DEMOLISHED, SUCH A5, METAL STUDS, DRYWALL, CARPET, CEILWG TILES, DOORS,GLASS, AND CAB W ETRY. LOCATION .,� � . ...,,�� ' .,. . � � .�.w�,� o..,� �._ �,,,,,.o.�.�..�.,, � , �� � ' .,,.,., r ,��.�, �..�..� w... o' , «>,�. ..ou.., .,�.,. ... ' �.M.. .�,,, wz.,. ,.n�.,� �..�.,. �[.-'�v��.,� ..., VICINITY MAP � NOT TO SCALE N KEY PLAN - 2ND FLOOR /�i NOTTO SCALE INDEX OF DRAWINGS Tl l l COVER SHEET AND GENERAL PROJECT NOTES LI00 LIFESAFETYPLAN Al l l DEMOLITION PLAN 8 ARCHITECTURAL FLOOR PLAN � AI21 REFLECTED CEILWG PLAN: HVAC / LIGHTWG / ELECTRICAL PLAN A211 DOOR SCHEDULE / INTERIOR DETAILS / FINISH PLAN A212 RECEPTION DESK DETAILS � � Q � � � � � � � � U � � C C � � O � � � � � � � _ � � O pi� �� o_ � U om� '^ � ?< _ S � �Qw3 THI$ DRAW WG, AND iHE IDEAS, DESIGN$ AND CONCEPT$ CONTA W ED HEREIN, ARE THE E%CWSNE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, MC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOl1TTHE WRITfEN CONSENT OF $CHOTT DESIGN. � N a N Z c� Q` O / � � � � � Z W"- � � w W C � L � Z Q �U r � r r SET I� 0. AR10700017 STATE OF PROJECT NUMBER 20�4.�44 )J. MGR DRAWN BY ACM ACM 2ND FLOOR COVER SHEET AND GENERAL NOTES T111 DEMOLITION LEGEND EXISTING TO BE REMOVED I EXISTING TO REMAIN ______ WALL c/ � DOOR AND FRAME _�-�- WINDOW/SIDELIGHT �i -� CEILING GRID AND 7____Jr TILES, 2x4' �i ; � CEILING GRID AND 7—r--�r TILES, 2'x2' F-i �::� SUPPLYAIRDIFFUSERS �_y c_:s_a ��"�� LIGHT FlXTURE, �L __ J� FLUORESCENT, 2'x4' �-� ucr+r FixruRE. L_J FLUORESCENT,2'x2' �I IJGHT FI%TURE, CAN ��' �-ti� LIGHT FIXTURE, TRACK rk LIGHT FIXTURE, SCONCE LIGHT H%TURE, � PENDANT � LIGHTSWITCH <9 EXIT LIGHT �� -� ELECTRIC OUTLET(S� �8:��:��i DAiA OR ��� COMMUNICATION OUTLET WALL � DOORANDFRAME x WINDOW/SIDELIGHT NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. DEMOLITION PLAN NOTES D01 REMOVE EXISTING CABW ETRY AND COUNTERTOP. D02 REMOVE EXISTING RECEPTACLE AS SHOWN. PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED. D03 REMOVE EXISTING CEILING GRID, TILES, DIFFUSERS AND LIGHTS THROUGHOUT. � AREA NOT IN CONTRACT ❑ AREA OF WORK DEMOLITION PLAN 0 4' 8' 16' WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE W2 UNLESS OTHERWISE NOTED. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. W� STANDARD WALL � 35/g " MEiAL STUDS AT 16" O.C.; ONE LAYER OF 5/q" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING WZ STANDARD WALL WITH INSULATION � 35/g " METAL STUDS AT 16" O.C.; ONE LAYER OF 5/a' TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILMG FlBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL A80VE CEILING W3 STANDARD DEMISING WALL TO DECK �� 35�g" MEfAL STUDS AT I 6" O.C.; � ONE LAYER OF 5/g" TYPE "X" GYPSUM BOARD � EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FlBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" SOUND BATT INSULATION EACH SIDE OF WALL ABOVE CEILING. W4 DEMISING WALL WITH SECURITY MESH .� 3%g"METALSTUDSATI6"O.C.; � � � ONE LAYER OF a" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILWG FlBERGLA55 SOUND BATf INSULATION INSIDE WALL AND 2'-0" SOUND BATf INSULATION EACH SIDE OF WALL ABOVE CEILING; PROVIDE METAL SECURITY MESH ON TOP OF WALL ABOVE CEILING TO DECK ARCHITECTURAL LEGEND NEW CONSTRUCTION � WALL W� �v WINDOW/SIDELIGHT #� DOORANDFRAME (SEE DOOR SCHEDULE� EXISTING TO REMAIN — WALL �a WINDOW /SIDELIGHT NH DOORANDFRAME NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. GENERAL NOTES 1. SEE ELECTRICAL PLAN ON SHEET A121 FOR INTENDED FURNITURE LAYOUT. ARCHITECTURAL PLAN NOTES A01 ALIGNFINISHEDWALLSURFACES. PROVIDESAMETHICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE W LWE WITH E%ISiING WALLS. OPROVIDE PLYWOOD PHONE BOARD, 4'x8'xq", PAINTED WITH FIRE AQZ REiARDANi PAINT TO MATCH ADJACENT WALL FlNISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. A03 NEWRECESSEDWALLCABWETHREE%TWGUISHERTOBE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FlRE EXTMGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. A�q CONFlRM W FlELD IF E%ISTWG WALL MATCHES WALLTYPE"W3". IF NOT, CONSTRUCT WALLTO MATCH WALLTYPE"W4". PROVIDE �2� 4'W X 8'H WINDOWS IN CONFERENCE ROOM WITH A05 71MELY ALUMATONE FRAMES. Ao6 PROVIDE BLOCKING IN WALL FOR OWNER PROVIDED FLAT SCREENTV. A07 PROVIDE ALTERNATE PRICE FOR FULL WIDTH BUTf-GLAZE GLASS WITH TIMELY AWMATONE FRAME, W LIEU OF 24" SIDELITE. CLEAR CAULK JOINTS. P01 PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASiE AND VENT PIPING FOR SWKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. PQZ PROVIDE WATER LINE FOR DISHWASHER, COFFEE AND REFRIGERATOR. CONFIRM LOCATION WITH TENANT. � AREA NOT IN CONTRACT ❑ AREA OF WORK ARCHITECTURAL PLAN " 0 4' 8' 16' � v O O U � � C � � O � � N � � � O pi� �� o_ � U �mC7 � ? � < p S �Qw3 THI$ DRAW WG, AND iHE IDEAS, DESIGNS AND CONCEPT$ CONTA W ED HEREIN, ARE THE E%CWSNE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, MC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOl1TTHE WRITfEN CONSENT OF $CHOTT DESIGN. � N Z c� Q` O / � J � � � Z W"- � � w W C � L . �/ Z Q �U � � � � SET I� 0. AR10700017 STATE OF PROJECT NUMBER 2014.144 )J. MGR DRAWN BY ACM ACM 2ND FLOOR DEMOLITION PLAN, ARCHITECTURAL FLOOR PLAN Alll ELECTRICAL LEGEND NEW CONSTRUCTION I EXISTING TO REMAIN � POWEROUTLET,DUPLE% �POWEROUTLET, QUADRUPLEX � JUNCTION BOX �CEILING MOUNTED JUNCTION BO% � BO%, BLANK COVER PLATE � BOX,OPEN p POWER POLE FOR � ELECTRICAL AND DATA. PROVIDE JUNCTION BO% ABOVE CEILMG. FLOOR BOX WITH POWER �� AND DATA, FLUSH MOUNTED FLOOR BO% WITH � q JUNCTION BOX AND DATA, FLUSH MOUNTED DATA/COMMUNICATION � OUTLET (PROVIDE BO% AND PULL SiRING ONLY� DED DEDICATED CIRCUIT GFCI GROUND FAULT CIRCUIT IMERRUPT OUTLET +44" HEIGHT OF ELECTRICAL OR DATA DEVICE � POWER OUTLET, DUPLEX � POWEROUTLEi, QUADRUPLEX � JUNCTION BOX O CEILING MOUNTED JUNCiION BOX � BOX, BLANK COVER PLATE �0 BO%,OPEN 0 POWER AND DATA POLE FLOOR BOX WITH POWER �I� AND DATA, FLUSH MOUNTED FLOOR BO% WITH �J IQ JUNCTIONBOXAND DATA, FLUSH MOUNTED � DATA/COMMUNICATION OUTLET GENERAL NOTES: ALL OUTLETS ARE TO BE INSTALLED 18" MIN. AEE TO THE CEMER OF THE DEVICE PER ADA GUIDELWES UNLESS NOTED OTHERWISE. REFER TO DOOR SCHEDULE AND COORDINATE WITH OWNER/OWNER REGARDING JUNCTION BO%LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES AND CARD READERS. ELECTRIC STRIKES AND CARD READERS ARE TYPICALLY INSTALLED 8Y THE OWNER'S SECURITY CONTRACTOR AND ARE TYPICALLY NOT SPECIFIED BY SCHOTf DESIGN, INC. ELECTRICAL PLAN NOTES E01 COORDINATE COPIER RECEPTACLE WITH OWNER. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. EaZ PROVIDE JUNCTION BOX AND DATA FOR OWNER'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH OWNER'S FURNITURE VENDOR. E03 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX MSET INTO CABINET/ WALL FOR OWNER'S MICROWAVE, CENTERED AT 60" ARF. PROVIDE RECESSED ELECTRICAL, DATA, AND CABLE OUTLEf 60" E04 AF.F. AND CORE AT FLOOR IN WALL FOR OWNER PROVIDED FLAT SCREEN MONITOR. COORDINATE WITH OWNER ON EXACT LOCATION. E05 PROVIDE JUNCTION BOX AS REQUIRED FOR OWNER SUPPLIED ADA HEIGHT DISHWASHER. E06 COORDINATE WITH OWNER ON EXACT ELECTRICAL REQUIREMENTS IN SERVER ROOM. E07 PROVIDE FWSH MOUM ROOR CORE FOR ELECTRICAL AND DATA. COORDINATE EXACT LOCATION WITH OWNER AND MILLWORK VENDOR FOR CUSTOM BUILT RECEPTION DESK. � AREA NOT IN CONTRACT ❑ AREA OF WORK ELECTRICAL PLAN 0 4' 8' 16' CEILING LEGEND NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, 2'x4' FLUORESCENT, PARABOLIC ❑LIGHT FIXTURE, 2'x2', FLUORESCENT. PARABOLIC O LIGHT FIXTURE, 1'x4', FLUORESCENT, PARABOLIC � LIGHT FIXTURE, 1'x4', FLUORESCENT, INDIRECT �LIGHTFlXTURE, TRACK � RECESSEDLIGHTFIXTl1RE � WALLSCONCELIGHT FlXTURE � LIGHTFIXTURE, PENDANT NL INDICATES NIGHT LIGHT LOCATION � EXITLIGHTFIXTURE EMERGENCY LIGHT FIXTURE �N LIGHTSWITCH �N3 LIGHTSWIiCH,3WAV �N4 LIGHTSWIiCH,4WAV �ND LIGHTSWITCH,DIMMER i — � LIGHT QRCUIT �CEILING GRID, SUSPENDED,2'x4' �CEILING GRID, SUSPENDED,2k2' CEILING GRID, Sl1SPENDED, 4'x4' TEES i0 COMPLETE GRID ❑GYPSUM BOARD CEILING EXISTING/RELOCATED DIFFUSER,LAY-IN,2x2 � EXISTING/RELOCATED DIFFUSER, LAY-IN, I'x4' � EXISTING/RELOCATED DIFFUSER, LAY-IN. 4'k4' � EXHAUST FAN, 2'x2' �LIGHT FlXTURE, 2x4', FLUORESCENT, PARABOLIC �LIGHT FIXTURE, 2'x2', FLUORESCENT. PARABOLIC O LIGHT FIXTURE, 1'x4', F W ORESCENT, PARABOLIC �� LIGHTFIXTURE,lk4', F W ORESCENT, NDIRECT �LIGHiHXTURE TRACK � RECESSED LIGHT FIXTl1RE � WALL SCONCE LIGHT FlXTURE � LIGHiFIXTURE, PENDANT INDICATES NIGHT LIGHT LOCATION � EXR LIGHT FIXTURE � EMERGENCV LIGHi FlXTl1RE � LIGHTSWITCH �3 LIGHTSwITCH,&WAY �4 LIGHiSWITCH,4-WAY �p LIGHTSWITCH,DIMMER : --�� LIGHTQRCUIT �i i� CEIUNGGRID, � �i SUSPENDED,2'x4' �i__ i __i�_ CEIUNG GRID, � �i �i SUSPENDED, 2'x2' Ji_____i�_ �i �i CEILINGGRID, i i Sl1SPENDED.4'x4' �_____�r_ � DIFFUSER. LAY-IN, 2'�2' � DIFFUSER LAY-IN, I'x4' � DIFFUSER,LAY-IN,4"x4' � E%ISTING EXHAUST FAN, 7x2' NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILWG ➢LES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. GENERAL NOTES 1. PROVIDE NEW Zx2 GRID AT 9'-0" A.F.F. TILES ARE 2x2 ARMSTRONG DUNE REVEAL EDGE LAY W➢LES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. PROVIDE EMERGENCY LIGHTING IN OWNER SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAWS 50 PERSONS OR MORE. FlXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 3. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY-OUT AND TOTAL WATfAGE MEETS ASHRAE 90.1 STANDARDS. OVER 50%OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 4. UNLESSNOiEDOTHERWISE,ALLNEWSWITCHESMUSTBEAN OCCUPANCY SENSOR COMBO UNIT WITH BOTH MICROPHONIC AND WFRARED TECHNOLOGY WITH A ONE BUTfON OVERRIDE. OCCUPANCYSENSORSARETO BELOCATEDSUCHTHAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILWG MOUMED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 5. PROVIDE ALTERNATE PRICE FOR AVANTE INDIRECi/DIRECi 2%4 FLUORESCEM Fl%TURES M LIEU OF PARABOLIC FlXTURES. 'RELOCATE DIFFUSER$ 8 FLE%DUCT IF REQUIRED VAV/ EXISTING VAV BOXES/HEAT PUMP AND MAIN SUPPLY DUCT$ TO REMAIN MECHANICAL DIFFUSER RELOCATION "REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION MECHANICAL NOTES I. SCOPE MTENT IS FOR EXISTING MECHANICAL SYSTEMS TO REMAIN. 2 EXISTING REX DUCT AND DIFFUSERS BEING RELOCATED AS NECESSARY PER WALL LAYOUT. NO MAIN DUCTWORK BEING RELOCATED. 3. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR NOTIFYING APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED. REFER TO MECHANICAL NOTES ON SHEET Tl I I. PLAN NOTES R01 CONTROL OPEN OFFlCE AREA LIGHTING AND WORK/COFFEE AREAWITH3-WAYSWITCHATTHISLOCATION. PROVIDEMULTIPLE SWITCHES AS REQUIRED. COMPLIANCE WITH INDIANA ASHRAE 90.1 ENERGY CODES IS RESPONSIBILITY OF ELECTRICAL CONTRACTOR AND/OR DESIGN BUILD CONTRACTOR. R02 CONTROL DECORATIVE PENDANT IN RECEPTION AREA WITH SWITCH ATTHIS LOCATION. R03 PAINT THIS PORTION OF DRYWALL BULKHEAD PiS. THIS INCLUDES VERTICAL PLANES. SEE SPECIFlCATION ON SHEET A211. VERTICAL PLANES TO EXTEND TO 9'-0" AFF. BOTfOM FACE OF BULKHEAD TO BE AT 8'-0" AFF. R04 PAINT THIS PORTION OF DRYWALL PT6. SEE SPEQFlCATION ON SHEEfA211. ROS CONTROL LED DOWNLIGHTS WITH DIMMER SWITCH ATTHIS LOCATION. R06 CONTROL PENDAM FlXTURES WITH SWITCH AT THIS LOCATION. u v O O U � � C C � � O � � N � � � O pl��s a� N o m � � � � �Qw3 THI$ DRAW WG, AND iHE IDEAS, DESIGNS AND CONCEPT$ CONTA W ED HEREIN, ARE THE E%CWSNE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, MC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOl1TTHE WRITfEN CONSENT OF $CHOTT DESIGN. � N Z c� Q` O / � � � � � Z W"- �Zw W C � L Z Q �U r � r r SET I� 0. AR10700017 STATE OF PROJECT NUMBER 2014.144 )J. MGR DRAWN BY ACM ACM 2ND FLOOR ELECTRICAL PLAN/ REFLECTED CEILING PLAN A121 LEGEND FLOOR COVERINGS CARPET CPTi MFG: TBD TYPE -- PATTERN: TBD COLOR: TBD CPT2 MFG:TBD _ TYPE: PATfERN: TBD COLOR: TBD CERAMIC TILE CTi MFG: TBD SIZE: 12"x12" COLOR: -- GROUT: — VINYL COMPOSITION TILE/LU%URY VINYL TILE vCTi MFG. TBD SIZE: 12"x12" PATTERN: --- COLOR: --- LVTI MFG: TBD SIZE: 12"x12" PATTERN: --- COLOR: — WALL BASE vg MFG: TBD TYPE: 4" VINYL COVE, ya' GAUGE COLOR: TBD WOOD BASE WB� SIZE: 4" TYPE: TBD PAINT / WALLCOVERING PT� MFG: TBD TYPE: LATEX COLOR: FlNISH: EGGSHELL PTZ MFG TBD TYPE: LATEX COLOR: FINISH: EGGSHELL PT3 MFG: TBD TYPE: LATEX COLOR: FlNISH: EGGSHELL PTa MFG: TBD TYPE: LATEX COLOR: FINISH: EGGSHELL PTS MFG: TBD TYPE: LATEX COLOR: FlNISH: FLATCEILWGPAINT PT6 MFG: TBD TYPE: LATEX COLOR: FINISH: FLAT CEILING PAINT W�� MFG: TBD TYPE: VINYL PATTERN: — COLOR: -- PLASTIC LAMINATE / SOLID SURFACE/QUARTZ Pu MFG: TBD co�oR: -- PL2 MFG. TBD COLOR: — SS1 MFG: TBD CD�OR: — QZ� MFG: TBD COLOR: -- MISCELLANEOUS MFG: TBD GTl C����i: -- PATTERN: — MFG: MAPLE WOOD VENEER W�� COLOR: STAINEDTO MATCH WOOD DOORS PATTERN: QUARTER-CUT MAPLE 'SUBMITSAMPLE FOR SDI APPROVAL CASEWORK NOTES PLAN NOTES F01 PROVIDE ZWC TERRARO STRIP AT TILE TO CARPEf TRANSITION. PROVIDE LEVELING LATEX UNDER CARPEf AS SUCH THAT TOP OF CARPET PILE IS LEVEL WITH TOP OF TILE. SEAM SEAL CARPET EDGES. Fa2 PROVIDE JOHNSONITE SLIMLINE TRANSITION STRIP AT CARPETTO VCTORCARPETTOLVTTRANSITION. (COLORTBD.� F03 SEAM SEAL CARPET TRANSITION WHERE CPT 1& CPT 2 MEET AT CURVED TRANSITION. F04 TERMINATE WALLCOVERING AT THIS POINT. CONTINUE WITH PAINT AS NOTED. FOS TERMINATE WOOD BASE AS SHOWN ON PLAN. CONTINUE WITH VBl AS NOTED. F06 EXTEND WOOD BASE AT END OF WALL ENOUGH TO CATCH EDGE OF VINYL BASE W (CORRIDORJ. FQ� REFERENCESHEETAI2IFORLOCATION,SREANDPAINT DESIGNATIONS OF DRYWALL BULKHEAD. CURVE OF FLOOR FlNISH TRANSITION MUST ALIGN WITH CURVE OF F08 WALLASSHOWN. DESIGN IMENT IS FOR CURVED CARPET TRANSITION TO TERMINATE F09 AT THIS CORNER. CONSULT WITH SDI IF RADIUS DOES NOT ALLOW THIS TO HAPPEN. HARDWARE LEGEND c� c�oseR CH COATHOOK CR CARD READER BY TENANT (N.I.C.) DB DEADBOLT ES ELECTRIC STRIKE BY TENANT (N.LC.� H HOLD OPEN KP KICK PLATE KS KICK STOP OL OFFlCE LOCKSET PH PANIC HARDWARE PL PRIVACY LOCKSET PP PUSH/PULL PS PASSAGE LATCHSET PV PNOTHWGE RL ROLLER LATCHES SL STOREROOM LOCKSET TS TOPSTRIKES 1. PROVIDE A.W.L CUSTOM GRADE, FLUSH-OVERLAY CABINETS. FABRICATE WITH PLASTIC LAMINATE (PLI � COVERED M.D.O. BOARD WITH #8000-41N. CKP BRAND PREMIUM SERIES STAINLESS STEEL BAR PULL COORDINAiE WITH ELEVATIONS FOR QUANTITIES. � AREA NOT IN CONTRACT ❑ AREA OF WORK NE W PLHSiIC LHMINAiE WALL CABINEiS �SEE CASEW ORK NOiE I � NEW 25" DEEP SOLID SURFACE �SSI f COUMERiOP WITH a" HIGH BAIXSPLASH FINISH PLAN I � � I 2, 6�� 2� 6. 2, 6. J______����___ _ -d�____ ---� _ NEW PLASiIC IAMINAiE �� � BASE CABMEiS �SEE CASEW ORK NOiE I � I. 3�_��� � 2�6�� �. � � ELEVATION - WOR � �� �I II I � 2 6.. DOOR SCHEDULE NUM. 01 02 03 Oa OS 06 07 08 09 10 �� 12 DIMENSIONS 3�_p��x8�_���x � a� 3�_p��x8�_���x � a� 3�_p��x8�_���x � a� 3�_p��x8�_���x � a� 3�_p��x8�_���x � a� 3�_p��x8�_���x � a� 3�_p��x8�_���x � a� 3�_p��x8�_���x � a� 3�_p��x8�_���x � a� 3�_p��x8�_���x � a� 3�_p��x8�_���x � a� 3�_p��x8�_���x � a� DOORS FRAME TYPE MATERIAL FINISH TYPE MATERIAL FINISH D2 MATCH BLDG SEE REMARK F3 TIMELY ALUMATONE STANDARD D2 MOHAWK TBD F2 TIMELY ALUMATONE Dl MOHAWK TBD R TIMELY ALUMATONE Dl MOHAWK TBD R TIMELY ALUMATONE Dl MOHAWK TBD R TIMELY ALUMATONE Dl MOHAWK TBD F2 TIMELY ALUMATONE Dl MOHAWK TBD F2 TIMELY ALUMATONE Dl MOHAWK TBD F2 TIMELY ALUMATONE Dl MOHAWK TBD R TIMELY ALUMATONE Dl MOHAWK TBD F2 TIMELY ALUMATONE Dl MOHAWK TBD F2 TIMELY ALUMATONE MATCH BLDG Dl __. __ .__ SEE REMARK R TIMELY ALUMATONE DOOR/FRAME NOTES SET OL, CL CL PS OL OL PS PS PS SL, CL OL PS SL, CL 1. PROVIDE NEW MOHAWK DOORS, COLOR: TBD. PRE-MACHINE 5. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE NEW DOORS FOR CYLINDRICAL LOCKSETS. SPECIFlCATION, PURCHASE, AND WSiALLATION OF ALL ACCESS CONTROLLED ELEQRONIC AND/OR MAGNETIC HARDWARE AND 2. PROVIDE NEW HARDWARE ON ALL DOORS. FOR NEW DOOR ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS HARDWARE, PROVIDE BUILDING STANDARD BRUSHED ALUMINUM, MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, GRADE 2 MINIMUM. PROVIDE ADA. ACCESSIBLE LEVER HANDLES MEANS OF EGRESS. ON NEW LOCK AND LATCHSETS. 6. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: 3. FRAME ALL DOOR ROUGH OPENWGS 4" FROM ADJACENT . 7'-0" HT. TO HAVE 3 HINGES WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN. . GREATER THAN 7'-0" IN HT. TO HAVE 4 HWGES . FlNISH TO MATCH HARDWARE SET 4. REFER TO TENANT AND LANDLORD FOR KEYWG REQUIREMENTS AND LOCKSETS. 7. PROVIDE �1J SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OiHERWISE NOTED. 8. PROVIDE WALL STOP �FLOOR STOP WHERE APPLICABLE) AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL STOP. � _ ro exisrmc $iACK � u''Yd'v. I ��� �x i .� ' `� i I I I � : I I � ,�/ I i iyz°.—�' I �Exis* swK I ° v z�w. �i � I NOiF. REFER ID FLOORPLAN /� � ' � � nNO CrsavozK �vnnoNs Fore SiNK �OCnnONS. ��w. J/ � w. e,cisrl\-.-. ro 4�� BUILDING DRAIN � RISER DIAGRAM A211 TYPICAL ALL SINGLE LOCATIONS � 2�• �` � ��-0�, � 2L� � 2�-0�, � 3�-0.. � 2.��� COFFEE 213 � ELEVATION - WO 0 1' 2' 4' � 13'-10" �. 3�_Q�. �, 3�_g�. ,� 2._$.. �, 3�_g�. .� REMARKS RI RL STAIN TENANT SIDE OF DOOR TO MATCH SUIiE STANDARD SiAIN COLOR. STAIN CORRIDOR SIDE OF DOOR TO MATCH BUILDWG RZ STANDARD STAIN COLOR IN PUBLIC CORRIDORS. R2 PROVIDE48"ROCKWOODPULLRM3302STAWLESSSTEELFlNISH. PROVIDE CONCEALED CLOSER IN DOOR HEADER. f•7 F3 NEw WALLCABWEfS ISEE CASEW ORK NOiE I � SINGLE BOWLSINK, IJ"W x 19"D, GOOSENECK FAUCEi, LEVER NE W 2J" DEEP SOLID SURFACE �SSI � COOMERTOP WITH4"HIGH BACKSPLASH. NEW BASE CABW EiS �SEE CASE WORK NOTE 1 f COFFEE 213 0 1' 2' 4' � b u ��. � �K � �K� D2 D1 DOOR TYPES F2 FRAME TYPES NEW WALLCABINEiS �SEE CASE WORK NOiE 1 � Fl NEW Y4" DEEP SOLID SURFACE (SSl � COOMERiOP WIiH 4" HIGH BACKSPLASH. NEW BASE CABMEiS �SEE CASEWORK NOiE I � � 26 * ELEVATION - WORK/COFFEE 213 0 1' 2' 4' � � � � � v O O U � � C � � O � � N � � � � pl��� a� N o m � � � � �Qw3 THI$ DRAW WG, AND iHE IDEAS, DESIGNS AND CONCEPT$ CONTA W ED HEREIN, ARE THE E%CWSNE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, MC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOl1TTHE WRITfEN CONSENT OF $CHOTT DESIGN. � N Z c� Q` O / � � � � � Z W"- �Zw W C � L . �/ Z Q �U � � r r SET IVO. AR10700017 STATE �F PROJECT NUMBER 20�4.�44 OJ. MGR DRAWN BY ACM ACM 2ND FLOOR FINISH PLAN/ DOOR SCHEDULE INTERIOR DETAILS A211 ENLARGED PLAN - RECEPTION DESK 0 1' 2' 3' P`: � �m � �_ ;o o :o Fi � � ro v I,._4.. � M NEW QUARR (QZI� TRANSACTION TOP ON �3� 2" DIA. STAINLESS STEEL STANDOFFS 5'-0" �-�8 WRAPMAPLEWOOD VENEER (WDI) AROUND TOP AND SIDES OF DESK NEW MOSAIC GLASS TILE (GTl � MAPLE WOOD VENEER �WDI) STAW LESS STEEL TOE KICK b._�8, ELEVATION - RECEPTION DESK 0 1' 2' 3' r1.: � NEW QUARTZ �QZ1J TRANSACTION TOP ON (3) 2" DIA. STAINLESS STEEL STANDOFFS WRAP MAPLE WOOD VENEER�WD1�AROUND TOP AND INSIDE FACE OF DESK 24"D PLASTIC LAMINATE (PL2) WORKSURFACE. PROVIDE (2) WHITE PLASTIC GROMMETS. PROVIDE Sl1PPORTS AS REQUIRED. STAW LESS STEEL TC�F Kir'K (WDI � SEE HARDWARE NOTE ELEVATION — RECEPTION DESK EDGE OF WOOD FRAMING SEEN BEYOND INSET TILE SUBSTRATE WITH WOOD VENEER �WDI) � �� � o ,� 2� a� � ^ �. ;o o :o M N m SUBSTRATE WITH WOOD VENEER �WDI� PLASiIC LAMINATE WORKSURFACE (PL2�. PROVIDE RAKKS EH-1818 �" BRACKETS AS REQUIRED FOR SUPPORT SUBSTRAiE FOR GLASS MOSAIC TILE SUBSTRAiE WITH WOOD VENEER (WDl) 2X4 BLOCKING SECTION - RECEPTION DESK 0 3" 6�� �� 2� 0 N v NEW QUARTZ (QZl) TRANSACTION TOP ON 1"DIA. STAINLESS STEEL STANDOFFS 1'-0" WRAP MAPLE WOOD VENEER �WDI� AROUND TOP AND SIDES OF DESK NEW MOSAIC GLA$$ TILE (GTI � MAPLE WOOD VENEER �WDI) STAINLESS STEEL TOE KICK 3'-4" I 3'-0" ELEVATION - RECEPTION DESK � � � LcyCi7Y � WOOD VENEER �WDI) :� WITH REMOVABLE PANEL i� TO HOUSE WIRING ) 0 1' 2' 3' r'.: � � � I� � 5� HARDWARE NOTES 1. ALL PULLS ON RECEPTION DESK TO BE #8000-41N. CKP BRAND PREMIUM SERIES STAINLESS STEEL BAR PULL COORDINATE WITH ELEVATIONS FOR QUANTITIES. NEW QUARTZ (QZI) TRANSACTION TOP ON �3� 2" DIA. STAWLESS STEEL STANDOFFS WRAP MAPLE WOOD 6�� VENEER (WDIJ AROUND � TOP AND INSIDE FACE OF DESK 24"D PLASTIC LAMINATE (PL2� WORKSURFACE. PROVIDE �2) WHITE PLASTIC GROMMETS. PROVIDESUPPORT$ A$ REQUIRED. 80X,B0%, FlLE MAPLE WOOD VENEER (WDIJ SEE HARDWARE NOTE STAINLESS STEEL TOE KICK ELEVATION — RECEPTION DESK � ,� 2� 3� � � � � � v O O U O � � � O � � N � � � O pi� �� a� N �mC� � � g � �Qw3 THI$ DRAW WG, AND iHE IDEAS, DESIGNS AND CONCEPT$ CONTA W ED HEREIN, ARE THE E%CWSNE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, MC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOl1TTHE WRITfEN CONSENT OF $CHOTT DESIGN. � N Z c� Q` O / � �� -�z W"— �Zw W C � L . � Z Q �U r � r r SET I� 0. AR10700017 STATE OF PROJECT NUMBER 2014.144 )J. MGR DRAWN BY ACM ACM 2ND FLOOR RECEPTION DESK DETAILS INTERIOR DETAILS A212