HomeMy WebLinkAbout06010064-Site Plan e~j u~ (et / es[) ---- - ~ Easement Une Note: S~nltary Sewer Top of Casting Information Upstrsum Manhole, TC= 912.21 Downstream Menhele, TC=910.51 per record drawings. TC=912.21 PER I~CORD DR^MNG Nots: The garage finished floor elewtion is 2.6' above the curb at the drive, per plan. Note: ~is drawing is based on construction plans or record ' drawings, end is not based upon o field survey, ~he Schneider Corporation does not warrant the acsumcy or sufficiency of ' this information. Contractors should ~rlfy existing c~dittons prior to any construction. Any discrepancy found on this drawing should be reported to '[he Schneider Corpa-atio~ lmmediatel~ failing to do so resulb in the contrcctors ossumpton of al labilty. Note: The basomeat d~Uon, d~plcted hereon, bsa ~ determined ~nd based upon the ~ grades and/or conton~ t~ke~ from the cons~ction pluns far Sis subdivision, t.iniess stated, no infommtia~ abcut fiuctua~9 water thl~ s~l conditions, or soil bpes has be~3 provided or stated so said I~ons It is recanmead.e,d, that the I~m~t flnlohed floor asvetbas I~ at I~st two feat (2) above the n~el pool elevation of uny adjoining bodies of water, ualess a study of facts rsvsols oth~n~ies. If during the exsovatiso proc~s soy 9rcund water Is withes~ed, The Sd,aei~ler Ca'porat~ should be notified immediately. The I~serne~t elevat~ shcuid be robed two feet (2') above the ground water, and eddiUonol construcU~ techniques shculd be inco~pa'ated to alleviate ~uture VB06.0047259 Lot # 224 0 ~ss~med No~th suele: 1' = 50' Detail of Grmmd/ Storm Water flow putt~m lividuel lots. \ /t Note: Builder to ensure 3osttlve drainage away from structure(s). Note: Sump pump(s) to be placed by builder os needed, Sidowelk to bs ploc~ 1' from property line, ~' from b~ of curb, per plan. J R.H. of Indiana Finished Floor Elevation information Pad Grade = 9124 per pan Pad Grade + 0.7.= Garage FFE (913.t) Garage Pr~ + 1.5 = ,Eesidentlal F/E (914.6) Resdent~l FFE - 9.0 = Basement ~ (905.6) FLOOD HAZARD STATEMENT CERTIFICATION ~ ';~." + No. '.. ,~ ~- so o3 I Rood Hazard State,at: Ihs accuracy of my flood hazerd data shown on this raper1 is sub,ct to mup sc~e uor. ertointy and to (ay ether unc~uinty in locution or elevetio~ the ref~ fl~d is~r~ce rate m~. ~ of ~e wi~ ~ I~d D~S NOT lis withn that ~ flo~ hazed z~e AE es said t~d Hats by rate m~ ~l 0205 F f~ ~e City of ~a, tnd~a d~t~ F~ru=y Dround Cover Calculations: Drive = 806 ~:t: Public Walk =319 SFJ: Private Walk =89 SF+ HFIro~eeding =7 841 SF+ Sod =517 SY:i: . from Rear of residence. Nots: [he contractor is to maintain u mh~um distance of t~ f~[ (10') betwe~ ~a s~itery sew~ ~d wat~ tine lat~s. Nots: Per Casa z~hg ~once 26.t,1: ~e res[~tJel dS~t limits h~t to t~t~fl~ feet (25). hown~r a dw~ing may be ~d ~ he~t to ~Id~fi~ f~t (~') Fo~d~ ~e ~ ~d rem ~rds ~e ~d ~ ~t~ ~e f~t (1') f~ each ~e f~t (1') ~e s~c~m exc~s the ~t tw~t~ f~t (25') h helghL