HomeMy WebLinkAboutBellaria Pizza VOWC Electrical PlanG. C. ' TO PROVIDE ALL BLOCKING AS REQUIRED BY EQUIPMENT. ALL CUTS OR SLEEVES IN FLOOR WALLS, CEILINGS OR ROOF. puwp@ ?E* 00HIUV P.C. TO PROVIDE ALL LABOR AND MATERIALS TO MATERIALS TO ROUGH -IN AND MAKE FINAL CONNECTIONS AS NOTED. ALL DIMENSIONS ARE SHOWN FROM FINISHED SURFACE TO CENTER LINE ROUGH -IN, VERIFY WALL DIMENSIONS WITH ARCHITECT, P.C. TO INSTALL- ALL COMPONENTS PROVIDED BY K.E.C. AND PLUMB AS DIRECTED BY K.E.C. WOOD KCDM AOTEV� FOR HAND Mg 9c TO PROVIDE 24" WIDE X 3/4" PLYWOOD WOOD BLOCKING LOCATED BETWEEN ,34"-AFF & 42"-AFF LEAEN _ WOOD BLOCKING ?tCI L ,ham L1�TES 71 u p Cc TO PROVIDE 24" WIDE X 3/4" PLYWOOD WOOD BLOCKING LOCATED BETWEEN 60"-AFF & 84"-AFF MEMO WOOD BLOCKING NOTE: NOTE: CONVENIENCE OUTLETS ARE TO BE LOCATED ALL DIMENSIONS ARE TAKEN FROM BY OWNER /ARCHITECT. UNFINISHED WALLS. E.C.TO FIELD VERIFY NOTE: LOCATE BREAKER PANELS Ex9 °` BY8BY8 F-rte G:IOO xa ®c - TO SET, FLASH, & CUT OPENINGS FOR EXHAUST & SUPPLY CURBS AND PROVIDE CHASE WORK REQUIRED BY NFPA 96 AS NEEDED HOOD #17: xC - TO PROVIDE 208 -V, 3 -PH, 5 -HP, 16.7 AMPS [1] EXHAUST FAN AND 208 -V, 3 -PH, 3 HP, 10.6 AMPS TO (1) SUPPLY FAN. PROVIDE SWITCH & MOTOR STARTER WITH AUTOMATIC THERMAL PROTECTION DEVICE. E.C. TO INTERWIRE FANS TO OPERATE TOGETHER AND INTERCONNECT MOTOR STARTERS WITH FIRE SUPPRESSION SYSTEM TO TERMINATE POWER TO SUPPLY FAN AND MAINTAIN POWER TO EXHAUST FAN UPON FIRE SUPPRESSION SYSTEM DISCHARGE AS BY K.E.C. MAINTAIN POWER TO EXHAUST FAN UPON FIRE SUPPRESSION SYSTEM MC - 10,500 CFM EXHAUSTED AIR. SUPPLY AIR TO BE 8,500 CFM. BUILDING SYSTEM TO PROVIDE 2,000 CFM MAKE -UP AIR FREEZER I rE -I 5d [COOL]FR 4 - (E -15c ELECTRICAL- CONNECTION SCHEDULE E-1 120 -V, 1 -PH SERVICE, 15 AMP, ELECTRICAL OUTLET AT 2' -0" AFF FOR SERVICE TO ITEM #1, ICE BIN W/ SODA TOWER (VERIFY WITH BEVERAGE PROVIDER) E -2 120/208 V, 1 -PH SERVICE, 30 AMP, ELECTRICAL CUTLET AT 4' -0" AFF FOR SERVICE TO ITEM #2, COFFEE BREWER (VERIFY WITH BEVERAGE PROVIDER) E -3 120 -V, 1 -OH SERVICE, 15 AMP, ELECTRICAL OUTLET AT 4' -0" AFF FOR SERVICE TO ITEM #3, TEA BREWER (VERIFY WITH+ BEVERAGE PROVIDER) E -4 120 -V, 1 -PH SERVICE, 15 AMP, ELECTRICAL OUTLET AT 4' -0 "AFF FOR SERVICE TO ITEM #4, P.O.S (VERIFY WITH OWNER) E -8 120 -V, 1 -PH SERVICE, 2.0 AMP, ELECTRICAL OUTLET AT 6' -0" AFF FOR SERVICE TO ITEM #8, B.I,A.B. (VERIFY WITH OWNER) E -9 208 VOLT, 3 HP SERVICE, 8.5 AMP, 3 H.P., ELECTRICAL OUTLET AT 4' -0" AFF FOR SERVICE TO ITEM #9, 60 OT MIXER (E.C, TO PROVIDE CORD, PLUG AND RECEPTACLE) E -11 120-V, 1 -PH SERVICE, 20 AMP, 3/4 H.P„ ELECTRICAL OUTLET AT 4' -0" AFF FOR SERVICE TO ITEM #11, DOUGH ROLLER E -15 120 VOLT, 1 PH SERVICE, 15 AMP, DROP FROM ABOVE EXTEND AND CONNECT AT ITEM #15, WALK -IN COOLER /FREEZER COMBO (COOLER SECTION LIGHTS AND EVAPORATOR) (E.C. TO PROVIDE AND INSTALL ANY ADDITIONAL LIGHTS) E -15b 120 VOLT, 1 PH SERVICE, 9 AMP, DROP FROM ABOVE EXTEND AND CONNECT AT ITEM #15, WALK -IN COOLER /FREEZER COMBO (FREEZER SECTION LIGHTS AND DOOR HEATER) (E.C. TO PROVIDE AND INSTALL ANY ADDITIONAL LIGHTS) E -15,_ 208 VOLT, 1 PH SERVICE, 7.2 AMP, 3/4 H.P„ EXTEND AND CONNECT TO ITEM #15, WALK -IN C0OLfp,iFREF7FR COMBO (COOLER SECTION) (COMPRESSOR TO BE LOCATED OUTSIDE) (E.C. TO INTERWIRE THERMOSTAT, SOLENOID AND EVAPORATOR) E -15d 208 VOLT, 1 PH SERVICE, 14.4AMP, 1- 1 /2H.P., EXTEND AND CONNECT TO ITEM #15, WALK -IN COOLER /FREEZER COMBO (FREEZER SECTION) (COMPRESSOR TO BE LOCATED OUTSIDE) (E.C. TO INTERWIRE THERMOSTAT, SOLENOID AND EVAPORATOR) E-1 5e 120 VOLT, 1 PH SERVICE, 1.0 AMP, DIRECT CONNECT AT ITEM #15, WALK -IN COOLER /FREEZER COMBO (COOLER SECTION) FOR SERVICE TO DEFROST CLOCK (E.C. TO RUN 120 VOLT TO DEFROST CLOCK TO BE LOCATED ON FRONT FACE OF WALK -IN COOLER PANEL AS DIRECTED BY K.E.C. AND THEN TO LIQUID LINE SOLENOID THERMOSTAT) (DEFROST CLOCK TO BE SHIPPED LOOSE) E 15f 208 VOLT, 1 PH SERVICE, 7 AMP, DROP FROM ABOVE EXTEND AND CONNECT AT ITEM #15, WALK -IN COOLER, /FREEZER COMBO (FREEZER SECTION) FOR EVAPORATOR (E,C. TO PROVIDE AND INSTALL IN -LINE DRAIN HEATER FOR EVAPORATOR AND CONNECT TO TERMINAL BLOCK OF EVAPORATOR) E -17 120 VOLT, 1 PH SERVICE, 10 AMP, DROP FROM ABOVE EXTEND AND CONNECT AT ITEM #17, HOOD (LIGHTS) (SEE EXHAUST SYSTEM NOTES FOR ADDITIONAL CONNECTIONS) E = -18 208 VOLT, 3 PH SERVICE, 27 AMP, ELECTRICAL OUTLET AT 4' -0" AFF FOR SERVICE TO ITEM #18, COMBI OVEN (EC. TO PROVIDE CORD, PLUG & RECEPTACLE) E-20 120 VOLT, 1 PH SERVICE, 5 AMP, ELECTRICAL OUTLET AT 2' -0" AFF FOR SERVICE TO ITEM #20, PASTA COOKER SYSTEM E 24 120 VOLT, 1 PH SERVICE, 20 AMP, DEDICATED LINE, ELECTRICAL OUTLET AT 2' -0° AFF FOR SERVICE TO ITEM #24, CONVEYOR OVEN (NEMA 5 -15P) E - 24b 120 VOLT, 1 PH SERVICE, 20 AMP, DEDICATED LINE, ELECTRICAL OUTLET AT 3' -0" AFF FOR SERVICE TO ITEM #24, CONVEYOR OVEN (NEMA 5 -15P) E - 2 4 c 120 VOLT, 1 PH SERVICE, 20 AMP, DEDICATED LINE, ELECTRICAL OUTLET AT 4' -0" AFF FOR SERVICE TO ITEM #24, CONVEYOR OVEN (NEMA 5 -15P) E -29 120 VOLT, 1 PH 'SERVICE, 20 AMP, DEDICATED LINE, ELECTRICAL OUTLET AT l' -6" AFF FOR SERVICE TO ITEM #29, SINGLE DOOR REACH -IN FREEZER (NEMA 5 -15P) E -33 120 VOLT, 1 PH SERVICE, 16 AMP, ELECTRICAL OUTLET AT 5' -6" AFF AND CONNECT AT ITEM #33, LOW TEMP DISHMACHINE (E.C. TO PROVIDE CORD, PLUG AND RECEPTACLE) E -35 208 VOLT, 1 PH SERVICE, 5.1 AMP, 1 H.P., STUB OUT WALL AT 1' -6" AFF AND CONNECT AT ITEM #35, 1 H.P. COMMERCIAL DISPOSER (DIRECT CONNECT) (E.C. TO INTERWIRE SOLENOID) E -38 E.C. TO STUB UP THROUGH FLOOR 120/208/3PH TO 200 AMP BREAKER PANEL BOX AND CONNECT TO BREAKER PANEL BOX THE FOLLOWING: 120 VOLT, 1 PH SERVICE, 20 AMP DEDICATED LINE FOR SERVICE TO ITEM #28, REFRIGERATED PREP TABLE (NEMA 5 -15P); 208 VOLT, 1PH SERVICE, 12 .5 AMP FOR SERVICE TO ITEM #27, THREE WELL HOT FOOD TABLE (NEMA 6 -20P); 120 VOLT, 1 PH SERVICE, 20 AMP DEDICATED LINE. FOR SERVICE TO ITEM #26, REFRIGERATED PIZZA PREP TABLE 93" (NEMA 5 -15P); 120 VOLT, 1PH SERVICE, 15 AMP FOR CONNECTION TO DUPLEX TOMBSTONES (2 LOCATIONS) (CONVENIENCE OUTLETS); 120/208 VOLT, I PH SERVICE, 2800 WATT, FOR SERVICE TO ITEM #39, DUAL MOUNT HEAT LAMP 60 "(2 LOCATIONS) (DIRECT CONNECT) AND 120/208 `JOLT, 1 PH SERVICE, 3450 WATT, FOR SERVICE TO ITEM #39, DUAL MOUNT HEAT LAMP 72" (DIRECT CONNECT). E -41 120 VOLT, 1 PH SERVICE, 20 AMP DEDICATED LINE, ELECTRICAL OUTLET AT 1' -6" AFF FOR SERVICE TO ITEM #41, TWO DOOR REACH -IN COOLER (NEMA 5 -15P) E -43 208 VOLT, 1 PH SERVICE, 13.6 AMP, ELECTRICAL OUTLET AT 6' -6" AFF FOR SERVICE TO ITEM #43, ICE MACHINE W/ BIN (E.C. TO PROVIDE CORD, PLUG, AND RECEPTACLE) E -46 120 VOLT, 1 PH SERVICE, 20 AMP DEDICATED LINE, ELECTRICAL OUTLET AT 1' -6" AFF FOR SERVICE TO ITEM #46, DIRECT DRAW DRAFT BOX (NEMA 5 -15P) E -48 120 VOLT, 1 PH SERVICE, 20 AMP DEDICATED LINE, ELECTRICAL OUTLET AT 1' -6" AFF FOR SERVICE TO ITEM #48, BACK BAR COOLER (NEMA 5 -15P� E -49 120' VOLT, 1 PH SERVICE, 20 AMP DEDICATED LINE, ELECTRICAL OUTLET AT 1' -6" AFF FOR SERVICE TO ITEM #49, HORIZONTAL BOTTLE COOLER (NEMA 5 -15P) E -100 120 VOLT, 1 PH SERVICE, 20 AMP, DUPLEX CONVENIENCE OUTLET AT 4' -0" AFF (3 LOCATIONS) (VERIFY WITH OWNER) E -101 120 VOLT, 1 PH SERVICE, 20 AMP, DUPLEX CONVENIENCE OUTLET AT 3' -2" AFI (1 LOCATIONS) (VERIFY WITH OWNER) (FOR ITEM #40, GLASS WASHER) (HORIZONTAL MOUNT)