HomeMy WebLinkAboutBellaria Pizza VOWC Electrical PlanG. C. '
TO PROVIDE ALL BLOCKING AS REQUIRED
BY EQUIPMENT. ALL CUTS OR SLEEVES IN
FLOOR WALLS, CEILINGS OR ROOF.
puwp@ ?E* 00HIUV
P.C. TO PROVIDE ALL LABOR AND MATERIALS
TO MATERIALS TO ROUGH -IN AND MAKE FINAL
CONNECTIONS AS NOTED. ALL DIMENSIONS ARE
SHOWN FROM FINISHED SURFACE TO CENTER
LINE ROUGH -IN, VERIFY WALL DIMENSIONS WITH
ARCHITECT, P.C. TO INSTALL- ALL COMPONENTS
PROVIDED BY K.E.C. AND PLUMB AS DIRECTED
BY K.E.C.
WOOD KCDM AOTEV�
FOR HAND Mg
9c
TO PROVIDE 24" WIDE X 3/4" PLYWOOD
WOOD BLOCKING LOCATED BETWEEN
,34"-AFF & 42"-AFF
LEAEN _
WOOD BLOCKING
?tCI L ,ham L1�TES
71 u p
Cc
TO PROVIDE 24" WIDE X 3/4" PLYWOOD
WOOD BLOCKING LOCATED BETWEEN
60"-AFF & 84"-AFF
MEMO
WOOD BLOCKING
NOTE: NOTE:
CONVENIENCE OUTLETS ARE TO BE LOCATED ALL DIMENSIONS ARE TAKEN FROM
BY OWNER /ARCHITECT. UNFINISHED WALLS. E.C.TO FIELD VERIFY
NOTE: LOCATE BREAKER PANELS
Ex9 °` BY8BY8 F-rte G:IOO xa
®c - TO SET, FLASH, & CUT OPENINGS FOR EXHAUST & SUPPLY
CURBS AND PROVIDE CHASE WORK REQUIRED
BY NFPA 96 AS NEEDED
HOOD #17:
xC - TO PROVIDE 208 -V, 3 -PH, 5 -HP, 16.7 AMPS [1] EXHAUST
FAN AND 208 -V, 3 -PH, 3 HP, 10.6 AMPS TO (1) SUPPLY FAN.
PROVIDE SWITCH & MOTOR STARTER WITH AUTOMATIC THERMAL
PROTECTION DEVICE. E.C. TO INTERWIRE FANS TO OPERATE
TOGETHER AND INTERCONNECT MOTOR STARTERS WITH FIRE
SUPPRESSION SYSTEM TO TERMINATE POWER TO SUPPLY FAN AND
MAINTAIN POWER TO EXHAUST FAN UPON FIRE SUPPRESSION SYSTEM
DISCHARGE AS BY K.E.C. MAINTAIN POWER TO EXHAUST FAN UPON
FIRE SUPPRESSION SYSTEM
MC - 10,500 CFM EXHAUSTED AIR. SUPPLY AIR TO BE 8,500 CFM.
BUILDING SYSTEM TO PROVIDE 2,000 CFM MAKE -UP AIR
FREEZER I rE -I 5d
[COOL]FR 4 - (E -15c
ELECTRICAL- CONNECTION SCHEDULE
E-1 120 -V, 1 -PH SERVICE, 15 AMP, ELECTRICAL OUTLET AT 2' -0" AFF
FOR SERVICE TO ITEM #1, ICE BIN W/ SODA TOWER (VERIFY
WITH BEVERAGE PROVIDER)
E -2 120/208 V, 1 -PH SERVICE, 30 AMP, ELECTRICAL CUTLET AT 4' -0" AFF
FOR SERVICE TO ITEM #2, COFFEE BREWER (VERIFY WITH
BEVERAGE PROVIDER)
E -3 120 -V, 1 -OH SERVICE, 15 AMP, ELECTRICAL OUTLET AT 4' -0" AFF
FOR SERVICE TO ITEM #3, TEA BREWER (VERIFY WITH+
BEVERAGE PROVIDER)
E -4 120 -V, 1 -PH SERVICE, 15 AMP, ELECTRICAL OUTLET AT 4' -0 "AFF
FOR SERVICE TO ITEM #4, P.O.S (VERIFY WITH OWNER)
E -8 120 -V, 1 -PH SERVICE, 2.0 AMP, ELECTRICAL OUTLET AT 6' -0" AFF
FOR SERVICE TO ITEM #8, B.I,A.B. (VERIFY WITH OWNER)
E -9 208 VOLT, 3 HP SERVICE, 8.5 AMP, 3 H.P., ELECTRICAL OUTLET AT
4' -0" AFF FOR SERVICE TO ITEM #9, 60 OT MIXER (E.C, TO PROVIDE CORD,
PLUG AND RECEPTACLE)
E -11 120-V, 1 -PH SERVICE, 20 AMP, 3/4 H.P„ ELECTRICAL OUTLET AT 4' -0" AFF
FOR SERVICE TO ITEM #11, DOUGH ROLLER
E -15 120 VOLT, 1 PH SERVICE, 15 AMP, DROP FROM ABOVE EXTEND AND CONNECT
AT ITEM #15, WALK -IN COOLER /FREEZER COMBO (COOLER SECTION LIGHTS
AND EVAPORATOR) (E.C. TO PROVIDE AND INSTALL ANY ADDITIONAL LIGHTS)
E -15b 120 VOLT, 1 PH SERVICE, 9 AMP, DROP FROM ABOVE EXTEND AND CONNECT AT
ITEM #15, WALK -IN COOLER /FREEZER COMBO (FREEZER SECTION LIGHTS
AND DOOR HEATER) (E.C. TO PROVIDE AND INSTALL ANY ADDITIONAL LIGHTS)
E -15,_ 208 VOLT, 1 PH SERVICE, 7.2 AMP, 3/4 H.P„ EXTEND AND CONNECT TO ITEM
#15, WALK -IN C0OLfp,iFREF7FR COMBO (COOLER SECTION) (COMPRESSOR TO BE
LOCATED OUTSIDE) (E.C. TO INTERWIRE THERMOSTAT, SOLENOID AND EVAPORATOR)
E -15d 208 VOLT, 1 PH SERVICE, 14.4AMP, 1- 1 /2H.P., EXTEND AND CONNECT TO ITEM
#15, WALK -IN COOLER /FREEZER COMBO (FREEZER SECTION) (COMPRESSOR TO BE
LOCATED OUTSIDE) (E.C. TO INTERWIRE THERMOSTAT, SOLENOID AND EVAPORATOR)
E-1 5e 120 VOLT, 1 PH SERVICE, 1.0 AMP, DIRECT CONNECT AT ITEM #15, WALK -IN
COOLER /FREEZER COMBO (COOLER SECTION) FOR SERVICE TO DEFROST CLOCK
(E.C. TO RUN 120 VOLT TO DEFROST CLOCK TO BE LOCATED ON FRONT FACE OF
WALK -IN COOLER PANEL AS DIRECTED BY K.E.C. AND THEN TO LIQUID LINE SOLENOID
THERMOSTAT) (DEFROST CLOCK TO BE SHIPPED LOOSE)
E 15f 208 VOLT, 1 PH SERVICE, 7 AMP, DROP FROM ABOVE EXTEND AND CONNECT
AT ITEM #15, WALK -IN COOLER, /FREEZER COMBO (FREEZER SECTION) FOR
EVAPORATOR (E,C. TO PROVIDE AND INSTALL IN -LINE DRAIN HEATER FOR
EVAPORATOR AND CONNECT TO TERMINAL BLOCK OF EVAPORATOR)
E -17 120 VOLT, 1 PH SERVICE, 10 AMP, DROP FROM ABOVE EXTEND AND CONNECT
AT ITEM #17, HOOD (LIGHTS) (SEE EXHAUST SYSTEM NOTES FOR ADDITIONAL
CONNECTIONS)
E = -18 208 VOLT, 3 PH SERVICE, 27 AMP, ELECTRICAL OUTLET AT 4' -0" AFF FOR SERVICE
TO ITEM #18, COMBI OVEN (EC. TO PROVIDE CORD, PLUG & RECEPTACLE)
E-20 120 VOLT, 1 PH SERVICE, 5 AMP, ELECTRICAL OUTLET AT 2' -0" AFF FOR
SERVICE TO ITEM #20, PASTA COOKER SYSTEM
E 24 120 VOLT, 1 PH SERVICE, 20 AMP, DEDICATED LINE, ELECTRICAL OUTLET AT
2' -0° AFF FOR SERVICE TO ITEM #24, CONVEYOR OVEN (NEMA 5 -15P)
E - 24b 120 VOLT, 1 PH SERVICE, 20 AMP, DEDICATED LINE, ELECTRICAL OUTLET AT
3' -0" AFF FOR SERVICE TO ITEM #24, CONVEYOR OVEN (NEMA 5 -15P)
E - 2 4 c 120 VOLT, 1 PH SERVICE, 20 AMP, DEDICATED LINE, ELECTRICAL OUTLET AT
4' -0" AFF FOR SERVICE TO ITEM #24, CONVEYOR OVEN (NEMA 5 -15P)
E -29 120 VOLT, 1 PH 'SERVICE, 20 AMP, DEDICATED LINE, ELECTRICAL OUTLET AT
l' -6" AFF FOR SERVICE TO ITEM #29, SINGLE DOOR REACH -IN FREEZER
(NEMA 5 -15P)
E -33 120 VOLT, 1 PH SERVICE, 16 AMP, ELECTRICAL OUTLET AT 5' -6" AFF AND
CONNECT AT ITEM #33, LOW TEMP DISHMACHINE (E.C. TO PROVIDE CORD,
PLUG AND RECEPTACLE)
E -35 208 VOLT, 1 PH SERVICE, 5.1 AMP, 1 H.P., STUB OUT WALL AT 1' -6" AFF AND
CONNECT AT ITEM #35, 1 H.P. COMMERCIAL DISPOSER (DIRECT CONNECT)
(E.C. TO INTERWIRE SOLENOID)
E -38 E.C. TO STUB UP THROUGH FLOOR 120/208/3PH TO 200 AMP BREAKER PANEL
BOX AND CONNECT TO BREAKER PANEL BOX THE FOLLOWING:
120 VOLT, 1 PH SERVICE, 20 AMP DEDICATED LINE FOR SERVICE TO ITEM
#28, REFRIGERATED PREP TABLE (NEMA 5 -15P); 208 VOLT, 1PH SERVICE,
12 .5 AMP FOR SERVICE TO ITEM #27, THREE WELL HOT FOOD TABLE (NEMA 6 -20P);
120 VOLT, 1 PH SERVICE, 20 AMP DEDICATED LINE. FOR SERVICE TO ITEM #26,
REFRIGERATED PIZZA PREP TABLE 93" (NEMA 5 -15P); 120 VOLT, 1PH SERVICE, 15 AMP
FOR CONNECTION TO DUPLEX TOMBSTONES (2 LOCATIONS) (CONVENIENCE OUTLETS);
120/208 VOLT, I PH SERVICE, 2800 WATT, FOR SERVICE TO ITEM #39, DUAL MOUNT
HEAT LAMP 60 "(2 LOCATIONS) (DIRECT CONNECT) AND 120/208 `JOLT, 1 PH SERVICE,
3450 WATT, FOR SERVICE TO ITEM #39, DUAL MOUNT HEAT LAMP 72"
(DIRECT CONNECT).
E -41 120 VOLT, 1 PH SERVICE, 20 AMP DEDICATED LINE, ELECTRICAL OUTLET AT 1' -6" AFF
FOR SERVICE TO ITEM #41, TWO DOOR REACH -IN COOLER (NEMA 5 -15P)
E -43 208 VOLT, 1 PH SERVICE, 13.6 AMP, ELECTRICAL OUTLET AT 6' -6" AFF FOR
SERVICE TO ITEM #43, ICE MACHINE W/ BIN (E.C. TO PROVIDE CORD, PLUG, AND
RECEPTACLE)
E -46 120 VOLT, 1 PH SERVICE, 20 AMP DEDICATED LINE, ELECTRICAL OUTLET AT 1' -6"
AFF FOR SERVICE TO ITEM #46, DIRECT DRAW DRAFT BOX (NEMA 5 -15P)
E -48 120 VOLT, 1 PH SERVICE, 20 AMP DEDICATED LINE, ELECTRICAL OUTLET AT 1' -6"
AFF FOR SERVICE TO ITEM #48, BACK BAR COOLER (NEMA 5 -15P�
E -49 120' VOLT, 1 PH SERVICE, 20 AMP DEDICATED LINE, ELECTRICAL OUTLET AT 1' -6"
AFF FOR SERVICE TO ITEM #49, HORIZONTAL BOTTLE COOLER (NEMA 5 -15P)
E -100 120 VOLT, 1 PH SERVICE, 20 AMP, DUPLEX CONVENIENCE OUTLET AT 4' -0" AFF
(3 LOCATIONS) (VERIFY WITH OWNER)
E -101 120 VOLT, 1 PH SERVICE, 20 AMP, DUPLEX CONVENIENCE OUTLET AT 3' -2" AFI
(1 LOCATIONS) (VERIFY WITH OWNER) (FOR ITEM #40, GLASS WASHER)