Loading...
HomeMy WebLinkAbout09 45-01SP Sanitary Sewer Plan and Profile} m cn z . 5+70 SCALE: 1"=50' HOR. 27 " I 1 " =5' VERT. 19 L.F. -6 I WYE & LAT. I o STA. 2 +54 IR } O m Q m Q a0 • ui m3 SCALE: 1 "= 50' I I 760 760 M I • e -e I 26 ��o`` STOEPpF�'�.,. 15 L.F. -6" .���a�0 ,' �STE,gF,A - -i I I WYE & LAT. I _` �O STA. 1+99 _ NO. 19358 I I I ; -0 STATE OF Ulf �'�90 ' /�VDIANP �16V - ............ ....... N.,,. I M / 750 750 p r 25 I _W 15 L.F. 6" I \ WYE & LAT. w / I > I STA. 0 +99 U \ 28 100 L.F. -6" I \ WYE & LAT. I (n N ¢ STA. 0 +69 I I IY 0) a + I o � Z / \ \ 29 " I I w 0) / 17 LF. -6 I 24 > 00 WYE & LAT. 15 L.F. -6" I , D \ STA. 0 +49 I WYE &LAT. � STA. 0 +16 I rO / \ I • / NOTES / os / 30 + FULL DEPTH GRANULAR BACKFILL SHALL BE 12 L.F. -6" I INSTALLED ON ALL SEWER LATERAL STREET °� WYE &LAT. / 23 / STA. 0 +24 / ! I 15 L.F. -6" CROSSINGS & COMPACTED PER I.D.O.H. STANDARDS. w / WYE &LAT. I z 0 / I STA. 2 +25 (� 000 / I MIN. SLOPES PER THE TEN STATE STANDARDS W I NOTE TO CONTRACTOR. 4 \ 80 36 6" SHALL PREVAIL IN ALL CASES. � / Q) WYE & LAT. I I SANITARY INVERTS MUST BE VERIFIED AT Z cp / 15 L3.� 6" ',/ V \ STA. 1+41 I I MANHOLES 709-711 PRIOR TO CONTINUING WITH CONTRACTOR SHALL EXTEND SEWER LATERALS J �, �, / NEXT SEGMENT OF PIPE TO MAINTAIN DESIGNED - / WYE &LAT. �� I THRU EASEMENTS AS SHOWN. A MINIMUM OF 5 FT. w 00 STA. 1 +25 / /w I 22 INVERTS TO AVOID FUTURE STORM CONFLICT. (n a / �— i 3 • -e 16 L.F. -6" ANY DEVIATION FROM MAINTAINING DESIGN AND A MAXIMUM OF 6 FT. OF COVER OVER LATERAL zo o WYE & LAT. ( INVERT ELEVATIONS ON THESE WILL BE AT TERMINATION. U ? / \ v STA. 1 +35 CONTRACTORS OWN RISK. / -s 35 " I > _J / 32 D 75 LF. -6 / 18 L.F. -6" tH WYE & LAT. WYE &LAT. / STA. 1 +79 / STA. 1 +37 / W / I v I 37 99 L.F. -6" ( 21 n I WYE & LAT. 16 L.F. -6 STA. 0 +68 STA. 0 +45 I Q SCALE. 1"=50' _ H OR. Lij z f I 1" 5' VERT. J Q / o gLE 706 } / / ( r1r" 00 Z li + a. 34 l 760 0 33 I 83 L.F. -6" I I I 38 1! 7so it : it r WYE & LAT. EXISTING :: EXISTING �m..._...__.........._._ .......` . ...........................i... STA. 2 +01 I 102 L.F. -6" it U WYE &LAT. I I I WYE &LAT. i it STA. 2 +03 I STA. 2 +32 i 7 W it E, I V Ck„ E E :E a f 3: .f E EI iE E .q 3 f I [ E €E ? EE n cn 750 NN 0 j 750 1.(. O W /W Z VJ O LL �n Q V Z W Q Of Q U SHEET NO. 9 OF 14 SHEETS 11 No.29648 O ^ N N no`°o rn� �rn� _ n 'p tD tO � a o'� rN�W O�� °' �^ j �ooM I � I 0 0 0 wo�z ncn'nta.i3 nr)�j 11,3 � +nViz3 W -E +�z� -0 II or) ^f-t- +��� aaci��� ¢�UZ z . II �� z¢Ci�� �cn�_ ¢�ci�� � } FULL DEPTH al GRANULAR EXISTING GRADE PROPOSED GRADE BACKFlLL =o 185 L.F. 0.40% " 8 S.D.R. 35 P. 15 R.C.P. - „,r;•�•, ,,� �...�� V.C. 123 L.F. INV.= 747.56 • • 183 L.F. 0.42% krW” �Q o � Q n � � + ^viz3 N" = II mmm ZQII �NF,:ZZZ ¢ U� EXISTING GRADE PROPOSED GRADE I ` 012" R.C.P. INV.= 748.32 I I CONTRACTOR TO VERIFY INV. 8" S.D.R. 35 P.V.C. 0.61% PRIOR TO CONSTRUCTION 259 L.F. 8" S.D.R. 35 P.V.C. 3 291' EX. 8" S.D.R. 35 P.V.C. INV.= 743.42 S. S.D.R. 35 P.V.C. 18" R. .P. INV. =7 .79 CROSSING TO B ENCASED WITH GRANULAR BAC ILL. CONTRACTOR TO VERIFY GRAD T10N TO BE USED PRIOR TO INSTA LAT10N. �Q o � Q n � � + ^viz3 N" = II mmm ZQII �NF,:ZZZ ¢ U� EXISTING GRADE PROPOSED GRADE I ` 012" R.C.P. INV.= 748.32 I I CONTRACTOR TO VERIFY INV. 8" S.D.R. 35 P.V.C. 0.61% PRIOR TO CONSTRUCTION 259 L.F. 8" S.D.R. 35 P.V.C. 3 291' EX. 8" S.D.R. 35 P.V.C. INV.= 743.42 S.