HomeMy WebLinkAbout44-01 Plans March 22 2001 1st floor framing planFOUNDATION NOTES: I. ELEVATIONS: T /WALL FTG.= +87' -O" UNO. T /COL FTG.= +87' -4" UNO. T /CONCRETE WALL = +99' -7" UNO. T /CMU WALL = +99' -2" UNO. T /SLAB BASEMENT FLOOR= +88' -O" UNO. T /SLAB FIRST FLOOR= +100' -O" UNO (SEE CIVIL FOR ACTUAL) 2. SLAB ON GRADE: TYPICAL: 4" WITH 6x6xW1.4xW1.4 WWF ALL SLABS ON 6" DRAINABLE COMPACTED FILL ON 6 MIL VAPOR BARRIER. 3. GRADE BEAM GB1 SHALL BE 16 "x2' -6" REINFORCED WITH (3) #5 TOP AND BOTTOM, #3 CLOSED TIES @ 32" 0 /C. PROVIDE 16" DIA PIERS AT EXTERIOR COLUMN LOCATIONS FROM T /GRADE BEAM TO ELEVATION 100' -0" REINFORCED WITH (4) #4 VERTICAL BARS AND ONE #3 TIE AT TOP. FIRST FLOOR FRAMING NOTES: 1. FLOOR TO BE 3" N.W. CONCRETE SLAB WITH 6x6- W1.4xW1.4 WWF OVER 2" x 22GA. COMPOSITE MTL. DECK (5" TOTAL SLAB THICKNESS) FASTEN DECK TO SUPPORTS USING 5/8" DIA, PUDDLE WELDS AT 12" O.C. (6" O.C. AT PERIMETER SUPPORTS) 2. FINISH FLOOR ELEVATION = +100' -0" DECK BRG. ELEVATION = +99' -7" ((U.N.O.) JOIST BEARING ELEVATION = +99' -2 , 3. PROVIDE HORIZONTAL BRIDGING IN ACCORDANCE WITH SJI SPECIFICATIONS. 4. VALUES NOTED AT BEAM & JOIST GIRDER ENDS ARE MAXIMUM SERVICE REACTIONS. IF NO VALUE IS SHOWN THEN ASSUME MINIMUM DESIGN REACTION OF 8.0 KIPS, 5. ALL WIDE FLANGE MEMBERS SHALL CONFORM TO ASTM A572 (Fy =50 KSI). WIDE FLANGE COLUMNS SHALL BE ASTM A572 (Fy =50 KSI). 6. STEEL TUBING SHALL CONFORM TO ASTM A500 GRADE B (Fy =46 KSI). 7. SEE 1 /S401 FOR TYP. BEAM CONNECTIONS AND BOLT SCHED. 8. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT- DIPPED GALVANIZED (U.N.O.) 9. EDGE OF SLAB (E.O.S.)= 6" TYPICAL FROM BEAM CENTER LINE AT OPENINGS (U.N.O.) SEE CIVIL FOR RETAINING WALLS 10'_6" (6) 0 11" . 5' WALL FRAMING NOTES: 1. TYPICAL EXTERIOR WALL CONSTRUCTION: 2x6 SYP #2 STUDS @ 16" 0/C W/ BLOCKING AT 8' -0 ". SHEATHING TO BE 1/2" APA 32/16 SPAN RATED OSB ATTACHED W/ 8d COMMON @ 12" 0/C FIELD 6" 0/C ALL EDGES. SECURE PRESSURE TREATED SILL PLATES TO SLAB 1/2 "x 2 -1/2" EMBEDDMENT EXP. BOLTS @ 24" 0 /C. PROVIDE (2) 2X6 HF #2 OR BETTER TOP PLATES. 2. ALL HEADERS SHALL BE (3) 2x12 SYP #2 WITH 1/2" PLYWOOD OR OSB SPACERS UNO ON PLAN, PROVIDE TRIMMERS AND KINGS STUDS AS FOLLOWS: UP TO 4' OPENINGS: ONE (1) TRIMMER AND ONE(1) KING STUD. 4' TO 8' OPENINGS: TWO (2) TRIMMERS AND THREE (3) KING STUDS, 3. FOR OPENINGS UP TO 12' PROVIDE THREE (3) 1- 3/4 "x9 -1/4" LVLS WITH TWO (2) TRIMMERS AND FOUR (4) KING STUDS. 4. PROVIDE WALL TO FOUNDATION TIE 0 AT GIRDER LOCATIONS INDICATED AND (2) AT EACH CORNER OF BUILDING. 5, BRICK LINTELS SHALL BE AS FOLLOWS WITH ALL LINTELS GALV. SPAN LINTEL BEARING TO 4' -0" L4x3 1/2xi/4 LLV 4" 4' TO 8' -0" 1_50 1/2x3/8 LLV 8" 6. SEE SPECIAL LINTEL ELEVATIONS AT ENTRY AND ABOVE LOWER ENTRY BEAM SIZE INDICATES NUMBER OF EQUALLY SPACED SHEAR CONNECTORS 24k W1800 (17) C =2 1/4" 26K H LL REQUIRED MILL APPLIED OR SERVICE LOAD GRAVITY SHOP APPLIED CAMBER REACTION FOR CONNECTION DESIGN KEY FOR BEAMS 1) IF (20) IS OMITTED ON BEAM THEN COMPOSITE CONSTRUCTION IS NOT REQ'D, 2) ALL SHEAR CONNECTORS TO BE 3/4" DIA. x 3 1/2" LONG. SHEAR CONNECTORS TO BE WELDED THROUGH STEEL DECK USING STUD WELDING GUN, STICK WELDING IS NOT ALLOWED. 3) WHERE STEEL EDGE ANGLES OR STEEL ANGLE BENT PLATE ARE USED ON PERIMETER STEEL BEAMS, ANGLE OR PLATE MUST BE ATTACHED 1 "± OFF OF BEAM CENTER LINE TOWARD EXPOSED EDGE TO ALLOW SHEAR CONNECTOR TO BE ATTACHED DIRECTLY TO BEAM FLANGE. SHEAR CONNECTORS CAN BE WELDED THROUGH GAUGE METAL POUR STOPS AND CELL CLOSURES. 4) FASTEN FLOOR DECK TO BEAMS WITH 5/8" PUDDLE WELDS @ 12" O.C. MAXIMUM, SEE CIVIL FOR ELEVATIONS 7" TREADS TYP. CONSTRUCT 8"x8" CMU PIERS W/ (1) #5 BAR @ CENTER. SEE ARCH ELEVATIONS FOR HEIGHT. * = SPECIAL FILLED CELLS A ) ( B ) ( C --6" 1, 20' 0 6" _% , N� EW CMU FOUNDATION W LL T /SLAB r , _. s 10 11 1z _ ,...... o= F� E 1.3 2 CONTRACT R TO VERIFY FIELD saol S401 a o LOCATIONS OF EXISTING EMBEDS `li PRIOR TO GIRDER LOADS PROVIDE 2'- 0 "x2' -Ol' " SPREAD FOOTING W /•� ) #4 EACH WAY AT PIE . SET T /FTG 30" BELOW GRADE. Lo 0 3.3 4 (3) 1 3/4 "x9 1/2" LVL LINTELS AT (2) LEVELS BETWEEN WINDOWS BELOW ON (2) TRIMMERS. FILL WALL BETWEEN JOISTS TO DECK BEARING @ 99' -7" �—�TYP _r... 4" SLAB S S302 i 6x6 SYP #1 POST TYPICAL. I ARCH FOR SLOPE I r SEE ARCHITECTURAL FOR COLUMN WRAP. 4 S302 ill III . ,. ��k SCALE: 1/8" = 1' -O" NORTH