Loading...
HomeMy WebLinkAbout12033A7.7.pdf� a < a � MEDICINE CABINET TOWEL BAR LEVEL OF SHELF � SOAP DISH AT TUB� SHOWER (IF PROVIDED, — — AVOID CONFIJCT W/ BLOCKING OR GRAB TOILET PAPER BARS) DISPENSER MOUNTING FOR ACCESSORIES ELEC- SWITCH �THERMOSTAT WALL PHONE MOUNT 0 ELEC. OUTLET CAN OR CABLE JACK 0 _ o _ oo _ _ MOUNTING FOR ELECTRICAL MINIMUM OF ONE OUTLET PER LENGTH OF COUNTERTOP SHALL BE LOCATED 36" MIN FROM PERPENDICULAR COUNTER PER 1003.9. ELEC. SWITCH, OUTLET, PHONE '-0" MI� JACK OR OTHER DEVICE WITHIN 20"-25" MAX. REACH OVER TOP OF OBSiRUCTION (I.E CABWETRY) — o — —�� � �KITCHEN CABMET, BATH VANIiY OR SIMILAR MOUNTING OVER CABINETS NOTES: 1) MOUNTING HEIGHTS ARE BASED ON OBSTRUCTED AND UNOBSTRUCTED REACH REQUIREMENTS AS OURWE IN ICC/ANSI A117.U2��3 SECTION 308 & 309. 2J MOUNiING HEIGHTS SHOWN HERBN ARE FOR ALL OPERABLE PARTS, CONTROLS, DEVICES, ETC. WHICH REQUIRE THE USE OF A SWGLE HAND TO ACCESS�OPERATE. 3) HEIGHT REQUIREMENTS SHOWN HEREIN DO NOT APPLY TO SPECIAL EQUIPMENT OR ELECTRICAL/COMMUNICATION SYSTEM RECEPTACLES NOT NORMALLY IMENDED PoR USE BY OCCUPANTS. 4) OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING OR TWISTING OF THE WRIST. ACCESSIB�E MOUNTING HEIGHTS S�A�E ,iz..=,.-o END WALL FOR TYPE 'B' DWELLING UNITS FUTURE GRAB BARS GRAB BAR BLOCKING REQ'D. NO CURB HEIGHT REQUIREMENT SLOPE TO DRAIN I I 30"x48" CLEAR I FLOOR SPACE I — — — — — — — — — � P�AN 4 TOP LOADING MACHINE FRONT LOADING MACHWE TOP FRONT LOADING LOADING WASHER DRYER �-----��-----�I I �30"x48'� CLEAR FLOO�t SPACE I CENTEf�ED WASHER dR DRYER�I NorEs 1) TYPE 'B' ACCESSIBLE LAUNDRY EQUIPMENT TO MEET icc/nNSi nin.i-zoo3 s�cnoN iooaio. 2) TYPE 'B' ACCESSIBLE LAUNDRY AREAS ARE DESIGNED WITH CLEAR FLOOR SPACES IN ACCORDANCE WITH ICC/ANSI REQUIREMENTS (BASED ON APPROACH). 3) WASHER AND DRYER MAY BE EITHER TOP LOADING OR FRONT LOADWG. � ---- I I ----- WASHER/DRYER PLAN � ACCESSIB�E LAUNDRY EQUIPMENT SCALE- i/7�=�,_�„ LEVER TYPE FAUCET � STANDARD �,^ 0 0 CABINET a w� � � s �Q i � � o� / � � �� � ' � i om � / LAVATORY ELEVATION FOR TYPE 'B' DWEWNG UNIT$ NOTES. 1) iYPE 'B' ACCESSIBLE LAVATORIES TO MEET ICC�ANSI A1171-2003 SECTION 1004.11.311 AND 305-3- 2) TYPE 'B' ACCESSIBLE LAVATORY AREAS IN DWELLING I �30"x48" CLEAR I UNITS ARE DESIGNED WIiH CLEAR FLOOR SPACES IN I FLOOR SPACE I ACCORDANCE WITH ICC�ANSI REQUIREMENTS (BASED ON CENTERED ON I APPROACH). �_ __LAVATORY ___ J 3J M SPACES WHERE ONLY A FORWARD APPROACH CAN BE ACHIEVER LAVATORY MUST HAVE A REMOVABLE CABINET LAVATORY PLAN (SEE TYPE'A' DWELLWG UNIT LAVATORY DETAILS). � ACCESSIB�E LAVATORIES SCALE: 1/7'=1'-0 BACK WALL FOR TYPE 'B' DWELLING UNITS CONTROL WALL NOTES: 1) TYPE 'B' ACCESSBLE TRANSFER-TWE SHOWERS i0 MEET ICC/ANSI A117.1-2003 SECTION 1004.113.13.3. 2) GRAB BARS ARE NOT REQUIRED, PROVIDED REINFORCEMENT IS PROVI�E� IN WALLS TO PERMIT I I INSTALLATION OF GRAB BARS. I I 3) GRAB BARS QF PROVIDED) SHALL BE 1 1/2" DIAMETER I I w/ i i/2" e�eaeaNCe FeoM me wnu- 4J TWE'B' ACCESSIBLE SHOWER AREAS IN DWEWNG UNITS I 30°x60" CLEAR I ARE DESIGNED WITH CLEAR FLOOR SPACES IN ACCORDANCE IL FLOOR SPACE JI W� ICC/ANSI REQUIREMENTS (BASED ON APPROACH). — — — — — — — — — — 5) SHOWER CONTROLS TO BE LEVER iWE. 5-0" 6) SHOWER SEAT IS NOT REQUIRED, PROVIDED n REINFORCEMENT IS PROVI�E� IN WALL TO PERMIT PLAN iNSrn��nnoN oF sEnr. ACCESSIB�E SHOWERS (TRANSFER-TYPE) SCALE 1�2"=1'-0' FOR T1PE 'B' DWELLING UNITS STANDARD DISHWASHER (SEE UNIT PLANS FOR LOCATION) LEVER iME FAUCET STANDARD CABWET � I�_��_�I / \ � � ¢ �I$HWA$HER / A / A � \ / \ / o � / � � SINK ELEVATION � � / o 0 0 � i i� O O � / A I / \ STANDARD DISHWASHER (SEE� I I UNIT PLANS FOR LOCATION) I��30"x48" CLEAR � FLOOR SPACE I CENTERED ON I I SINK I � — — — — — — — — — � SWK PLAN � ACCESSIB�E KITCHENS J SCALE: 1/7'=1'-0" FOR TYPE'B' DWELLING UNITS FUTIRE GRAB �i I BARS --i-----�'�� I TOILET PAPER I DISPENSER� 48"x66" CLEAR FLOOR sancE (ns PEe icc/nNSi A117.b2�03 SEC. 1004.113.L2) L--------- ALT. PLAN SHOWER RC GRAB BARS WSTALLED LOCATE GR, (BLOCKWG) FRONT EDGI GRAB BAR REQ'D, O O � , I O � 30"x48" CLEAR� � FLOOR SPACE cENTERRONOE �IRANGE CLEARANCE I � ARALLEL APPROACH OP�ON FUTIRE GRAB I BARS I i01LET PAPER I DISPENSER 48"x66" CLEAR FLOOR SPACE (AS PER ICC/ANSI A117.b20�3 SEC. 1004.11.3.L2) L--------- FORWARD APPROACH PLA� FUTURE GRAB � BARS I TOILET PAPER I DISPENSER� aa"xss° aEnR F�ooR sPncE (ns PER icc/nNSi I A117.1-2003 SEC. 1004.11.3.L2) L--------- �1�111iI1»��7�9L1� � �I 30"x48" CLEAR� � F�ooR sPncE I eeNTeReo oN REFRIGERATOR CLEARANCE REFRIGERATOR I I � ARALLEL APPROACH OP�ON NOTES: 1� T1PE'B' ACCESSIBLE KITCHENS TO MEET ICC�ANSI A117.b2003 SECTION 1004.12. 2) TYPE'B' ACCESSBLE KITCHEN AREAS IN DWEWNG UNITS ARE DESIGNED WITH CLEAR FLOOR SPACES IN ACCORDANCE WITH ICC�ANSI REQUIREMENTS (BASED ON APPROACH). 3) STANDARD CABINETS AND STANDARD APPLIANCES MAY BE USED IN iYPE 'B' UNITS. 4) A MINIMUM OF 40" CLEAR SHALL BE PROVIDED BETWEEN ALL OPPOSING BASE CABWETS, COUNiERTOPS, APPLIANCES, OR WALLS WITHIN THE KITCHEN AREA. 5) A MINIMUM OF 60" CLEAR SHALL BE PROVIDED BETWEEN ALL OPPOSING BASE CABWETS, COUNiERTOPS, APPLIANCES, OR WALLS WITHIN KITCHENS WITH THREE CONTINUOUS SIDES OF COUNTERS, APPLIANCES OR CABWETS. GRAB BARS (MAY BE INSTALLED LATER) GRAB BAR BLOCKING REQ'D- � ACCESSIB�E WATER CLOSETS V SCALE: 1�2"=1'-0" FOR TYPE'B' DWELLING UNIiS END WALL GRAB BLOCK REQ'D. BACK WALL � 2'-0"" MIN � END Q z < � � � � � o M � WCREASED BLOCKING FOR FOLD-UP GRAB BAR REQ'D FOLD-UP GRAB BAR (REAR WALL MOUMED) 3"-0 MIN 0° MIN '-0" MIN � 4 � Q z � � � o � ALT. END WALL II FUTURE GRAB I � BARS I�60"x56° CLEAR FLOOR SPACE (AS PER ICC�AN51 I A117.1-2003 SEC. I iooaii 3.i.z) I L J FORWARD OR PARALLEL APPROACH PLAN A�T. P�N SIDE WALL NOiES: 1) TYPE 'B' ACCESSIBLE WATER CLOSETS TO MEET ICC/ANSI A1171-2003 SECTION 1004,11,3L2 2) GRAB BARS ARE NOT REQUIRER PROVIDED REMFORCEMENT IS PROVIDED IN WALLS TO PERMIT MSTALLATION OF GRAB BARS, 3) GRAB BARS QF PROVIDED) SHALL BE 1 1�7' DIAMETER W/ I 1/7' CLEARANCE FROM WALL 4) TYPE'B' ACCESSIBLE TOILET AREAS IN DWEWNG UNITS ARE DESIGNED WITH CLEAR FLOOR SPACES IN ACCORDANCE WITH ICC�AN51 REQUIREMENTS (BASED ON APPROACH�_ 5) FLUSH CONTROLS TO BE LEVER T1PE AND TO BE MOUNTED AT 44" AFF MAXIMUM. LEVER MUST BE ON THE WIDE OR OPEN SIDE OF THE FlXiURE. CONTROL END WALL ROD GRAB BAR VG) TO iDGE OF TUB NOTES: 1) TYPE 'B' ACCESSIBLE BATHTUBS TO MEET ICC/AN51 A117.1-2003 SECTION 1004.11.3.1.32. 2) GRAB BARS ARE NOT REQUIRED, PROVIDED REWFORCEMENT IS PROVIDED IN WALLS TO PERMIT WSTALLATION OF GRAB BARS. 3) GRAB BARS QF PROVIDED) SHALL BE 1 1/2" DIAMETER W/ 1 1/2" CLEARANCE FROM THE WALL. 4) TYPE 'B' ACCESSIBLE BATHTUB AREAS IN DWELLING UNITS ARE DESIGNED WITH CLEAR FLOOR SPACES IN ACCORDANCE IMTH ICC�ANSI REQUIREMENTS (BASED ON APPROACH). 5) TUB CONTROLS i0 BE LEVER iME. � �� HANDICAP CODE TYPE B UNITS (ALL FlRST FLOOR UNITS NOT HANDICAP CODE IYPE A) 0 1. ALL HARDWARE TO BE LEVER TYPE HARDWARE ANY LOCKING MECHANISM TO BE ACCESSIBLE PUSH BUTTON TYPE PER ANSI 1003.5. 30"x60° CLEAR I 2 REFLECTIVE SURFACE OF MIRROR TO BE MAXIMUM HEIGHT 40" AFF. �� �� ���FLOOR SPACE � 3. TOILET PAPER DISPENSER SHALL BE LOCATED 7" MINIMUM AND 9" MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTERLWE OF THE DISPENSER. THERE SHALL BE A � 0.EARANCE OF 1 1�2" MINIMUM BELOW THE GRAB BAR. 48"x60" CLEAR I � 4- ALL THRESHOLDS TO BE 1/2" MAXIMUM CHANGE IN LEVEL FROM TOP OF THRESHOLD TO �I f F�ooR sPnce � I PARALLEL APPROACH PLAN I FiNisHEO F�ooe oR Pn1io suRFncE. L J 5. TOILET CENTERLWES TO BE 18" FROM WALL MEASURED FROM FACE OF DRYWALL. 6. 37' CLEAR OPENING AT PRIMARY ENTRANCE DOOR. PRONDE 36" DOOR. I Z BE 31 3/4° CLEAR OPENING AT ALL PASSAGE DOORS PROVIDE 34" DOORS. I FORWARD APPROACH PLAN I 8. DOORS SHALL NOT SWWG INTO THE CLEAR FLOOR SPACE OF BATHROOM FIXTURES EXCEPT �------------ � WHEN A 30"x48" CLEAR FLOOR SPACE IS PRONDED BEYOND THE SWING OF THE DOOR. � ACCESSIB�E BATHTUBS W/0 PERMANENT SEATS SCALE 1/2"=P-0° FOR T1PE'B' DWELLING UNITS 2E GRAB BAR <ING REOb. CERTIFIED BY E E v o0 � � s �� �� ` L L U U �^ O 6 � N N �� d � M �] 1] (v�1��� � N VI rn O 3 7�7 N � 3 � � d � • �,� o, \ ` o _ Q �N � � ��o= � � � I m w � � �n a' � �� o 0 � � ` o � o Fi � � o � N I � � ` � I /� /� � N N v � \ N n � �l � ao � � H > v ! w o d vJ ° � o x � s a rn d � J L Q U O Z Of^ VJ wf^ VJ W 2 � J W � � � O W Q � O Z + � w �J � W� W � U Q 3 m �111111 �111111 ��,,,,,1 DATE DRAWN BY 01�23�2014 RMM PROJECT NO- CHECKED BY 12033 KAS DRAWING SGALE PLOT SGALE AS NOTED 1:1 FILE NAAnE 12033A7J ANSI TYPE 'B' UNIT DETAILS SHEET N�. A7.7 sHCCr or