HomeMy WebLinkAbout05-28-2014 Revisions pg 2SOIL AND WASTE PIPE SHALL SLOPE 2% MINIMUM, UNLESS OTHERWISE NOTED OR REQUIRED BY CODE 2. ALL DRAWN WATER & GAS LINES SHALL BE KEPT TIGHT TO THE UNDERSIDE OF EQUIPMENT & SECURED IN PLACE. 3. VERIFY THE LOCATION OF THE EXISTING SANITARY SEWER ON THE EXISTING SITE/ BUILDING PLANS AND IN FILED PRIOR TO BID SUBMISSION, REVISE THE SANITARY & GREASE SEWER SYSTEM AS REQUIRED. 4. PROVIDE TRAP PRIMERS FOR NEW FLOOR DRAINS INDICATED, WHERE REQUIRED BY CODES. PROVIDE DEEP SEAL TRAPS FOR FLOOR DRAINS WITHOUT TRAP PRIMERS. 5. ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. THE CONTRACTOR SHALL COORDINATE ALL CLEANOUT LOCATIONS WITH EQUIPMENT, CABINETS, ETC. AND THE OWNERS REPRESENTATIVE PRIOR TO ANY INSTALLATION. 6. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE NON - ACCESSIBLE CEILING SHALL BE INSTALLED BEHIND AN ACCESS PANEL. 7. ALL PLUMBING FIXTURE VENTS SHALL TERMINATE A MINIMUM OF 12 INCHES FROM ANY VERTICAL SURFACE AND 10 FEET FROM ANY OUTSIDE AIR INTAKE. 8. PROVIDE GAS PIPING TO NEW EQUIPMENT AND ALL FINAL CONNECTIONS REQUIRED FOR OPERATION, 9. INSTALL SHUT -OFF VALVES ON ALL HOT & COLD WATER LINES TO FIXTURE OR APPLIANCE. ALL EXPOSED WATER AND WASTE LINES TO BE CHROME PLATED. 10. PROVIDE A LEVER HANDLE GAS SHUT -OFF VALVE IN THE BRANCH PIPING OF EACH APPLIANCE OR PIECE OF EQUIPMENT, FOR EACH APPLIANCE INSTALL QUICK DISCONNECT, FLEXIBLE PIPE WHEN ALLOWED BY CODE AND RESTRAINING DEVICE FURNISHED BY OWNER, PROVIDE PRESSURE REDUCING VALVES AT EACH PIECE OF EQUIPMENT OR APPLIANCE. IF GAS PRESSURE GREATER THAN 107wc IS USED DOWNSTREAM FROM THE GAS METER. 11. ALL VALVES, UNIONS, ETC. SHALL BE SAME SIZE AS PIPE UNLESS OTHERWISE INDICATED ON DRAWINGS. 12. REFER TO KITCHEN EQUIPMENT DRAWINGS FOR PLUMBING ROUGH -IN SCHEDULE & FOR ADDITIONAL WORK TO BE FURNISHED & INSTALLED BY CONTRACTOR. ALL ROUGH -IN PLUMBING AND FINAL CONNECTIONS TO KITCHEN EQUIPMENT SHALL BE MADE BY THE CONTRACTOR U.O.N. 13. REFER TO MECHANICAL SHEETS FOR HVAC AND HOOD PLUMBING REQUIREMENTS. 14. ALL GAS LINES SHALL BE SUPPORTED SEE SPECS. 15. ALL FLOOR SINKS AND FLOOR DRAINS IN TRAFFIC AREAS SHALL BE INSTALLED FLUSH TO FLOOR SURFACE. 16. PROVIDE WATER HAMMER/ SHOCK ARRESTOR FOR ALL HAND SINKS AND WATER LINES. 17. PROVIDE AIR GAPS FOR INDIRECT DRAINS AS REQUIRED BY CODE. AIR GAP SHALL BE MINIMUM 2 TIMES THE DIAMETER OF THE INDIRECT DRAIN. 18. PRIOR TO COMMENCING WORK ON THIS PROJECT, VERIFY DEPTH, SIZE, LOCATION AND CONDITION OF ALL EXISTING UTILITIES IN FIELD. SHOULD CONDITIONS EXIST OTHER THAN THOSE INDICATED WHICH WOULD CAUSE THE DESIGN TO BE ALTERED, CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY. 19. COORDINATE INSTALLATION OF PLUMBING WORK WITH ALL OTHER TRADES SO AS TO AVOID UNNECESSARY DELAY OR INTERFERENCES. CONTRACTOR SHALL REVIEW ARCHITECTURAL AND EQUIPMENT SHEETS. 20. FURNISH & INSTALL ALL BACKFLOW PROTECTION DEVICES REQUIRED BY AGENCIES HAVING JURISDICTION. BACKFLOW DEVICES REQUIRING TESTING SHALL BE INSTALLED NO HIGHER THAN S -0" A.F.F. EXISTING EUIPMENT TO REMAIN. 21. PROVIDE CONDENSATE DRAIN FROM COOLER/ FREEZER TO APPROVED DRAIN, 22. THE OWNER OR KITCHEN EQUIPMENT SUPPLIER MAY SUBSTITUTE EQUIPMENT OR THE EQUIPMENT MAY VARY FROM WHAT IS SHOWN, THEREFORE, VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR, 23. ALL WATER LINES SHALL BE RUN OVERHEAD U.O.N. 24. ALL WATER LINES SHALL BE FLUSHED PRIOR TO CONNECTING ANY FIXTURES OR EQUIPMENT. 25. PROVIDE ESCUTCHEON PLATES AND SILICONE SEALANT AT ALL UTILITY PENETRATIONS INTO WALLS, CEILINGS, AND FLOORS. DO NOT USE CAULKS OR EXPANDING FOAMS FOR SEALANT. 26. CVPVC SCHEDULE 40 WASTE PIPE CAN BE SUBSTITUTED FOR BLACK IRON WASTE PIPE WHERE ALLOWED BY LOCAL MUNICIPALITIES. GENERAL NOTES I D ARCHITECTURE CONSTRUCTION MANAGEMENT DEVELOPMENT THE D 7'� DESIGN GROUP 1104 S. MITCHELL ST. CADILLAC, MICHIGAN 49601 (231) 779 -4002 (231) 779 -4022 FAX WT DEVELOPMENT CORPORATION WT Deve ®iIn1Z rporation 10223 E. Cherry Bend Rd., Ste. A Traverse City, Michigan, 49684 Contact: Bill Beckett, President Phone: (231) 922 -9250 Fax: (231) 922.9257 PROJECT CONSULTANT 08��' m WAM0600064 0 STATE OF 10 0G�O000, ® ® ®_ 512811 � 8ou 02.11.14 Landlord Review A04.09.14 WALL SIGN REVISIONS A04,25.14 FOR PERMITS & BIDS A05.06.14 TENANT SEPARATION ' 4 05.13.14 BLAZE REVISION TOTAL H.W. WATER CLOSET STORE NUMBER: 10 BLAZE PIZZA Carmel Corners Meijer Outlot'B' 12697 N. Pennsylvania St. Carmel, IN 46032 FIXTURE NO. DRAIN COLD WATER HOT WATER D.F.U. TOTAL D.F.U. F.U. C.W. TOTAL C.W. F.U. H.W. TOTAL H.W. WATER CLOSET 2 4 8 2 4 URINAL LAVATORY 2 1 2 2 4 2 4 HAND SINK 2 2 4 2 4 2 4 PREP SINK * 1 1 1 2 2 2 2 3- COMPARTMENT SINK * (GREASE WASTE) 1 1 1 3 3 3 3 HOSE BIBB/WATER FILTRATION UNIT FLOOR DRAIN 8 2 16 -- -- - DISHWASHER 1 2 2 - - 2.25 2.25 FLOOR SINK 3 6 18 -- -- -- -- MOP SINK 1 3 3 2.25 2.25 2.25 2.25 TOTAL - - 47 19.25 17.50 PROBABLE DEMANDS/ AND PIPE SIZING REQUIREMENTS: COLD WATER: 19.25 FU = 15 GPM DRAIN: GW 3 DFU DRAIN: SAN 44 DFU HOT WATER: 17.5 x 3/4 =13 GPM USE 1 -112" CW SERVICE USE 4" SANITARY (MIN) USE 4" SANITARY (MIN) USE 1 -1/ 4" HW SERVICE (MIN) BASED ON 2009 IPC (COMBINATION DRAIN & VENT). *FIXTURE HAS INDIRECT WASTE TO FLOOR SINK FIXTURE UNITS SCHEDULE I G PLUMBING SCHEDULES P1.0 PROJECT NUMBER: 14106a