HomeMy WebLinkAbout05-28-2014 Revisions pg 3WASTE & VENT PLAN 1/4 " = " -0" O ASSUMED LOCATION OF EXISTING 4" SANITARY PIPING TO REMAIN. FIELD VERIFY PRIOR 11 COORDINATE GREASE WASTE & SANITARY PIPING CROSSING. TO THE START OF CONSTRUCTION. OPROVIDE INSULATED CONDENSATE LINE AND DRAIN LINE FROM ICE MACHINE TO 2 FLOOR SINK, PROVIDE AIR GAP PER LOCAL CODE. OPROVIDE INSULATED WASTE LINES FROM BEVERAGE UNIT TO FLOOR SINK, PROVIDE AIR GAP PER LOCAL CODE. PROVIDE 3/4" COPPER CONDENSATE FROM COOLER /FREEZER EVAPORATOR DRAIN O PROVIDED BY VENDOR TO OUTFALL TO HUB DRAIN HD -1 (HEAT ROPE IS SUPPLIED WITH FREEZER CONDENSATE). PROVIDE AIR GAP PER THE INDIANA PLUMBING CODE. O5 APPROXIMATE LOCATION OF NEW 3" VENT THRU ROOF. VERIFY INFIELD. G.C./ P.C. NOTE: ENTIRE RUN OF DRAIN LINES TO INLET OF EXTERIOR GREASE INTERCEPTOR AND © OUTLET OF INTERCEPTOR TO CONNECTION AT SANITARY MAIN SHALL BE SCHEDULE 40 PVC DWV OR AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. INSTALL OUTFLOW RESTRICTION TO LIMIT DRAINAGE FROM 3 -COMP. SINK TO A MAXIUM OF 40 GPM. ONEW FLOOR CLEANOUT AT EXISTING 4" SANITARY & GREASE WASTE LINE AS SHOWN. FLOOR CLEANOUT, FCO -1 TO BE ACCESSIBLE IN AREA BEYOND NEW COOLER/ FREEZER. ® PIPE WASTE FROM 3- COMPARTMENT SINK S3 TO FLOOR SINK WITH AIR GAP PER CODE. ONEW 2" PVC SANITARY SEWER FROM NEW S1 HAND SINK TO BELOW SANITARY PIPING, COORDINATE TIE IN LOCATION ELEVATION WITH OTHER PIPING. 10 PROVIDE AND INSTALL CONDENSATE DRAIN FROM ABOVE INSTANTANEOUS WATER HEATER(S) TO FLOOR SINK FS -1 @ S -4 BELOW IN WALL. INSTALL DRAIN PER MANUFACTURER'S RECOMMENDATIONS, " 0. M.. CDRUN 2" DRAIN LINE FROM DISH WASHING MACHINE EXPOSED BENEATH ADJACENT EQUIPMENT TO OUTFALL AT FLOOR SINK BENEATH 3- COMPARTMENT SINK S3. 13 APPROXIMATE NEW/ EXISTING SANITARY & GREASE WASTE TIE -IN LOCATION, VERIFY IN FIELD. 14 DRAIN FOR WATER FILTER, TO HUB DRAIN HD -1, 3" SANITARY 15 NEW MOP SINK S2. (aD NEW FLOOR DRAIN WITH TRAP PRIMER. 17 EXISTING FLOOR CLEANOUT(S) & MAIN LINE VENTING TO REMAIN ASSUMED LOCATION OF EXISTING 4" GREASE WASTE PIPING TO EXISTING 18 INTERCEPTOR. PLUMBING CONTRACTOR SHALL VERIFY EXISTING SIZE WITH LOCAL HEALTH DEPARTMENT HAVING JURISDICTION. (aD PIPE WASTE FROM PREP SINK TO FLOOR SINK WITH AIR GAP PER CODE, 20 HUB DRAIN HD -1, 3" SANITARY FOR COOLER/ FREEZER CONDENSATE, IN WALL. 21 NEW 4" PVC SANITARY WASTE LINE FROM WC -1 AND 2" PVC WASTE LINE FROM L -1 TO NEW SANITARY WASTE LINE. 22 T VENT THRU ROOF, 23 NEW FLOOR DRAIN WITH -IN 3-0" OF COOLER DOOR, PER CODE. KEY NOTES ARCHITECTURE CONSTRUCTION MANAGEMENT DEVELOPMENT E DESIGN GROUP 1104 S. MITCHELL ST. CADILLAC, MICHIGAN 49601 (231) 779 -4002 (231) 779 -4022 FAX WT DEVELOPMENT CORPORATION Q�� WT Deverb�Znirporation 10223 E. Cherry Bend Rd., Ste. A Traverse City, Michigan, 49684 Contact: Bill Beckett, President Phone: (231) 922 -9250 Fax: (231) 922 -9257 PROJECT CONSULTANT wo ® ® ® J 60- � NO- ARIOS 4° - -� o STATE OF Wit —000 a 000 02.11.14 Landlord Review A04.09.14 WALL SIGN REVISIONS ©04.25.14 FOR PERMITS & BIDS ©05.06.14 TENANT SEPARATION 4 05.13.14 BLAZE REVISIONS STORE NUMBER: 10 BLAZE PIZZA Carmel Corners Meijer Outlot'B' 12697 N. Pennsylvania St. Carmel, IN 46032 SANITARY PIPING PLAN P2mO PROJECT NUMBER: 14106a