Loading...
HomeMy WebLinkAbout0866.2002 Revision Info , . .,,; 1 :�.y-°F �����, �� , ��` ���� �� ��.r��� ,� =�.�: �tit. ,o,:� ,.9'.,.. .,�,:,. -"�roN�°:' ' ' DEPART�tENT OF ENGINEERING July 29, 2002 Mr. Ron Wilder Beaman Associates, Inc. 5105 Madison Avenue Indianapolis, IN 46227 RE: Stewart& Stewart,931 S. Rangcline Road/Project Revierv#2 DearMr. Wilder. The Ciry Engineer,Kate Wcese,is out of town and will not return until Friday, August 2. Sl�e has not been abie to revic�v the rc��ised dra«�ng and response letter dated July 24, 2002. Ho�eever,I}wve notified City of Cazmel Buiiding and Code Enforcement tliat they may proceed and schedule the pre-submittal meeting. However,we have asked that�he building perniit not be issued until Ihe City Engincer has reviewcd and approved the plans for this development. In Kate's absence,I havc reviewed the revised dra��ing and offer the following addi[ional comments: Praiect Comments Item#> -Arc tl�cre dedicated easements on the property? If so, they should be indicated on all plans. . There is a]0'Drainage Easement indic�ed alang the south und ea+t property lines. Hoivever, the easement along the east property line ea�tends nnrth}vard only halfivay. Do you have injormntion regnrding ihe dedicrnion ojihese easements or the reason rvhy this easement ivus not extended? The original plat(capy r4tnched)only shows the 4' Uti(ity EasemenG . There is reference to a cross easement on the sheels. Whqt is this in referexce to and ivhere is the easement loeafed? Drainaec Conccrns Item#10 - All storn�sewers within the Rangeline Road right of way should include pipe sizes/slope and all swctures should indicate TC and INV elevations. . 7he pipe sizes jor the storm se�ver in Ihe Range I.ine Road right of ivay have nof been indicaled us reque.�ed . The inveRjor the vxisfing.+Trudure in the yarking!at is greater(847.65)than fhe inveR on tlie first.ne�v s[ructure being insfa((ed soulh ojthe ezis[ing.�tructure(SJ1.60).Reverse slopes are not ucceptable. . The inverls jor the eYisYing struMUre adjacent to attd south ojfhe north entranee in the Range /.ine.Road right ojivny are dijjerent on Sheet S] (836.77)and Shed S3(836.67). N'hich is tlee corred inverf? ljthe 836.77 invert is corred, if nnuld appear t6ere is a fTrR s(ope bebvecn ihis structure und the ned existing siructure t�the north. . 7he eri.rting strudures nnd pipes indieaterl onlhe drmving do not shmv nn outlet jor the storm drninage from tke site. T'he nee[e�is7ing sTructure that.this site ivill outlet to should he indicuted ort the drmving including qie Top ojCasting and lnvert E(evations(rejerence the uKachment). Item#I 1 -No detcntion is sLown. From a visual inspection,the site appcars to have a small dry detention area. Since there are gnss arcas to bc paved as additional parking, we request tliat you provide additional storm infonnalion. . The Ci1y Engineer ivill revic�v the drninage ca(cu(ntions provided - ONF. CIVIC SQUAR[ CARMEL, It�'DIANA 46032 317/57l-2441 / Ivfr. Ron,Wilder Iuly;29, 2002 Page 2 Other Please provide a Title Sheet foi Uie drawings including the project name and address,location map and all other ifems[ypically provided on TiUe Sheets. When the City Engineer approves the dtawings for tlus project�we will require five-sets of cepified consWClion d�awings(civil). The City Engineer and Utility Director will sign the diawings. One signed and approved setmusTbe maintained on Uie consVuction site at all times. One set is given to our public works inspector,two sets aze give to Carmel Utilities and one set is maintained in the Department of Engineering. The City Engineermay have additional comments regazding tlie revised drawing provided. If you have questions,please feel free to wntac[Kate Weese,Mike McBride or me at 571-2441. /Sincer�L I/�9" in Dick Hill, Assistant Director Department of Engineering Cc: Kate Weese, City Engineer Mike McBride,Assistant City Engineer Jon Dobosiewicz,Department of Communiry Services John Duffy; Carniel Uulities Jeff KendalUGayle Sta}il, Building& Code Enfo;cement S:\VROJRE V02\STEW ARTLAW�2