HomeMy WebLinkAbout2nd Floor Life Safety2 3 4 5 6 7 8 9 10 P—A CODE SUMMARY LIFE SAFETY NOTES GENERAL NOTES SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE OCCUPANCY CLASSIFICATION BUSINESS) CHANGE OF OCCUPANCY CLASS? NO TOTAL BUILDING AREA 34,045 SF /FLOOR X 1 2 STORIES = 68,090 SF TOTAL PROJECT AREA OCCUPANCY CALCULATIONS NUMBER OF REQUIRED EXITS 14,508 SF SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD GEN. OFFICE 12,780 SF 100 128 CONE ROOMS 1,728 SF 15 116 FE FIRE EXTINGUISHER TOTAL OCCUPANTS IN PROJECT AREA 2 244 SPRINKLER SYSTEM (YES /NO) YES - EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 1,728 SF TOTAL AREA ON THE FLOOR 34,045 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND /OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A LEGEND 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS /STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN /BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER /LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. L1. REFER TO SHEET Al 11 FOR WALL TYPE AND CONSTRUCTION DETAILS L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. Q) )CNOON o N L p r— E -9 N N N N c00 0 3 .a N co THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. EP EXISTING ELECTRICAL PANEL LOCATION 0 W EX EXISTING EXIT W FE FIRE EXTINGUISHER y 1 N EXIT SIGNAGE Z O EMERGENCY LIGHTING J Z w Z� W Z U O � 0 ® FE _ A ED J AREA NOT IN CONTRACT ❑ AREA OF WORK LIFE SAFETY PLAN N 0 4' S' 16' ISSUE DATE DESCRIPTION 04.23.14 1PERMITSET REVISONS MARId DATE I DB IDESCRIPTION H B0 No. AR10700017 ,_ s %c" STATE OF V: - mew ■■ PROJECT NUMBER 2014.125 PROJ. MGR DRAWN BY ACM AS 2ND FLOOR LIFE SAFETY L100