CODE SUMMARY LIFE SAFETY NOTES GENERAL NOTES
SCOPE OF WORK
OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE
OCCUPANCY CLASSIFICATION
BUSINESS)
CHANGE OF OCCUPANCY CLASS?
NO
TOTAL BUILDING AREA
34,045 SF /FLOOR
X
1 2 STORIES
=
68,090 SF
TOTAL PROJECT AREA
OCCUPANCY CALCULATIONS
NUMBER OF REQUIRED EXITS
14,508 SF
SPACE TYPE AREA SF PER OCCUPANT
OCCUP LOAD
GEN. OFFICE
12,780 SF
100
128
CONE ROOMS
1,728 SF
15
116
FE FIRE EXTINGUISHER
TOTAL OCCUPANTS IN PROJECT AREA
2
244
SPRINKLER SYSTEM (YES /NO)
YES - EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES
1,728 SF
TOTAL AREA ON THE FLOOR
34,045 SF
ACCESSORY AREA EXCEEDS 10%
NO
FIRE WALLS, AND /OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
LEGEND
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED
TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE
CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR
REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS /STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER
REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL
APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL
FIRE CODE, NFPA).
3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN /BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE
DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10.
COORDINATE WITH OWNER /LANDLORD ON EXTINGUISHER TYPE AND
HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO
A VISIBLE EXTINGUISHER.
L1. REFER TO SHEET Al 11 FOR WALL TYPE AND CONSTRUCTION DETAILS
L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS,
FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO
REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS
AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND
STATE CODES.
Q) )CNOON o
N
L p r—
E -9 N N N
N c00
0
3 .a N
co
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
EP EXISTING ELECTRICAL PANEL LOCATION
0
W
EX EXISTING EXIT
W
FE FIRE EXTINGUISHER
y
1
N
EXIT SIGNAGE
Z
O
EMERGENCY LIGHTING
J
Z
w
Z�
W
Z
U
O
�
0
® FE _ A
ED
J
AREA NOT IN CONTRACT
❑ AREA OF WORK
LIFE SAFETY PLAN N
0 4' S' 16'
ISSUE
DATE DESCRIPTION
04.23.14 1PERMITSET
REVISONS
MARId DATE I DB IDESCRIPTION
H B0
No.
AR10700017 ,_ s
%c" STATE OF V:
- mew ■■
PROJECT NUMBER
2014.125
PROJ. MGR DRAWN BY
ACM AS
2ND FLOOR
LIFE SAFETY