HomeMy WebLinkAbout04040166 Sewer `
" �� . CLAY TOWNSHIP REGfONAL WASTE DISTRICT
' .SP�NITARY;SEVN'ER PERMIT
[ .]!'Conditiorial Pe�irii£ [ X. ];Final Permi4
INDIVIDUA'L`LOTS/EXIST.ING;BUILDINGS
�ProjectTitle; CIay�WasteWesl
;Lo6ation: AsHbury�Park.
'Owner78uiliier: Preceiient':Homes '
Lot#'49 Sfreet ad'd�ess: 13509 Belford;Ot
�
'°- �—<- �_ Cit CarmelL -- , 7'
- � - — ,y_f = _-. - p;46032�, _ _ Gounry Namilton _ �
Inte�ceptor ChargesPaid: PRI';� L'OC: EDU Fee:T;200.00 Appiication fee:n75.00`
PL'EASE NOTE Installation of,bwlding sewer sliall 6e per thie specifications of the�,Clay Townstiip;
Regional'Waste Distnc4:(see rever5e)and any,conddions noted below All�i`nstallations,sfiall'be inspected"by District
��`personnel d"u��ing open t�ench!'�phase;and 6�efo�eibackfllirig''witho'sanii or stone torsix+,inchesEabove;the>pipe::NO�
footing or�founcJation drains or,othersources of;ground o�stormwater,shall fie permitted'to ente�the?.Dist�ict's.
sanitary'sewer-system. The DistricYwill assuFne no Iia6ilitv�fo��drains whicFi�are below:the qrade level`of.the
�nea�est"dowhst�eam"inanhole.noF=fo�laterafs wfiicfi are eztended beneatfi dri4ewa4s or-''sidewalks Tlie
permiNholder(p'roperty^owne�„developer or,builder)willitie�responsi6le for damages to;the;Distnct s�sewer�sysfem'„
Tfi'is includes damages to:manholes, castings; manhole limds and,the like; causetl;by construction�activitypn the
building site wFnch'is the+sub�ect�of this permit:
Inspectionsiby,the`Dist�ict.are:MANDqT.ORY and sfiallbe,arr`anged by contacting;tfie;Di`stricfs.office aL844e9200
24;Rours,in ativance. Alf,`new.construction:will be placed;on billing=six,monthsafte�connection,fias�been made or`
when;wate�'i's connecte0,�wfiiche'v'er-,comes�fi�st
����- Dist�icf"will inspecUalllsump pump,connectioris 30 to 60;days�afte'r-the:lateral inspection has 6een
completed., "
�% I have:recerved a copy of Qrdinance'No 9 13-99:and agree,to.follow all District sfandards Building
has=a [x] crawl space,,['] slab or,[ ].basement that[ ;]will be fnished;[ :]rough;in`plumbing with, ria ndec
pump mstalled durmg construction [ ] rough in plumbing only and,q�inder pump will not be mstalled
du�ing const�uction„`[ ,] no plum6ing m 4he;basemenf.� (Please check:appropnate bo_x?) Builder will notiN
��the District�`officeAwhen'the qrinderpump°installation°is complefed �
Conditional PermiPTerms:
[,. ]' ;NO':GONNECT.ION to the sewer until;fu�thed notification.
[ "] Certificafe of3nsu�ance must,6e onifile!witfikCTRWD li§ted�as certificate;fiolde[.
[ ;] 48,hou�s`notice�6eto�e`wo�k starts on;manhole�co[e drilling;o�,cuts;of actiJe lines
and,District`inspecto�must,inspect all wo�k before covered,;
[, `] All District fees will be paid in;full'. �,
[; ] Approval_pending'p'istnctsireview of plans.
_ � .� ,_
["; ] Copies of�,approved;permits',from"app�op"riate county'o�city agencies�for worksin
the right;of-way'road cuts.oc are requyedp �
.. _ ._.
[ ] No occupancy _until'further'notification
�.
I1
All Gonditions'have 6een�met and#inaf�permit+issued 2009`..
'B'y•signing below„'I attest�:that I+am:familia�-witFi thie�pistrict!s specifications antl+ag�ee to,accepf;responsibiliry fo��all
worktd'one under,this.permit,
C� ' ,
� � �,,�' �`�tM1�����'^\ 566-1330
BuilcJer/Owne aSi natu�e �Pli'one '
��:�� �s 1�i y,�.
Printed Name: .
Pe�mit issued this 21"cJay of April; 2004. ves 2�site plans:subrriittetl
o��Np1ANA•p,���l
rONE-YEAR from;the date;rssugd: �`� �y
PermitEis valid fo _ _ y c '
� �o
/:. . ,y_ � ����D K
.C.:!,.--„ r—
`���:_.,� � � . �r
��,:.. � �—__�— �.
Candy J Feltner:% �; 5.(�
Manager of Administration 'yia O�
9FG/ONALWP`'�
iS_;t^-+-w
Pe�mit`;valid"onlywitl�CTRWD seal in';red,ink:,
PeFm it-r`eG:01/031akn`
y
,r-,� _�
CL'AY'TOWNSHIP�REGIONAL�WASTE DISTRICT'
. . �
' iSLIMMARY'OF�LATERAL'INSTALLATION'�RE(QUIREMENTS�
for Hamiltonbutldin s;etc.-,shall`connect�toslhe�DislricPs samtary�,sewer sys�em`�within 90�days;of notice�.providing a sewei is within:3001fee�.
1�. All houses N � _ _ K . . ,
'Cou4nw or 100 feet(or BooneLount ;of,the� ro eity�lirie. Only one�buildmg,may;connecl to:tFie sewer main,per lateral uniess,
9
h'- Y P P
otherwise appro'ved by Ihe��.District � � �� '��- - �
2. No,foundation orother storm water'drains-shalC;be,interconnected'�.to the seyveclater'al installed�and��;connected�td�.tfie District s samtary'.
sewe}.
— _
. 3.. The;existing sewer IineSrom the bwlding to the septiclank may,oniy be used if il�is IocatetlLntler a buiiding�addjhon;patio„porch or paJed
dnveway.,Airtestisrequired toshow.ifaccepta6le'for,re-use. TFie.propertyownershalljbearylhewstpf;all�festing.. 'The��Disirictinspector
musbbe'onsite.for lhe'duration of the'2i��tesh: � - - ` - - - --
' �4.. The��owner,oc.conlFactor shall nohfy:the Dislnct pnonto,covenng!ihe.�installed,lateral so that tfie District can make�an inspection to�determine�
compliance,with the Distnct s sewer use,ordinance..5uch notifcation shall be:maiie 24 houis,pr�onto the�,need tor the;ingpec6on•�If-tlie� - ° -
_ _ _ _inspection;fails and a second inspection'is requ�eilg�oycontractor;isnot on site for schedNed'inspection,[o�,fails to�:cancef.inspectron;;an
` ` addiUonaLfee of$75.00 wi�l be due Thismust be��paid�prioo;�o:the�time'of ihe�.follow,up inspecfiorr..
15i, Property,owners'are heretiy advised thal Ihe Counry;8oard�of Health regulates.the operalion and mamlenance of pnvate sewage disposal
• (sephc)systems The County Ordinance prowdes.impart lhat;aupon connection`.Eg a public.sewer a septic tank'. shall��6e abandonedand
�c��� .
'flled wdfi earthen mate"risf;in a safe andisanitarypmarioer.' Piea`se contecl lhe appropnale County Boaid;of�Neal'thlforTi�rthe[mformation.
�6� Acceptalile�.Pipe.Malerials: �
PVC��PIPE: :SDR'35,�AS_T,M D-3034„SIX�INCH'PIP.E.
PVC�PIPE: �SDR 21�,:ASTM D-2f41,SIX INCH PIPE � �
GASKETS�-JOINTS AS.T,fvl D�32�12
`GAS KETS,ASTM i F-477�
. FITTING5-��,SDR=�26 ��
„ , 4 ECHANICAL CQUP�LING WITN PROP„ER�-EITTINGSi
�..�.
D OCF..E TIAP RT'BE L''OCATED THREE FEET WITHIN THE�FOUNDAT,ION ANDINO MORE�THAN
CLEAN OU7S TO
�,7. Bedding�
l�Jse fll sand!,or��Number<8,9�or�1�1 stone
��Fill material•is�to Be placed from�6'inches below�to 6linches above thetipipe
The;trencfi�should;be;a�minimum'of�18 incfies�:wide ��
, .installation. � P P ;unless PVCpressure grade pipe is used meelmg SDR;21'and ASTM D-
II: �,2241raISA'nhall be_installed,n_o closer than'�20 feel from�;waterwellsreJiewed andlaccepted bytfie Distnct and+the Dishicts�.engineer< rip Of.�O�
y�proposed'installatron reqwring pressure i e shall be .
9':. Where a�transihon is rriade'beMieen'SDR 35 pipe�and�pressuregrade�SDR 21;pipe a ductile iion�gaskeledimechanical'couplingsfiali be
., used: . ._. � . . . . � � . ._ _
10: Late'rals shali`terminate wilFiin 3:feefof,the 6uilding�unless,the conditions m��.ilem,#3�,above are�mel� No�dlued'pioe'sBall�6e'installed'outside
� 'of.buildinq foundalion�.walls. � � " -� �"�- � "- � � -
- :1�1�. ,Addihonal�.informahon`on Distnci standards and,tspeciFlCatipns��:may.�be obtained'trom the�Districls offce'duiing;6usiness hours of,:8:00a�.m.
to 4.30�p:m:Monday;thiough Friday;Ali,Disinct standards'.cambe Iocated on qurweb site;a4.hfto'//wwwctiwd'om7.�
Clay Townsfiip Regibnal,Waste District
10701 NortFi;Coilege;Suite%Q.
Indianapolis,;indiana�46280�
_ Phone:;f3,44-9200 �Fax;i644:-9203� .
- ..
� 12:.�..Sephc effluent sliall riol'.be�.pumped,'out in[o°lhe�.sanitary.sewe�"syste`ml.
13;,;TRe`Aistricf�shall ineaect�ALL lateralst Please'callietlie Dis"tricPgffce at-844.920024ihours.pnorto hme'of,inspectipn�.
�`I4: ,Contractors��shall lav 14'oauqe-stranded wire the�entire lenqthaf the late�al. Wire is:to�be placedlon�,top of�the�lateral. �The DisMct
'��inspector.will��,verify placement of the;wire After;inspection :bediiin�is to'be.placed qn,top_ �-
��15i 'Call before!you dig�i IUPP.5,1 800;382-5544,48�hours!pnor toftliggirig_
�.Lateral<rev:04�;01c(..
��
e�,n11' Q10"7''O
7;�• �Q�
� ���d��� �
�� 0�.
aT,>�YJ -,F�
�,.
,. _,
CONSULTING ENGINEERS JOBID ASPK.49
L , A N D S U R V E Y 0 R S
99d� Aliisonville-Rd.•Flshers, IN 46038 � CONTROL # 4g108 PRECE
(311) 849-5935 • 1-800-728-6917 � FAX: (317) 849-5942
(PIN)
THE FOOTINGS� FOR THIS HOUSE SHOULD BE 13509 BELFORD COURT
P.INNED SINCE �THERE IS LITTLE OR NO TOLERANCE
� ON THE BETWEEN STRUCTURFS.
E 77.4
P 77.4' .
-b76i6
.:PJB.6� , rJ6?�2
�
E 77.6
� P 77.8
v
j 2�.��
E 77.1 E 78.4
P77.7 ° P79.4
� PATIO .
q6.6i2
f�79A .�y5 . '3'y 2s.75
P79.4 2.49 2.M19 '
5.0 °
o p
n H
w mL
�-1.83 -�
� 1' = 30'
� �
N F.F.ELEV.� aeo.o� � �'� LOT AREA: 6,856 Sq. Ft.
0
0 o O
o m
� i o o'
LEGEND:
._ --1 E 99.89 EXIS7ING GRADE (BEFORE CONST.)
0 6.00 0 f
m ,� } FROP. P 9H.99 PROPOSED GRADE (AFlER CONST.)
S.DOa OR � ,67 I HSE
I E 78.4 - S�S.D._ _SUB-SURFACE DRAIN .
P 78:4
23J � SANITARY SEWER
��9•4 -STORM SEWER
E77.9 �I M CoNG . P79.4� W WAiER AIAIN
P��y GARAGE N ORIVE
879.73 E78.2 W �3/4' WA7ER CONNEC710N
E 79.4 - �° � P 78.2 -e•• ' SWALE
p�g q 10.67ni �. 1; SF 9l7 FENCE
_ y - �
E77.7 yi f � 75�� � . � W � SEWER MANHOLE
P 77J ti ° c' � � � \ .
� �s \� �J STORIA MANHOIF
2279Na'SW � / �
�A � CURB INLET
' � aa � � FlRE HYDRANT
w BEL ORD "Y°
o C O T � I LE.0 E LAN SCAPING E 5 MENT EIAENT
P 77.44 p 7g,02 p 7e QZ � S.I.E. SIGN LANDSCAPE�EASEAIENT
\�� �// ALL UNDERGROUND SEWERS ANO UTUiIES
4'SW � SHOWN ARE PLOTTED BY SCAIE FROIA
T. =879.06 �RECORD DRAWINGS' NRNISHED BY ENGINEER.
d j AS BUILT
\ \ / /
PRECEDENT HOMES
77d.EDISON WAY
� CARM�L, IN 46032
. (JU) 580-2982�
TYPICAL SWALE DETAIL
, `���UUU u n ui,ii,,,�.
NO7 TO
,�J��\S..�:..;`/Ci
� �` G • '��STER " '�
L 0 T 4 9 � 5°"� .��. F� ��
o ;'� �`��.. "=,
ASHBURY PARK � = N° �:. =
SECTION 2 : � 800q-o3� � ;
_ STATE OF : -
INST. /�200200099718 �-<y''�• iNp�qNP :�'Q�,;°
P.C. ��3, Slide #115 ��'�o,� �SURV�o�`°
ZONING: R1 - OPEN SPACE "��n,,,,,,,u��
0' MIN. SIDE YARD �� ��,�!�
10' BETWEEN STRUCTURES
20' MIN. REAR YARD
oa/is/oa ou
� "FIOLEY MOLEY SEZ"
"DON'T'DIC BLIN�"
�CALL TWO WORKING DAYS'BEFORE YOU DIG.
IT'S THE LAW
7-800-382-5544