Loading...
HomeMy WebLinkAboutSignage & Elevations1700 West Anaheim Street Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 Project: Account Manager: Designer: Scale: Design No.: Date: Page: Reg. No.: Revisions: This is an original unpublished drawing created by Superior Electrical Advertising. It is submitted for your approval. It is not to be shown to anyone outside of your organization, nor is it to be reproduced, copied or exhibited in any fashion. The changing of colors, sizes, materials or illumination method does not alter the design. Ownership of this design is held by Superior Electrical Advertising, Inc. Authorization to use this design in any fashion must be obtained in writing from Superior Electrical Advertising, Inc. Note: The Colors depicted here are a graphic representation. Actual colors may vary. See color specifications. Of: Address: www.superiorsigns.com design@superiorsigns.com c SEA 2005 Mike Gray M. Reiman 3.0 AS NOTED 05-03-5867-01 July 14, 2005 05 EDDIE BAUER Clay Terrace 14395 Clay Terrace Blvd. Carmel, IN 46032 05-06-6260-02 R1 (1.50) Jn 09.28.05 Fascia is 21 ½” tall, make letters 18” R2 (1.75) Jn 10.04.05 Back to 24” letters, move down, add oversized lexan backer CLAY TERRACE Carmel, Indiana 46032 SPACE #C28 SITE PLAN VICINITY MAP NORTH Eddie Bauer 01 NORTH 1700 West Anaheim Street Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 Project: Account Manager: Designer: Scale: Design No.: Date: Page: Reg. No.: Revisions: This is an original unpublished drawing created by Superior Electrical Advertising. It is submitted for your approval. It is not to be shown to anyone outside of your organization, nor is it to be reproduced, copied or exhibited in any fashion. The changing of colors, sizes, materials or illumination method does not alter the design. Ownership of this design is held by Superior Electrical Advertising, Inc. Authorization to use this design in any fashion must be obtained in writing from Superior Electrical Advertising, Inc. Note: The Colors depicted here are a graphic representation. Actual colors may vary. See color specifications. Of: Address: www.superiorsigns.com design@superiorsigns.com c SEA 2005 Mike Gray M. Reiman 3.0 AS NOTED 05-03-5867-01 July 14, 2005 05 EDDIE BAUER Clay Terrace 14395 Clay Terrace Blvd. Carmel, IN 46032 05-06-6260-02 R1 (1.50) Jn 09.28.05 Fascia is 21 ½” tall, make letters 18” R2 (1.75) Jn 10.04.05 Back to 24” letters, move down, add oversized lexan backer 02 Scale: 1/4” =1’-0” A STOREFRONT ELEVATION 43’-6 1/4” Lease Frontage NOTE: ACCESS REQUIRED FOR ELECTRICAL AND INSTALLATION 14’-1 ½” Center over doors 1700 West Anaheim Street Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 Project: Account Manager: Designer: Scale: Design No.: Date: Page: Reg. No.: Revisions: This is an original unpublished drawing created by Superior Electrical Advertising. It is submitted for your approval. It is not to be shown to anyone outside of your organization, nor is it to be reproduced, copied or exhibited in any fashion. The changing of colors, sizes, materials or illumination method does not alter the design. Ownership of this design is held by Superior Electrical Advertising, Inc. Authorization to use this design in any fashion must be obtained in writing from Superior Electrical Advertising, Inc. Note: The Colors depicted here are a graphic representation. Actual colors may vary. See color specifications. Of: Address: www.superiorsigns.com design@superiorsigns.com c SEA 2005 Mike Gray M. Reiman 3.0 AS NOTED 05-03-5867-01 July 14, 2005 05 EDDIE BAUER Clay Terrace 14395 Clay Terrace Blvd. Carmel, IN 46032 05-06-6260-02 R1 (1.50) Jn 09.28.05 Fascia is 21 ½” tall, make letters 18” R2 (1.75) Jn 10.04.05 Back to 24” letters, move down, add oversized lexan backer Scale: 1/4” =1’-0” B SIDE ELEVATION NOTE: ACCESS REQUIRED FOR ELECTRICAL AND INSTALLATION 03 126’-6” Lease Frontage EQ 2’-0” 1700 West Anaheim Street Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 Project: Account Manager: Designer: Scale: Design No.: Date: Page: Reg. No.: Revisions: This is an original unpublished drawing created by Superior Electrical Advertising. It is submitted for your approval. It is not to be shown to anyone outside of your organization, nor is it to be reproduced, copied or exhibited in any fashion. The changing of colors, sizes, materials or illumination method does not alter the design. Ownership of this design is held by Superior Electrical Advertising, Inc. Authorization to use this design in any fashion must be obtained in writing from Superior Electrical Advertising, Inc. Note: The Colors depicted here are a graphic representation. Actual colors may vary. See color specifications. Of: Address: www.superiorsigns.com design@superiorsigns.com c SEA 2005 Mike Gray M. Reiman 3.0 AS NOTED 05-03-5867-01 July 14, 2005 05 EDDIE BAUER Clay Terrace 14395 Clay Terrace Blvd. Carmel, IN 46032 05-06-6260-02 R1 (1.50) Jn 09.28.05 Fascia is 21 ½” tall, make letters 18” R2 (1.75) Jn 10.04.05 Back to 24” letters, move down, add oversized lexan backer 04 Scale: ½” =1’-0” A STOREFRONT SECTION Transformer located in parapet wall. G.C. To provide access panels. 2’-0” EQ 6” 1700 West Anaheim Street Long Beach, California 90813-1195 phone: 562.495.3808 facsimile: 562.435.1867 Project: Account Manager: Designer: Scale: Design No.: Date: Page: Reg. No.: Revisions: This is an original unpublished drawing created by Superior Electrical Advertising. It is submitted for your approval. It is not to be shown to anyone outside of your organization, nor is it to be reproduced, copied or exhibited in any fashion. The changing of colors, sizes, materials or illumination method does not alter the design. Ownership of this design is held by Superior Electrical Advertising, Inc. Authorization to use this design in any fashion must be obtained in writing from Superior Electrical Advertising, Inc. Note: The Colors depicted here are a graphic representation. Actual colors may vary. See color specifications. Of: Address: www.superiorsigns.com design@superiorsigns.com c SEA 2005 Mike Gray M. Reiman 3.0 AS NOTED 05-03-5867-01 July 14, 2005 05 EDDIE BAUER Clay Terrace 14395 Clay Terrace Blvd. Carmel, IN 46032 05-06-6260-02 R1 (1.50) Jn 09.28.05 Fascia is 21 ½” tall, make letters 18” R2 (1.75) Jn 10.04.05 Back to 24” letters, move down, add oversized lexan backer 05 LETTER SPECIFICATIONS MANUFACTURE AND INSTALL ONE SET DUAL ILLUMINATED CHANNEL LETTERS PIN MOUNTED 1 ½” AWAY FROM WALL SURFACE FACE TO BE WHITE ACRYLIC PLASTIC INVERTED VACUUM FORMED 2” RETAINERS TO BE ½” (FACE) x 1” (RETURNS) ALUMINUM PAINTED HEATHER GREY RETURNS TO BE 6” DEEP ALUMINUM PAINTED HEATHER GREY LETTER BACKS TO BE SANDBLASTED CLEAR LEXAN CUT 1” LARGER THAN LETTERS FOR HALO ILLUMINATION BEHIND SANDBLASTED LEXAN TO BE ALUMINUM BACKER SUPPORT CUT SAME SIZE AS LETTERS ILLUMINATION PROVIDED BY WHITE L.E.D. LIGHTING SYSTEM QUANTITY: TWO (2) UNITS REQUIRED SCALE: 1” = 1'-0" ALETTERS SIGN ELEVATION / DUAL ILLUMINATED CHANNEL WALL SURFACE METAL STUDS REMOTE TRANSFORMER WITH DISCONNECT SWITCH 1 SECTION DETAIL SCALE: 3” = 1’-0” 2” 4” 6” TOTAL DEPTH Refer to page 4 of 5 ½" ½" ALUMINUM RETURNS PAINTED HEATHER GRAY METALLIC ALUMINUM RETAINER FACE PAINTED HEATHER GRAY METALLIC ALUMINUM SUPPORT BACKER CUT SAME SIZE AS LETTERS INVERTED VACUUM FORMED WHITE PLEX FACE LETTER INTERIOR TO BE PAINTED WHITE FOR MAXIMUM LUMINOSITY LED LIGHT STRIPS THRU BOLT CONNECTION TO ANGLE IRON BEHIND WALL ELECTRICAL THRU ALLTHREAD NOTE: ACCESS R EQUIRED FOR ELECTRICA L AND INSTALLAT I ON FORM AS SHARP AS POSSIBLE CLEAR LEXAN ANGLE CLIPS RIVETED TO LEXAN BACK AND COUNTER SUNK SCREWED TO ALUMINUM RETURNS 2’-0” (CAPITAL E) 14’-1 ½” OVERALL SPREAD B Sign Voltage In the utilization of GFI transformers, and in accordance with NEC and UL guidelines, it is required that primary circuits to each sign must have: 1. Dedicated circuits with proper ground from main panel - and must be bonded. a. ANY equipment or lighting that is added/shared to the primary sign circuit will cause GFI transformers to trip "OFF". b. Neutral to ground should not exceed 3 volts to prevent GFI from tripping. Note to All Contractors Not adhering to these specifications will cause electrical outages resulting in costly service calls. 120 This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. NOTE: ACCESS REQUIRED FOR ELECTRICAL AND INSTALLATION WEEP HOLES OVERSIZED SANDBLASTED LEXAN BACKER ½” EQ B NOTE: SIGNAGE TO BE MOUNTED ½” PAST FURTHEST PART OF CORNICE. FIELD VERIFY ALL MEASUREMENTS AND CONDITIONS PRIOR TO ANY FABRICATION. EQ EQ 14’-1 ½” EQ EQ 2’-0” EQ