HomeMy WebLinkAbout04060124 Application � M , .
***IMPORTANT NOTE:.THE OFFICE;O.FBIJILDING AND CODE ENFORCEMENT
RECOGNIZES ANY ROOM/AREA DESIGNATED ON CONSTRUCTION PLANS AS A "BONUS
ROOM"T0 BE AN UNOCCUPIABLE, UNFINISHEDNSPACE. IF AN AREA SO LABELED'
IS TO BE A.FINISHED SPACE, .CONSTRUCTION PLANS.MUST BE LABELED ACCORDINGLY:
IF IT, lS'DEZERMINED:THA'T:4N;UNFINISHED�"BO/VUS RDOM"AREA IS TO
BECO'h1EA FINISHED:4REA .4fTER THEISSUAMCE'UFTHEPERMIT, THE PLANS
AND FERMIT RECORDS MUST BE UPDATED AT THE'OFFICE OF BUILDING & CODE
ENFORCEMENT.***
I CERTIFY THAT ALL OF THE ABOVE LISTED INFORMATION IS SHOWN GOMRLEfELY AND ACCURATELY ON THE
ATTAGHEDPLOT OR SITE PLAN AS SUBMITTED WITH A BUILDING PERMIT APPLiCATION TO THE CARMEL-CLAY
DEPARTMENT OF COMMUNITY SERVICES. I FURTHER CERTIFY THAT THE JOINING OF WATER SUPPLY PIPING
SHALL BE MADE WITH LEAD-FREE SOLDERS AND FLUXES. FAILURETO COMPLY WILL RESULT IN A REPLACEMENT
OF THE SYSTEM. PLUMBING CODE P-509-5.
Vnder the penalties of perjury (Indiana Code 35-44-2=3), I hereby uffirm under oath that nll of the
informotion I have provided in the table below is true and accurate to the best of my knowledge and
belief, und that I have not knowingly or intentionally provided or omitted any information that would tend
to hide, obscure or otherwise mislead the Dept. of Community 5ervices regarding the truth of the
motters addressed therein.
BASEMENT 1�` Floor 2"d Floor 3`d Floor Front Rear Total Sq. TOTAL
, (Finished and POICh POrCh or Ft. Of
Unfinished) Sunroom Garages �
� �7 l �0�3 � i�-�' �'�f� ��1 i��`�
NOTE: Additional plans and/or information may be required; if submitted plans are not of sufficient clarity or detail, to
indicate tFie'nature and extent ofthe work proposed and to determine compliance with all applicable codes and
ordinances.
In addition to the above, the Building Inspector will be provided with any information relative to commitments
made in the zoning process for the property involved. This would include any Plan Commission and/or BZA
activity.
APPLICANT'S�SIGNATUREc ��-�— /y � PHONE: � l� 3 Y� �!
ADDRESS: , 1' �O �//�r!y� l�S C_�i¢�n�+�:.C'_ �, Y��o4�} �
Dep�rtrnent of Coanmuni�,y Services
One Civic Square, Carmel, IN 46032 (317) 571-2444
s:Permits/forms/Perminfo Rev Jan'02 Rev.Jan.'02
; , _ ,
BUILDING PERMIT INFORMATION
CARMEL-CLAY TOWNSHIP
Department of Community Services
If the inforrrx�ation required (listed belowj is instafficient, it will I
extend the time it takes fo get 'an appro�ed building�perrriit.
CARMEL ZONING ORDINANCE Z-289, SECTION 29.4,2(3): The_Director, Department of,Community 5ervices (orstaf�
shall approve or denythe improvemenf location permit (building permit) within five.(5) working daysof the'receipt of the
written application form and accompanying materials. The improvement location permit (building permit) shall be issued
when the proposed structure; improvement or use and its location conform in all respects to this ordinance.
The following must be received bv the De�artment of Communitv Services before anv buildina or remodeling permit can
be reviewed or issued bystaff:
1. ONE completed Improvement Location Permit (Building Permit) application.
2. TWO (2) compleEe sets oF construction plans: Building elevations, foundation plan,%floor plan and typical
walf'section inust be shown. All cross-sections must be properly detailed'and labeled. At lease.one
cross-section must show R-values of building materials to ensure compliance witfi'the'Indiana Ene�gy
Codes. If minimum R-values are not met on cross-section an Energy Code Compliance'WorksHeef-'must
be completed. If manufactured trusses are used, a diagram must tie included with building plans for all
trusses being used. Truss diagrams must 6e stamped with the seal of the registered architect or
engineer who is'responsible for that design.. Only Indiana registrations will be recognized. If a
commercial construction,plans must be stamped aporoved by the Indiana State Department of Fire
Prevention & Buildina Safetv. Indicatefotal height of 6uilding on plans.
3. ONE copy of sewer permit(from City of Carmel Engineering Dept., Hamilton Western Utilities or Clay
Regional Sewer District whichever applies);;ar septic permit (Hamilton County Health'Department).
4. ONE (1) copy of plot plan from approved subdivision construction plans.
5. TWO (2) copies of a site plan or plot plan showing the following REOUIRED information (can be obtained
from the landowner or developer):
--Name and address of designerof plan with date
--Name and address of owner
--Lot number and'subdivision,or applicable general description
--Lot drawn to scale -- all dimensions
--Scale and north a�row
--Lot/Property lines .
--Minimum front 6uilding setback line per approved development plan (include all front yard)
--All roads, alleys, rights-of-way; etc.
--All otfier utilities and drainage rights-of-way and easements
--Any applica6le flood plain area (Elevation Certificate if necessary)
--Building pad elevation and lot corner elevations
--All'accessory buildings ---ezisting or proposed
--All sidewalks and driveways
--Sewer and water lines, septic system (tanks &filed system) and well location
--Drainage flow arrows , �
--All drainage swales and subsurface facilities (retention/detention areas, etc:)
--Sump'pump (sump pump pits) showing discharge locations
--Geothermal heat pump discharge locations
If land is not within a platEed subdivision, a legal description is needed.
ALL CONSTRUCTION IS SUBJECr TO FIELD INSPECTION