HomeMy WebLinkAbout14050191 Sq. Ft. FLIRTHER NOTES / NOTICES:.
� CARMEL ZONING ORDINANCE Z-289;SECTION.29�:04A2(3):� "The Director shall-approve or deny the Improvement Location Permit
within five (5) working days of the receipt oFthe written application formand�accompanying materials. The Improvement Location
Permit shall be issued when'.the-proposed'structure, improvement, or use and itr location wnform in all respects to this ordinance."
: IN ADDITION TO THE ABOVE-LISTED;SUBMITTAL REQUIREMENTS,THE BUILDING INSPECiOR SHALL BE PROVIDED INFORMATION
RELATIVE TO COMMITMENTS��MADE IN THE ZONING PROCESS FOR THE�PROPERTY�INVOLVED. THIS INCLUDES ANY PLAN
COMMISION, BOARD Of ZONING APPEALS;AND/OR DEPT. OF COMMUNITY SERVICES ADMINISTRATIVE APPROVALS REQUIRED.
� ADDTTIONAL INFORMATION MAY BE REQUESTED BY,AND SHALL BE PROVIDED TO THE BUILDING INSPECTOR, IF TFiE
SUBMIiTED PlqNS ARE NOT OF.SUFFICIENT IN CLARITY OR DETAIL,TO INDICATE THE NATURE AND EXTENT OF THE WORK
PROPOSED AND TO DEfERMINE COMPLIANCE'WITH'ALL APPLICABLE CODES AND ORDINANCES. PLEASE NOTE: IF ADDifIONAL
ITEMS FOR REVIEW ARE.REQUESTED, REVIEW TIME MAY BE EXTENDED.
� ALL CONSTRUCTION IS SUBJECT TO FIELD INSPECTION,AND SHOULD NOT BEGIN PRIOR TO THE ISSUANCE OF THE
BUILDING PERMIT. ONCE THE PERMIT IS ISSUED,.WORK SHOULD NOT BE�POURED, INSULATED/COVERED,AND/OR OCCUPIED
PRIOR TO THE APPROPRIATE INSPECTION. Beginning prior to obtaining�a building permit and/or proceeding with construction
beyondThe stage of a required�inspection�without approval mnstitutes Late Fee penalties, pe�Z-289 of the Carmel/Clay Zoning
Ordinance; 29.06.07, and�29.06.06.
BUILDING & CODESERVICES; CITY OFCARMEL. One Civic Square; Carrnel, IN 46032. Ph. (31 7) 571-2444.
Provide Sq. Ft. for entire structure for new single family home, if remodeling or adding an addition / accessory structure
provide Sq. Ft. of work area:
BASEMENT 1�` Floor 2nd Floor 3rd Front Rear Total Sq. TOTAL
(Finished and Floor Porch Porch or Ft. of
Unfinished) Sunroom Garages
�?A 912(� (�;�- � Q(6� -� S?.�� 3�'�� �'
Per the Adopted Indiana Energy Code that will be in effect for all New Buildings, Additions, Accessory Structures, and
Remodels. There are three methods of compliance to choose from. It is REQUIRED to indicate which compliance
that will be used at time of submittal. Please select from the following:
(Handout for Compliance of Energy Code can be picked up in our office or found at: http://www.carmel.in.qov/ )
�Prescriptive(irio`st;restndive) '�,'��� �� �
��i��'�,�,�''�"� '+4-
Tofal UA(allows building
envelopetrade-offs)
, Performance(m��o'�st���flexible) '�� "x:
� 9' > ' f�, �
„ ��
I, the undersigned, certifythat all of the above listed information is shown completely and accurately on the attached plot or site
plan(s), construction plans, and any other submitted documentation; submitted witRthe 6uilding permit applicationYo the City of
Carmel/ Clay Township Department of Community 5ervices. I further certify that the joining of water supply piping shall be made with
lead-free solders d Fluxes. Failure to comply will result in a replacement of the system. (Plumbinq Code P-509-5) Under the
penalties of P ury ndiana Code 35-44-2-1), I also hereby affrm, under oath, that all of the information I have provided in the table
below,is tru nd acc rat , to e 6esCof my knowledge and belief, and that I have not knowingly or intentionally provided or omitted
any inform ion that o d tentl- o fiide, obscure, or otherwise mislead the Dept. of Communiry Services regarding the truth of the
matters ad r se 't er in.
5`� 1,�
APPLICANT'S SIGNATURE � DATE
���� No right of way permit needed.
Print
/j oF Cqq
rernrnrx i��!
� ' I SINGLE FAMILY/ TOWN HOME / TWO-FAMILY
PERMITTING PROCEDURES
�xo_Aa9� New Structures, Additions, Remodels, Garages, & Accessory Structures
SUBMITTAL REOUIREMENTS:
1. COMPLETED RESIDENTIAL IMPROVEMENT LOCATION PERMIT APPLICATION, (ILP) which also
includes the reverse side (or 2nd page) ofthis procedure sheet.
2. CONSTRUCTION PLANS: At least one set of the plans should be on paper no larger than 11 inches by 17
inches. If this is not possiblean electronic PDF copy of plans should be emailed to nmishlerCa�carmel.in:gov , or a disc
containing the electronic PDF copies shall be submitted, in addition to the paper copies.
NEW MAIN STRUCTURES J ADDITIONS / ACCESSORYSTRUCTURES, TWO SEfS OFPLANS FOR SINGLE FAMILY,
TWO-FAMILY, AND TOWN HOMES, MUST BE SUBMITT"ED.* THESE SHOULD INCLUDE:
-Building Elevations -Foundation Plan -Floor Plans -Typical Wall Section
-If Manufactured Trusses are used, truss diagrams must be included with the building plans. Truss diagrams must.be
STAMPED with the-seal of fhe registered architect or enginee�who is responsible for that design. ONLY Indiana
registrations will be recognized.
-A SITE (OR PLOT) PLAN SHOWING THE FOLLOWING REQUIRED INFORMATION:
a. Name and address of designer of p1an, with date, Name and address of property'owner
b. Lot num6er and subdivision name, or applicable general description
c. Lot drawn to scale—all dimensions: Including Lot/Property lines
d. Nlinimum front building setback line, per approved development plan (include all front yard)
e. All roads, alleys, sidewalks, driveways, rights-of-way, etc...
f. Any applicable flood plain area (Certificate of Elevation, if necessary). �
g. Building pad elevation and lot corner elevatioris � � � . ,_ � . .'
n. All accessory buildings / structures - existing or proposed
i. Sewer and water lines, septic system, (tanks &filed system) and/or well locations
j. All drainage swales-and subsurface facilities, drainage flow arrows (retention / detention areas, etc...)
k. Sump pump -- Show sump pump pit(s) and discharge line locations
I. Geothermal heat pump discharge locations
*NOTE: If land is not within a platted subdivision, a legal description is required.
-ONE (1) COPY OF THE SUBDIVISION CONSTRUCTION/DEVELOPMENT PLAN IS REQUIRED—FOR NEW DWELLING
UNIT STRUCTURES ONLY. Sometimes referred to as an "as-built,"this plan should show the,lot,the surrounding lots,
the building pad or building pad elevation, and the ground Eopography lines. Plans forthe entire subdivision are NOT
required.
-If large equipment is being used, an approved Right of Way Permit from City of Carmel Engineering Office is required.
Please contadthe Engineering Office at: (317)571-2441. '
*NOTE: For all Town Home submittals hvo full sets of construction documents need submitted per Building covering all
options of each unit within the building, along with the State Design Release.
REMODELS. TWO (2) SETS OF PLANS MUST BE SUBMITTED AND SHOULD INGLUDE:
-Floor Plans -Typical Wall Sedion
3. SEWER AND WATER PERMITS FOR NEW STRUCTURES OR ADDITIONS OVER 1,000 SQ. FT. Please
determine which utility company provides services to your construction site, and provide a copy of the utility permit. '
a. Carmel Utilities: (317) 571-2443. A sewer and/orwater permit should be purchased aY;the o�ce of Building &Code "
Services, prior to o�atthetime you are submitting yourbuilding permit application. , ,
b. Clav Townshio Reaional Waste District; (31Z) 844-9200.
c. Hamilton Coun[v Health Deot. (for wells and/or septic permits); (317) 776-8500