Loading...
HomeMy WebLinkAbout81-01 C105 Site Lighting Plan� 1 l i 6 m N m M N m C ra m rn rn r m m -_..—..,- . .............................. - - ............................... 1 CALCULATION STATISTICS AREA OF CALCULATION NUMBER OF POINTS AVERAGE MAXIMUM MINIMUM AVG /MIN MAX /MIN GRID 659 1.76 9.87 .01 176 987 CPnCNS EC A 23 1 3H 1000Mi 277 BRP LF IC A ArmMxrt3 14 1 Z 14: LUMINAIRE DATA IS OBTAINED ACCORDING TO IES PROCEDURES UNDER CONTROLLED LABORATORY CONDITIONS. FIELD RESULTS MAY DIFFER FROM COMPUTER PREDICTIONS BECAUSE OF MANY UNCONTROLLABLE FACTORS AND ADVERSE TEST CONDITIONS SUCH AS, LINE VOLTAGE VARIATIONS, LAMP PERFORMANCE, PRODUCT MANUFACTURING TOLERANCES AND JOBSITE CONDITIONS. T.B.M. 2 5/8" REBAR WITH RED CAP AT DELAWARE COMMONS SUBDIVISION CONTROL POINT / 1005 ELEV.- 779.91 T.B.M. 3 BRONZE DISK ON TOP OF SOUTHWEST CORNER BRIDGE WALL OVER MITCHENER DITCH ON HAZEL DELL RD. STAMPED "HAMILTON COUNTY GEODETIC CONTROL" 2.5 FEET ABOVE SIDEWALK. ELEV.- 769.39 NOTE: T.B.M. 3 ELEVATION WAS BASED FROM ADJOINING SUBDIVISION AND DOES NOT REFLECT H.C. PUBLISHED DATA. HOLEY MOLEY SAYS "DON'T DIG BLIND' 'mS THE LAW' CALL 2 WMNG DAYS BEFORE YOU DIG 1- 800 - 382 -5544 CALL TOLL FREE PER N MA STATE LAW IS -69 -1991. IT IS AGAINST THE LAW TO EXCAVATE NTHWT NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) N)RKNG DAYS BEFORE COMIIIENCNG WOK i ICI ASSUMED NORTH SCALE: 1"=30' g MAW ECOLUM E ECA/ ECW The aclurne ECAWNis a rectilinear arrn -Fro rated area lurrinalm The precision segrnented optical systems provide required light levels, even I lurrinadon, wide pole spaci ngs ad glare control. The hiotsirg Is dia4=4 this door frarne Is extruded alu ninum, The Eodume lurrineire Is completely sealed and gasketed, preventing intrusion front moisture, Insects and act to. nerts. P H O T O M E T R I C TYPS 2H - Horizontal Lang a Type 3 3H - Honzontel Lang 3V - Varli al Lamp D I S T R I B U T I O N S 0 QH�t�Onsrnp ov - vertical Lamp a Forward Throw FH - Hmimnlei Lamp FV - Verbal Lang O R D E R I N G ECA14 ECA18 ECA23 A 14' 18 "s PREFIX Ml7UNfN G 512E OOhFK7NATICN DISTRIBurricw W4TrAGE VOLTAGE FINISH CPnCNS EC A 23 1 3H 1000Mi 277 BRP LF IC A ArmMxrt3 14 1 Z 14: 120 BRP Bma3paint F W Vvall Mart 7 18 211 M HPS 208 EI P 8ladc part FF n 2 0-•-0 3H 100HPS 240 WP Wttepeint LF U W FH 15OFFS 277 NP NakM LAY 3 010 jX 2i 100Mi 347 Alminm PCR 3H Q✓ 2H 3V 1751Vi 480 paint PGr Q FH 3H CN im y SC S�edal PCB 4 ❑- Qi FH FV 250HPS 75DFFS Color pant Hsi Ct]-C7 CH 400HPS 1000141S ( +(Y) M Wes 25OW 750M-1 AP7 QV•:*C' 400Mi 10ODMi AT 'OasimNoia AdcidadomaeMlde1997(ara Wcrytaamledlily) PIF TYPE PREFIX MOUNTING SIZE CONFIGURATION DISTRIBUTION WATTAGE VOLTAGE FINISH OPTIONS EC EC EC 710-3r- • • . I TA*5ad3wrhrediadrediro ciepmer.9ho be "mled ariy in Mi,cd= regrierg amore madm mb minimrntr1brrilyrt4w(5b1vbne* RKkaid Iu twiredidacy %111 resAinbaarawngataoloarde Ieela 2 Qreeu tledcy f ramial Wy. 3 Pnnrrn ifton ro" poles isrissigiedlonwibpdes rnai *g3.SQLh orIxW. 4 Rrlcoumd not aelletbewdr4ti0V. • 2ruitso*.. 818' ad 27uisonly. 7 I rand 18'uAsoriy. F Sgle Fuse in Head (12N,,27Nor347V) FF DoLLie Fuse In Head (208V, "or48M0 LA Direct topdennurlhrlgpessarm)" walable w ✓sYgeardtvlinlrrinairesatIV LF In-Pole Wine Fusing OQ Inolu&e Int ine Fires) PCR L oddm Type t aocontrd Receptacle PCT Loddrg Type Roocortrd Reoeptade WR do=W 4 PCs el,a«h Photoco trd 4 HS Irierrral House side Shield (Supplied standard to R" W Kid ArmFiter AP Act)tstable l0zrdde- Ftle Mount AT ACl stede Knrdde -Tenon Mm" PiF PbleTOpFdter 100"1-00pTHOMAS* 2661 Alvarado Street, San Leandro, CA 94577 800/227.0758 (CA) 5101357.6900 FAX 510/357.3088 F MC0 _ httpJ /www.thomasilghUng.com LtG11 r.][NG> l SPECIFICATIONS Ge ERAL DESCRIPTiCR Each EMCO Eooluma is a sharp cutoff luminaire for high Intensity discharge lamps. Internal components are totally enclosed, rain -tight, dust - tight, and corrosion resistant. No venting of the optical system or electrical corrponerts is required or permitted. Larrping requires no lifting or hinging of the lu ninaire hossirG disttrbirlg wiring ar sposirg urinsulated live p— -1 HOLISINQ The housing wapper Is or a Oeoe deldmed alurrirrrri Wt h an Integral reinforcing spine and no waded corners. Silicone seals provide a vmathertight seal at all points of material transition. LENS A mitered, extruded ariaized alu mn m door frame retains the optically clear, heat avid impact msLstent tempered flat glass in a sealed manner using hollow section, high eorrpliance, memory retentive extruded silicone rubber. A non- yelkWng drop acrylic lens is provided stardad on 14" and 16' vertical lamp and a sag glass lens is provided on 2T vertical larrp lu r imaires. A sire flush 114 turn captive fastener permits easy access to the lurrinsins. OPTICAL SYSTEMS: The seginerted reflector system oasists of two levels of highly spwA,w alurrirtrn facets precisely aligned to ac is a specified photometric distributions. The entire optical system is field rotatable In 90" Increments, The position -ono ted mogul base socket is glazed porcelain with a Hold plated screw shell. A lamp stabilizer is standard on 3H and Gin 400W MH urlts. EPA'S AND WEIGHTS Ecolume EPA (Effective Projected Area) Ft2 Single Fixture Single Arm Twin 18" Quad Weight 14" units 1.1 2.2 2.7 30 Ibs 18" units 1.9 3.8 4.8 50 Ibs 23" units 3.6 7.3 8.8 90 Ibs 4 111111 RA [sill ECW14 7,fvI8 A 14" s B 7" 1 r 1 BdCO 2661 Alvarado SI. Sin Leandro, CA 94577 8001227 -0756 5101357 -09W (California) FAX 510/357 -3086 http://WWW.thomafthling.com In Canada: 10L 640 Cur BDIvIn Blvd. BDlrbriand . Quebec, Canada J7G 2A7 7&1:514/433.3216 FAX: 514/4338441 ELECTRICAL: Each high pow factor ballast is the separate corponent type capable d p Wdlrg reliable harp starting to 20"F. The glad tap (120V/ZOWrA W/27M ballast is mounted on a unitized tray and prsWmd with gLicc electrical disconnects to the supply wire and the socket assembly. Entire ballast assembly is seotued Wttin the lurrineire, atrowe the reflector system h5gh Pressure Sodium ballasts operate lamps within ANSI trapezoidal units. Metal Halide ballasts are rmecium regulation auto4ansibrmer providi ng f10% power reguation with i10%va i ado n from rated Input voltage. Component -to- component wiring within the lurrinaire W11 carry no more than 80% of rated o rrert and is listed by UL for use at 600 VAC at 150° or higher. Plug dso3T*K s are listed by UL for use at 600 VAQ 15A or higher: RNISH: Each lurrinaire receives a fade and abrasion resistant, deft"caly applied, t wmlllyared polyester pQAder finish after fabrication. LABELS: All IALres bear tL VUt Location and IBEW labels lharras UghBrg reserves to rlgt to charge rrsierials or modcy the deslgr or Its product raw ftd no88callm, as part d the cor pu ys contfrOM product irrprvvernert Pw- 4- • PROJECT NO.: ECA14 ECA18 ECA23 A 14' 18 "s 23" sq B 7" 10" 14.5" C Ann Length 6" _ Ir 712" D Arm Height 5" 5" 8" E Drop Lens 2" 4" 6.5' THOMAS' EMCO LLCif 17ING 79215-501797 0 J Z �a a 0 W W W pN tai 5 W M ``11 1111111 y' ``GORT CRps�•'�, NO Fo••.. 920350 STATE OF DATE: to Ji,lIt'•I THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF THE SCHNEIDER CORPORATION, AND ARE NOT TO BE USED OR REPRODUCED. IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF THE SCHNEIDER CORPORATION. ® COPYRIGHTED BY THE SCHNEIDER CORP. (2001 Schneider THE SCHNEIDER CORPORATION Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216 -1037 Telephone: 317.826.7100 Fax: 317.826.7200 www.schneidercorp.com Architecture Civil Engineering Environmental Engineering Geotechnical Services GIS *LIS Home Builder Services Interior Design Land Surveying Landscape Architecture Transportation Engineering DATE: PROJECT NO.: 06115/01 904.005 DRAWN BY: W PRC SHEET TITLE: SITE LIGHTING PLAN DRAWING FILES: R: \904 \005 \DWGS \C105 XREF. 005BS XRER R: \904 \OD5\DWGS \60BSOV XRER R: \904 \0D5 \DWGS \904005TP N� W SHEET NO.: (CIDS TO V Z Z FAZ W C) U W a DATE: PROJECT NO.: 06115/01 904.005 DRAWN BY: CHECKED BY: PRC SHEET TITLE: SITE LIGHTING PLAN DRAWING FILES: R: \904 \005 \DWGS \C105 XREF. 005BS XRER R: \904 \OD5\DWGS \60BSOV XRER R: \904 \0D5 \DWGS \904005TP XRER R: \904 \005 \DWGS \005 -UTE SHEET NO.: (CIDS