HomeMy WebLinkAboutC802 SANITARY SEWER DETAILS1/2 TRENCH NEENAH R-1642 W/SELF SEALING LID (OR EQUAL) DEPTH MIN. FINISH GRADE STAMPED *SANITARY SEWER" (GRANULAR MATERIAL TO A NOTE ...... .... BE USED UNDER ALL A A AA PRECAST CONC. PAVED AREAS RINGS JOINT CONFORMS TO ASTM C-443 TAPERED CONE INFI—SHIELD 'UNIEIAND"— SECTION 4' /% 4t OR APPROVED EQUAL SEAL 10 SOIL LLI // /\� 'W PER IMPPIPIPATIMIQ I PLACEMENT ° / /\� "' 0 00 z Ld cn 0 . o5 / lw PRECAST CONCF Z- W SECTIONS BEDDING Z F= z Cy 0- w W W F in CIL I- W NO. 8 CRUSHED STONE W< Lin *t (16" MAX.) in -i Ld F- < POP v. 00 SPRING LINE OF PIPE 12" MIN. —"-) 1. D. BUTYL RUBBER COATING AS PER SPECIFICATION >MANHOLE STEPS O.D. OF PIPE FOUNDATION 6 MIN. (REQUIRED IN UNSTABLE SOIL) 12 (MIN.) (MIN.) TRENCH & PIPE EMBEDMENT DETAIL 5 \, 12 � NORMAL GRADE - 1/4" PER FOOT MIN.-1/8- PER FOOT CONNECT TO EXISTING SERVICE PLUG FOR FUTURE CONNECTION. ISOMETRIC PLAN PLUG SHALL BE ABLE TO PASS AIR PRESSURE TEST REQUIRED FOR PRESSURE SEWER MAIN. 30'-\ USE 6" SEWER PIPE MIN UNLESS OTHERWISE E :1 45* MAX. -V J SEWER SPECIFIED MAIN APPROX. 90' , LONG RADIUS SECTION A-A DIAMETER AS SPECIFIED /X- ON PLAN OR SCHEDULE PLAN VIEW CONNECTION TO MAIN SEWER I —COVER & SEAL BELL HOLES SHALL BE PROVIDED AND THE TRENCH PREPARED SO THAT THE BOTTOM IS PROPERLY SUPPORTED THROUGHOUT ITS LENGTH. APPROX 90' USE 6" SEWER PIPE UNLESS zz­ OTHERWISE SPECIFIED LONG RADIUS CURVE 4' FILL WITH —CONCRETE .. . ..... ....... ..... 14 .... ... ......... ........... ....... .. . PLAN PRECAST BASE ....... .... 1. 1. 1 .... .............. ........... ... .............. ................. . �#4 ®12" EA. WAY .................... .............. 00 A V .... O g �0 *0 .0 0 '0 °0. ° .O. 0 .0. , °0. 0 .0. 0 °0. 0 6" MIN. NO. 8 CRUSHED STONE U-- REQUIRED UNDER MANHOLE BASE IFOR LEVELING AND SUPPORT 4'-0" MIN. MANHOLE BASE FOR PRECAST SECTION A-A SANITARY MANHOLE DETAIL_ CARMEL f h IN 1-1 /-DIAMETER AS — — — — - - - - -J --- - - - - -- -F1 - - - - - - SPECIFIED I I I ON PLANS I - - - - - - - - - - - - - - --- - - - - - - - - - - - - - - - - 0 SEAL MUST BE ABLE TO PASS AIR PRESSURE TESTS REQUIRED FOR SEWER MAIN WYE & LATERAL CAPPING DETAIL C) CD OU ro C) (16 Lr-) 6 0) C- C1 CM CU C) 00 C-3 U) ca) X 0i C) CD co CU PLACE 1/2- DIA EXTRUDABLE—'- PREFORMED GASKET MATERIAL IN EACH KEYWAY (SEE DETAIL). PLAN VIEW PRECAST CONCRETE ADJUSTING RING OR ..... ..... FLANGE OF CASTING .. . 4 " -12" .......... ........... .......... NOMINAL 2 6ABUTYL RUBBER 24 I.D. B ASE EXTV UBLE PREFORMED GASKET MATERIAL (TYP) SEE DPW SPECS. GASKET DETAIL SECTION A—A ADJUSTING RING DETAIL 2500 psi CONCRETE BOTTOM OF TRENCH (FIGURE 5-4B) \W Perspective View-earth cut away To be used when clear distance between pipes is 18" or less, or where noted on the drawings. CONCRETE CRADLE TYPICAL UTILITY CROSSING O Uj ............. N o. 9800085 -10 t STATE OF %. NDIANP Z .... ...... S, 70 * .... * NA DATE: THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF THE SCHNEIDER CORPORATION, AND ARE NOT TO BE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF THE SCHNEIDER CORPORATION. (9) COPYRIGHTED BY THE SCHNEIDER CORP.(2001)1 f41110 Schneider THE SCHNEIDER CORPORATION 12821 E. New Market Street Suite 100 Carmel, IN 46032 Telephone: 317.569.8112 Fax: 317.826.6410 www.schneidercorp.com Architecture Civil Engineering Environmental Engineering Geotechnical Services GIS * LIS Home Builder Services Interior Design Land Surveying Landscape Architecture Transportation Engineering DATE: PROJECT NO.- 4/19/01 1238.V02 DRAWN BY: CHECKED BY: DCC CD SANITARY SEWER DETAILS C\2 N: \1238 \VO02 \DWGS \C802.DWG SHEET NO.: (C 2 C) Cid z W DATE: PROJECT NO.- 4/19/01 1238.V02 DRAWN BY: CHECKED BY: DCC SHEET TITLE: SANITARY SEWER DETAILS DRAWING FILES: N: \1238 \VO02 \DWGS \C802.DWG SHEET NO.: (C 2 I 1 1� I I