HomeMy WebLinkAboutSite Development Plan pg2IRON HORSE LANE 10 +124 881.9f Str. No. Type Tc /Rim Inverts Dir. 800 MANHOLE 887.75 872.50 (SW) 801 CONC. END SECTION 873.00 (NE) 802 Q CONC. END SECTION 873.00 (NW) 803 YARD INLET 878.00 874.97 (W)(SE)(S) 804 YARD INLET 878.00 875.42 (E) 805 CURB INLET 881.62 875.61 (N)(S) 806 O < p CURB INLET 881.62 875.70 (N) 807 CONC. END SECTION 873.00 (SE) 808 YARD INLET 878.70 874.24, 873.24 (NW)(SW)(S) 809 CURB INLET 880.51 674.05 (NE)(SW) 810 CURB INLET 880.35 874.34 (NE)(SW) 811 YARD INLET 877.00 874.95 (NE) 812 CONC. END SECTION 875.17 (N) 813 YARD INLET 874.70 869.51 (N) 814 CONC. END SECTION 872.50 (S) 815 CONC. END SECTION O 872.50 (SE) 816 MANHOLE 879.50 872.63 (NE)(NW) 817 CURB INLET 879.50 873.37 (NE)(SW) 818 CURB INLET 879.62 873.73 (SW) 819 CONC. END SECTION 872.50 (NW) 819A MANHOLE 882.40 872.64 (NW)(SE) 820 CURB INLET 881.78 872.76 (SE)(NE) 821 LEGEND CURB INLET 881.78 872.86 (SW) 822 CURB INLET 881.71 873.16 (NW)(SE) 823 CURB INLET 881.88 873.25 (SE) 824 CONC. END SECTION 872.50 (SW) 825 MANHOLE 878.50 872.88 (W)(NE) 826 MANHOLE 880.00 874.19 (E)(SW)(N) 827 CURB INLET 881.07 874.84 (NW)(S) 828 PROPOSED CONTOUR CURB INLET 881.07 874.93 (NW)(SE) 829 YARD INLET 881.50 875.49 (NE)(SE) 830 ES zz YARD INLET 880.60 876.18 (SW) 831 I CURB INLET 879.42 874.24 (NE)(W) 832 > CURB INLET 879.42 874.33 (SW)(W)(E) 833 CURB INLET 881.04 875.39 (SE)(NE) 834 CURB INLET 881.21 875.54 (SE)(NW) 834A HOME BUILDER) CURB INLET 880.04 875.85 (SE)(NW) 835 (UNLESS OTHERWISE NOTED) CURB INLET 879.87 876.00 (NW) 836 YARD INLET 880.50 874.82 (E) r00 LLl r 0) O O Z NOTE: THE PROPOSED STORM SEWER SYSTEM SHOULD INCORPORATE ANY TEMPORARY OR PERMANENTLY EXISTING FIELD DRAIN TILES DISCOVERED DURING CONSTRUCTION. 000 -� V MUAS.E.&L.M.A.E. 75r� 3 N.P• 35 O E' NOTE: DECORATIVE SIGNS, SPRINKLER SYSTEMS, TREES, LANDSCAPING MOUNDS, LIGHT POLES OR OTHER SUCH AMENITIES WITHIN THE R.O.W. ARE TO BE APPROVED PRIOR TO INSTALLATION. m 1 W z 0 5 w o: EXISTING GRADE T.O.B.= 878.00 PROPOSED GRADE T.O.B.= 880.00 4 4 �1 N.P.= 873.00 1 1' -0" ... ..• 10' -0" 10' -0" 3 3 SAFETY 1 1 LEDGE BOTTOM= 865.00 SECTION "A" - "A" N.T.S. EXISTING GRADE T.O.B.= 878.00 PROPOSED GRADE T.O.B.= 878.00 4, 4 �1 N.P.= 872.50 1 10' -0" 10' -0" 3 3 SAFETY 1 1 F LEDGE 7PROP SECTION "B" - "B" N.T.S. "HOLEY MOLEY" SAYS: 1-800-382-5544 CALL TOLL FREE - 800 -428 -5200 FOR CALLS OUTSIDE OF INDIANA CAUTION LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, & marks made upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. Z Q nj L.1. Z CW nL O Lj Lj 0 Lj f- M W O V LL rO V J 0 Z SHEET NO. 5 OF 28 SHEETS roe "0'33697 Z Q 0 Z J W U Y Q Q V m 0 `� O < p "�SrE"' SCALE: 1 "= 50' ,.- �'��.o ��No Z- =ate 19358 ? -o ` STATE OF �Q / O O LEGEND Li. EXISTING CONTOUR EXISTING SANITARY SEWER Ld v EXISTING STORM SEWER ® PROPOSED GRADE a e+e PROPOSED CONTOUR 04 `� rn z Q O LO ES zz PROPOSED SANITARY SEWER >- I - --�- PROPOSED STORM SEWER > rn It 00 rY <000 PROPOSED SWALE r PROPOSED 4' SIDEWALK (BY HOME BUILDER) M (UNLESS OTHERWISE NOTED) x Z < F_ J 35 I LOT NUMBER I N. P. I NO PAD TO BE CONSTRUCTED. C CD I - J ty W � n W PROPOSED 4" LATERAL Z of o - - PROPOSED 6" UNDERDRAINS z aI Ld C� n Z � LO J Ln 00 0 a Z � z LC 0 v z EXISTING GRADE T.O.B.= 878.00 PROPOSED GRADE T.O.B.= 880.00 4 4 �1 N.P.= 873.00 1 1' -0" ... ..• 10' -0" 10' -0" 3 3 SAFETY 1 1 LEDGE BOTTOM= 865.00 SECTION "A" - "A" N.T.S. EXISTING GRADE T.O.B.= 878.00 PROPOSED GRADE T.O.B.= 878.00 4, 4 �1 N.P.= 872.50 1 10' -0" 10' -0" 3 3 SAFETY 1 1 F LEDGE 7PROP SECTION "B" - "B" N.T.S. "HOLEY MOLEY" SAYS: 1-800-382-5544 CALL TOLL FREE - 800 -428 -5200 FOR CALLS OUTSIDE OF INDIANA CAUTION LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, & marks made upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. Z Q nj L.1. Z CW nL O Lj Lj 0 Lj f- M W O V LL rO V J 0 Z SHEET NO. 5 OF 28 SHEETS roe "0'33697 Z Q 0 Z J W U