HomeMy WebLinkAbout17 a400 ceiling plan.pdfSUSPENDED CEIUNG NOTES: 1. HANGER WIRES MUST BE N0. 12ga. MIN. SOFf— ANNEALED, MILD STEEL WIRE. WIRE SHALL BE WRAPPED TIGHTLY AT RUNNERS AND SUPPORfS AND TIED WITH A MIN. OF 3 TURNS. 2. CLIPS SHALL HOLD RUNNERS TIGHTLY TOGEfHER. SPLICE CLIPS SHALL BE CAPABLE OF RESISTING ATLEAST SOlbs. IN TENSION OR COMPRESSION. 3. FOR MPNUFACTURED SYSTEMS, SUBMIT SUBSTAN— TIATION IN ACCORDANCE WRH U.B.C. STPNDARD SECfION 47.18811. 4. RUNNERS SHALL BE CAPABLE OF SUPPORTING CEILING SYSTEM WIiH DEFLECTIONS LESS 7FiAN 0.133 INCH. 5. LOCAL KINKS AND BENDS SHALL NOT BE MPDE IN HANGER WIRES FOR LEVELING 6. FOR SUPPLY AIR DIFFUSERS AND RETURN AIR GRILLE'S PROVIDE ADDITIONAL TEE'S AND WIRE HANGERS AS REQUIRED 7. COORDINATE CLEARMlCES WRH MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS. 8. CEILING HEIGHiS ARE FROM FlNISH ROOR 9. COORDINATE ALL LOCATIONS OF CEILING ACCESS PANELS WRH MECHANICAL DRAWINGS. VERTICAL HANGER WIRES 04'-0' O.C. MAX EA. WAY AND 8" MAX FROM WALLS HAN HEA � � �� i` J \ DO NOT BEND WIRE AROUND IMERFERING EOUIPMEM. PROVIDE TWO 1 1/2" CHANNEL TRAPEZE. REINFORCED SUSPENDED 2 CEII.ING BRACING DETAIL � Q � Q, �„���.,��� ��,,,.,� O O O O / 8• � W� CENN< CONNECTION DETPIL TILE MAIN OR CRO' RUNNER FACE OF WPLL $ASPBND� C�.IldG .,,..JER WITHIN 2" OF CROSS RUNNER PROVIDE WIRE TIES W/4 TURNS MIN. IN 1 1/2°(TYP OCLG. RUNNERS & ATfACH TO PURLINS & EAVE STRUIS). � SUSPENDED CEIUNG DETAILS: �12 048' O.C. MAX EA WAY ALL MAIN RUNNERS ANCHOR TO STUD AND — 3 TIGHT ALL CORNERS / NRNS � M �/a• HANGER WPLL ANGLE WIRE MOLDING MAIN iRUNNER I I I 3/4 (1) POP RNET OEA. RUNNER (2 ADJACEM MAIN RUNNER SIDES ONLY) T BAR MAiN/Qt�S �ffi�ffiffit TO WALL OONNBCiZON �11 AWG WIR6 OCORNERS OF Fl7RURE5 IYP. MAIN RUNNERS SECONDARY RUNNERS MAIN RUNNER � SECONDPRY RUNNER BEND DOWN AITACH TABS (90 TABS DEGREE BEND) RUHIV�t ATTAC�vI�dP SUSPENDED CEILING 1 BRACING DETAIL GRID�AT 10'�0" A.F.F. WITH WIND CLIPS ON TILES LEGEND: � 2x4x3/4 ARMSTRONG 769A PRELUDE XL 15/16" EXPOSED TEE SYSTEM OR EQUAL WITH ACOUSTICAL TILES �10'-0" A.F.F. UNLESS OTHERWISE NOTED � 2x4x3/4 ARMSTRONG 769A PRELUDE XL 15/16" EXPOSED TEE SYSTEM OR EQUAL WITH 5/8" (VINYL COATED) DRYWALL PADS 09'-0" A.F.F. UNLESS OTHERWISE NOTED 2'x4' (3 TUBE) T-8 ROURESCENT 0 LAY—IN FlMURE — FI.AT LENSE NL= NIGHT LIGHT LITHONIA: 2GT8 3 32 Al2 1/3 GE81015 0 I�� 2'x2' (2 TUBE) T-8 FLOURESCENT LAY—IN FlXTURE — FLAT LENSE NL= NIGHT LIGHT LITHONIA: 2GT8 2 32 Al2 120 250watt METAL HALIDE — HUBBEL TRIBAY WA 22 SERIES WITH ACRYLIC REFLECTOR OR ACCEPiED EQUAL REFLECTED CEILING PLAN SCALE: 1/8"= 1'-0" _ \% _ �J N � � � � s O VERSATILE � CONSTRUCTION GROUP, LLC. sm eon na�r eooa seae sio a 9610� P�31]9d535/9 Fox: }p,45.]581 _ �/ m 4'-0"long (2 TUBE) CHAIN HUNG FlXTURE FlMURE: C 23L M T-8 2 LAMPS: C 296 TBMU (48" TUBE) (MOUNTED ON CHAIN 12'-0"AF.F.) � � u RESTROOM ExHAUST FAN (FURNISHED & INSTALLED BY E.C. VENTED BY M.C.) 75 CFM GREENHECK, 120/60/10 PRICE SCD 24x24 NECK SIZE AS NOTED 24x24 PRICE 80—CORE PRICE RCDE � a � �� � �i � :� � � \/ � � � � � � L7 U � � Job No.: Date Stamped: 13039 02/18/14 Drawn By: Checked By: Scale: caw ta6 1/a^=t'—o^ CAD FlLE: G:\13039\a400 ceiling plan.dwg '�-( A. B'�,I' ���ii v �cixerr� �� : N o. 19700309 * STniE OF � CERTIFIED BY: THIS DRAWING IS THE PROPERTY OF VERSATILE CONSTRUCTION GROUP LLC AND IS NOT TO BE USED FOR ANY OTHER PURPOSE THAN THE PROJECT DESCRIBED HEREIN. snEEr m�. A400