Loading...
HomeMy WebLinkAbout21 E100 Electrical Plan.pdf3/Ocu TO MNN GAS PIPE a/o�� To uar WATER PIPE �6cu TO 8'-0' GROUND ROD 2 POLL CONTACTOR — POLE LIGFRS 3 POLL CONTACTOR EXTERIOR BLDG LIGHTS 7 DAY 71MER WRH PHOTO EYE OVERRIDE MODULAR &4SE 200A IOUSE 'ANEL 30 3 Ocu TO BUILDING EL 3/Ocu TO BUILDING FOUNDATION m�vrv �RVUrvDING DIAGRAM 1,600amp POWER C0. JUNCTION BOX •. � •. 200amp HOUSE PANEL- INSTALL FIRE ALARM PANEL AND DIALER TO MONROR SPRINKLER RISER FLOW SWITCH IRRIGATION CONTROL— PANEL (110v. TO HOUSE PANEL) ELECIRICAL SERVICE LOCATION TELEPHONE DEMARCATION- LOCATION � -- � � �� � -' �� �(4) 4" PVC SCH 80 CONDUITS ABOVE GRADE. (36" SWEEPS) TO TRANSFORMER (WIRED BY POWER COMPANY) 36�3/O�HOTS�C CONDUR 1-3/0 NEUTRAL TO UNIT PANELS MAIN GROUNDING DIAGRAM � i � �i i . gn i / , i ---'"� + ''/ i. ; � � � � i � i i i � i � i � i � / ` R RTII 1 ��, R �`. � � , � �� � � � � „ � ,� � ,� � ,� � , � 'wp � � gfi i i � i � r � i � i � i ` � . � � � � � � ' i i � � i i i i / � r � � i � i i i � ; , � � I I 1 1 I 1 I l 1 I I \ / / \ / / A / � �i � RTU 2 �; 1 ,� � � � � � � � � 'wP gfi � \ �` � � �� / � i � � i ` i �� i i � i ii �i i i ������ �� � o �°��' �, q ��� g� �� �� \ O j 'zooa 2ooa / <" ;, ,�, � gfi _— —_ i _-- r"� ;; �•� ���ti� r"� ;, i � `� / i � i � � � � � � r � r i i i i i i i i i i i i i i i i � i � i � � � � � � � � i � � � � � � � � �� \ � � �'.� RTU 3 ��, � � , �` �� , � ,, , � ,, � � ,, , , � , I � ' � � 'wp � i � � gfi ' i ' � i i � i i � i i ` i � � i � � r � � i � i � ! � GENERAL ELECTRICAL NOTES: 1. ALL CONDUCTORS SHALL BE $12 AWG COPPER THWN MINIMUM AND INSTALLED IN 3/4" EMT CONDUR UNLESS OTHERWISE NOTED. (ALUMINUM WIRE IS UNACCEPTABLE.) ANY CONDUCTORS LARGER THAN #10 AWG SHALL BE STR4NDED COPPER. 2. iHE CONTRACTOR SHALL COORDINATE INSTALLATION WITH ALL OTHER TRADES AND IN ACCORDANCE WITH THE N.E.C./AND ALL LOCAL CODES AND ORDINANCES. 3. THE CONTRACTOR SHALL PROVIDE A GROUNDING CONDUCTOR TO ALL EQUIPMENT IN ACCORDANCE WITH ARTICLE 250 OF THE N.E.C. 4. INSTALLATION SHALL CONFORM TO THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS AND IN ACCORDANCE WITH DICTATES OF N.E.M.A. ALL EQUIPMENT SHALL BE U.L. LISTED AND HAVE PRIOR APPROVAL BEFORE INSTALLATION. 5. ALL CONDUIT SHALL BE SUPPORTED TO THE BUILDING STRUCTURE WITH PROPER HARDWARE A MINIMUM OF 10'-0" CENTER TO CENTER, IN ACCORDANCE WITH THE N.E.C. 6. THE E.C. SHALL BE RESPONSIBLE FOR ALL CONTROL WIRING AND PROVIDING A COMPLEfE OPERATIONAL ELECTRIC�AL SYSTEM BEFORE FlNAL ACCEPTANCE BY THE ARCH./ENGR. 7. PHONE EQUIPMENT BOARDS TO BE FURNISHED AND INSTALLED BY E.C. 8. METER BASES SHALL BE FURNISHED BY THE ELECTRICAL COMRACTOR. (IF NOT FURNISHED BY LOCAL POWER COMPANY) 9. NEMA 3 TAP BOXES AND Sx 8 DUCTWAY SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTR4CTOR. 10. 4" CONDUIT FROM TRANSFORMER TO MEfERING POINTS SHALL FURNISHED BY THE ELECTRICAL CONTRACTOR AND WIRE FURNISHED AND INSTALLED BY LOCAL POWER C0. R IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILIN TO CONFIRM WRH POWER C0. 11. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND A PULL WIRE INTO EACH POTENTIAL DEMISED SPACE FOR iELEPHONE. i i 1 1 \ i i 1 1 \ � i f �� �i i � i i �� � I � � � �� LEGEND: ❑� R wp gfi ♦ �h ��h � ❑� � � � Q �i a �� � �� � � �I O --- � � ��� l+�--. � gn gn i �� r � i i --� �-" r' • • �y � � � � � � r � r � � � � i � i , � RTU 4 ��, 1 = ,� �� � , � , � � , , � ; � , � ,wp , 1 9r� ; i i �i i i � i � i � r � i � i � i � i � � � ��� I / � I , `� i i � II 11\ t` � ,, , ,; ,� i i i i i i i � � �\ � ��, I I I / i � 110 VOLT WALL MOUNiED GENERAL PURPOSE OUTLEf MOUNTED 018" A.F.F. UNLESS OTHERWISE NOTED 110 VOLT CEILING MOUNTED GENERAL PURPOSE OUTLEf UNLESS OTHERWISE NOTED 110 VOLT SLAB MOUNTED GENERAL PURPOSE OUTLET UNLESS OTHERWISE NOTED WEATHER PROOF 110 VOLT OUTLEf MOUNTED TO DISCONNECT ON ROOF TOP UNIT ON GROUND FAULT CIRCUfT INTERRUPTER DATA LINE MOUNTED IN SLAB UNLESS OTHERWISE NOTED A0. SMITH 6 GALLON DURA-POWER ELECTRIC WATER HEATER OR EQUAL. 110V h0. SMITH 10 GALLON DURA-POWER ELECTRIC WATER HEATER OR EQUAL. 110V 42 CIR. 30 208/120 ELECTRIC PANEL UNLESS OTHERWISE NOTED NEMA j�4 DISCONNECT EQUIPPED ON ROOF TOP UNR JUNCnON BOX WITH 2 CIRCUITS RAN BACK TO UNIT PANELS. JUNCTION BOl(ES INSTALLED AT 6" BELOW MEfAL ROOF DECKING 24"x24"x 3/4" TREATED PLYWOOD PHONE BOARD MOUNTED ON THE WALL NEXT TO ELECTRICAL PANEL E.C. TO RUN 1" CONDUIT TO TELEPHONE DEMARK LOCATION EXIT/EMERGENCY LIGHT WITH &4TTERY BACKUP LITHONIA EMERGENCY LIGHT MFG: LITHONIA EXTERIOR EMERGENCY LIGHT MFG: LRHONIA � � I � �� ,; �� � . � O r'� , � i i � i � R'TU 5 ��, 1 = ,� �� I ; , � , � � , , ,wp , gfi � i i i � � �\ r i ; I 1\ � I �' i i i i r � i i , i i i � i � � ��� I / .\ � O ; �~ � �y �y R '---�TT ` � RTU 6 ��, 1 ,� � ' I � ' , � , 'wP gfi � � � I � � � �--- , �; � '� �'o ! � RTU 7 1 � � , �� �� � , � � , � , � � � � 'wP gfi i i i ii � � � , r-'�. r,,--'c I 1 R ,_�� ELECTRICAL PLAN SCALE: 1�8'= 1'-0' O _� � -� 6 N � � � � s O VERSATILE � CONSTRUCTION GROUP, LLC. 5]0 Eost imcy Roa4 S1ile fi10 a 1610� P�31]9d535/9 Fox: }p,45.]581 _� ROOF TOP UNR INFORMATION: ALL UNITS SUPPLIED AND INSTALLED BY MECHANICAL CONTRACTOR AND WIRED BY ELECTRICAL COMRACTOR RTU 'I CARRIER 48TCEA05A2G5-OAOAO (4 TON) RTU S CARRIER 48TCEA05A2G5-OAOAO (4 TON) WITH ECONOMIZER WfTH ECONOMIZER 208/230/30 208/230/30 No. 10 FEEDER No. 10 FEEDER No. 10 GROUND No. 10 GROUND 30 AM DISCONNECT 30 AM DISCONNECT (Z� 2 CARRIER 48TCEAO6A2G5-OAOAO (5 TON) RTU G CAF2RIER 48TCEAOSA2G5-OAOAO (4 TON) WITH ECONOMIZER WITH ECONOMIZER 208/230 3S 208/230/30 No. 8# EEDER No. 10 FEEDER No. 10 GROUND No. 10 GROUND 60 AM DISCONNECT 30 AM DISCONNECT RTU 3 CARRIER 48TCEA05A2G5-OAOAO (4 TON) RTU % CARRIER 48TCEA07A2G5-OAOAO (6 TON) WfTH ECONOMIZER WfTH ECONOMIZER 208/230/30 208/230/30 No. 10� FEEDER No. 8� fEEDER No. 10 GROUND No. 8 GROUND 30 AM DISCONNECT 60 A P DISCONNECT RTU 4 CARRIER 48TCEA05A2G5-OAOAO (4 TON) UH� MARKEL 5100 - UH050240 WITH ECONOMIZER KW: 3.7, BTU: 12.8 208/230/30 208/39 10.4amps No. 10 FEEDER No. 8 FEEDER No. 10 GROUND No. 8 GROUND 30 AM DISCONNECT 15 A P BREAKER �� �� a �� � a � '� C) L7 U W Job No.: Date Stamped: 13039 02/18/14 Drawn By: Checked By: Scale: caw ta6 1/8"=1'-0" CAD FlLE: G:\13039\e100 elechical plan.dwg \`h��N?!ArEe���/i = No. _ * 19700309 * %�J STniE OF i� � CERTIFIED BY: THIS DRAWING IS THE PROPERTY OF VERSATILE CONSTRUCTION GROUP LLC AND IS NOT TO BE USED FOR ANY OTHER PURPOSE THAN THE PROJECT DESCRIBED HEREIN. snEEr n.��. E100