addendum 5.pdf
�A' , r � � . �1 � �� . �� 1 1 . . J GATEWAY SHOPS UPPER WINDOW FRAMING CLARIFICATION SCALE: 1 /2"= 1 '-0" ' ^ "�� ^ "�� 3/8" AFFIXED TO STRUCTURE JD (TYP. BRICK LEDGE) ATTACH STUDS TO STRUCTURE WALL WITH 12ga. METAL CLIPS (TYPICAL) STRUCTURE WALL W FACE OF BRICK CAULK (TYPICAL AROUND WINDOW TRIM) � SECTION °A" SCALE: 2"= 1'-0" (2) 3 5/8" (20ga.) METAL STUDS AT 6" (OUTSIDE FACE TO OUTSIDE FACE) SEE DETAIL BELOW (TYPICAL ALL FOUR SIDES) (2) 3 5/8" (20ga.) METAL STUDS ATTACHED TO STRUCTURE WALL SPANDREL GLASS (BLACK) CAULK (TYPICAL AROUND WINDOW FRAME) 5/8" OSB (TYPICAL) 1 1 /2" E.I.F.S. TRIM (TYPICAL) VERSATILE CONSTRUCTION � GROUP, LLC. 570 East Tracy Road, Suite 610 New Whiteland, Indiana 46184 Ph: 317.535.3579 Fax: 317.535.3581 SHEET No.1 of 1 REVISION DATE: 04/04/14