Loading...
HomeMy WebLinkAbout14050096 Energy Certificate � HOiVIE CERTIFIED TO MEET THE PROVISIOIVS OF THE 2009 INTERfVATIONi4L ENERGY COIVSERVATIOIV CODE This home built at 12687 MOOIVSEED DR., CARNiEL (AS DESIGIVED), IN by DEL WEBB • exceeds the minimum requirements for the 2009 International Energy Conservation Code 05-05-2014 Building Features Ceiling Flat: R-38 Duct Leakage lo Outside: 279.00 CFM @ 25 Pascals Sealed Attic: NA Total Duct Leakage: 372.00 CFM @ 25 Pascals Vaul[ed Ceiling: NA Infiltration: Hig:6.00 CIg:6.00ACH50 Above Grade Walls: R-16, R-15 Window:� U-Value:0.310,SHGC:0.280 Foundation Walls: R-14.1, R-11.0 Heating Fuel-fired airdistribution,Natural gas,93.0% EFF. Exposed Floor: R-30 Cooling Air conditioner,Electric,13A SEER. Slab: R-0.0 Edge,R-0.0 Under Water Heating Conventional,Eleciric,0.90 EF,50.0 Gal. Duci: NA The organization below certifies that the proposed building design described herein is consistent with the building plans,specifications,and other calculations submitted with the permit applicatlon.The proposed building has been designed to meet ihe.2009 IECC requirements in compliance with Chapter 4 based on Climate Zone SA and with all mandatory requirements.. Name: DEVIN SIELSCHOTT Signature: Organization: THERMO SCAN INSPECTIONS Date: May O5,2014 The 20091nternational Energy Conservatlon Code fs a registered[rademark o/the Internatianal Code Council,Inc.("ICC"). No versian a!this sallware has been revlewed or appraved by ICC orlts aflilfates. REM/Rate-Residential Ener Anal sis and Ratin Software v74.3