HomeMy WebLinkAbout14070067 Energy Certificate HOIVI� CERTIFIED TO IVIEET TFiE PROVISIONS OF THE
2009 4NTERNATION,4L ENERGY COIVSERVATIOIV CODE
This home built at
12675 IVIOONSEED DR., CARNIEL (AS DESIGNED), IfV
by PULTE HOMES
exceeds the minimum requirements for the 2009 International Energy Conservation Code
06-30-2014
Building Features
Ceiling Flat: R-38 Duct Leakage to Outside: 250.00 CFM @ 25 Pascals
SealedAttic: NA Total Duct Leakage; 431.00 CFM�@ 25 Pascals
Vaulted Ceiling: NA Infiltration: Htg:6.00 CIg:6.00 ACH50 .
Above Grade Walls: fl-16,R-15 Window: U-Value:0.310,SHGC:0.280
Founda[ion Walls: R-14.1, R-11.0 Heating Fuel-fired aii distribution,Natural gas,93.0%�EFF.
Exposed Floor: R-31 Cooling Air conditioner,Electric, 73.0 SEER.
Slab: R-OA Edge, R-0.0 Under Water Heating Conventional,Electric,0.90 EF,SOA Gal.
Duct: NA
The organization below certifiesthat the.proposed building�design described hereireis consistent wfth thebuilding plans,specifications,and other
calculations submitted with the permit application.The proposedbuilding has been designed�to'meet'the2009 IECC requirements in compliance with
Chapter 4 based on Climate Zone SA and with all mandatory requirements. �
Name: DEVIN SIELSCHOTT Signature:
Organization: THERMOSCANINSPECTIONS Date: June30,2074
The 20091�temational Energy Gonservation Code is a registered trademark af the lutemational Code Council,Inc.('7CC').
No version�ol�this soitware has 6een reviewed�or approved:by ICC�o�.(tsa/f7liafes.
-REM/Rate.-Resitlential EneF�� Anal sis and Ratin � Software v14.3