Loading...
HomeMy WebLinkAbout14070052 Energy Certificate � —'- � � HONiE CERI'IFIED TO iVIEET THE PROVISIOiVS OF THE 2009 INTERN�►TIOIVAL ENERGY C06VSERVi4TION CODE This home built at 13232 FROGMORE ST., CARMEL (�4S DESIGNED), IN by WEDGEWOOD BUILDING COMPANY exceeds the minimum requirements for the 2009 International Energy Conservation Code 07-03-2014 Building Features Ceiling Flat: R-38.0 Duct Leakage to OuGSide: 492.00 CFM @ 25 Pascals SealedAttic: NA Total Duct Leakage: 656.00 CFM @25Pascals Vaulted Ceiling: R38.5 Infiltration: Htg:6.00 Clg:6.00ACH50 Above Grade Walls: R-16.0 Wndow: U-Value:0:300,SHGC:Q290 Foundation Walls: R-15.0 Heating Fuel-fired air distribution,Natural gas,92.1 AFUE. Exposed Floor: R-30.0 Cooling Air conditioner,Electric,13.0 SEER. Slab: R-0.0 Edge,R-0.0 Under Water Heating Convenfional,Natuwl gas,0.63 EF,50A Gal. Duct NA The organization below certifies that the proposed building design described herein is consistent with the building plans,specifications,and other calculations submitted with the permiTapplication.The proposed building�has been designedto meet the 2009 IECC requirements in compliance with Chapter 4 based on Climate Zone 5A and with all mandatory requirements. Name: DEVIN SIELSCHOTT Signature: Organization: THERMO SCAN INSPECTIONS Date: July 03,2014 The Y0091ntemational Energy Conservation.Code is a regisfered trademark of fhe Intemational Cade Council,Ina("ICC"): No version o(this so(tware�has been reviewed oi approved tiylCC orits a/(iliatea � REM/Rate-Residential Ene� Anal sis anii Ratin SoRware v14.5