Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
14070052 Sewer/Water Permit/s (2)
�- � s .t ,., � E� i D. � ' 10701;N.';College;Avenue Suite A Indianapolis,Indiana 46280; phone 31;7,=84g=9200 fax 31,7=844=9203 .www:cttwd:org Ftesidential $ANITA�tY SEWER PERNflIT' 06787,' --- Permit'-T e _ __ ___ C Subdiyision Village of Westclay,. YP _; _.._. .. .:._ Fina, . ----------- ----=-- Project'-WO, ENG9262006I SecYion,Numbec 900i - ---- —___ ---- --- c'= ------- - _ ---__. =_.. _,__ P.rojecfName VN/C�900_1_ Lot,Numbe'r _ 1§6_ _-_- --_-- ---- --- '------- ----------- _ _ . Project;Developer Brenwiqk Address Number 13232 --—----- - --.- -�--' . . -_-_------___:_ ------=_=-' Lift Station; __ _ _ _ _19 Viliage"of�Westclay Station Address 2 - ------ ------- - '=-- -- - - -° Treatment Plant _,._ ___ MIX Street _.;Frogmore StreeF -. -_- -. _ _----- - - --_ '= ` - _--------.. ParoellAoreage ,- _ Cit _ _.-. .. . --- ------- _----- _. =_= -- ._.= ------ ---__--� ------------- - Y _ arme EDU in Gallons 310_ Zip,Code , ,_ 46032 _ ---- __- .--------- ----- : County Hamilton' � ._. _, , _ __- -- -- -- - LocauSewer,Charge�DistrictContribution Buil_der Wedgewood Builcling Company , � -. ---------_-__. Plan Revigw and lnspection; - - ----- °== -- Application'Fee . $150.0o Phone'Number, , , _, 317 669=8530� ------- _- __ __-- ---_ -_. ---=-= - `-== -__�_ _ _ EDU'Fee $,i 650?00 Owner, - _ -- __ ____ __ _ , InterceptorFee _ _,___ ---------------------°-- _. o._ -_=: ---__. Phone;Numher . _... ._ OtherEees; --_-_: ---,-. -------------`--`-- ------'= -----'- ------ _-,. Occu ant, - -'--- - -- -- Fee§.Due ---_-------------- ,800.00;_ p $1 --- ---- .. Inyoice'Numtiei ._e,._ Phone,Number PLEASE NOTE'.'Iristallation of buildmg sewer shalh;be-per the specihcations of the Clay'Township Regional Waste: Disfriot ('see reve�se)�and any,conddions�noted below. All installations shall be inspectedby Distnct?personnei during o en„trench' Fiase and before(backf'illing,with stone to twelde inches,abovetHe:pipe. NO•footing or foundation P � P drams,..or otherlsources ofygroundvor�stormwater„sfiall be permitteii�to,ente"r'tfie District'ssarntary,sewensystem.`Tlie District will assume no liabilityfor drains which'are;6elow the}grad`e.level�of.the;nearest downstream manhole,no�-foi . , .:. lateralswhich are�extended tieneath;driveways or sidewalks. The permif holder(properry'owner, developer orbuilder) wiil be responsible'for damages to the DistncYs sewe�'system. This inciudes damages to;manhole§, castin'g§; _„ � ._ ._., manhole lids and tfie hke;;caused 6y'c'onstruotion activity on tfie_building site wtiich is,the subjeciof this;permit!. - Inspections by tfie pist�ict are MANDATORY and shalPbe a�rariged 6y qontactingf;heiDistrict`s�,officeiat?844'=9200. 24 hours in advance. All;new oonstruction°will tie.placedon:tiilling twamonths after'connection hasibeen,made o%� when water is�connected,,whichever comes�first: - - - - The tiuilding'has: Main VWC,442N=VWC441Ni � Grease T�ap No Slab Foundation No --- __- _ Grease lnterceptor No Crawl Space No Manhole IDS USMH WyC-442N VWC;4¢iN' DSMH °- --- `-=°- _ ,, Grit'Interceptor No ,Baseroent',___ Yes Lid'Elevation 903 69 it'✓ 902:83 ft� _ __ __ ' ___ ,_,_, -_--.-, ._-_--_ _ =..,. � First Flooi,Elevation 905.30 ft✓ 905 30 ft ✓ Grinder Station N_ - ---- -� Water:Service: Citybf�Carmel gasement Elevation 69580 ft✓ 895.30 ft � -- ----- --_- —` -----==- ----`- __-= -°--: . - � . Calculation is based,on both�Manhole L�d`Elevations and.the elevation'ol,the Firs6Floor 1 61 . 2.37 . _ _ " Per Ordinance 9 13-99 and theslevations'provided;the�substructure shall tie plumbed by: Ejector Pump �e The Districticurrentlyreguires that:an I&I.inspection is performed and a Certificate of.Compliance is issuetl prior to; occupanc'v/sale of a properrtv..Please reviewiattached IA'Pe�mk �- ManholePs sfiali rerriain;accessible'be,installed'Buried manM1oles wilPtie c�o�reoteii'by the'DevelopedOwner �- ,The ro er'class of"cleanout mustat all times• eve ,100 feet of_laterel i e measured from sewe7 m'" o,structure. The:terms;ofthe;conditionalpe�mit,'ifany,;areli§ted',below. , pE?N�� A�yq,y tiP�� /�TO 2 _ Q p � . < J-+ � � f � " - - . - ` --_ - - - = - - 'qF � _ < - - � . .� � , . , , _ All conditionsihave tieen met:Connection;to the sanitary sewer.is now rmitted. � By,signing'�below,I!attest that I amsfamiliarwitti�,lheiDistiicYs specifications�and agree��.to'accep[responsibility;_for;all work done under�this�permit.. Builde�7/"OwnerSignature �', � PhoneNumbe�. �1�_��__ �;i5 ` 1 P�inted:Name � � :�` ,,s�r � Approved By � e `� � ' � ,�� ���" � - ��.,,�� , Rya man, � ��o�smctengnreeu� .f�e�Rllt � 8te' ,7. �O14 _ .. . Permit is valid r ON YEARifrom;tfie'date,issueH. Permifvalid:onlq witFiiCTRWD seal in red ink1. �--- - -- , SUMINARY°OF LATERAL INSTALLATION REQUIREMENTS 1 All fiouses ,buildings.etc.; shall connect to the;pistncYs;sanitary sewer system wtthin'90 days of.notice proviiiing a sewer is witliin:300 feet for Hamiiton'County or°100 feet for'Boone County of`tfie�property'Jine,as defiried�through .�... Indiana Code',pC 1326=5-2) Only one building may�connect to'the:sewe�iriain pei Iate�al:unles§�otRervvise approved;by tfie;District. �2 No,.foundation;:Sump Downspouts or other storm water'drains shall be'inte[connected;to?District!s,sanitary;sewee as;addresseditFirough o`u�',I/I O�dinance 12.08;08Eand I%I Policy found on ou�webstte�at;www.ctruvclb�g. ;3. The ezisUng;sewer.line from the building`ro�the septic'tank may only;be'used if.'iNis looated undera'tiuilding addition patio;,porch or paved driveway Air tesYis�required to�show:.;rf;acoepta6le;for-r'e-use. The property owner stiall bear the;cost of alPtesting� The District'inspecto�,must be onsite,for the du�ation:of�the.airtest: 4'. The district sfiall inspect ALL laterals: The owner or contractor sliall notify the District'p�ior.tatiackfilling;tfie in5talled - ,.:_. _ _ .. _ lateral so the Distncfcan make an inspection to determine.compliance with;tfie:DistricYsseweYuse�o�dinance: Lateral stubs sRall remain��capped•unt�l an',inspector�is�on sde.,Final connection'ishall onl'y be.made=under direcC _ y.. ., ,,. . superwsionbof;a,CTRWD inspecto�: If an'inspection fails�+and a second inspection is required or the;cont�acto�is`not- on sitg;for the sclieduled;ins"pectiorr, a fee,ofi$100;00 will be assessed antl mustbe,paid prior to the:time�of�;thie, follow up.inspection. , 5 Property owners are hereby,adyised,that the Gounty Board of Health regulates the operation'and maintenance of, priyate sewage sdisposal (septic) systems. TfieiCounty�Oriiinanceprovides;in part that, upon,c,onnection to a public sewer a septic'tank ...sfiall be a6ancloneds(pumped clean)�and filled compietely with�earthen material o�:§tone,in.a safe�and sanitary�mannec" Please:contacCthe�appropriate County Board of Health for fuither information and6to noti.ty'the department?of the abandonment. � �� - 6. Acoeptatile Pipe'Materials:; PVC PIPE: SDR 35.oY%SDR 26;�ASTM D3034; SIX,INCN RIPE PVC PRESSURE RATED.RIPEi SDR 21, ASTM,D2241,�SIX`INGH`PIFE � RESTRAINED JOWT PVE P.IPE(QIRECTIONAL DRILL)'. Yelomine,SDR'r2t, ASTM D2241„iSiX INGH:PIPE(use only pe_r,approyal of the�DistricY,Engineer) GASKET;ED,JOI NTS`.,ASTM:;D32-12 GASKETS:,ASTM;F477 FITTINGS:SDR26�OR BETTER,("FERNCO""QRaSIMILAR FLEXfBLEiCOUPLINGS'TYPICALLY'NOT ALLO_N/,ED) DUCTILE IRON'MECHANICAL,COUPL`INGtWITH PBQPER FITTINGS PRIVATE GRINDER,FUMPS-ACGEPTABLE;,P,IPE MATERIAL: IF CONNEGTING INTO'A;L`OW-PRESSURE;FORCE!MAIN-� CTRN/D must,be contacted for explanation of aliowable;pumps,and,pumpyreguirements' 1 25" HDPE DF17 IPS;(TYPi),connect�ons:areito be made with (Polypropylene+onStainless Steel);;Compressfon Fittings or Electrofusion ALLPUMP CONNECTIONS . • ° clean ut�nstal�l d antl tfie 3i eeslialltlbe t ans t orned'to 6"�SDR 35;along the 6uilding for;more;than 3'+shall fiave;a. p p _ „ _ . ___ „pipe For connection'into the pump 'station: CL'EAN:OUTS ARE i0 BE�LOCATED,NO MORE THAN`THREEiFEE7`FROM'THE FOUNDATION AND FOR GRAVITY'L'ATERALS'NO MORE THAN 100�FEET AP.AFiT'(please see:Clean�0ut Details Type 2 and Type 3 for multiple oleanout installation requirements). CL'EAN OUT:CAP REQUIREMENTS`.; 61-PVC TFi�ead'ed Caps __ ., '7 BEDDING•- Use Numbe�Fg crusfied'§tone,or Number 8_hactured'face aggregate Number8 stone backfill.material � is to;be placed from 6 inohes below-to 12'inches above��the pipe�The��trenoh�sfiould be�a;ioinimunisdff�l8 inofieswide> (siz'inclies'onbothsidesaof;tfie:pipe) ;;::;;, .t, ,: , 8. LateralscsfiallAbe installed°no closer 4fiam20 feeYfrom water wells unle5s P,VC p�essure�,grade pipe;is used meeting SDR. 21 and,ASTM`D224] , Any.proposed installation requving�piessure pipe^shall'berreviewed and,accepted 6y the'District and the,DistricYs,engineer prio[�to'installation. : ,. 9 Where a[ransition is'made between SDR:35 pipe and,pressure;gradefSDR 21';pipe, a4ductile iron;gasketed . _ ,., . _. mechanical,coupling shall be used:, � 10 Laterals shall te�minate,within 3:,feet of the:building unless the�conditions m'.ifem #3 above'are`met. No;;glued,pipe � -,r.. .., . _ . .._ . _ shalLbe;installed;outside+th�ee�feet of building'foundation walls: , 11 Additional info�matiornon` Distriotistandards and speafications may;tierobtaineclifrom;tfie;Dist�icPs;office:during, . . .._ . business�hours of 8 OOa`m. to 4:30p:m Monday througlil'Friday: All District;stanilard§,can,tie looated on our web - sitg;at;http://www.ctiwd;oig. ` - - - - � - ClayTownship Regional`Waste Disfrict 10701 College Avenue- Suite A Indianapolis;Jndiana,46280 _� 10701 NorthiGollege Avenue Suite;A lndianapolis, Indiana 46280. Phone'(317)-844-9200' Fau.(317)-844-9203; 12! Septic,effluentshall not;6e pumped;out into;tfieisanitary sewer.-system. 13. Cont�actors sfiaU.lay 14;gauge=solid wire the entire lengtfi of the;late�al. 'Wire is"fo,tie:placed on top of tlie'lateral. She',District ins ectorwill veri � ' - � p _ ___fy placement of the�wire. After inspection, beiiding is.to:tie plaoed!on;top: 14. Aif extenors st�uctures and;;pipingare;sutijecYto,be,testeii,and/or:televised'upon the Districts discretion. Examples of structures that may be'included,are;manFioles gr�t inte�oeptors,pump pits;.grease interceptors etc Testing ,,. r a. requirements are'to verifythat,all st[uctures a�e:wateitight`and that tfiey conform to the'Districts I/I'Policy: - -w 15: Call tiefore you;dig. IUPPS 1-800=382-5544,.48;hours�,priorto digging: � Bevised 02/21%2014.tiy,TK�