Loading...
HomeMy WebLinkAbout805 IRRIGATION DETAILS.pdfLandscape Designers & Consultants (800) 680 6630 2500 CityWest Blvd, Ste 300 Houston, TX 77042 www.landscape-consultants.net RI V E R R O A D S H O P S &G X G N Q R O G P V  % Q P U W N V C P V U 6T C P U R Q T V C V K Q P  PR E L I M I N A R Y NO T F O R CO N S T R U C T I O N 1-800-382-5544 or 811 IR R I G A T I O N D E T A I L S G SCALE: NTS BRASS BALL VALVE MA I N L I N E D E P T H 3-INCH MINIMUM DEPTH OF 34-INCH WASHED GRAVEL FINISH GRADE AT 1" BELOW TOP OF BOX IN TURF AREAS: 2" BELOW TOP OF BOX IN SHRUB/GROUNDCOVER AREAS 7 IRRIGATION MAINLINE 1 4567 2 3 1 9" ROUND VALVE BOX WITH LOCKABLE LID EXTENSION SECTION AS NECESSARY TO MEET GRADE BRASS BALL VALVE (SIZED PER MAINLINE) PVC MALE ADAPTER 3 4 2 5 6 PVC CAP, SOLVENT WELDED12 789 24 " M A X 18 " M I N . 24 " M A X 2 24 " M I N . 18" MIN. 1 H SCALE: NTS PIPE AND SLEEVE INSTALLATION 18 " M I N . 12 " M I N . 24 " M I N . 12 " M I N . CONTROL WIRES - TAPE TO MAINLINE AT 10' INTERVALS11 SCH. 40 PVC WIRE SLEEVE FOR CONTROL WIRES, MIN. 2" DIA. SAND BACKFILL PVC IRRIGATION LATERAL - BURIED MIN. 12" BELOW GRADE FINISH GRADE 789 6 4 31 10 11 5 32 TRENCHING SLEEVING PVC IRRIGATION MAINLINE LOCATOR WIRE W/BURIED CAUTION TAPE SCH. 40 PVC LATERAL SLEEVE - SEE PLANS FOR SIZE SCH. 40 PVC MAINLINE SLEEVE - SEE PLANS FOR SIZE TRENCH BACKFILL PAVEMENT SURFACE1 3 4 7 9 2 6 5 10 8 I SCALE: NOT TO SCALE SUBSURFACE DRIP LINE LAYOUT 2 5 3 4 7 8 6 5 1 5 4 2 3 8 7 6 5 4 3 2 1 FLUSH VALVE SCH. 40 PVC EXHAUST HEADER SCH. 40 PVC TEE OR ELL COMPRESSION ADAPTER DRIP LINE AIR RELIEF VALVE AT HIGH POINT OF SYSTEM (WHERE INDICATED ON PLANS) SCH. 40 PVC SUPPLY HEADER CONTROL VALVE NOTE: SET DRIP LINES 3"-6" AWAY FROM HARDSCAPE 2" M A X . LA T E R A L L I N E D E P T H J SCALE: NOT TO SCALE SUBSURFACE DRIPLINE CONNECTION 4 7 6 5 4 3 2 1 6 7 5 3 21 SCH. 40 PVC SUPPLY HEADER (SIZE PER PLAN) SCH. 40 PVC TEE (SST) SCH. 80 PVC NIPPLE (LINE SIZE) INSERT TEE OR ELBOW DRIP LINE PER PLAN FINISH GRADE TOP OF MULCH K SCALE: NTS FLUSH VALVE 3 7 6 5 4 21 7 6 5 4 3 2 1 6" DEEP LAYER OF PEA GRAVEL RED BRICK TYPICAL, 3 REQUIRED BALL VALVE, LINE SIZE DRIP EXHAUST HEADER FINISH GRADE - TOP OF VALVE BOX TO BE 2" ABOVE FINISH GRADE IN PLANTER AREAS 10" ROUND PLASTIC VALVE BOX WITH LOCKABLE LID, "CARSON" OR APPROVED EQUAL 3' COILED LENGTH OF LINE SIZE FLEX HOSE. SOLVENT WELD TO VALVE L SCALE: NTS POP-UP SPRAY HEAD 12 " M I N . 2 6 75 3 5 4 1 PVC LATERAL PIPE SCH. 40 PVC TEE OR ELL SCH. 40 PVC STREET ELL SCH. 40 PVC ELL SCH. 80 PVC NIPPLE (LENGTH AS REQUIRED) POP-UP SPRAY HEAD FINISH GRADE 2 3 4 1 6 7 5 F SCALE: NTS QUICK COUPLER 13 11 9 12 1098 6 7 5 4321 3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL6 TOP OF MULCH1 2" x 2" REDWOOD STAKE WITH STAINLESS STEEL GEAR CLAMPS OR EQUIVALENT SUPPORT SYSTEM PVC SCH 40 ELL PVC MAINLINE PIPE PVC SCH 40 TEE OR ELL PVC SCH 40 STREET ELL BRICK (1 OF 2) BRASS NIPPLE (LENGTH AS REQUIRED) 6" LONG BRASS NIPPLE 10" ROUND PLASTIC VALVE BOX BY CARSON (OR EQUAL) QUICK-COUPLING VALVE FINISHED GRADE-1" BELOW TOP OF BOX IN TURF AREAS, 2" IN SHRUB AREAS 11 10 9 13 12 8 5 7 4 3 2