Loading...
HomeMy WebLinkAboutTW AUDI - DRAINAGE 2 of 5.pdfSH E E T OF DATE: PROJECT #: DRAWN: CHECKED: THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED TO ADS UNDER THE DIRECTION OF THE SITE DESIGN ENGINEER OR OTHER PROJECT REPRESENTATIVE. THE SITE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATE RESPONSIBILITY OF THE SITE DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS. 4640 TRUEMAN BLVD HILLIARD, OH 43026 1-800-733-7473 REV DRW CHK DESCRIPTION TOM WOOD AUDI INDIANAPOLIS, INDIANA 3-17-14 SKR 45471 2 5 GFI 00 15'30' 44 . 8 5 ' 42 . 2 5 ' 860-529-8188 |888-892-2694 | WWW.STORMTECH.COM Detention Retention Water Quality 105.34' 94.13' INSPECTION P O R T BM P 1 0 1 (PER ENGINEER'S P L A N ) (RELOCA T E D ) (DESIGN BY ENGIN E E R / PROVIDED BY OTH E R S ) 6" A D S N - 1 2 D U A L W A L L P E R F O R A T E D H D P E U N D E R D R A I N (S I Z E T B D B Y E N G I N E E R ) 15 " X 1 5 " A D S N - 1 2 M A N I F O L D MA X I M U M I N L E T F L O W 1 4 C F S , I N V 9 " A B O V E C H A M B E R B A S E (S I Z E T B D B Y E N G I N E E R / S E E T E C H S H E E T # 7 F O R M A N I F O L D S I Z I N G G U I D A N C E ) PROPOSED ELEVATIONSMAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED):743.64MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC):737.64MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC):737.14MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT):737.14MINIMUM ALLOWABLE GRADE (TOP OF REINFORCED CONCRETE PAVEMENT):737.14TOP OF STONE:736.14TOP OF CHAMBER:735.6415" TOP FEEDING MANIFOLD INVERT:733.8918" OUTLET MANIFOLD INVERT:733.2724" ISOLATOR ROW INVERT:733.15BOTTOM OF CHAMBER:733.14UNDERDRAIN INVERT:732.64BOTTOM OF STONE:732.64 ISOLATOR R O W 24" PREFABRICATED END C A P PART# SC740EP E 2 4 B TYP OF ALL SC-74 0 2 4 " CONNECTIONS AND ISOLATOR R O W S PL A C E M I N I M U M 1 2 . 5 ' O F A D S G E O S Y N T H E T I C S 3 1 5 W T K W O V E N GE O T E X T I L E O V E R B E D D I N G S T O N E A N D U N D E R N E A T H C H A M B E R FE E T F O R S C O U R P R O T E C T I O N A T A L L C H A M B E R I N L E T R O W S PROPOSED LAYOUT(117) STORMTECH SC-740 CHAMBERS(18) STORMTECH SC-740 END CAPSINSTALLED WITH 6" COVER STONE, 6" BASE STONE, 40% STONE VOIDINSTALLED SYSTEM VOLUME: 9,676 CF (PERIMETER STONE INCLUDED)$5($2)6<67(0)7ðPERIMETER OF SYSTEM: 300 FTPROP O S E D O U T L E T C O N T R O L S T R U C T U R E (DESIGN B Y E N G I N E E R / P R O V I D E D B Y O T H E R S ) 18 " X 1 8 " A D S N - 1 2 M A N I F O L D MA X I M U M O U T L E T F L O W 8 C F S , (S I Z E T B D B Y E N G I N E E R / S E E T E C H S H E E T #7 F O R M A N I F O L D S I Z I N G G U I D A N C E )