Loading...
HomeMy WebLinkAboutTW Audi - E1_01-PERMIT.pdfI I LJ � I J LJ � 1 ��� 11�11 I I I I I I I 7 I_I_II_ __ I- L - � � � TYPE A1 � TYPICAL I , I I I I I I I I I I I I I I I I I I _---I _---- � --- �--- _---- TYPE D TYPICAL - . � _--- _--- _-�_- � � O ��\I \ � � � � � m SITE IJ\J ELECTRICAL PLAN � SCALE:1 "=30'-0" CODED NOTES O 1. EXISTING TRANSFORMER TO REMAIN. SEE ONE LINE DIAGRAM FOR NEW WORK. 2. 120V SIGN POWER. USE p8 KIRING. RUN THROUGH RELAY PANEL FOR 71ME BASED CqJTROL. 3. MAKE FlNAL CONNECTIONS TO CHARqNG STATION (208V-10, 7.2KV�. MOUNT ON PEDASTAL. 4. REFER TO SIIE PLAN FOR DEMOLI710N OF POLE LIGHTS. REVISE/MAINTAIN CIRCUITING TO EXIS7ING POLE BASES TO REMAIN. GENERAL NOTES -�-- 1. NEW POLE LIGHTS ARE MSTALLED ON EXISTING POLE BASES. AIAMTAM EXISTING CIRCUITING. CONNECT TO EXISTING 480V-16 CIRCUITS. 2. FlELD �ERIFY CIRCUITS SERVING POLE LIGHTS AND PRONDE CIRCUIT NUMBERS ON AS-BUILT DRANINGS. ....._._.......__ ___._... � - ._... .- ._ __ � _ _ O� ...� � ... . 1C-34,36 � � a i � � I � I - ■ - - - I I I � I I I � u 1C-�8 O I O I I I i-lC.-4U� I ' C H � I u I I I - � _ J I � I _ �_ I I I I Panel ID: SLi Voltage: 480 / 277 Panel Type: --- Location: --- Phase: 3 Enclosure: NEMA-1 Mounting: SURFACE Wire: 4 Main T e: M.L.O. Main Size: 100 Am s *+ = Refer to one line dia ram for wire sizes. CKT CKT CONN. CONN. CKT CKT GND W1RE BRANCH CIRCUIT BKR BKR LOAD CKT PHASE CKT LOAD BKR BKR BRANCH CIRWIT W1RE GND SIZE SIZE DESCRIP710N SIZE OP710N KVA NO. NO. KVA OPTIIXJ SIZE DESCRIPTION SIZE SIZE EX EX SITE LIGHTING 20/2 EX 1.841 1 A 2 1.227 EX 20/2 SIIE LIGH7ING EX EX E% - - - 1.841 3 B 4 1.227 - - - E% EX EX SITE LIGHTING 20/2 EX 1.841 5 C 6 1.227 EX 20/2 SIIE LIGH7ING EX EX EX - - - 1.841 7 A 8 1.227 - - - EX EX EX SITE LIGHTING 20/2 EX 1.841 9 B 10 0.000 EX 20/1 SPARE EX - - - 1.841 11 C 12 0.448 EX 20/1 WALL LIGH7S 12 12 EX EX SITE LIGHTING 20/2 EX 1.841 13 A 14 0.000 EX 20/1 SPARE EX - - - 1.841 15 B 16 0.000 EX 20/1 SPARE E% E% SITE LIGHTING 20/2 EX 1.227 17 C 18 0.818 EX 20/2 SIIE LIGH7ING E% EX EX - - - 1.227 19 A 20 0.818 - - - EX SPARE 20/1 EX 0.000 21 B 22 0.000 EX 20/1 SPARE SPACE 20/1 - 0.000 23 C 24 0.000 - 20/1 SPACE SPACE 20/1 - 0.000 25 A 28 0.000 - 20/1 SPACE SPACE 20/1 - 0.000 27 B 28 0.000 - 20/1 SPACE SPACE 20/1 - 0.000 29 C 30 0.000 - 20/1 SPACE Connected Load Panel Summary Breaker ODtions Qf UseA): Phase A: 10.0 KVA 36.2 AMPS HT - Handle Tie Phase B: 6.7 KVA 24.! AMPS LO - Lotk-On DeNte Phase C: 7.4 KVA 26.7 AMPS GF - GND Fault CKT Intertupter Total: 24.2 KVA EX - Ezlsting to Remaln SH - Shunt tti Breaker � �� C%) J O � � O Zo � � � O Z � � � � � � J �..�..� Q U � �..�..� WQ °� z � Q _ � � z � � � Q �..�..� � T � � seei sti ��zita "� PR � ��M\'s'r AT< � P�6 FqF` � � 10302274 �v'�_ STAT6 OF O5/22/14 Dawings O Preliminary � Bitl Se� � Pertni�5et SI22I2014 � Cons[mc[bn Revisions � � � � � � � � � .TE & � Projecl Numbar � � _ A13-079 � �� snaa�rna ° SITE E1-01-14001.DWG � r PRATER € � ELECTRICAL PLAN � �r Engineering Associates, Inc. ��� shee� N�m�, s Dubl�in�Ohio 43016 FAX: �6143 766 2354 �/ DEApIm BY DRANN BY p1ECIQ0 BY JOB NUM. / E 1 • O� C50 CSO OLP 11001