HomeMy WebLinkAboutWater Distribution Plan Sheet 34I W z J N w 1-1 1' -0 "(MIN.) C14 (CONFORM TO LOCAL REQUIREMENTS) VALVE i' REDUCER MAIN TEE OR ✓ALVE BOX INSTALLED IN ACCORDANCE WITH SPECIFICATIONS CONCRETE THRUST BLOCK EIRE HYDRANT DETAIL (NO SCALE) O.D. + 1' 15' -20' -III III- (ANGLE VALVE =I I I =I PROTECTED -III III- WITH PLASTIC WRAP =I I= w -III III: Z =1 1= -III III: W =I I 1 " CORP. I= 0 COCK III n' 1 " COPPER SERVICE -III III IPIPE � TO B E SUPPORTED ALONG ENTIRE LENGTH — EXCAVATE FOR EACH JOINT WATER SERVICE INSTALLATION (NO SCALE) NO WATERMAIN VALVES ARE TO BE PLACED WITHIN THE STREETS. NOTE: POSI -CAPS OR EQUIVALENT IS REQUIRED ON ALL WATER VALVE INSALLATION. I m wu CONCRETE THRUST BLOCKING CONCRETE TO BE POURED BETWEEN PIPE & FIRM FACE OF TRENCH AT ALL TEES BENDS & PLUGS TYPICAL THRUST BLOCKING (NO SCALE) SCALE: 1`60' °� • No. 19358 -o •' STATE OF L ALL WATERMAINS SHALL BE DUCTILE IRON AND INSTALLED PER THE CITY OF CARMEL SPECIFICATIONS "HOLEY MOLEY" SAYS: 1- 800 - 382 -5544 CALL TOLL FREE 1- 800 - 428 -5200 FOR CALLS OUTSIDE OF INDIANA CAUTION LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, & marks made upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. :. V) z 0 (N 5 w Y Cy- Q w H Q 0 N M LL MM 3 ^II oN N O N \ w li H w U V' Of 0 C) U-) z Q Z U rot, 0' -,d- 00 I LEGEND 0 —6' " 0 2' -0" DIA.X2' -0 "DEEP z Q MIN. 0) DRAINAGE PIT LINED V w �r w I Z AND COVERED WITH 00 z Ld GEOTEXTILE FABRIC o Z 6) V) Z) it- w 00 PROPOSED HYDRANT z ° =`= GRAVEL CONCRETE / • VAL VE CONC RETE OR AINCHORD THRUST CAST —IN —PLACE AGAINST BLOCKING IF UNDISTURBED GROUND REQUIRED ■ BLOW OFF ASSEMBLY i' REDUCER MAIN TEE OR ✓ALVE BOX INSTALLED IN ACCORDANCE WITH SPECIFICATIONS CONCRETE THRUST BLOCK EIRE HYDRANT DETAIL (NO SCALE) O.D. + 1' 15' -20' -III III- (ANGLE VALVE =I I I =I PROTECTED -III III- WITH PLASTIC WRAP =I I= w -III III: Z =1 1= -III III: W =I I 1 " CORP. I= 0 COCK III n' 1 " COPPER SERVICE -III III IPIPE � TO B E SUPPORTED ALONG ENTIRE LENGTH — EXCAVATE FOR EACH JOINT WATER SERVICE INSTALLATION (NO SCALE) NO WATERMAIN VALVES ARE TO BE PLACED WITHIN THE STREETS. NOTE: POSI -CAPS OR EQUIVALENT IS REQUIRED ON ALL WATER VALVE INSALLATION. I m wu CONCRETE THRUST BLOCKING CONCRETE TO BE POURED BETWEEN PIPE & FIRM FACE OF TRENCH AT ALL TEES BENDS & PLUGS TYPICAL THRUST BLOCKING (NO SCALE) SCALE: 1`60' °� • No. 19358 -o •' STATE OF L ALL WATERMAINS SHALL BE DUCTILE IRON AND INSTALLED PER THE CITY OF CARMEL SPECIFICATIONS "HOLEY MOLEY" SAYS: 1- 800 - 382 -5544 CALL TOLL FREE 1- 800 - 428 -5200 FOR CALLS OUTSIDE OF INDIANA CAUTION LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, & marks made upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. :. V) z 0 (N 5 w Y Cy- Q w H Q 0 N M LL MM 3 ^II oN N O N \ w li H w U V' Of 0 C) U-) z Q Z W > 0' -,d- 00 V 0 X z Q a 0) V w I tAJ r- w I Z O 00 z Ld o Z 6) V) Z) w 00 o 0- z z z z Q 0 z Z Q -J Z a- _O Z O U Uj W %le W W 1E-- W V J - U W W W p Q J L LJ Q U SHEET NO. 34 OF 37 SHEETS JOB X0.42611